NATIONAL INSTITUTE FOR BIOTECHNOLOGY & GENETIC ENGINEERING

I,
(NIBGE) P.O Box # 577, Jhang Road, Faisalabad, Pakistan
Tel: (0092-41) 2651475-79 (5 Lines ); Fax: (0092-41) 2651472; URL: u,wrv.nibse.ors

Soil and Environmental Biotechnology Division


EPA registeted. IS-O 90Ql:2015 cprt-ified
1-'
Ref. No. NIBGE/PIBS/SEBD/BTL12023I7,' Dated: ll-Jan-2023
SAMPLE CODB: 00068
CASH MEMO NO: 0092

Analysis Report of Drinking Water from Bismillah Textiles Limited Khurrianwala, Faisalabad
Sample was collected by NIBGE (Drinking Point near Embroidery) on02'Jan-2023

wHo wHo
Standards Standards
Parameters Values for Parameters Values for
L) Drinking Drinking
water
water
pH 7.4 6.5-8.5 Chromium (mg/l) < 0.01 0.05
Ca- Hardness (mg/l) 24 NG Cadmium msll) < 0.002 0.003
Total Color Nil NG Copper (mg/l) < 0.004 2
Turbidity (FAU) < 1.0 NG Lead (mg/l) < 0.003 0.01
Total Hardness (mg/l) 25 NG Mercury (lmg/l) < 0.000 0.001
TDS (me/l) 332 1000 Nickel(mg/l) < 0.002 0.02
Chlorides (mg/l) r49 250 Ninc (mgll) < 0.02
Phenol (mg/l) Nil 0.02 Arsenic (mg/l) < 0.001 0.01
Fluoride (mg/l) 0.5 1.5 Manganese (mg/l) < 0.002 0.1
Cyanide (mgll) < 0.004 0.07 Aluminum < 0.002 0.2
Boron (mgll) < 0.004 0.5 Barium .mg/l) Nil 0.7
Nitrate (mg/l) 27 50 E.coli (ctu/100m1) Nil (0cfrr/100m1)
Nitrite (mg/l) < 0.005 0,5 Fecal Coliform Ni1 NG
Chlorine (mg/l) 0.1 NG
TDS: Total Dissolved Solids, NG: Not Given, FAU: Formazin Attenuation Unit

Analysis were done according to Standard Methods for the Examination of Water & Wastewater
L-r American Public health Association (APHA); American Water Works Association (A W W A) and Water Environment
Federation $fED, 2l't Edition 2005,
Heavy metals were analyzed were done according to Methods of Merck Kits by using Spectroquant @NOVA 60 instrument.
Microbial analyses were done according to Merck Microbiology Manual 126 Edition.

l. The analytical test report is based solely on the particular sample(s) collected by NIBGE and should not be reproduced in parl.
2. The report is valid for 90 days from the date ofissue.
3. Sampling has been performed by the NIBGE and MBGE accepts the responsibility that the samples(s) supplied is/are truly
representative sample(s) bath of stock entire production.
4. White NIBGE, agrees to take roasonatle precaution to ensure validity of its test results. It assumes no liability for the accuracy
thereofbeyond the amount ofthe fee charged for the analyticaVtest.
5. The party shall assume fulI responsibility for the ethical use of results in the analysis/test report and the laboratory shall be held
free frdm any and all claims which may result from the use of such data by the party of others.
6. After completion of report the sample will be preserved for one month unless agreed otherwise.
The contents ofthe report cannot be, in any manner, used for the publicify ofthe product or any advertisement.