For a better understanding of this product, please read this user
manual thoroughly before using it.
Wireless GSM
2013.3.V1.0 Alarm System
Function Settings Functions Settings
5 6
Operating Instructions Operating Instructions
Home Arm: in arm status, the defense zone which is set as [Home LCD display:
Arm] will alarm when detectors are triggered.
Disarm: defense zone 1~99 will not alarm when detector triggered
(except 24 hours defense zone)
System setup status: In this status, all defense zones will not alarm
when detectors are triggered. 4.Home Arm
It means, for the safety, while somebody is at home, you need to
2.Remote Controller Operation enable the peripheral door, window, balcony and boundary detectors of
Users can use remote controller to set system as Out Arm, Home Arm, the alarm system while prevent from triggering the indoor detectors,
Emergency Alarm, Real-time Disarm and etc. which may cause improper warning; then, you shall select Arm at
Out Arm: Press button Home, let just part of the detectors work and disable the other parts.
Disarm: Press button Main unit Operation: Press [HOME ] button on keypad
Home Arm: Press button Remote Control Operation: Press [ ] button on remote controller once
Emergency Alarm: Press button, system will alarm at once. LCD display:
3.Out Arm
It means to guard all around your house while everyone is going out;
all the detectors of the host are always working; when the detector is
triggered by detecting source (anti-theft, fire prevention, gas leak, etc.),
the alarm system will sound the alarm.
Press [ARM] button on keypad, system will make a beep per second 5.Disarm
and totally 60 beeps. The [ARM] indicator will be on without flashing. It It means to stop the alarm when the main unit sounds the alarm or
means Out Arm is set successfully. make the alarm system in the state of non-warning. After disarming,
Main unit operation: Press [ARM] button, the system will enter arm even if you trigger the detector, the main unit would not sound alarm
(excluding 24-hour defense areas).
status 60seconds later or delay time set by user
Use keypad to input system password (Default: 1234), then press #
Remote controller operation: Press button on remote controller,
button. [ARM] or [HOME] lights will be off. It means disarm setting
system will enter OUT ARM mode immediately. successful.
SMS remote operation: The SMS command is: Remote Control Main Unit Operation: input system password + #
Password (Default: 1234) + [1] Remote Control Operation: Press [ ] button on remote controller
After the setting, the host makes a "Di" sound, ARM LED is on and you SMS remote operation: The SMS command is: Remote Control
will receive a SMS: System armed. Password (Default: 1234) + [2]
Note: SMS command can only be controlled by the preset three alarm After the setting, the host makes "Di" Di" sound, ARM LED is off and
SMS numbers. you will receive a SMS: System disarmed.
19 20
Operating Instructions Technical Parameters
will display the exact alarming time of this defense zone. Press 2, you
can upturn to check the previous alarming record; press 8, downturn to
check; and press [*#] to exit checking.
For example: the 51st defense zone; the 7th alarming; alarming time:
12:10, August 1st, 2008. LCD display for one second,
[Technical Parameters]
Power supply: AC=220V±10%
DC=12V (Built-in NI-HM) rechargeable battery
Standby Current: <60mA
and then display the alarming time: Alarming Current: <450mA
GSM band: 850/ 900/ 1800/ 1900MHz
Wireless Frequency: 315/ 433/ 868MHz±0.5MHz
Wireless receiving sensitivity: 5mV/m
Anti-interference: 1V/m (Frequency range: 20-1000MHZ)
Working Temperature: 10℃- 40℃ +
Humidity: ≤90% ( no fog)
You can also check the alarm records by SMS (Max: Latest 9 records). Wireless detectors: 99pcs
SMS Check Command: Remote Control Password (Default: 1234) + [3]
Alarm
Reply SMS: Defense Zone Arm Home Arm Type Siren
Information
Eg: Alarm record: Zone 1 effective invalid real-time Door alarm yes
NO1 Zone: 05 TIME: 11-06-25 11:37 Zone 2 effective invalid real-time Hall alarm yes
(It indicates the first record: wireless zone 5 alarm time) Zone 3 effective effective real-time Window alarm yes
……………. Zone 4 effective effective real-time Balcony alarm yes
NO9 Zone: 19 Time: 11-06-25 11:45 Zone 5 effective effective 24 hours Fire alarm yes
(It indicates the ninth record: wireless zone 19 alarm time) Zone 6 effective effective 24 hours Gas alarm yes
Emergency effective effective 24 hours Emergency NO
11.GSM Signal Checking button alarm
Before installing the main unit, you should check the signal of the Zone 7-94 effective invalid real-time Emergency yes
alarm
installing place in order to ensure the unit can perform well. In setup Emergency
Wired defense effective invalid real-time yes
state, input [81] [#], the main unit will make a long beep and display zone (95-97) alarm
00+XX (XX indicates the intensity of the GSM signal). And the intensity PIR on panel Emergency
effective effective real-time yes
should be within the range of 07-31; if it’s less than 07, you should (zone 98) alarm
change place. Tamper alarm Emergency yes
zone (99) effective effective 24 hours
alarm
This icon indicates the signal intensity. When the intensity number is
Program Password 8888 Remote control On
0-7, this icon will not be shown; when it’s 8-15, this icon will be
Operation Password 1234 Siren Off
flashing; when the number is larger than 16, this icon will be on the
Siren sound time 180 sec. Home Appliance Optional
screen without flash.
For example: if the signal intensity is 12, it will display as:
23 24
Components List Care and Maintenance
25 26
Care and Maintenance Care and Maintenance
27 28