4.4 Torroja Half-Mile Viaduct, Unbuilt, 1956

The structural concept:

36 Dr C. Caprani
IStructE RoI Branch

4.5 Torroja Operating Theatre, Madrid University

37 Dr C. Caprani
IStructE RoI Branch

5. Preliminary Analysis

5.1 Preliminary Loading


General philosophy: keep it conservative, yet realistic, at preliminary design stage.

Imposed Loading

Based on BS 6399: Parts 1 & 2;


Choose the highest where options exist;
No live load reduction factors should be allowed for.

Some common loads should be remembered:

Use Load (kN/m2)


Commercial speculative offices 5
Light office 2.5
Residential 1.5
Car park 2.5
Plant rooms 7.5

Extract from BS6399: Part 1: 1996: