1 Introduction
The aim of this document is to give you an overview of
Phoenix Contact controllers for control system technology.
The following pages list basic controller specifications from
the Phoenix Contact controller range - broken down into
controller classes. The table on the following pages lists the
ordering data of the various controllers.

Figure 1 All controller classes

Make sure you always use the latest documentation.


It can be downloaded at phoenixcontact.net/products.

This application note is valid for all products listed in the ordering data.
BASIC DATA PHOENIX CONTACT PLC

2 Ordering data
Description Type Order No. Pcs./Pkt.
Inline controller with 10/100 Ethernet interface, ILC 130 ETH 2988803 1
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, Modbus/TCP, ILC 131 ETH 2700973 1
PROFINET device, including accessories (connectors and labeling fields)
Inline controller for use under extreme environmental conditions, ILC 131 ETH/XC 2701034 1
with 10/100 Ethernet interface, Modbus/TCP,
PROFINET device, including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, ILC 150 ETH 2985330 1
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, Modbus/TCP, ILC 151 ETH 2700974 1
PROFINET device, including accessories (connectors and labeling fields)
Inline controller for use under extreme environmental conditions, ILC 151 ETH/XC 2701141 1
with 10/100 Ethernet interface, Modbus/TCP,
PROFINET device, including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, PROFINET device ILC 170 ETH 2TX 2916532 1
including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, Modbus/TCP, ILC 171 ETH 2TX 2700975 1
PROFINET device, including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, Modbus/TCP, ILC 191 ETH 2TX 2700976 1
PROFINET device, floating point unit
including accessories (connectors and labeling fields)
Inline controller with integrated pulse/direction/PWM interface, ILC 191 ME/AN 2700074 1
RS-485/RS-422, analog inputs (0 ... 0 V), and analog outputs (0 ... 10 V),
2 x 10/100 Ethernet interfaces, Modbus/TCP, PROFINET device
Inline controller with integrated pulse/direction/PWM interface, ILC 191 ME/INC 2700075 1
RS-485/RS-422, fast counters, and incremental encoder inputs,
2 x 10/100 Ethernet interfaces, Modbus/TCP, PROFINET device
Inline controller with 10/100 Ethernet interface and GSM modem, ILC 151 GSM/GPRS 2700977 1
Modbus/TCP, including accessories (connectors and labeling fields)
Inline controller, ILC 200 IB-PAC 2862288 1
including accessories (connectors and labeling fields)
Inline controller with an INTERBUS local bus interface for the Inline installation ILC 200 UNI-PAC 2862291 1
system, with programming facility in acc. with IEC 61131-3,
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, ILC 330 ETH 2737193 1
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, ILC 330 PN 2988191 1
PROFINET controller,
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, ILC 350 ETH 2737203 1
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, ILC 350 ETH/M 2985819 1
meets the requirements of maritime registers of shipping,
including accessories (connectors and labeling fields)
Inline controller with 10/100 Ethernet interface, ILC 350 PN 2876928 1
PROFINET controller,
including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, ILC 370 ETH 2TX-IB 2876999 1
including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, ILC 370 PN 2TX-IB 2876915 1
PROFINET controller,
including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, ILC 370 PN 2TX-IB/M 2985576 1
PROFINET controller,
meets the requirements of maritime registers of shipping,
including accessories (connectors and labeling fields)
Inline controller with 2 x 10/100 Ethernet interfaces, ILC 390 PN 2TX-IB 2985314 1
PROFINET controller,
including accessories (connectors and labeling fields)
Remote Field Controller with 1 x 10/100 Ethernet interface, INTERBUS RFC 430 ETH-IB 2730190 1
master, IP20 protection, and plug-in parameterization memory

8007_en_04 PHOENIX CONTACT 2 / 12


BASIC DATA PHOENIX CONTACT PLC

Description Type Order No. Pcs./Pkt.


Remote Field Controller with 1 x 10/100 Ethernet interface, INTERBUS RFC 450 ETH-IB 2730200 1
master, IP20 protection, and plug-in parameterization memory
Remote field controller for Ethernet/PROFINET networks for creating a RFC 460R PN 3TX 2700784 1
redundant control system, with 3 x 10/100 Ethernet interfaces,
PROFINET controller, IP20 degree of protection, and plug-in parameterization
memory
Remote Field Controller with 3 x 10/100 Ethernet interfaces, INTERBUS RFC 470 PN 3TX 2916600 1
master, PROFINET controller, PROFINET device, IP20 protection, and plug-
in parameterization memory
Remote Field Controller with integrated PROFIsafe controller, INTERBUS RFC 470S PN 3TX 2916794 1
master, PROFINET controller, PROFINET device, IP20 protection, and plug-
in parameterization memory
Controller for Axioline F with 2 x 10/100 Ethernet interfaces, Modbus/TCP, AXC 1050 2700988 1
PROFINET device, PROFINET controller, floating point unit
including accessories (connectors and labeling fields)
Controller for Axioline F for use under extreme environmental conditions with AXC 1050 XC 2701295 1
2 x 10/100 Ethernet interfaces, Modbus/TCP,
PROFINET device, PROFINET controller, floating point unit
including accessories (connectors and labeling fields)
Controller for Axioline F with 3 x 10/100 Ethernet interfaces, Modbus/TCP, AXC 3050 2700989 1
PROFINET device, PROFINET controller, floating point unit
including accessories (connectors and labeling fields)
Software PLC PC WORX RT BASIC 2700291 1
Software PLC, Modbus/TCP, PROFINET PC WORX SRT 2701680 1

8007_en_04 PHOENIX CONTACT 3 / 12


8007_en_04 3 100 controller class

Number of connections as Modbus/

Number of connections as Modbus/


Ethernet connections through UDP/

Number of web server connections


Number of INTERBUS remote bus

Switching of INTERBUS devices

PLC program memory [Kbytes]


Number of INTERBUS devices

Processing speed for 1 K mix

communication connections
Processing speed for 1 K bit

PLC retain memory [Kbytes]

PROFINET device functions


PLC data memory [Kbytes]
Release firmware version 1

(IEC 61131-5 compliant) 3

(PROFINET controllers)
PROFINET connections
Simultaneous external
Ethernet connections
FTP server functions

Download changes

(recommended) 4
(recommended)
PCP devices

IP / TCP/IP 2
instructions

instructions

TCP server
TCP client
Controller

devices

ILC 130 ETH 3.94 63 0 8 Yes Yes 90 μs 1.7 ms 192 192 8 Yes 8 8 4 4 – – – –
ILC 131 ETH 4.42 63 0 8 Yes Yes 90 μs 1.7 ms 192 192 8 Yes 8 8 4 4 – Yes 4 4
ILC 131 ETH/XC 4.42 63 0 8 Yes Yes 90 μs 1.7 ms 192 192 8 Yes 8 8 4 4 – Yes 4 4
ILC 150 ETH 3.94 128 32 16 Yes Yes 90 μs 1.5 ms 256 256 8 Yes 8 8 4 4 – – – –
ILC 151 ETH 4.42 128 32 16 Yes Yes 90 μs 1.5 ms 256 256 8 Yes 8 8 4 4 – Yes 8 6
ILC 151 ETH/XC 4.42 128 32 16 Yes Yes 90 μs 1.5 ms 256 256 8 Yes 8 8 4 4 – Yes 8 6
ILC 170 ETH 2TX 3.94 128 32 24 Yes Yes 90 μs 1.5 ms 512 512 48 Yes 16 8 4 4 – Yes – –
ILC 171 ETH 2TX 4.42 128 32 24 Yes Yes 90 μs 1.5 ms 512 512 48 Yes 16 8 4 4 – Yes 16 8
ILC 191 ETH 2TX 4.42 128 32 24 Yes Yes 90 μs 1.3 ms 1024 1024 48 Yes 16 8 4 4 – Yes 16 8

BASIC DATA PHOENIX CONTACT PLC


ILC 191 ME/AN 4.42 128 32 24 Yes Yes 90 μs 1,3 ms 1024 1024 48 Yes 16 8 4 4 – Yes 16 8
ILC 191 ME/INC 4.42 128 32 24 Yes Yes 90 μs 1,3 ms 1024 1024 48 Yes 16 8 4 4 – Yes 16 8
ILC 151 GSM/GPRS 4.42 128 32 16 Yes Yes 90 μs 1.5 ms 512 512 48 Yes 8 8 4 4 – – 8 6
1 The basic data given here is valid for the individual controllers with the specified firmware version or later
2
Max. number of Ethernet connections without using IEC 61131-5-compliant communication
PHOENIX CONTACT

3
Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP
4 External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)
4 / 12
8007_en_04 4 200 controller class

Number of web server connections


Switching of INTERBUS devices

PLC program memory [Kbytes]

Ethernet connections through

communication connections

PROFINET device functions


Release firmware version 1

(IEC 61131-5 compliant) 3

(PROFINET controllers)
PROFINET connections
Simultaneous external
Ethernet connections
Processing speed for
FTP server functions

1 K mix instructions

PLC retain memory

Download changes
INTERBUS version

PLC data memory

(recommended) 4
UDP/IP / TCP/IP 2

(recommended)
PCP devices
Controller

[Kbytes]

[Kbytes]
ILC 200 IB-PAC 4.6 C G4 62 Yes No 1.3 ms 380 330 8 No – – – – – –
ILC 200 UNI-PAC 4.6 C G4 62 Yes No 1.3 ms 380 330 8 No – – – – – –
1 The basic data given here is valid for the individual controllers with the specified firmware version or later
2
Max. number of Ethernet connections without using IEC 61131-5-compliant communication
3
Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP
4 External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)

BASIC DATA PHOENIX CONTACT PLC


PHOENIX CONTACT
5 / 12
8007_en_04 5 300 controller class

Number of web server connections


Switching of INTERBUS devices

PLC program memory [Mbytes]

Ethernet connections through

communication connections
PLC retain memory [Kbytes]

PROFINET device functions


Release firmware version 1

PLC data memory Mbytes]

(IEC 61131-5 compliant) 3

(PROFINET controllers)
PROFINET connections
Simultaneous external
Ethernet connections
Processing speed for

Processing speed for


FTP server functions

1 K mix instructions

Download changes
1 K bit instructions
INTERBUS version

(recommended) 4
UDP/IP / TCP/IP 2

(recommended)
PCP devices
Controller

ILC 330 ETH 3.52 G4 62 Yes Yes 11 μs 0.7 ms 0.75 1.5 64 Yes 32 32 6 4 – –
ILC 330 PN 3.53 G4 62 Yes Yes 11 μs 0.7 ms 0.75 1.5 64 Yes 32 32 6 4 100 Yes
ILC 350 ETH 3.52 G4 62 Yes Yes 9 μs 0.5 ms 1 2 64 Yes 32 32 6 4 – –
ILC 350 ETH/M 3.52 G4 62 Yes Yes 9 μs 0.5 ms 1 2 64 Yes 32 32 6 4 – –
ILC 350 PN 3.53 G4 62 Yes Yes 9 μs 0.5 ms 1 2 64 Yes 32 32 6 4 100 Yes
ILC 370 ETH 2TX-IB 3.52 G4 62 Yes Yes 7 μs 0.3 ms 2 4 96 Yes 32 32 6 4 – –
ILC 370 PN 2TX-IB 3.55 G4 62 Yes Yes 7 μs 0.3 ms 2 4 96 Yes 32 32 6 4 100 Yes
ILC 370 PN 2TX-IB/M 3.55 G4 62 Yes Yes 7 μs 0.3 ms 2 4 96 Yes 32 32 6 4 100 Yes
ILC 390 PN 2TX-IB 3.55 G4 62 Yes Yes 6 μs 0.2 ms 2 4 96 Yes 32 32 6 4 100 Yes
1
The basic data given here is valid for the individual controllers with the specified firmware version or later

BASIC DATA PHOENIX CONTACT PLC


2 Max. number of Ethernet connections without using IEC 61131-5-compliant communication
3
Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP
4
External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)
PHOENIX CONTACT
6 / 12
8007_en_04 6 400 controller class

Number of web server connections


Switching of INTERBUS devices

PLC program memory [Mbytes]

Ethernet connections through

communication connections
PLC retain memory [Kbytes]

PROFINET device functions


PLC data memory [Mbytes]
Release firmware version 1

(IEC 61131-5 compliant) 3

(PROFINET controllers)
PROFINET connections
Simultaneous external
Ethernet connections
Processing speed for

Processing speed for


FTP server functions

1 K mix instructions

Download changes
1 K bit instructions
INTERBUS version

(recommended) 4
UDP/IP / TCP/IP 2

(recommended)
PCP devices
Controller

RFC 430 ETH-IB 5.06 G4 126 Yes – – 0.1 ms 2 4 96 Yes 16 16 0 4 – –


RFC 450 ETH-IB 5.06 G4 126 Yes – – 0.05 ms 8 16 96 Yes 16 16 0 4 – –
RFC 460R PN 3TX 5.06 – – – Yes 2 μs 0.007 ms 8 16 120 Yes 32 32 10 20 256 –
RFC 470 PN 3TX 4.10 G4 62 Yes Yes 1 μs 0.005 ms 8 16 240 Yes 32 32 10 20 256 Yes
RFC 470S PN 3TX 4.10 G4 62 Yes Yes 1 μs 0.005 ms 8 16 240 Yes 32 32 10 20 256 Yes
1 The basic data given here is valid for the individual controllers with the specified firmware version or later
2
Max. number of Ethernet connections without using IEC 61131-5-compliant communication
3
Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP
4 External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)

BASIC DATA PHOENIX CONTACT PLC


PHOENIX CONTACT
7 / 12
8007_en_04 7 1000 controller class

Number of web server connections


Number of connectable local bus

PLC program memory [Kbytes]

Ethernet connections through

communication connections
PLC retain memory [Kbytes]

PROFINET device functions


PLC data memory [Kbytes]
Release firmware version 1

(IEC 61131-5 compliant) 4

Number of Modbus/TCP
(PROFINET controllers)
PROFINET connections
Simultaneous external
Ethernet connections
Processing speed for

Processing speed for


FTP server functions

1 K mix instructions

Download changes
1 K bit instructions

(recommended) 5
UDP/IP / TCP/IP 3

(recommended)

connections
Controller

devices2
AXC 1050 2.10 Yes 63, max. 75 μs 1,0 ms 1024 2048 48 Yes 16 8 4 4 8 Yes 16
AXC 1050 XC 2.10 Yes 63, max. 75 μs 1,0 ms 1024 2048 48 Yes 16 8 4 4 8 Yes 16
1
The basic data given here is valid for the individual controllers with the specified firmware version or later
2 Observe the current consumption of each Axioline F device. The number of local bus devices that can be connected depends on the specific structure of the Axioline F station.
3
Max. number of Ethernet connections without using IEC 61131-5-compliant communication
4
Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP
5 External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)

BASIC DATA PHOENIX CONTACT PLC


PHOENIX CONTACT
8 / 12
8007_en_04 8 3000 controller class

Number of web server connections


Number of connectable local bus

PLC program memory [Kbytes]

Ethernet connections through

communication connections
PLC retain memory [Kbytes]

PROFINET device functions


PLC data memory [Kbytes]
Release firmware version 1

(IEC 61131-5 compliant) 4

Number of Modbus/TCP
(PROFINET controllers)
PROFINET connections
Simultaneous external
Ethernet connections
Processing speed for

Processing speed for


FTP server functions

1 K mix instructions

Download changes
1 K bit instructions

(recommended) 5
UDP/IP / TCP/IP 3

(recommended)

connections
Controller

devices2
AXC 3050 5.50 Yes 63, max. 1 μs 3 μs 4096 8128 128 Yes 32 32 10 20 256 Yes 32
1 The basic data given here is valid for the individual controllers with the specified firmware version or later
2
Observe the current consumption of each Axioline F device. The number of local bus devices that can be connected depends on the specific structure of the Axioline F station.
3
Max. number of Ethernet connections without using IEC 61131-5-compliant communication
4 Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP
5
External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)

BASIC DATA PHOENIX CONTACT PLC


PHOENIX CONTACT
9 / 12
8007_en_04 9 Software PLC

Simultaneous external communication

Number of Modbus/TCP connections


Number of web server connections
Switching of INTERBUS devices 2)

PLC program memory [Mbytes]

connections (recommended) 5
Ethernet connections through
Optional INTERBUS version 2

PLC retain memory [Kbytes]

PROFINET device functions


PLC data memory [Mbytes]
Release software version 1

(IEC-61131-5 compliant) 4

(PROFINET controllers)
PROFINET connections
Ethernet connections
Processing speed for

Processing speed for


FTP server functions

1 K mix instructions

Download Changes
1 K bit instructions
Hardware platform

UDP/IP / TCP/IP 3

(recommended)
PCP devices2)
Controller

INTEL® 6
PC WORX RT BASIC 1.1 G4 62 Yes Yes 0.7 μs 0.001 ms 8 16 240 Yes 32 32 10 20 256 Yes
Core™2 Duo
INTEL® 6)
PC WORX SRT 1.23 – – – Yes 0,7 μs 0,001 ms 1 1 48 Yes 32 32 10 20 8 Yes
Core™2 Duo
1
The basic data given here is valid for the specified hardware platform with the relased software version or later.
2 The values depend on the hardware and firmware version of the INTERBUS controller group used
3
Max. number of Ethernet connections without using IEC 61131-5-compliant communication
4
Max. number of Ethernet connections without using communication through UDP/IP / TCP/IP

BASIC DATA PHOENIX CONTACT PLC


5 External communication connections (SOCOMM interface, e.g., OPC communication, data exchange between PC Worx and the controller)
6
The number of possible Modbus/TCP connections depends on the hardware used.
PHOENIX CONTACT
10 / 12
BASIC DATA PHOENIX CONTACT PLC

10 Accessories
Description Type Order No. Pcs. / Pkt.
Parameterization memory, plug-in (CompactFlash card), 256 Mbytes CF FLASH 256MB 2988780 1
Parameterization memory, plug-in (CompactFlash card), 2 Gbytes CF FLASH 2GB 2701185 1
Parameterization memory, plug-in (CompactFlash card), 256 Mbytes CF FLASH 256MB APPLIC A 2988793 1
with license key for the function block libraries
Parameterization memory, plug-in (CompactFlash card), 2 Gbytes CF FLASH 2GB APPLIC A 2701189 1
with license key for the function block libraries
Parameterization memory, plug-in (CompactFlash card), 256 Mbytes CF FLASH 256MB PDPI BASIC 2700549 1
with license key for the licensing of PDPI controller blocks
Parameterization memory, plug-in (CompactFlash card), 256 Mbytest CF FLASH 256MB PDPI PRO 2700550 1
with license key for the licensing of PDPI controller blocks
Fan module for Remote Field Controller RFC DUAL-FAN 2730239 1
Connecting cable (length: 3 m) IBS PRG CAB 2806862 1
RS-232 null modem connector PSM-AD-D9-NULLMODEM 2708753 1
VARIOFACE initiator module FLKMS 14/8IM/LA/PLC 2284536 1
Round cable, assembled (with two 14-pos. female connectors; length: 2 m) FLK 14/EZ-DR/ 200/KONFEK 2288930 1
Connecting cable, for connecting the controller to a PC (RS-232) for PC COM CAB MINI DIN 2400127 1
WORX with flow control, 3 m in length
Parameterization memory, plug-in (SD memory card), 512 Mbytes SD FLASH 512MB 2988146 1
Parameterization memory, plug-in (SD memory card), 2 Gbytes SD FLASH 2GB 2988162 1
Parameterization memory, plug-in (SD memory card), 512 Mbytes, SD FLASH 512MB APPLIC A 2701799 1
with license key for the function block libraries
Parameterization memory, plug-in (SD memory card), 2 Gbytes, SD FLASH 2GB APPLIC A 2701190 1
with license key for the function block libraries
Program and configuration memory, plug-in, 512 Mbytes with license key for SD FLASH 512MB PDPI BASIC 2701800 1
licensing the PDPI - BASIC functional block for precise multi-channel
controllers with self-optimization, e.g., for heating and cooling functions or
hydraulic movements
Program and configuration memory, plug-in, 512 Mbytes with license key for SD FLASH 512MB PDPI PRO 2701801 1
licensing the PDPI - PRO functional block for precise multi-channel controllers
with self-optimization, additional functions: e.g., for setpoint processing, for
heating and cooling functions
GSM-UMTS antenna with with omnidirectional characteristics, PSI-GSM/UMTS-QB-ANT 2313371 1
antenna cable with SMA round connector (length: 2 m)
Multiband mobile phone antenna with mounting bracket for outdoor TC ANT MOBILE WALL 5M 2702273 1
installation. 5 m antenna cable with SMA round plug
Controller board in the PCI format, with electrical isolation IBS PCI SC/I-T 2725260 1

Use memory cards of the types


SD FLASH 512MB APPLIC A / SD FLASH 2GB APPLIC A or
CF FLASH 256MB APPLIC A / CF FLASH 2GB APPLIC A
when you use function block libraries which are not free of charge.
An overview of further memory cards with different license keys can be found on the Internet at:
phoenixcontact.net/products.

8007_en_04 PHOENIX CONTACT 11 / 12


BASIC DATA PHOENIX CONTACT PLC

11 Documentation
Description Type Order No. Pcs. / Pkt.
User manual UM EN ILC 1XX – 1
Installing and operating the ILC 130 ETH, ILC 150 ETH, ILC 155 ETH,
ILC 170 ETH 2TX und ILC 190 ETH 2TX Inline controllers
User manual UM EN ILC 1X1 – 1
Installing and operating the ILC 131 ETH, ILC 151 ETH, ILC 171 ETH 2TX,
ILC 191 ETH 2TX, ILC 131 ETH/XC and ILC 151 ETH/XC Inline controllers
User manual UM EN ILC 191 ME/X – 1
Installing and operating the ILC 191 ME/AN and ILC 191 ME/INC Inline
controllers
User manual UM EN ILC 151 GSM/GPRS – 1
Installing, starting up, and operating the ILC 151 GSM/GPRS Inline controller
User manual ILC 200 IB UM E – 1
Installation and startup of the ILC 200 IB Inline controller
User manual ILC 200 UNI UM E – 1
IInstalling and operating the ILC 200 UNI Inline controller
User manual UM EN ILC 330/350 – 1
Installing and operating the ILC 330 ETH, ILC 350 ETH, ILC 350 ETH/M and
ILC 350 PN Inline controllers
User manual UM EN ILC 370/390 – 1
Installing and operating the ILC 370 ... und ILC 390 ... Inline controllers
User manual UM EN RFC 460R PN 3TX – 1
Installing and operating the RFC 460R PN 3TX Remote Field Controller as a
redundant control system
User manual UM EN RFC 470 PN 3TX – 1
Installation and operation of the RFC 470 PN 3TX Remote Field Controller
User manual UM EN RFC 470S PN 3TX 2910813 1
Installation and operation of the RFC 470S PN 3TX Remote Field Controller
with integrated PROFINET controller
User manual RFC 430/450 ETH-IB UM E – 1
Installing and starting up remote field controllers with Ethernet connection
User manual UM EN AXC 1050 (XC) – 1
Installing and operating the AXC 1050 and AXC 1050 XC controllers
User manual UM EN AXC 3050 – 1
Installing and operating the AXC 3050 controller
Application note AH EN FIRMWARE UPDATE ILC 1.../ – 1
Information on updating the firmware to version 1.13 or later for the controllers 3..., RFC 4...
listed in this document
User manual UM EN PC WORX RT BASIC – 1
Installing and operating the PC WORX RT BASIC Software PLC with Valueline
industrial PCs and PROFINET
User manual UM EN PC WORX SRT – 1
Installing and operating the PC WORX SRT Software PLC

8007_en_04 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany 12 / 12