TTDJ Series
■ Alarm and Shutdown Control System for Engine-
Driven Pumps and Compressors
■ Monitors 32, User-Configurable, Sensor Inputs
from N.O. and/or N.C. Sensors
■ RS485 Serial Communications Port (DC Models)
■ Built-In Power Supply and Elapsed Time Meter
(Hour Meter) All Models
■ Models with Tachometer and Overspeed Available
■ Powered by 12/24VDC or CD Ignition (neg. grnd.)
■ CSA Certified for Use in Class I,
US Patent 6,144,116 Division 2, Hazardous Areas
(model TTDJ-IGN-T only)
C US
MurCal
c ground CD ignition; approx. 650µA @ 100VDC.
*Alarm Before Shutdown is a function that causes annunciation and the alarm
output, but will not cause a shutdown.
P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com
TTDJ Module Dimensions
5-1/4 in.
SENSOR RPM (133 mm)
6-1/2 in.
READ (165 mm)
HOURS
RESET RUN
STOP
MurCal
c
RE
GI
STER
E
P:(661)272-4700 F:(661)947-7570
www.murcal.com e-mail: sales@murcal.com
Printed in U.S.A.
TTDJ-99061B page 2 of 2
TTDJ-99062N
WARNING
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
✔ Disconnect all electrical power to the machine.
✔ Make sure the machine cannot operate during installation. US Patent 6,144,116
(model TTDJ-IGN-T only)
✔ Follow all safety warnings of the machine manufacturer. C US
✔ Read and follow all installation instructions.
CSA Certified for Use in Class I, Div. 2,
Groups C and D Hazardous Areas.
Description Liquid Crystal Display
The TTDJ is a solid-state fault annunciator and shutdown control system, The Liquid Crystal Display sequentially provides shutdown/alarm
with hour meter, designed to protect engines, compressors and their associ- condition, run hours, rpm, and timer information. A shutdown or
ated equipment. Four TTDJ modules are available: alarm condition is indicated by the appropriate sensor number in
TTDJ-DC : Powered by 12 or 24 VDC systems without tachome- the first two leftmost digits. Hours display uses all the digits. RPM
ter and overspeed sensing. Includes RS485 serial port. display is shown in the rightmost digits with a Run Indicator in the first
digit. The Timer display shows the timer number in the first digit and the
TTDJ-DC-T : Powered by 12 or 24 VDC systems with internal time in the last three digits.
tachometer and overspeed sensing. Includes RS485 serial port.
TTDJ-IGN : Powered by negative ground CD ignition systems Timers
without tachometer and overspeed sensing. Without RS485 port. Active Timers are indicated by the timer number in the first digit of the dis-
TTDJ-IGN-T : Powered by negative ground CD ignition systems play, and the remaining time in the last three digits. Timer 1= Class “B1”,
with internal tachometer/overspeed sensing.Without RS485 port. Timer 2= Class “B2”, Timer 3= Test, Timer 4= Ignition Ground Delay.
All TTDJ models will accept 32 sensor inputs from normally open and/or Power and Control Inputs/Outputs
normally closed sensors. Each of the first 16 inputs can be configured for The TTDJ power and control inputs and outputs are connected to the
Shutdown or Alarm Before Shutdown*, and can be locked out by one of Power Inputs terminal block on the back of the TTDJ.
the Two Start-Run timers (B1:0-5 min.; B2:0-9:59 min.), or configured as In the TTDJ-IGN and TTDJ-IGN-T the FV+ output is a non-switched out-
Class C. The annunciator provides for both closing of a fuel valve, and put that supplies stored energy from an internal capacitor. -FV and
grounding of an ignition after a time delay. The TTDJ has built-in Elapsed ALARM outputs are non reversible switched outputs (switched OFF for
Time Meter. Run Hours and Tachometer Settings are stored in non- normal operation, switched ON for alarm and shutdown). When a shut-
volatile memory, as well as the last 4 shutdowns and one alarm (alarm down fault is detected, the -FV and ALARM turn ON and after a time
only stored if active at the time of shutdown). The TTDJ liquid crystal delay, the IGN input switches to ground. The alarm output does not
display annunciates any fault from the sensor inputs, displays engine operate for Manual Stop (code 52).
speed and elapsed time. On the TTDJ-DC and TTDJ-DC-T the IGN, FV, and ALARM outputs
Other features for all TTDJ models are: built-in Test Mode to test the sensor are programmed to switch ON for normal operation.
circuits without shutting down, on-board backup battery to retain the fault
display after shutdown (IGN models only), and a history of the last 4 shut- Sensor Inputs and Terminals
downs with their associated Run Hours, also stored in non-volatile memory. Up to 32 dry contact sensor inputs or Murphy device transistor outputs
TTDJ-DC and TTDJ-DC-T models feature an RS485 serial communications can be connected to the back of the TTDJ via a terminal block (32 pair,
port (MODBUS RTU slave) to interface with micro-controllers, PC’S, screw type, each with a jumper). Sensor inputs 1 to 16 are configurable as
PLC’s and controllers. Class“A”, Class “B1”, Class “B2” or Class “C” functions, Shutdown or
Alarm Before Shutdown*. The Class“B” timers allow sensor inputs to be
Module/ Head locked out at start-up. Sensor inputs configured for Alarm Only will cause
The module is the brain of the control system. It contains the microcom- the Alarm Output to turn on when tripped, and the sensor number will be
puter, the Liquid Crystal Display (LCD), the membrane keys for configur- annunciated while the unit continues to run. TTDJ sensor inputs 17-28 are
ing the sensors inputs, the Sensor Inputs Terminal Blocks and the Power dedicated as Class “A” Shutdown only. Sensor input 29 can be configured as a
Inputs and Control Output Terminal Block. The TTDJ-DC module also Class “A”, or Class “ESD” input. Sensor input 32 is dedicated as Class “ESD”.
includes an RS485 serial communications port (MODBUS RTU slave). Sensor inputs 30 & 31 can have special functions or be Class “A”. Any
tripped sensor is detected within 1 second after faulted.
*Alarm Before Shutdown is a function that causes annunciation and the alarm output, but will not cause a shutdown.
TTDJ-99062N page 1 of 8
GENERAL INFORMATION Continued from page 1
Emergency Shutdown at shutdown, as well as the elapsed time reading at which they occurred.
Sensor input number 32 is dedicated to Emergency Shutdown. The For instance, if the unit is shutdown from sensor input 1, the display will
Emergency Shutdown sensor input overrides the Test timer. Additionally, show “01 SD1” to indicate the last shutdown. Shutdown #1 was sensor
sensor input 29 can be configured as a Class “A” or Class “ESD” input. input #1. Press the “Up” key for “Shutdown 2”, “3”, “4”, and for any present
“Alarm”. To view the elapsed time reading at which any of the shutdowns
Remote Reset (optional, Setup 5 = 1, 3, 5 or 7) occurred, press “Push To Read Hours” key while viewing that shutdown.
When the Remote Reset feature is selected, point 30 with a closed contact
resets the TTDJ in the same manner as when using the Reset key. The Class “B” Lockout Timer
closed contacts to operate the Remote Reset feature should be kept closed Allows the system to become fully operational without shutting down by
only momentarily for approximately 1 second to cause a remote reset. start-up related conditions. Class “B1” and Class “B2” Sensor inputs are
locked out until their corresponding timer expires. Class “B1” Timer is selec-
Remote Lockout (optional, Setup 5 = 2, 3, 6 or 7) table from 0:00-5:00 minutes, and Class “B2” Timer from 0:00-9:59 minutes.
The Remote Lockout inhibits the Class B1 and Class B2 Lockout timers.
These Lockouts are ignored when a closed switch is seen at Input 31. An Class “C” Functions
open switch at Input 31 allows the Lockouts to function normally. When the There is a practical limit of sensor inputs defined as Class “C” Shutdown
Remote Lockout is active it resets Class “C”, “B1” and “B2” Lockout timers. and/or Class “C” alarm of 8 points. The Class “C” function operation is that
This is intended to be used with automatic starting systems. With a con- the sensor will be initially faulted on Start-up. If the sensor never clears there
tact closure on terminals 31 with the unit not running, the display will will not be any annunciation and alarm or shutdown. If the sensor clears for a
alternate between either RPM (-T models) and the Class “B1” timer, or full 2 seconds, then it is armed to alarm or shutdown. Pressing the Reset key
the display will flash (non-T models). The TTDJ should be put into will allow a Class “C” alarm function to go back to the Start-up state where it
remote lockout immediately before stopping the engine. The contact clo- can remain faulted without annunciation and alarm. An example of a Class
sure should be opened once the engine is running. At that time the “B1” “C” function is Low Discharge pressure.
and “B2” timers will be allowed to count down.
Ignition Ground Delay
Reset Key This delay is selectable from 0-20 seconds. To select the delay use SETUP.4,
The Reset key resets All faults and initiates the Class “B” timers. see User Set Up Menus and To Enter User Set Up on page 5.
Overspeed (-T models only) Hourmeter
These models feature an internal tachometer with Overspeed Shutdown The TTDJ internal hourmeter keeps track of Run Hours. To display Run
(50). This shutdown bypasses the Ignition Ground Delay. It is not Hours for 5 seconds, press the Push to Read key. Run Hours are stored
locked out by the Test Timer. in non-volatile memory, maintaining hours in the absence of power.
Underspeed Annunciation (-T models only) RS485 Serial Port (TTDJ-DC / TTDJ-DC-T)
TTDJ-IGN-T models display (51) when an underspeed condition occurs. It is The RS485 serial port (MODBUS RTU slave) on the back of the module is
not locked out by the Test Timer. provided for communicating with micro-controllers, PC’s, PLC’s and
Loss of Ignition Annunciation (non -T models) SCADA systems (see RS485 Typical Connections, below). It is recom-
The TTDJ-IGN models will display (51) when ignition input is lost. It is mended that a termination resistor** (customer supplied) be used on the
not locked out by the Test Timer. first and last device connected in a daisy-chain configuration.
The communication parameters are 9600 baud, no parity, 8 bits with 1 stop
Run/Stop Key (Manual Stop) bit (9600,N,8,1), half-duplex. The shield terminal on the TTDJ terminal
The Manual Run/Stop key is used for system shutdown from the panel. block should only be used if the drain wire on the shielded cable is not con-
When pressed, the unit will shutdown the system without turning on the nected to ground anywhere else. Each device must have a unique RTU node
Alarm Output (on -DC models the Alarm Output is turned off on Manual number. A retry delay of 0.3 second may be helpful (set up for 3 retries).
Stop). Manual Stop (Shutdown 52) is not locked out by the Test Timer.
Modbus Integer Holding Registers
Low Backup Battery Voltage (-IGN models) 40001= RPM
The TTDJ-IGN models have an internal backup battery. When the 40002= ETM (elapsed Time Meter 0-65535 Hrs.)
“Lowbatt” display appears (this message will alternate with other dis- 40003= Class B1 (in seconds)
plays) the battery needs to be replaced, see page 3 for details. 40004= Shutdown Numbers (0=OK) (1-32, 50-52 =SD shutdown)
Timer “O” Key 40005= Output Status (Bit 0= IGN, Bit 1= FV, Bit 2= ALR)
This key zeros the current displayed timer: Class “B1”, “B2”, Ignition 40006= Inputs 1-16 (Bit 0 = TB1..., Bit 15= TB16) (True 1= Inactive)
Ground Timer, or Test Timer. If the TTDJ is in the Test mode, it exits Test. 40007= Inputs 17-32 (Bit 0= TB17.., Bit 15= TB32) (True 1= Inactive)
If 40006 and 40007 both contain “FF” there are no active shutdowns.
Test Key
Initiates the Test Timer with 5 minutes. Test mode is indicated by the “3” in RS485 typical connections NOTE: The common or
the first digit of the display. Faulted inputs are displayed as in normal opera- TTDJ #N+1 TTDJ #N Polling Device Power Supply grounds
RTU Node #N+1 RTU Node #N MODBUS Master
tion, but the system is not shutdown and the Alarm Output is not turned on. between connected
Press “Reset” to reset the fault and press the Timer “O” to exit. The follow- A** A A** devices must be con-
ing shutdowns override Test: Emergency Shutdown (32), Overspeed (50), B B
SHD
B
SHD
nected also.
SHD
Manual Stop (52), Underspeed (51), Loss of Ignition (51) and Optional
Additional ESD if chosen as ESD. If Class “C” functions are used, they will TTDJ #2 Other Device TTDJ #1 Polling Device
RTU Node #3 RTU Node #2 RTU Node #1 MODBUS Master
need to be bypassed to test other sensors. When exiting “Test” with Class
“C” functions, press “Reset” and “Timer 0” simultaneously. A** A A A**
B B B B
Shutdown History SHD SHD SHD SHD
The TTDJ models store the last 4 shutdown codes and any alarm present **Terminating resistor is 120 ohms. Install Terminating resistor at the
master and the last slave. Use only Belden 9841 or 3105A cable or
TTDJ-99062N page 2 of 8 cabling with a characteristic impedance of 120 ohms.
SPECIFICATIONS
Power Input (Operating Voltages): Operating Temperature: -40 to 185°F (-40 to 85°C).
TTDJ-DC; TTDJ-DC-T Models: 10- 32VDC, 500 mW max. Storage Temperature: -40 to 185°F (-40 to 85°C).
TTDJ-IGN; TTDJ-IGN-T Models: 90-350 VDC negative ground Sensor Scan Rate: Within 1 second.
CD ignition; approx. 650µA @ 100VDC. B1 Start/Run Timer: Adjustable, 0 - 5 minutes.
Sensor Inputs: 32 N.O. or N.C. passive switches.
B2 Start/Run Timer: Adjustable, 0 - 9:59 minutes.
Inputs 1-16: Configurable as Class “A”, “B1”, “B2”, or “C” Shutdown or
Alarm Before Shutdown*. Pulses per Revolution Range for Tach. Calibration:
Inputs 17-28: Dedicated Class “A” shutdowns. 32-360 (TTDJ-DC-T); 1 - 16 (TTDJ-IGN-T).
Inputs 29: Configurable as Class “A” or Class “ESD”. Overspeed Set point: 0 - 9999 rpm.
Input 30: Selectable Remote Reset or Class “A”. Underspeed Set point: 0 - 5000 rpm.
Input 31: Remote Lockout or Class“A”; inhibits the Class “B1 & Magnetic Pickup: 5 - 120 Vrms, 0-10 kHz.
B2” Lockout Timers. On-Board Backup Power 00005125 (-IGN Versions only):
Input 32: Class “ESD” Overrides Test Timer, typically used for emergency 6 VDC, 1300 mAh, Duracell® DL223A or Sanyo® CR-P2 Lithium battery.
shutdown.
Outputs: 0.5 A @ 350 VDC. Tachometer Accuracy: ±0.5% of the display reading or ±1 RPM
whichever is greater.
Outputs Selection: Ground ignition immediately or trip fuel valve and ground igni
tion after time delay. Hourmeter Range: 0 to 65535 hrs.
Communications: RS485 Serial Port, Modbus RTU slave (TTDJ-DC models). Hourmeter Accuracy: ±15 minutes per year.
*Alarm Before Shutdown is a function that causes annunciation and the alarm output, but will not cause a shutdown.
TTDJ MOUNTING DIMENSIONS (All Models)
WARNING: PERFORM THE MOUNTING OPERATION WITH POWER SOURCE OFF. THE TTDJ SERIES MODULE WAS DESIGNED
TO BE MOUNTED WITHIN A WEATHERPROOF ENCLOSURE. IT IS INTENDED FOR MOUNTING IN A FLAT PANEL. A SQUARE
MOUNTING HOLE OF 5-1/2 IN. (140 MM) AND FOUR MOUNTING SCREW HOLES ARE NEEDED. INSERT THE MODULE FROM THE
FRONT SIDE OF THE PANEL AND SECURE THE FOUR MOUNTING SCREWS AND NUTS THROUGH THE BEZEL.
5-1/4 in.
SENSOR RPM
(133 mm)
6-1/2 in.
(165 mm)
READ
HOURS
RESET RUN
STOP
3-3/8 in.
6-1/2 in. (165 mm) 49/64 in. (86 mm min. mounting clearence)
(19 mm)
5.50 in.
(140 mm) Mounting
6.0 in. Hole
(152 mm)
WARNING: FOR HAZARDOUS APPLICATION REQUIREMENTS, THE TTDJ COMPLETE SYSTEM MUST BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) CLASS I, DIVISION 2, GROUPS C & D (ARTICLE 504)
SPECIFICATIONS AND PER MURPHY DRAWING 50-08-0039. SENSOR INPUT WIRES MUST BE SEPARATED A MINIMUM
OF 2 IN. (51 MM) FROM OTHER WIRES.
FV
FUEL VALVE SD
10-32VDC
+ –
K2 GRD Power Supply
NA Cover
12-24 VDC ALARM RELAY FV
Power supply ALR
MPU
+12/24 VDC GRD
-12/24 VDC Sensor Input Terminals
Magnetic Pickup
5 to 120 Vrms – WARNING –
RS485
A
Explosion hazard.
User wiring installed per NEC for Class I, B DO NOT Connect or
Div. 2, Grps. C & D hazardous locations. SHD disconnect RS485
leads unless
NOTES: the area is known
1. Sensors are normally open or normally closed mechanically
to be non hazardous.
actuated passive switches, or Murphy, certified, non-incendive
or intrinsically safe products.
2. Non-incendive field circuits–VOC= 10.5 VDC, ISC= 1.2 mA.,
CA= 21 uf, LA= 1000 mH.
3. SD, FV and Alarm outputs are rated 0.5 A continuous 350 VDC. Typical Normally Non-incendive field wiring
Typical Normally connections to passive switches.
4. Power supply, power input 10-32 VDC, 16 W max. Closed Sensor Open Sensors
6. K1 and K2 must be hermetically sealed relays, CSA or UL approved (Remove jumper) Route leads separate from other
for use in Class I, Div. 2, Grps C & D hazardous locations. wiring, refer to Notes 1 and 2.
Sensor leads max. length= 500 ft.
7. Fuel Valve in this diagram could be another relay like K1 and K2.
NOTES:
1. Sensors are normally open or normally closed
mechanically actuated passive switches or Murphy
certified, non-incendive or intrinsically safe products.
2. Non-incendive field circuits–VOC= 10.5 VDC, ISC= 1.2 mA., Typical Normally Closed Typical Normally
CA= 21 uf, LA= 1000 mH. Sensor (Remove jumper) Open Sensors
3. IGN, FV and Alarm outputs are rated 0.5 A continuous 350 VDC.
4. Power input 90-350 VDC, CD ignition. Sensor leads max. length= 500 ft.
5. ALR relay must be hermetically sealed relay, Non-incendive field wiring connections to
CSA or UL approved for use in Class I, Div. 2, passive switches. Route leads separate from
Grps C & D hazardous locations. other wiring. Refer to Notes (1,2).
TTDJ-99062N page 4 of 8
TTDJ SENSOR SETUP MAP
TYPE SETUP
STOP
STOP
STOP
RESET
TIMER "0"
STOP STOP STOP STOP STOP STOP STOP STOP
TTDJ-99062N page 5 of 8
STOP
STOP
STOP
STOP
STOP
RESET
TTDJ-99062N page 6 of 8
STOP STOP STOP
MurCal
c
D
RE
GI
STER
E
* Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.
† Selected configurations are third party listed. Consult factory for details.
The OPL-series pressure Swichgage instruments are combination pressure indicating gages with adjustable low and high
limit switches. Limit switches can be wired directly to electric pilot circuits to operate alarms, shutdown or start/stop of
engines and electric motors.
Surface mount or panel mount enclosure is available for most versions. All versions feature a 4-1/2 in. (114 mm) dial for
easy viewing. Adjustable limit switches are accessible from front of the Swichgage instrument. Limit contacts have self-
cleaning motion to enhance electrical continuity.
Other versions available (see page 2):
• Gage-only without contacts (Murphygage instrument)
• Swichgage instrument with built-in latching relay for start-stop operations.
Specifications
Case: Die cast aluminum; weatherproof. Lens: Optically clear polycarbonate.
Contacts: See Electrical page 3, for contact ratings. Pointer: High visibility with a pointer calibration hub.
Dial: 4-1/2 in. (114 mm) white on black, dual scaled psi / Process Connection: Available in 1/4 NPT and 1/2 NPT.
kPa. Other dial configurations available. Consult fac- See Table B, page 5.
tory.
Sensing Element: Select from bronze or 316 stainless
Gage Accuracy: ±2% for the first and last quarters of the steel bourdon tube. See Table B, page 5 for bourdon
scale, the middle half is ±1%. tube/socket combinations.
Geared Movement: 302 and 304 stainless steel.
* † †
OPLC
R
* †
OPLFC
† †
R
OPLBP
* Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.
† Selected configurations are third party listed. Consult factory for details.
Electical Dimensions
Options and Accessories
P4 and P6 Options
The P4 (was PT147) option provides a remote seal mech-
anism to protect the Swichgage instrument sensing ele-
ment from line pressures of highly viscous and mildly
corrosive fluids. Ranges 100 thru 5,000 psi (689 kPa thru
34.5 MPa) [6.9 thru 344.7 bar]. A sealed stainless steel
capillary tube, with stainless steel armor, transmits the
pressure from the diaphragm seal to the Swichgage instru-
ment. Standard capillary length is 5 ft. (1.5 m). Optional
lengths to 50 ft. (15 m) in 5 ft. (1.5 m) increments are avail-
able. Oil well lead lines and pumps with highly viscous liq-
uids are typical applications. If required, customer should
provide a pulsation dampener.
The P6 (was PT167) option is a diaphragm sealed to a 2
NPT housing which attaches directly to the pressure gage
connection. The gage sensing element and the diaphragm
chamber are filled with a silicone fluid so that pressure
against the diaphragm causes the gage to respond. The
diaphragm housing is plated machined steel. Typical appli-
cation is for oil well lead lines. Ranges 100 thru 1,000 psi
(689 kPa thru 6.8 MPa) [6.89 thru 68.9 bar]. The P4 and
P6 can be ordered as optional features to the Swichgage
or indicating-only Murphygage instrument. See How to
Order on pages 5 and 6.
AP-94030B page 1 of 4
Dimensions
A20 Series Models A25 Series Models
2-1/4 in. 2-9/16 in. 2-29/32 in. 1-51/64 in.
(57 mm) (65 mm) (74 mm) (46 mm)
RP
HY
S WI CHG
AG
E
1/8-27
U P.S.I. ® S WI CHG
M
40 60
NPTM RP
HY AG
1/8-27
20
80
10
2-1/32 in. M
U
PSI E
®
0 0 (52 mm) NPTM 2-5/8 in.
300 60 Mounting 60
0 0 40 80 (67 mm)
kPa Clamp 20 10
PRESSURE 0 Mounting
0
300 600 Clamp
0
kPa
PRESSURE
Ranges Available Maximum Standard Settings High Settings* A20PABS and A25PABS Settings
Low Alarm†
psi (kPa) [bar] Pressure psi (kPa) [bar] psi (kPa) [bar] psi (kPa) [bar] psi (kPa) [bar]
0-15 (103) [1.0] 30 psi (207) 3 (21) [0.2] 12 (83) [0.8] 3 (21) [0.2] 6 (41) [0.3]
0-30 (207) [2.0] 60 psi (413) 7 (48) [0.4] 24 (165) [1.6] 7 (48) [0.4] 10 (69) [0.6]
0-50 (345) [3.5] 100 psi (690) 10 (69) [0.8] 40 (276) [2.8] 10 (69) [0.8] 13 (90) [1.0]
0-75 (517) [5.0] 150 psi (1.0MPa) 15 (103) [1.0] 60 (414) [4.0] 15 (103) [1.0] 18 (124) [1.5]
0-100 (690) [7.0] 200 psi (1.4MPa) 20 (138) [1.5] 80 (552) [5.5] 20 (138) [1.0] 23 (159) [1.5]
0-150 (1.0 MPa) [10] 300 psi (2.1 MPa) 30 (207) [2.0] 120 (827) [8.0] 30 (207) [1.5] 33 (228) [2.0]
0-200 (1.4 MPa) [14] 400 psi (2.8 MPa) 50 (345) [3.0] 150 (1 MPa) [10] 50 (345) [3.0] 53 (365) [4.0]
0-300 (2.1 MPa) [20] 500 psi (3.4 MPa) 75 (517) [5.0] 225 (1.6MPa) [15] 75 (517) [5.0] 78 (538) [5.0]
0-400 (2.8 MPa) [28] 500 psi (3.4 MPa) 150 (1.0 MPa) [7.0] 300 (2.1MPa) [20] 75 (517) [5.0] 150 (1MPa) [10]
**Low settings for Hi/Lo option same as standard settings. Hi/Lo option available for A20P and A25P models only.
†SPDT Snap-switch is the alarm switch.
Features
A. Process Connection and Port: Machined from brass bar stock. Together with Typical For All Series (A25P Series Shown)
the diaphragm forms the diaphragm chamber.
B. Diaphragm (not shown): Beryllium copper die formed and heat treated to very
close physical and metallurgical specifications.
F
C. Pulsation Dampener: Designed to minimize undesirable pointer chatter. It is PH
Y SWICHGA
removable for cleaning. G M
UR
PSI
GE
D
®
J. Limit Contact Adjustment: by 1/16 in. hex type wrench thru 100% of the
J A H P L
scale. Easy adjustment knob available.
K. Electrical Connections: Number 4 screw terminals for A20 Series; and num- C
ber 6 screw terminals for A25 Series models. E K
AP-94030B page 2 of 4
Magnetic Switch
INDUCTIVE AND HIGH CURRENT LOADS REQUIRE THE USE OF A Tattletale® Magnetic Switches show the cause of shutdown for applications that
MAGNETIC SWITCH. The Swichgage contacts are for light-duty electrical include: capacitor discharge or magneto ignitions, battery systems and electric
switching to operate alarms or control devices. Murphy manufactures the motor driven equipment. Typical wiring diagrams are shown below.
Magnetic Switch for protection of the pilot-duty Swichgage limit contacts.
A20P Pressure 117 Magnetic Switch A20P Pressure A20T Temperature 518PH
® ®
Swichgage
® Swichgage Swichgage
R
LOW LOW HIGH G NC SW1 SW2 B
C S B
®
N.O. Swichgage
N. C. C instruments C N. O.
N. C. C
ABS HIGH
N. C. C N. O.
Shutdown Device
or Ignition Circuit
Opens circuit to
shutdown engine.
_ +
Battery
N. C. C N. O. N. C. C N. O. N. C. C N. O. N. C. C N. O.
L P H L P H L P H L P H L P H
AP-94030B page 3 of 4
How to Order
To order, use the diagram below. List options in ascending alphabetical order (A-Z). Example: A20P-K-100.
Base Model
A20P A25P
Range††
A20PE A25PE
A20PABS A25PABS Dual scale (psi/kPa) Single scale (bar)
A20PG A25PG psi kPa/MPa 1B = 0-1 bar
15 = 0-15 0-103 2B = 0-2 bar
30 = 0-30 0-207 3.5B = 0-3.5 bar
50 = 0-50 0-345 5B = 0-5 bar
Options† 75 = 0-75 0-517 7B = 0-7 bar
B1 = Black bezel 100 = 0-100 0-689 10B = 0-10 bar
EX = Explosion-proof (CSA Listed for 150 = 0-150 0-1.03 14B = 0-14 bar
Class I, Div. 1, Groups C & D)* 200 = 0-200 0-1.38 20B = 0-20 bar
EL = Explosion-proof less case 300 = 0-300 0-2.07 28B = 0-28 bar
HL = High and low contacts 400 = 0-400 0-2.76
K = Knob adjusting face contact ††Consult factory for availability of dials other than psi/kPa. Select scale
OS = Oil sealed (Silicone Oil) so your normal operating pressure is in the middle half of the scale.
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product.
A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. MURPHY, the Murphy logo, and Swichgage® are registered and/or common
www.fwmurphy.com law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright
918.317.4100 Email: sales@fwmurphy.com protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
AP-94030B page 4 of 4
SPL-92106N
Installation for 4-1/2 in. (114 mm) dial Revised 04-04
Section 10
(00-02-0167)
*
WARNING ®
SPL-92106N page 1 of 4
CASE MOUNTING
panel
120 Optional
1/2 in.
Mounting Hole 1/4 in. (6 mm) dia. (13 mm)
4-3/4 in. holes (3 places.) on conduit
(121 mm) 5-13/64 in. (132 mm)
diameter B.C.,120 apart,
clocking as shown
9/32 in.
(7 mm) dia.
3 holes
Options -OS, -ES (flush mount case)
DETAIL
5-7/16 in. 2-57/64 in.
shock mount (138 mm) (73 mm)
gage panel
6-3/4 in.
(171 mm)
Optional
Back
Connection
2-23/32 in.
(69 mm)
SPL-92106N page 2 of 4
SENSING BULB-THERMOWELL INSTALLATION
Precautions Installing Thermowell
SWICHGAGE®
Cutting or sharp bending the capillary will cause permanent damage Thermowell is recommended for high
to the SWICHGAGE® and will void the warranty. Excess capillary 100 500 pressure applications or corrosive
should be carefully coiled and secured away from damage. Do not 0 800 environments. It also allows tempera-
route capillary along exhaust manifold. Avoid routing capillary at a ture sensor to be changed or adjusted
level higher than gage mounting. without opening connection to process.
1. First screw the thermowell into the
Installing Sensing Bulb
transmitting process (pipe line).
1. Install the 1/2 NPT adapter into the tube or
application.
capillary 2. Pass the sensing bulb through the
compression nut and ferrule.
2. Slip compression nut and ferrule Adapter nut
onto bulb. 3. Fully insert the sensing bulb into the
3. Insert the sensing bulb directly thermowell housing and secure it
through the adapter and fully Wall
with the compression nut.
Sensing
immerse it into the process without bulb
insertion
NOTE: The use of temperature trans-
interference. Be sure to leave enough of mitter grease or silicon grease on the
the bulb to allow the compression nut and 6 in.
tip of the sensing bulb is recommended
ferrule to be tightened. active (152 mm) to facilitate heat transfer to sensing
section of
4. Keep the bulbs active section in the middle of the process flow. sensing bulb bulb junction.
5. Tighten the compression nut and ferrule. This will keep the
bulb in place and obtain a full seal.
SPL-92106N page 3 of 4
TYPICAL ELECTRICAL DIAGRAMS
WARNING: Perform the wiring operation with the power source “OFF”. Make sure the voltage and current
requirements are within the SWICHGAGE® ratings. Before wiring determine voltage and polarity for the
application. Use the appropriate wire size. All connections should be made using a spade (forked) or ring
terminals. For pigtail connections use wire nuts. Conduit is recommended to protect wires from damage.
Start Up
Lock Out
Toggle LOW SWITCH HIGH SWITCH
Switch
N.C.–Orange N.C.–Black
3 6
Red White Black Red White Black N.O.–Blue N.O.–Brown
2 5
Common–Red Common–Yellow
SPLBP 1 4
Contact Ratings: SPDT dry relay contacts; 10 A, 125 VAC.
NOTE: Diagrams below show the pointer in the at rest (shelf) position. 45TEBP
Contact Ratings: SPDT dry relay contacts; 10 A, 125 VAC.
Yellow
Blue
3 Reset NOTE: Diagrams below show the pointer in the at rest (shelf) position.
Common 4 1
7
4
Yellow
Blue
3 Reset
= 18 GA.
3 Common 4 1
9 7
= 16 GA. Brown
5 Set 4
6
= 24 GA.
3
8 = 18 GA.
White 9 Brown
Neutral 1
= 16 GA.
5 Set
6
– A B
8
White Orange
Red Neutral 1 6
Orange
12 VDC
– A B
24 VDC
Low
Brown
120 VAC/24 VAC
(Reset)
Blue
High 12 VDC
Black 6
+ Line 2 (Set) 24 VDC
Low
(Reset)
Transformer Relay Assemblies + Line 2
Red High
For higher voltages the Murphy TR Assemblies can be used in Yellow (Set)
conjunction with any SWICHGAGE®.
CONTROL SYSTEMS & SERVICES DIVISION FRANK W. MURPHY, LTD. MACQUARRIE CORPORATION
P.O. Box 1819; Rosenberg, Texas 77471; USA Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. 1620 Hume Highway
+1 281 633 4500 fax +1 281 633 4588 +44 1722 410055 fax +44 1722 410088 Campbellfield, Vic 3061; Australia
e-mail sales@fwmurphy.com e-mail sales@fwmurphy.co.uk +61 3 9358 5555 fax +61 3 9358 5558
FW Murphy
MURPHY DE MEXICO, S.A. DE C.V. www.fwmurphy.co.uk e-mail murphy@macquarrie.com.au
P.O. Box 470248
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje MURPHY SWITCH OF CALIFORNIA
Tulsa, Oklahoma 74147 USA
San Luis Potosí, S.L.P.; México 78384 41343 12th Street West
+1 918 317 4100 +52 444 8206264 fax +52 444 8206336 Palmdale, California 93551-1442; USA
D
RE
Villahermosa Office +52 993 3162117 +1 661 272 4700 fax +1 661 947 7570
STER
SPL-92106N page 4 of 4
A20 and A25 Series AT-95026B
Revised 08-05
**
2 and 2-1/2 in. (51 and 64 mm) Dial
■ Corrosion Resistant Polycarbonate Case
■ Indicating Gage and Limit Switch
■ Switch Can Activate Alarms and/or Shut
Down Equipment
■ Critical/High Temperature Limit Switch
A20T Series
Is Visible and Adjustable (Most Models)
shown ■ Contact(s) Isolated From Ground
S WI CHG
HY AG
RP
U °F E
® S WI CHG
M
HY AG
RP E
U
160 210 230 M °F ®
130 25
0 Mounting
60
80 100 1 160 210 230
130
20 Clamp
°C 25
TEMPERATURE 0 Mounting
80 100 1 Clamp
60 20
°C
TEMPERATURE
Capillary†
2-1/16 in. (53 mm) 1-27/64 in. 4 ft. (1.2 m)
Mounting hole dia. (36 mm) long Capillary†
Contact
4 ft. (1.2 m)
Adjustment 1-11/32 in. long
2-11/16 in. (68 mm) (34 mm)
1/16 in. hex Mounting hole dia.
1-1/2 in.
1/2 NPT (38 mm) 5/8-18 U.N.F.
Contact
Adapter Nut† Sensing Bulb† Union Nut
Adjustment
1-1/2 in.
1/16 in. hex
1/2 NPT (38 mm) 5/8-18 U.N.F.
†Standard combinations. See Murphy bulletin T-8428B for optional sensing bulb, engine adaptors and capillary combinations. Adapter Nut† Sensing Bulb† Union Nut
130 to 220°F (54 to 104°C) ± 6°F (± 3°C) ± 3°F (± 1.6°C) ± 4°F (± 2°C)
130 to 250°F (54 to 121°C) ± 9°F (± 5°C) ± 5°F (± 2.4°C) ± 4°F (± 2°C)
140 to 300°F (60 to 149°C) ± 10°F (± 5.2°C) ± 6°F (± 3°C) ± 5°F (± 2.4°C)
160 to 320°F (71 to 160°C) ± 10°F (± 5.2°C) ± 5°F (± 2.4°C) ± 5°F (± 2.4°C)
180 to 350°F (82 to 177°C) ± 12°F (± 6°C) ± 5°F (± 2.4°C) ± 5°F (± 2.4°C)
300 to 440°F (149 to 227°C) ± 9°F (± 5°C) ± 5°F (± 2.4°C) ± 4°F (± 2°C)
R
LOW HIGH G NC SW1 SW2 B
HIGH C S B ®
N.O. SWICHGAGE
N. C. C instruments C N. O.
C N. O.
ABS HIGH
N. C. C N. O.
Shutdown Device
or Ignition Circuit
Opens circuit to
shutdown engine.
_ +
Battery
N. C. C N. O. N. C. C N. O. N. C. C N. O. N. C. C N. O.
L P H L P H L P H L P H L P H
To order, use the diagram below. List options in ascending alphabetical order (A-Z). Example: A20T-B1-250-4.
Base Model
Adapter Nuts†††
A20T A20TG 1/8 = 1/8-27 NPT Metric
A20TL A25T 1/4 = 1/4-18 NPT M10 = 10 mm x 1.5
A20TO A25TL 3/8 = 3/8-18 NPT M12 = 12 mm x 1.5
A20TE A25TE 3/8B = 3/8-19 BSPT M14 = 14 mm x 1.5
A20TABS A25TABS 3/8K = 3/8 NPSF M16 = 16 mm x 1.5
††††
– = 1/2-14 NPT M18 = 18 mm x 1.5
A20TB A25TH 1/2B = 1/2-BSPT M20 = 20 mm x 1.5
A20TH A25TG 1/2K = 1/2 NPSF M22 = 22 mm x 1.5
5/8 = 5/8-18 UNF M24 = 24 mm x 1.5
3/4 = 3/4-14 NPT
3/4U = 3/4-16 UNF †††Specific adapter nut must
Options† 7/8 = 7/8-9 UNC match the sensing bulb.
B1 = Black bezel ††††Standard.
Warranty
A limited warranty on materials and workmanship is given with
this FW Murphy product. A copy of the warranty may be viewed
or printed by going to www.fwmurphy.com/support/warranty.htm
CONTROL SYSTEMS & SERVICES DIVISION FRANK W. MURPHY, LTD.
P.O. Box 1819; Rosenberg, Texas 77471; USA Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+1 281 633 4500 fax +1 281 633 4588 +44 1722 410055 fax +44 1722 410088
e-mail sales@fwmurphy.com e-mail sales@fwmurphy.co.uk
FW Murphy www.fwmurphy.co.uk
INDUSTRIAL PANEL DIVISION
P.O. Box 470248 MURPHY DE MEXICO, S.A. DE C.V.
P.O. Box 470248
Tulsa, Oklahoma 74147 USA Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
Tulsa, Oklahoma 74147 USA
+1 918 317 4100 fax +1 918 317 4266 San Luis Potosí, S.L.P.; México 78384
+1 918 317 4100 fax +1 918 317 4266
e-mail sales@fwmurphy.com +52 444 8206264 fax +52 444 8206336
e-mail sales@fwmurphy.com
Villahermosa Office +52 993 3162117
www.fwmurphy.com e-mail ventas@murphymex.com.mx Printed in U.S.A.
www.murphymex.com.mx
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
Bulletin AT-95026B page 4 of 4
DVU-01069B
DVU Series
■ For Separators/Scrubbers to 2000 psi
(13.8 MPa) [138 bar] Working Pressure
■ Hex Union Allows Plug and Seat
Replacement Without Piping Removal
■ Operates on 30–70 psi (207–483 kPa)
[2.07–4.83 bar] Control Pressure
■ Compatible With Murphy Level Controls
150
150 NOTE: Dimensions are in inches and (millimeters)
Pressure (psid)
100
50
50 Control Pressure vs. Working Pressure
Minimum Actuation Pressure
0 70
DVU2115 DVU2120
Control Pressure (PSIG)
5 10 15 20 25 30 35 40 45 60
Flow (gpm)
50
40 DVU150/175
DVU2105
30
20
10
DVU-01069B page 1 of 2
Scrubber Level The Murphy Gas Compressor Scrubber Level System (SLS)
Systems (SLS)
(Includes L1200, L1200NDVOR and DVU valve) The system provides for liquid
control in gas scrubber appli- High Level Shutdown Switch
SLS02BC: Includes DVU2120 valve
cations, by dumping liquids to Stainless steel float actuated level switches to alarm
SLS02BB: Includes DVU2115 valve drain and protecting compres- and/or shutdown the equipment.
SLS02BA: Includes DVU2105 valve sors with a high liquid level L1200: 2” NPT pipe connection; Rated 2000 psi
SLS02C: Includes DVU175 valve switch. Wetted metal parts are (13.7MPa) [137bar]; Class I, Division 1. SPDT
snap-switch standard. DPDT Optional.
SLS02A: Includes DVU150 valve made to survive constant use
All Stainless Steel available.
-LR: Less Regulator option in corrosive environments.
See Bulletin: SLS-04005B for
Replacement Parts more details.
Typical Seal Kit includes: Nut, Washer (1 to 3),
“O” Ring, Plug and Seal, Seat, Crush Washer. Filter/Regulator &
Typical Diaphragm Repair Kit includes: MURPHYGAGE® Control
Panel
Diaphragm, Diaphragm Washer (upper), Diaphragm
Nut, Diaphragm Plate (1 or 2 pcs.), Packing, “Instrument
“O” Ring, Stem, Seal Washer for Maintenance Bolt. Quality Air/Gas
Supply”
Part No. Description
DVU2120
55-00-0237 Seal Kit (includes plug)
55-00-0236 Diaphragm Kit Pneumatic Level Control
Float actuated level snap-acting
DVU2115 switch controls pneumatic pressure
55-00-0241 Seal Kit (includes plug) to open and close dump valve. Pneumatic Dump
55-00-0240 Diaphragm Kit L1200NDVOR: Dump Valve Operator, Valves See DVU-01069B
pressure regulator, and pressure indi- for more details.
DVU2105 Two piece union design with manual valve operator
cating MURPHYGAGE. ®
55-00-0245 Seal Kit (includes plug) allows soft plug and hard seat to be replaced with-
55-00-0244 Diaphragm Kit out disassembling outlet piping or scrubber pipe
DVU175 connection. Diaphragm actuated valves operate on
55-00-0230 Seal Kit (includes plug) 30-70 psi (207-483 kPa; 2-5 bar).
55-00-0231 Diaphragm Kit
DVU150
55-00-0230 Seal Kit (includes plug) How to Order Specify model number: Working
55-00-0231 Diaphragm Kit Model Inlet Outlet Trim Size Max. Press.
DVU2120 2 NPT 1 NPT 0.436 in. (11 mm) 2000 psi.
Shipping Weights
DVU2115 2 NPT 1 NPT 0.576 in. (15 mm) 1500 psi.
DVU150 and DVU175: 9 lbs. (4 kg.).
DVU2105 2 NPT 1 NPT 0.859 in. (22 mm) 500 psi.
DVU150SS and DVU175SS: 9 lbs. (4 kg.)
DVU175 1 NPT 3/4 NPT 0.359 in. (9 mm) 1800 psi.
DVU2105, DVU2115, DVU2120: 14 lbs. (6.4 kg.) DVU175SS 1 NPT 3/4 NPT 0.359 in. (9 mm) 1800 psi.
Shipping Dimensions DVU150 1 NPT 1/2 NPT 0.359 in. (9 mm) 1800 psi.
8 x 8 x 12 in. (203 x 203 x 305 mm.). DVU150SS 1 NPT 1/2 NPT 0.359 in. (9 mm) 1800 psi.
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product.
A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
CONTROL SYSTEMS & SERVICES DIVISION FRANK W. MURPHY, LTD. MACQUARRIE CORPORATION
P.O. Box 1819; Rosenberg, Texas 77471; USA Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K. 1620 Hume Highway
+1 281 633 4500 fax +1 281 633 4588 +44 1722 410055 fax +44 1722 410088 Campbellfield, Vic 3061; Australia
e-mail sales@fwmurphy.com e-mail sales@fwmurphy.co.uk +61 3 9358 5555 fax +61 3 9358 5558
FW Murphy
MURPHY DE MEXICO, S.A. DE C.V. www.fwmurphy.co.uk e-mail murphy@macquarrie.com.au
P.O. Box 470248
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje MURPHY SWITCH OF CALIFORNIA
Tulsa, Oklahoma 74147 USA
San Luis Potosí, S.L.P.; México 78384 41343 12th Street West
+1 918 317 4100 +52 444 8206264 fax +52 444 8206336 Palmdale, California 93551-1442; USA
D
RE
Villahermosa Office +52 993 3162117 +1 661 272 4700 fax +1 661 947 7570
STER
Installation Instructions
Please read the following information before installing.
A visual inspection of this product for damage during shipping is recommended before mounting.
WARNING
R R
Environmental Effect:
Total Load Resistance (RL)*
Area
Shock: 1000g 1ms Half sine Pulse in each of 3 mutually perpendicular axis Over
will not affect performance. 19V, 500 Ω
Voltage
Area
Vibration: Effect on output response is less than 0.05% FS/g at 30g Peak
500
10Hz to 2kHz, limited by 0.05 in double amplitude. (MIL STD 810C
Proc. 514.2-2 curve L). Operating
250 Area
PXT Power Requirements: Typically 24 VDC is required, using the Loop
Resistance Graph, 9-30 VDC. 0
10 14V @ 20 30 40 50
PXT Series Transmitter Output: 4–20 mA, 2-wire. 250 ohm
Insulation: Greater than 10 Mohms @ 500 VDC. Power Supply Voltage (VDC)
*NOTE: Cable resistance effect included in RL.
Installation 00-02-0475 page 1 of 2
PXT Series Dimensions
Low Pressure Units WARNING: READ BEFORE INSTALLATION
.86 in. 2 in. 2.30 in.
(22 mm) Fluid hammer and surges can destroy any pressure transmitter/transducer
(51 mm) (58 mm)
60 in. (1524 mm) and must always be avoided. A pressure snubber should be installed to
long cable-std.
eliminate the damaging hammer effects.
1.18 in. Dia.
(30 mm) Fluid hammer occurs when a liquid flow is suddenly stopped, as with
quick closing solenoid valves. Surges occur when flow is suddenly begun,
316 Stainless 1/2 NPTM as when a pump is turned on at full power or a valve is quickly opened.
1/4 NPTF 7/8 Hex Liquid surges are particularly damaging to pressure transmitter/trans-
Steel Housing .866 A/F
ducer if the pipe is originally empty. To avoid damaging surges, fluid
High Pressure Units line should remain full (if possible), pumps should be brought up to
power slowly and valves operated slowly. To avoid damage from both
.86 in. fluid hammer and surges, a surge chamber should be installed, and a
(22 mm) 2.08 in. 2.30 in.
(53 mm) (58 mm) pressure snubber, such as Murphy PD-8100 Series (adjustable) or
60 in. (1524 mm)
long cable-std. PM6203 Series (fixed) call Murphy for details, should be installed on
1.18 in. Dia. every transmitter/transducer.
(30 mm)
Symptoms of fluid hammer and surges damaging effects:
1/2 NPTM a. Pressure transmitter exhibits an output at zero pressure (large zero offset).
1/4 NPTF 7/8 Hex 316 Stainless
Steel Housing .866 A/F b. Pressure transmitter output remains constant regardless of pressure.
c. In severe cases, there will be no output.
PXT Series Electrical Connections
Noise
CAUTION: HOOKUP CABLE IS NON-SERVICEABLE. For minimum noise susceptibility avoid running the transmitters/transduc-
DO NOT UNSCREW CAP NUT. ers cable in a conduit that contains high current AC power cables or igni-
tion loom on engine. Where possible avoid running the cable near induc-
Red Cable = +Power tive equipment. Shielded cable is always recommended. Earth the shield
Blue Cable = –Power at one end only.
Orange; Yellow; White; Shield; = Not Connected
Mounting
PXT Installation Diagram CAUTION: THESE ARE PRECISION INSTRUMENTS.
DO NOT INSTALL IN ANY MANNER THAT CAN CAUSE
HAZARDOUS AREA SAFE AREA
SIDE STRESS OR IS SUBJECT TO EXCESSIVE VIBRATION.
INSTALLATION INSTRUCTIONS FOR CLASS I DIV 2
POWER BARRIER
UNITS MEET CLASS I DIV 2 WHEN INSTALLED IN ACCORDANCE Hold when attaching
WITH CLASS I DIV 2 METHODS. EITHER BY USING THE CONDUIT Voc 28 V to pressure source
AND GROUND CONNECTION PROVIDED OR BY INSTALLING IN A Isc 93 mA
SUITABLE ENCLOSURE ACCEPTABLE TO THE LOCAL AUTHORITY BUSBAR
HAVING JURISDICTION. Ca 0.12 µF
INSTALLATION INSTRUCTIONS FOR CLASS I DIV 1
La 3 mH
Class I, Groups A, B, C, D
Class II, Groups E, F, G V SUPPLY
CONTROL EQUIPMENT
MUST NOT BE CONNECTED TO
PXT SERIES POWER EQUIPMENT WHICH USES OR Do NOT twist body
RETURN GENERATES MORE THAN
250 VRMS WITH RESPECT TO
EARTH GROUND The transmitter/transducer requires no special mounting hardware and
can be mounted in any plane with negligible position error.
TRANSMITTER ENTITY PARAMETERS
TERMINALS VMAX IMAX CI LI
Although the unit can withstand substantial vibration without damage
POS - NEG 28 V 93 mA 0.11 µF O.22 mH or significant output effects, it is always good practice to mount the
BARRIER NOTES
Vmax >= Voc 1 OUTPUT CURRENT MUST BE LIMITED BY A transmitter where there is minimum vibration.
RESISTOR SUCH THAT THE OUTPUT VOLTAGE
I max >= Isc
Ci + C cable =< Ca
Vs CURRENT PLOT IS A STRAIGHT LINE Apply Teflon tape/sealant to the pressure fittings threads before
BETWEEN Voc AND Isc
Li + L cable =< La 2 BARRIER MUST BE INSTALLED AS installing. When tightening, apply a wrench to the hex wrench flats
USE THE FOLLOWING PARAMETERS IF CABLE INSTRUCTED BY THE MANUFACTURER
PARAMETERS ARE UNKNOWN.
EARTH GND located just above the pressure fitting. DO NOT tighten by using a
3 SELECTED BARRIER INTRINSICALLY SAFE
CABLE CAPACITANCE: 60 pF/ft CIRCUITS SHALL BE APPROVED FOR pipe wrench on the housing.
µF) CLASS I, II, III DIV 1 & 2, GROUPS A-G
CABLE INDUCTANCE: 0.2 µH/ft 4 TERMINATE BARRIER EARTH GROUND TO THE
(EX.L Cable=1000ft x 0.2 µH/ft=0.2mH) GROUND BUS OF THE POWER DISTRIBUTION
PANEL. RESISTANCE TO GROUND MUST NOT Warranty
ALL INTRINSICALLY SAFE WIRING SHALL BE KEPT BE GREATER THAN 1 OHM
SEPARATE FROM NON-INTRINSICALLY SAFE WIRING. A limited warranty on materials and workmanship is given with this
REFER TO ARTICLE 504 OF THE NATIONAL FW Murphy product. A copy of the warranty may be viewed or
ELECTRICAL CODE OR THE CANADIAN ELECTRICAL CODE.
printed by going to www.fwmurphy.com/support/warranty.htm
CONTROL SYSTEMS & SERVICES DIVISION FRANK W. MURPHY, LTD.
P.O. Box 1819; Rosenberg, Texas 77471; USA Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+1 281 633 4500 fax +1 281 633 4588 +44 1722 410055 fax +44 1722 410088
e-mail sales@fwmurphy.com e-mail sales@fwmurphy.co.uk
FW Murphy www.fwmurphy.co.uk
INDUSTRIAL PANEL DIVISION
P.O. Box 470248 MURPHY DE MEXICO, S.A. DE C.V.
P.O. Box 470248
Tulsa, Oklahoma 74147 USA Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
Tulsa, Oklahoma 74147 USA
+1 918 317 4100 fax +1 918 317 4266 +1 918 317 4100 fax +1 918 317 4266 San Luis Potosí, S.L.P.; México 78384
e-mail sales@fwmurphy.com +52 444 8206264 fax +52 444 8206336
e-mail sales@fwmurphy.com
Villahermosa Office +52 993 3162117
www.fwmurphy.com e-mail ventas@murphymex.com.mx Printed in U.S.A.
www.murphymex.com.mx
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
Installation 00-02-0475 page 2 of 2
0610107
05-19-06
Section 10
Features
• ¼” diameter 316 stainless steel tubing • Can be bent anywhere along its length to a
sheath 90° angle
• K type, 6” and 10” long ¼” probes • Tip sensitive to minimize temperature
influence from surrounding environment
Due to the increase in controller and telemetry applications, this thermocouple product line has been added to the
line up of Murphy temperature monitoring end devices. They are designed to fit as many applications as possible
with the fewest possible parts and the fewest possible installation caused faults.
Most of the thermocouple failures occur in how the
thermocouples extension wire is installed and connected.
This new line incorporatesType K, 20 AWG stranded
extension wire encased in a rugged cable to meet demanding
environments The extension wire lengths are available in 5’,
15, 30’, 50’, and 100’ lengths. This will enable a run from the
point of measurement to the nearest conduit entry or to be
installed in a cable tray. The industry standard yellow Teflon
allows easy identification of K type thermocouple wires so
they can be separated from high voltage wires following good
installation practices.
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
MURPHY and the Murphy logo, are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and
illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2005 Murphy Industries, Inc.
LM-92149B
Level Maintainer
Revised 10-03
Catalog Section 15
(00-02-0061)
LM301-EX
LM300 Series
Maintains proper lube level
Shutdown on low level, or high and low level
Low level alarm before shutdown
Manual float switch test
High visibility “Frog Eye” lens
Optional pipe or universal mounting brackets
Optional inlet orifices for low to high pressure
** applications
Explosion-proof models available
Patent 5493086
Description Max. Differential: 2 in. (51 mm) between running Optional Hose Kit: 15000355
The LM300 Series Level Maintainer automatical- and stationary oil level. Quantity Description
ly adds oil to the crankcase as needed to keep the Max. Case Pressure (MCP): 1 1/2 in. (13 mm) I.D. x
lube level normal. Most models have built-in 15 psi (103 kPa) [1.03 bar]. 3 ft. (914 mm) long hose
switches that will alarm and/or shutdown the Orifice Seal†: Buna-N Thumb-Valve™ 1 1 in. (25 mm) I.D. x
equipment if the makeup supply is depleted and Switch Contact: Silver, SPDT snap acting, rated 3 ft. (914 mm) long hose
engine oil level falls or if overfill conditions exist. at 10 A @ 125, 250 VAC; 10 A @ 30 VDC. 2 1/2 in. (13 mm) worm gear clamp
LM300 series explosion-proof models are CSA (1 only for low level; 2 only for high and low; or 2
certified†† for Class I, Division 1 Hazardous areas. 2 1 in. (25 mm) worm gear clamp
only for low level with alarm before shutdown)
2 1/2 NPT x 1/2 in. (13 mm) barbed fitting
Applications Flow Rate Test: Using SAE 30 @ 32°F (0°C). 2 3/4 NPT x 1 in. (25 mm) barbed fitting
• Engines • Pumps
• Compressors • Coolers Orifice
Diameter
Pressure Flow Rates
Base Models *
Specifications 1/4 in.* 4 ft. oil – 15 ft. oil 4.7 GPH - 31.0 GPH LM300: Level Maintainer only (no switches).
Case/Cover: Die cast aluminum. (6 mm) (1.2 m oil – 4.6 m oil) (17.8 LPH - 117.3 LPH)
LM301: Low switch contacts for low level shut-
Switch Housing: Aluminum. 10 psig – 30 psig down or alarm. Four wires, SPDT.
1/8 in. (68.9 kPa – 207 kPa) 16.9 GPH - 32.1 GPH
Approval Rating: LM301 thru LM305 : CSA (3 mm) [.69 – 2.07 bar] (63.7 LPH - 121.5 LPH) LM302: Two switches for low and high level
certified†† for non hazardous locations. shutdown or alarm. Four wires, DPST, wired
Enclosure Type 4 certified. *Standard N.O. in normal operating ranges.
LM301-EX thru LM305-EX: CSA certified†† NOTE: Friction losses due to piping NOT considered.
LM303: Two switches for low and high level
for Class I, Groups C and D; Class II, Groups shutdown or alarm. Four wires, DPST, wired
F and G hazardous locations. Enclosure Type 4 Outlet Connection: 3/4-14 NPT left side, right
side, and bottom. N.C. in normal operating ranges.
certified.
Crankcase Balance Vent Fitting: 1/2-14 NPT. LM304: Two switches. Alarm before shutdown
Float: Rigid polyurethane foam. Polyurethane on low level and shutdown on low-low level.
coated. Mounting: Accepts Murphy pipe mounting
Four wires, DPST, wired N.O. in normal oper-
Max. Ambient Temperature: 250°F (121°C) bracket or universal mounting bracket.
ating ranges.
Oil Inlet Connection: Top entry 1/2-14 NPT with Lens: Clear “Frog Eye” non-staining, high impact,
LM305: Two switches. Alarm before shutdown
built-in filter screen (removable for cleaning). high temperature nylon; UV and heat stabilized.
on low level and shutdown on low-low level.
Inlet Orifices: 1/4 in. (6 mm) standard. Dial: High visibility white background with Four wires, DPST, wired N.C. in normal oper-
1/8 in. (3 mm) available. green and white “index” lines for normal ating ranges.
level indication.
Wire (switch models): 18 AWG x 13 in. * Specify “EX” for explosion-proof enclosure. All models except
(1.0 mm2 x 330 mm). Test Knob: Rotate to test switch operation. LM300 are available in an explosion-proof enclosure.
Turn clockwise for low level test and turn ** Products covered by this bulletin comply with EMC Council
Max. Inlet Pressure (MIP): directive 89/336/EEC regarding electromagnetic compatibility
counterclockwise for high level test.
30 psi (207 kPa) [2.07 bar]. except as noted.
††CSA certified with switch contacts rated at 10 A at 250 V AC (standard).
with 1/8 in. (3 mm) orifice.
15 ft oil (4.6 m oil)
with 1/4 in. (6 mm) orifice.
Dimensions
The dimensions below are for the optional “EX” model enclosure. The standard model enclosure dimensions are the same except
the height and width which are: 7 in. (178 mm) H, 7-7/8 in. (200 mm) W.
Oil Inlet Connection 6 in.
1/2-14 NPT with (152 mm) 7-3/16 in.
removable screen (183 mm)
Electrical
Crankcase Vent Conduit Snap Switch
Connection 1/2-14 Case Assembly
1/2-14 NPT NPT
5-15/16 in.
Test (151 mm)
Knob
5-3/16 in.
Oil Outlet Connection (132 mm)
3 places, 3/4-14 NPT
LM303
m
i
4 in
91 0
GI
ST ER
E
Printed in U.S.A.
LM-92149B page 2 of 2
EL150EX Switch/Terminal Kit
EL150EX-04033N
Effective 02-04
Section 15
00-02-0564
INSTALLATION INSTRUCTIONS
Please read the following information before installing. A visual inspection of this product for damage during shipping is rec-
ommended before mounting. It is your responsibility to have a qualified person install this unit and make sure it conforms to NEC
and local codes.
GENERAL INFORMATION
WARNING Terminal
Block
Warranty
A limited warranty on materials and workmanship
is given with this FWMurphy product. A copy of
the warranty may be viewed or printed by going to
www.fwmurphy.com/warranty/asp.
RE
GI
ST ER
E
Printed in U.S.A.
ELK150EX-04033N page 1 of 1
L12-9102B
Model L1200
Float Operated Electric
**
L1200 Series Patents 3970099, 4505288, 4573489
L12-9102B page 1 of 4
Specifications L1100 L1111 L1200 L1200N L1200NDVO L1200NDVOR
Body
• Standard: Electroless Nickel plated steel rA rA rB rB rB rB
• Optional: 316 Stainless Steel † rA rA rB rB rB rB
Pressure Rating
• 15 psi (103 kPa) [1.03 bar] Polyethylene Float
• 1500 psi (10.3 MPa) [103.42 bar] Stainless Float r r r r r r
• 2000 psi (13.8 MPa) [138 bar] BUOYGLAS™ Float r r r r r r
Temperature Rating
• Standard: -20/175°F (-29/79°C)
• Standard: -20/300°F (-29/149°C) r r r r r r
• Optional: -20/400°F (-29/204°C) * r r r r r
Specific Gravity
• Standard: 0.5 with BUOYGLAS™ float r r r r r r
• Optional: 0.65 with 304 Stainless Steel † r r r r r
• Standard 0.73 Polyethylene Float
Electrical
• Standard SPDT: 5 A @ 125/480 VAC (see p. 3 for full ratings) r r r
• Optional DPDT: 10 A @ 250 VAC (see p. 3 for full ratings) r r r
Wire: 18 AWG x 36 in. (1.0 mm 2 x 914 mm) r r r
O-Rings: Viton r r r r r r
Valve: Two-way snap-action vent type
• 1/8 in. (3 mm) orifice w/Viton “A” seat
r r r
• 1/8 NPT inlet; 1/4 NPT outlet
• 30-70 psi (207-483 kPa) [2.07-4.83 bar] operating pressure
Dump Valve Operator: Operates Murphy DV Series
r r
dump valves or similar.
VESSEL
L1200NDVOR
Dump Valve
valve stem forward thus opening the valve seat and releasing Union
condensate through the valve stem and out the drain. As the
condensate level drops, the L1200N pneumatic valve closes to Condensate Line (Out)
shut off the pressure to the dump valve causing it to close. Manual Drain Valve
L12-9102B page 2 of 4
Dimensions Accessories
11 in.
L1100 (279 mm) Adaptor Bushing 55050617
and
3-1/2 in.
(89 mm) for DVU150 and DVU175
2-1/16 in
L1200 (52 mm) 2-1/2 in
(64 mm)
1-1/16 in
2-3/16 in. See (27 mm)
Note 1: (56 mm) Note 2 1 NPT
L1100: 1-1/2 NPT
L1200: 2 NPT
Note 2: 1-9/16 (40 mm) 1/2 NPT See Float travel between Operate
Note 1 and Reset= 0.25 in. (6 mm).
SF option:
Switch operates on Rising Level
L1100: 1-1/2 (38 mm) 3-5/8 in. w/ float at horizontal centerline 2 NPT
L1200: 1-3/4 (44 mm) (92 mm) ±0.25 in. (6 mm). Material: 2-1/2 Hex bar stock C.R.S
2-11.5 NPT
1/2-20 UNF-2B
1/2 NPT 1-1/2 NPT Float travel between Operate (4 places)
and Reset= 0.25 in. (6 mm).
Note: 1-9/16 (40 mm) Switch operates on Rising Level 7.55 in. 3.5 in.
3-5/8 in. w/ float at horizontal centerline (192 mm) (89 mm) 7.01 in.
(92 mm) ±0.25 in. (6 mm). Material: Cast Steel, WCB
(179 mm)
Operator Assembly
p/n 15000940 Level
Switch
Tee
3-5/8 in. (92 mm) 5 in. (127 mm.) minimum
clearance is required for Bleed
3/4 Hex float movement. Valve
(See Note)
10-32 NF
1-3/8 in 3/8 in
(35 mm) (10 mm)
NOTE: The extension is used with the L1100 and L1200 only. One extension
is supplied with each unit. Use of additional extensions is not recommended
as they reduce the ability of the unit to operate for the stated specific gravity.
L12-9102B page 3 of 4
How to Order
L1100 and L1200 Series Replacement Parts (order by part number designation)
Build a complete model number using the diagram below. See L1100/L1200
example. See Specifications Chart on page 2 for standard and 15000893: BUOYGLAS™ float
optional features. 15000894: Stainless Steel float for L1200
15000937: Stainless Steel float for L1100
Example model number 15000124: SPDT snap-switch assembly
L1100 - ___ 15010213: L1100 counter balance assembly
15010214: L1200 counter balance assembly
Options L1200N
D = DPDT 15050420: Cam spring return
K = KALREZ Seals 15050421: Cam
SF = Stainless Steel Float 15000893: BUOYGLAS™ float
400 = 400°F (204°C) Service** 15000894: Stainless steel float for L1200N
15050453: Valve stem
15010189: Counter balance assembly
L1200NDVO and L1200NDVOR
Base Models 55050621: Regulator only
L1100* L1100SS 05706499: 20BPG-D-75 psi (0-517 kPa) [0-5.17 bar]
L1111 L1111SS 15010216: DVOA assembly (New rectangular style)
L1200* L1200SS* 15000940: DVO assembly (Old round style)
L1200N* L1200NSS* 00003341: Filter for regulator
L1200NDVO* L1200NSSDVO* 00003340: Regulator diaphragm kit
L1200NDVOR* L1200NSSDVOR*
Shipping Weights
* Stainless steel models carry Canadian Registration Number OF1476.2. L1100: 6 lb. (2.7 kg).
** Not available with DPDT snap-switch. L1111: 5 lb. 11 oz. (2.5 kg).
L1200: 6 lb. 6 oz. (2.8 kg).
L1200N: 5 lb. 5 oz. (2.4 kg).
L1200NDVO: 5 lb. 14 oz. (2.6 kg).
Complete SLS02 Systems L1200NDVOR: 6 lb. 10 oz. (3 kg).
Specify SLS02: 19 lb. 6 oz. (8.7 kg).
SLSO2A: Includes DVU150 valve
SLSO2C: Includes DVU175 valve Shipping Dimensions
SLSO2BA: Includes DVU2105 valve L1100: 14 x 5 x 3-1/2 in. (356 x 127 x 89 mm).
SLSO2BB: Includes DVU2115 valve L1111: 14 x 5 x 3-1/2 in. (356 x 127 x 89 mm).
SLSO2BC: Includes DVU2120 valve L1200: 14 x 5 x 3-1/2 in. (356 x 127 x 89 mm).
-LR: Less Regulator option L1200N: 14 x 5 x 3-1/2 in. (356 x 127 x 89 mm).
L1200NDVO: 14 x 5 x 3-1/2 in. (356 x 127 x 89 mm).
Accessories (order by part number designation) SLS02: 15 x 15 x 12 in. (381 x 381 x 305 mm).
15050375: Weld collar
15000892: Float shaft extension
55050617: DVU150/DVU175 adaptor bushing 2 NPT-M to 1 NPT-F
15051098: External Float Chamber
Warranty
A limited warranty on materials and workmanship is given with this
FWMurphy product.
A copy of the warranty may be viewed or printed by going to
www.fwmurphy.com/warranty.asp.
RE
GI
ST ER
E
L12-9102B page 4 of 4
1010629
Revised 05-24-11
Section 15
MLS Series Liquid Level Switches are float activated to operate an electrical SPDT reed switch for annunciation/pilot signal
for indication of high level to an annunciator, controller or PLC. The MLS connects directly into the gas scrubber wall and
can be used with a Murphy weld collar or Murphy external float chamber. The MLS Series is available in both 2”NPT and 1-
1/2” NPT models.
Product Dimensions
Specifications
.
Process Connection: 2” NPT (MLS-020)
1-1/2” NPT (MLS-015)
Fluid Density (Sg): 0.50 MIN
Pressure Rating: 2000 psig (13.8 MPa) [138 bar]
Materials:
Body: ASTM A351 CF8 (304 SS)
Cover: ASTM A351 CF8 (304 SS)
Other Wetted Parts: 304 or 316 SS
Meets NACE MR0175 for direct exposure to H2S
Process Temperature: -20 to 300oF (-24 to 149oC).
Electrical: 30VAC/VDC 75mA Form C SPDT
Conductor cross section AWG/kcmil min.: 26
Conductor cross section AWG/kcmil max.: 16
Accessories
Refer to MLS Installation and Operations manual for additional information.
External Float Chamber 15700799 Weld Collar 15050375
Operating Pressure: 2000psi (13.8MPa)[138 bar] Operating Pressure: 2000psi (13.8MPa)[138 bar]
How to Order
To order the MLS Series Level Switch please specify one of the products listed below:
MLS-020 (2” NPT)
MLS-015 (1-1/2” NPT)
MurCal
c
www.murcal.com
e-mail: sales@murcal.com
Shock and Vibration Switch
VS-96013B
Revised 10-03
Catalog Section 20
(00-02-0076)
VS2
VS2 Series
Designed to Detect Shock/Vibration
in 3-Planes of Motion
Fully Adjustable
VS2EX Includes Magnetic Latching Feature
R
Manual or Electric Reset
LISTED *
VS-96013B page 1 of 4
VS2 and VS2C ELECTRICAL
The VS2 and VS2C are designed for use in non-hazardous loca- Contact Rating:
tions. They have leaf type SPDT, double make contacts that can 5 A @ 480 VAC
S I DE VI EW FR ONT VI EW
Air Gap (Cover removed)
3-1/8 in. 4-11/16 in.
(80 mm) Permanent (119 mm) Adjustment
Magnet Armature
Slotted Sensitivity
Reset Adjustment
4-11/16 in. Push
(119 mm) Button
1/2 Conduit
Threads
VS2EX R
5-5/8 in. (143 mm)
3 in.
• NEMA 7/IP50 Specifications 4-40 NC
Screw
(76 mm)
Mounting
Terminal Holes
• Snap-switch Contacts
Permanent
®
• TATTLETALE Reset Button
Magnet 5-1/4 in.
(133 mm)
TATTLETALE® NC NO COM Mounting
Model VS2EX is housed in an explosion-proof enclosure with Reset Push
Button
Holes
threaded cover. This enclosure is CSA and UL listed for Class I, NC NO COM
Division 1, Groups C & D hazardous locations. In place of the Air Gap 6-3/8 in.
leaf type contacts, 2-SPDT snap-switches are used in this model.
(162 mm)
Sensitivity is externally adjustable and, when tripped, the VS2EX 3/8 in.
gives a TATTLTALE® indication on the reset button. It is con- (10 mm)
4 places
structed to meet NEMA 7 specifications. TOP VIEW
(Cover removed)
SIDE VIEW
VS-96013B page 2 of 4
VS2EXR R
ELECTRICAL
Contact Rating: Remote SPDT
5 A @ 125–480 VAC Reset Snap-switch
1/2 A @ 125 VDC 1/2 NPT
Conduit Slotted
1/4 A @ 250 VDC Sensitivity
2 A Resistive 30 VDC Adjustment
1 A Inductive 30 VDC
N.O. N.C. COM 4-7/8 in.
Remote Reset Rating: (124 mm) MORE LESS
115 VAC or 24 VDC (Specify) SENSITIVE SENSITIVE
1-3/4 in.
350 mA AC/DC (44 mm)
SIDE VIEW
10-5/8 in.
VS2EXRB
(270 mm)
8 in.
(203 mm)
VS-96013B page 3 of 4
How to Order Service Parts
When ordering service parts, specify both part number and descrip-
To order your VS2 Series model use the diagram below. tion in listing below.
Part number example: VS2EXR-24
PART NO. DESCRIPTION
___ – ___ VS2 and VS2C
20-00-0030 Movement assembly
20-00-0031 Glass and gasket assembly
Base Model 20-00-0032 Reset push button assembly
VS2 20-05-0021 Mounting clamp
VS2C 20-00-0261 Cable clamp assembly (1 each)
VS2EX 20-05-0465 2-Conductor electrical cable, 45 feet (13.7 meters)
VS2EXR 20-00-0137 5 clamps and 45 feet (13.7 meters) of cable
VS2EXRB VS2EX
NOTE: Order C-clamp 20-01-0091 Movement assembly
mounting kit as a separate
20-05-0087 Cover
line item for VS2EX and
VS2EXR. 00-00-0309 Cover gasket
20-01-0090 Snap-switch and insulator kit (1 switch per kit)
prior to September 1, 1995.*
Options 20-00-0288 Snap-switch and insulator kit (1 switch per kit) for models
manufactured on September 1, 1995 or later.*
24 = 24 VDC reset coil on VS2EXR or VS2EXRB
20-00-0289 C-clamp conversion mounting kit
15 = 115 VAC reset coil on VS2EXR or VS2EXRB
D = DPDT switch on VS2EXRB only VS2EXR
LC = Less case 20-00-0262 Movement assembly
LCC = Less cable and clamps on VS2C 20-05-0087 Cover
00-00-0309 Cover gasket
20-01-0090 Snap-switch and insulator kit (1 switch per kit)
prior to September 1, 1995.*
20-00-0288 Snap-switch and insulator kit (1 switch per kit) for models
Shipping Information manufactured on September 1, 1995 or later.*
VS2 and VS2C 20-00-0049 Reset solenoid assembly (115 VAC)
20-00-0234 Reset solenoid assembly (24 VDC)
Shipping Weight:
20-00-0289 C-clamp conversion mounting kit
VS2: 2 lb 8 oz. (1.1 kg)
VS2C: 7 lb (3.2 kg) VS2EXRB
Shipping Dimensions: 20-01-0090 Snap-switch and insulator kit (1 switch per kit)
VS2: 8-1/4 x 9-1/4 x 5 in. (210 x 235 x 127 mm) prior to September 1, 1995.*
20-00-0288 Snap-switch and insulator kit (1 switch per kit) for models
VS2C: 12 x 7 x 5-1/2 in. (305 x 178 x 140 mm)
manufactured on September 1, 1995 or later.*
VS2EX 20-00-0057 Inside snap-switch and insulator kit (1 switch per kit) for
model VS2EXRB-D prior to September 1, 1995.*
Shipping Weight: 4 lb 8 oz. (2 kg)
20-00-0058 Outside snap-switch and insulator kit (1 switch per kit) for
Shipping Dimensions: 8-1/4 x 9-1/4 x 5 in. (210 x 235 x 127 mm) model VS2EXRB-D prior to September 1, 1995.*
20-00-0287 Inside snap-switch and insulator kit (1 switch per kit) for model
VS2EXR VS2EXRB-D manufactured on September 1, 1995 or later.*
Shipping Weight: 5 lb 8 oz. (2.2 kg) 20-00-0290 Outside snap-switch and insulator kit (1 switch per kit) for model
Shipping Dimensions: 8-1/4 x 9-1/4 x 5 in. (210 x 235 x 127 mm) VS2EXRB-D manufactured on September 1, 1995 or later.*
20-05-0077 Adjustment shaft
VS2EXRB 20-00-0262 Movement assembly
Shipping Weight: 17 lb 8 oz. (7.9 kg) 20-00-0049 Reset solenoid assembly (115 VAC)
Shipping Dimensions: 12 x 12 x 10 in. (305 x 305 x 254 mm) 20-00-0234 Reset solenoid assembly (24 VDC)
* Models with date 0895 and before use old switch. Dated 0995 after, use straight snap-switch
arm, no rollers.
RE
GI
ST ER
E
Printed in U.S.A.
VS-96013B page 4 of 4