BRAVO HOME UPS


HOME UPS (300VA -10KVA)

INDEPENDENT CHARGER FOR


DEEP DISCHARGE BATTERY RECOVERY

15 Ampere Battery Charge Complete Protection


From Back Feed And User friendly
Current For Faster at very low
Battery Charging Phase To Phase Interface.
Voltage till 90V.
Supply.

www.smartenpowersystems.com
PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATION

Model Name Bravo 300 Bravo 500 Bravo 700 Bravo 900 Bravo 1100 Bravo 1700 Bravo 2000 Bravo 2500 Bravo 3500 Bravo 5000 Bravo 5000 Bravo 6000 Bravo 7500 Bravo 10000

Mains Input mode


Mains AC low cut UPS mode 175VAC ± 10VAC

Mains AC low cut recovery UPS mode 185VAC ± 10VAC

Mains AC high cut UPS mode 265VAC ± 10VAC

Mains AC high cut recovery UPS mode 255VAC ± 10VAC

Mains AC low cut WUPS mode 90VAC ± 10VAC

Mains AC low cut recovery WUPS mode 110VAC ± 10VAC

Mains AC high cut WUPS mode 295VAC ± 10VAC

Mains AC high cut recovery WUPS mode 285VAC ± 10VAC

Input Frequency Range 40Hz to 60Hz

Battery
Battery Type LA / Tubular / SMF

DC input voltage 12V 24V 36V 48V 48V 96V 72V 96V 120V

Battery deep Discharge Recovery Yes (Independent Charger to Recover Deep Discharge Battery)
Charging Current 100Ah-135Ah Settting (Input range 6.5A ± 1A (50-80Ah
12A ± 1A
135VAC to 295VAC) Battery)
Charging Current 150Ah-220Ah Settting (Input range 10A ± 1A(100-135Ah
15A ± 1A
135VAC to 295VAC) Battery)
Boost charging voltage for LA Battery 14.0V±0.2V 28.0V±0.2V 42V±0.2V 56.0V±0.4V 56.0V±0.4V 112V±0.4V 84.0V±0.4V 112V±0.4V 140V±0.4V

Boost charging voltage for Tubular and SMF Battery 14.5V±0.2V 29.0V±0.2V 43.5V±0.2V 58.0V±0.4V 58.0V±0.4V 116V±0.4V 87.0V±0.4V 116V±0.4V 145V±0.4V

Backup Mode
Output voltage 220VAC +5% -10% (untill battery low alarm)

Output frequency 50Hz ± 0.2 Hz

Output waveform Pure Sine Wave

Capacity 300VA 500VA 700VA 900VA 1100VA 1700VA 2000VA 2500VA 3500VA 5000VA 5000VA 6000VA 7500VA 10000VA

Low Battery Warning 11V±0.2V 22V±0.2V 33V±0.2V 44V±0.4V 44V±0.4V 88V±0.4V 66V±0.4V 88V±0.4V 110V±0.4V

Low Battery Cut 10.6V±0.2V 21.6V±0.2V 32.4V±0.2V 43.2V±0.4V 43.2V±0.4V 86.4V±0.4V 64.8V±0.4V 86.4V±0.4V 108V±0.4V

Change over time UPS mode < 10msec

Change over time WUPS mode < 25msec

Protections
Overload /Short Ckt. in backup mode Available

Backfeed System will shutdown in case of backfeed and there is no retry


Over temperature Available

Reverse Battery Available Battery MCB will trip

Phase to Phase protection in mains mode Available

Display and Alarms


LCD Status Display Mains ON, Input -Voltage/ Frequency, Battery -Voltage/Charging/Charged, UPS ON-OFF, Load,Output Voltage etc and all fault messages

Buzzer Audible beep for all protections

Environment
Operating Temperature

Storage Temperature
90% Non-Condensing
Operating Relative Humidity

Weight and Dimentions


Dimensions in mm 301x297x160 270x190x125 340x230x260 350x230x310 530x360x585 530x360x585 530x360x585 550x410x650 550x410x650

Weight 6.5Kg 8Kg 8.5kg 9.35kg 9.5kg 15.9kg 18.5kg 21.4kg 26.3kg 43kg 43kg 51kg 73kg 78kg