Enter your personal identification number (PIN) and Press the [On] key for 3 seconds press [On]. If your system is programmed by the installer to allow Figure 1: Alarm Control Panel Quick Arm, hold the [On] key down for 3 seconds to start the arming mode. Disarming requires entering a User code (PIN) followed by pressing the [Off] key. 4.0 Cancel Alarm Enter PIN, press [Off] Enter a Master PIN code or a User PIN code and press the [Off] key to immediately stop the alarm output. 5.0 Panic Key [*][#]
Your system must be programmed at
installation to use this function.
During an emergency, simultaneously pressing the [*]
and [#] keys for 3 seconds produces an alarm. Entering a User code resets the panic alarm condition. 6.0 Alarm History Clear Enter a Master PIN code or a User PIN code. Press Press the [#] key for 3 seconds the [On] key. If the code was entered correctly, the While in the disarmed mode, press the [#] key for 3 red Armed indicator flashes and the system arms. seconds to cancel all flashing alarm history zone If your system has an exit delay zone, the sounder indicators. beeps during the exit period. The exit sounder beeps If an alarm occurs while the system is armed, the faster during the last 20 seconds of the programmed zone’s LED glows continuously. When the system is exit delay time. disarmed, the zone causing the alarm flashes its LED After the exit delay time expires, the red Armed indicator. While in the disarmed mode, pressing the indicator glows continuously. A violation on a zone, [#] key for 3 seconds resets the indicator. not programmed as a delay zone, immediately activates a system alarm. 2.0 Disarming the System Enter PIN, press [Off] Enter a Master PIN code or a User PIN code. Press the [Off] key. If a delay zone is triggered first, a code must be entered before the expiration of the entry delay time. The red Armed indicator LED stops flashing and turns off, indicating the system is disarmed. 7.0 Bypassing a Zone Table 1: Zone Status Enter PIN, press [Bypass], enter the zone number, and press [On] A user can bypass a zone during the arming NAME STATUS DESCRIPTION sequence if it was programmed at installation to Zone 1 On Zone 1 allow bypass. You can bypass a zone if the zone is alarmed/violated either faulted or normal. To bypass a zone, enter Off Zone 1 normal the User code or the Master code. Press the Flashing Zone 1 alarm [Bypass] key. Enter the zone number to bypass (0.5 seconds on, 0.5 history (such as, Zone 1, Zone 2, or Zone 3, or any seconds off) combination of Zones 1, 2, or 3). Flashes twice every 2 Zone 1 bypassed seconds For example: To enter Zone 1, press the [1] key, Zone 2 On Zone 2 then press the [On] key to begin the arming cycle alarmed/violated and exit delay, if programmed. All zones that were Off Zone 2 normal bypassed will clear and automatically restore to Flashing Zone 2 alarm their normal mode the next time the system (0.5 seconds on, 0.5 history disarms. seconds off) Once a zone is bypassed, the zone’s LED indicates Flashes twice every 2 Zone 2 bypassed its bypass status by flashing twice every 2 seconds. seconds Zone 3 On Zone 3 8.0 Fire Alarm Reset alarmed/violated Enter PIN, press [Reset] Off Zone 3 normal Use the Fire Reset for power interrupt and to reset Flashing Zone 3 alarm the smoke detectors. This function must be installed (0.5 seconds on, 0.5 history and programmed at installation. Only the Master seconds off) code user can perform this function. Flashes twice every 2 Zone 3 bypassed seconds 9.0 Door Un-Lock Code Armed Flashing Exit delay (0.5 seconds on; 0.5 Enter PIN, press [*] seconds off) If enabled, entering the Door Un-Lock User code On System armed and pressing the [*] key activates the Request to Off System disarmed Exit function, releasing any connected door lock. Power On Power supply normal Off No power supply