Professional Documents
Culture Documents
Notes Introduction
The PY60 works with both J and K type thermocouples
to provide accurate monitoring of temperatures from -
20 deg C up to 1100 deg C (-4 to 2012 deg F). High
and low temperature alarms can be set from 0 to 1100
deg C (32 to 2012 deg F). A built-in 85 dB alarm buzzer
sounds to warn you of problems. The highest tempera-
ture seen is automatically saved to a nonvolatile memory
and can be displayed/reset at any time. Five levels of
backlighting can be selected and all setup and calibration
constants are saved to a nonvolatile memory. The PY60
outputs NMEA 0183 serial data of temperature at 4800
baud. This information can be sent to a computer for use
in data logging or remote display. If not required, the
NMEA line can be programmed as an external alarm
output. The PY60 works on any voltage from 9.5 to
33.0 VDC and draws only 0.018 amps.
Page 14 Page 3
Table of Contents Other CruzPro Products
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 l Depthsounders & Speed/Temperature/Log
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 l DC Volts/Amps/Amp-Hour Monitor
l AC Volts/Amps//Freq/kW Monitor
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 l LPG/Petrol Gas Detectors/Alarms
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 l Bilge Water Alarms & Bilge Pump Controllers
Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 l Windlass Controller/Chain Counter
Backlight On/Off Control & Intensity . . . . . . . . . . . . . 8 l Digital Fuel Gauge & Fuel Consumption Calculator
Display Temperature . . . . . . . . . . . . . . . . . . . . . . 8 l Digital Gauge for Three Tanks /w Separate Alarms
Display Maximum Temperature . . . . . . . . . . . . . 9 l Smart and Manual Alternator Regulators
Resetting the Max Temperature . . . . . . . . . . . . . 9 l Marine Security System
Setting the Low Temperature Alarm . . . . . . . . . . . . . 9 l RPM/Engine Hours/Elapsed Time Gauge
Setting the High Temperature Alarm . . . . . . . . . . . . . 10 l Digital Oil Pressure Gauge/Alarm
Turning the Alarms ON/OFF . . . . . . . . . . . . . 10 l Digital Water Temperature Gauge/Alarm
Selecting Degrees F or C . . . . . . . . . . . . . . . . . 10 l One and Three Bank Digital Volts Gauges
Setting the Zero C (32 F) Point . . . . . . . . . . . . . 11 l Digital Amps Gauge
Calibrating Temperature . . . . . . . . . . . . . . . . . 11 l Digital Clock/Watch/Race Timers/Alarms
l 8 and 16 Amp Light Dimmers / Motor Speed Controller
NMEA 0183 or External Alarm Output . . . . . . . 12 l Solar Panel Charge Controllers 6/8/9 & 20 Amps
Other CruzPro Products . . . . . . . . . . . . . . . . . . . 15 l 4 & 8 Channel NMEA Combiners/RS-232 Convertors
2000 BV Engineering PY60MANG l Engine/Exhaust Temp. Monitor & Digital Pyrometer
http://www.cruzpro.com info@cruzpro.com l NMEA 0183 Remote Data Repeater/w 4 Input Channels
Page 2
Operating temperature: 32 to 122 F ( 0 to 50 C) If the External Alarm Output is selected, the output
Size: 61mm dia. x 104 mm (2.5" X 4.1" deep ). on screw terminal pin B will go high (+4.5 VDC)
when an alarm condition exists and the alarms are
Thermocouple: Type J or K turned ON. The output will be low (0 VDC) when
Measurement Range: -20 to 1100 deg C (-4 to the alarms are turned OFF or when no alarm condi-
2012 deg F) tion exists. The output is protected with a 270 ohm
resistor, limiting output current from the External
Temperature Accuracy: Better than +/- 1 % (front Alarm Output to about 15 mA (0.015 Amps).
panel adjustable)
Alarms: High and Low temperature settable from
0 to 1100 deg C (32 to 2012 deg F).
Display: 4 digit LCD, 5 levels of backlighting.
Outputs: NMEA 0183 serial data or External
Alarm Output (programmable).
Page 4 Page 13
NMEA 0183 or External Alarm Output Installation
The output on screw terminal pin B is factory set as
Before starting the installation, please read this
a digital serial data output at 4800 BAUD (Standard
entire section first. Be sure to install the bulkhead
NMEA 0183 format). You can toggle pin B
gasket before you install the instrument. Finger
between NMEA and External Alarm Output by
pressing and holding both the t and s keys for ten tighten the screws that mount the instrument bracket
seconds (till you hear the long beep). The selection - do not use tools.
is automatically saved to nonvolatile memory. Finger tighten only - Do not use tools
Setting the High Temperature Alarm l Carefully check all your wiring and if every-
To set the High Temperature Alarm, press and hold thing is wired correctly you can mount the PY60 in the
the s key for ten seconds (until you hear a long instrument hole. Be sure the bulkhead gasket is in place
beep). Use the t and s keys to set the desired value. and use only finger tension to tighten the bracket hold-
Press the : key to save the new value to memory. down nuts Do not overtighten the bracket or you
may damage the case - do not use tools to tighten the
Turning the Alarms ON/OFF nuts.
Press the s key for 1/2 second to turn the alarms ON.
Press the t key for 1/2 second to turn the alarms
OFF.