9 ELECTRONIC METERS FOR THE LUBRICANT SUPPLY AND MEASUREMENT

DESCRIPTION CODE

40 MGE-40 · ELECTRONIC OVAL GEAR METER 32200


L/MIN
- Flow: from 0,5 to 40l/min
- Electronic meter with aluminium measuring chamber, with high accuracy
oval gears, with rotary Display-LCD, which allows a 90º turn in relation to the
housing
MGE-40
- Partial indicator of 4 digits and 2 decimals, totalizer of 6 digits
- Automatic reset after 30 seconds. It stores the litres of the last service
- Maximum pressure: 80bar (security pressure)
- Maximum operation pressure: 50bar
- Min./Max. temperature: -5ºC / +60ºC
- Accuracy: +/- 0,5% + 2 digits
- It is suitable for the lubricant measuring up to SAE-140 density
- Inlet/outlet connection thread: F1/2" GAS (BSP)
- 1 calculator battery. Low battery alarm.
mm 100 Kg 0,65 - Calibration parameters and stored litre totalizer on a PERMANENT memory
(approx.) (approx.)
100 125
Optional
- RI-97 PRESET KIT. 32035
To make the preset on the MGE-40, it is necessary to install this kit.
Automatic stopping cable system to connect the meter and the 230VAC electric pump.

MGI-40 · PULSER 32280

Pulser to be assembled on line, facilitating the exact information to the fluid management
MGI-40 and control systems; it is the most sophisticated that those are currently in the market.
mm 100 - Flow: from 0,5 to 40l/min
(approx.)
125 - Inlet/outlet connections: F1/2" GAS (BSP)
100
- Housing: Aluminium
Kg 0,65 - Cover: Polyamide + Fibreglass
(approx.)
- Maximum pressure: 80bar (security pressure)
- Maximum operation pressure: 50bar
- Pulses: 2 180º phased out channels, 78 pulses per channel, 156 pulses per litre

MGE-150 · ELECTRONIC METER


150 - Aluminium high flow lubricant and diesel meter (please, consult other liquids)
L/MIN
- Flow: from 5 to 150l/min
MGE-150 - It works through oval gears of +/- 0,5% high accuracy
- Indicator of 4 digits and 2 decimals
- Total and partial of supplied litres
- Automatic stop after 30 seconds. It memorizes the litres of the last service
- Min./Max. temperature: -5ºC / +60ºC
- Accuracy: +/- 0,5 + 2 digits
- Inlet/outlet connection thread: F1" GAS (BSP) with aluminium flanges
- 2 batteries 1,5VDC alkaline AA. Low battery alarm
- Calibration parameters and stored litre totalizer on a PERMANENT memory
- Calibration access code
- Maximum operation pressure: 50bar

MGE-150 · Inlet-outlet 1" 32500


MGE-150 · Inlet-outlet 1 1/2" 32520
mm 170 Kg 4,9
(approx.) (approx.)
116 104 Optional
- RI-97 PRESET KIT. To make the preset and the self-stopping, it is necessary to 32035
install this kit.

MGI-150
MGI-150 · PULSER 32510

Pulser to be assembled on line, facilitating the exact information of the fluid management
mm 170
(approx.) and control systems.
116 104 - Flow: from 5 to 150l/min
- Inlet/outlet connections: F1" GAS (BSP)
Kg 4,9
(approx.) - Housing and cover: Aluminium
- Two communication channels through REEDS
- Pulses: 2 180º phased out channels, 11 pulses per channel, 22 pulses per litre