Table A: Key parameters of importance in Natural Gas PW
treatments Adapted from [ CITATION Pro14 \l 1033 ].

Natural Gas
Parameter
PW
Oil/grease, ppm 40
pH 4.4-7.0
Total Suspended Solids (TSS), ppm 5500
Total Dissolved Solids, (TDS), ppm 360,000
Total Organic Carbon (TOC), ppm 67-38,000
Chemical Oxygen Demand (COD),
120,000
ppm
Density, kg/m3 1020
Arsenic, ppm 0.005-151
Lead, ppm 0.2-10.2
Chromium, ppm 0.03
Oil droplet size, µm 2-30

Table B: Typical Characteristics of Temane Produced Water

Values before Values After


Parameter Biocide biocide
Injection Injection
4.9-5.2
PH 5-5.9
<0.001
TEG mass % <0.001
1.004
Density 1.01
56
TSS (mg/l) 360
0.8
Salinity % 0.6-0.8
7
Conductivity (mS/cm) 10
98.5
Fe (mg/l) 450
Total 0.015
Hydrocarbons(mass%) 0.189
Bacteria count <100
(Bacteria/ml) <100

A
Page |B

Table C: Parameters limits in wastewater of Mozambique

Effluent Limits
Parameters
Total hydrocarbon
content(mg/l) 10

pH 6-8

BOD (mg/l) 25

COD (mg/l) 125

TSS (mg/l) 35

Phenols (mg/l) 0.5

Sulfides (mg/l) 1

Heavy metals a.(mg/l) 5

600 average, 1200


Chlorides (mg/l) maximum

Source:[CITATION Min04 \l 1159 ]