CERTIFICATE OF CALIBRATION | ss<”% Ss ISSUED BY SEAWARD ELECTRONIC LIMITED J3C-MRA ss DATE OF ISSUE. 10 January 2020 iw “buh CERTIFICATE NUMBER SEA04205572R / 1 _ E SEAWARD ares KC calibrationhouse Approved Signatory Bracken Hil M. CHURCHMAN ‘South West Ind. Estate am oe Soha MoO ‘SR8 2SW Telephone: 0191 5878737 Fax: 0181 §860227 email info@calibrationhouse.com Requested By: ARABIAN CALIBRATION DEV.REP.CO.LLC ‘SHARJAH UAE 24650 Order Number: PO15573 Manufacturer: GOSSEN METRAWATT Model: SECULIFE NIBP Description: BLOOD PRESSURE ANALYZER Serial Number: 73609911335 Asset ID: ‘Seaward Reference: 145924 Temperature: 200°C Humidity 39.%RH Date Received: 16 December 2019 Calibration Date: 08 January 2020 Calibration Category: ‘A: WITHIN SPECIFICATION AT THE POINTS TESTED, NO ADJUSTMENT NECESSARY Comments: ‘The ambient temperature and relative humidity throughout the calibration were 20 +/-2 degrees and 25 - 50% RH Static pressure simulation by applying a known excitation voltage and measuring the calculated value. ‘Temperature and Amplitude values are taken by direct measurement. ‘The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a confidence level of approximately 95%. The uncertainty evaluation has been carried out in accordance with UKAS requirements “This cerca is issued in accordance withthe laboratory accrediation requirements ofthe United Kingdom Accreditation Service. It provides traceabilty of measurement to the SI system of units andor fo unis of measurement realised atthe National Physical Laboratory or ‘ther recognised national metrology institutes, This certificate may not be reproduced ather than in ful, except with the prior writen approval ‘ofthe issuing laboratory CALIBRATION RESULTS UKAS Approved Calibration Laboratory 0809 Model: SECULIFE NIBP Serial No: 735A9911335L FUNCTION Pressure Measurement (mmHg) ‘Simulated 18P Output (mV) Su /V/ mmbg @ 10 V Excitation -10 mmHg ‘Ommlig 100 mmHg 200 mmHg 300 mmHg 400 mmHg 40 pV / V / mmbig @ 10 V Excitation 100 mig 400 mmHg ECG Performance Ouput (mV) Lead 1 Respiration Baseline Resistance (12) Respiration Delta Resistance (22) ‘Temperature Simulation (K2) YST 400 :0°C YSI 400 : 37°C YSI 400: 40°C YSE700(1) : 0°C YSI-700(1) : 24°C YSI-700(2) : ACTUAL BEFORE AFTER urs 00 0.0 -05 100.0 100.1 985 200.0 2004 1975 300.0 3008 2365 400.0 401.1 395.5 495.0 4964 489.55 400.0 401.4 3955 300.0 301.0 236.5 200.0 2006 1975 100.0 1003 98.5 0.0 00 “05 0500 -0.505 -0.25 0.000 0.000 0.25 5.000 4.995 475 10.000 9.990, 97 15.000 14.984 46 20.000 19.979 195 40.000 40.031 38 16000 160.11, 156 2.750 2.767 2.695 1000 1001.9 950 3.000 2.739 27 7.387 7.355 732 2.355 2.354 2345 1815 1815 1.807 1.355 1.354 1349 1.200 1.199 1.195, 19.98 19.897 19.88, 6.270 6.263 6.242 4.834 4.836 4813 3.609 3611 3.594 3.195 3.204 3.182 94.98 95.076 9451 3132 31.332 3118 2427 2427 24.7 183 18.194 18.06 16.5 16.54 16.09 0s 1015 2025 3035 4045 500.45 4045 3035 2025 1015 os 075 025 5.25 103 184 205 2 164 2.805 1050 33 7.394 2.365 1.823 1.361 1.205 20.08 6.298 4.855 3.624 3.208 95.45 31.46 2437 182 16.21 CERTIFICATENUMBER, ‘SEAOA2055/2R / 1 Pav of 2 PAGES. UNCERTAINTY 0.25 mmHg (0.25 mmHg 0.25 mmHg 025mmHg 0.25mmHg 0.25 mmHg 0.25mmHg (025mmHg 0.25mmHg 025mmHa 025mmHg saw S7W ei 64 e7w 7A a4 e7w sow os3.0 59m oso 380 320 26a 240 sao asa esa 530 430 on2ka. 470. 390 sa 20a

You might also like