You are on page 1of 8

Branch offices 17.

204-205, Megapolis Square,


579, M G Road,
21 7. SCO 1-2-3, Second Floor, Sector 17B, INDORE – 452 001.

ACCL
7
20 CHANDIGARH – 160 017. Tel : (0731) 4999 891 / 892
Tel : (0172) 305 8631 / 32 / 33 / 34 / 35
8 9
23 22 Fax : (0172) 501 9008 18. MF-2, Datta’s Lords House,
Jammi Chettu Street, Mogalrajapuram,
8. 507-510, Vth Floor, Soni Paris Point, VIJAYAWADA – 520 010.
11 10
24 17 Jai Singh Highway, Banipark,
Tel : (0866) 661 1393, 664 6393
13 19 JAIPUR – 302 016.
Fax : (0866) 669 9393
12 6
Telefax : (0141) 511 3129, 510 1179
26
19. Plot No. 359,
18 9. 209-A, 2nd Floor, Cyber Heights,
Saheed Nagar, 2nd Floor,
5

16
14
Opp. Indira Gandhi Pratishthan,
Vibhuti Khand, Gomti Nagar
LUCKNOW - 226 010.
BHUBANESWAR – 751 007.
Tel : (0674) 254 0623
Automatic changeover
15 25
Tel : (522) 319 2031 / 32 / 33
Area offices with current limiter
10. 202 & 203, 2nd Floor, Sunrise,
Head office Forum 100, Burdwan Compound, Lalpur, 20. Unit - 1 & 2 , Vijay Park,
1. 61 & 62, 6th Floor, RANCHI - 834 001. Main Chakrata Road,
Kalpataru Square, Kondivita Road, Tel : (651) 660 5400 DEHRADUN - 248 001.
Off Andheri-Kurla Road, Andheri (E), Uttarakhand.
11. A 101-102, Mondeal Heights,
MUMBAI – 400 059. Tel : (0135) 661 6100
Besides Novotel Hotel, Sarkhej
Tel : (022) 3041 6200
Fax : (022) 3041 6201 Gandhinagar Highway (S G Highway), 21. Cabin No. 9,
Website : www.legrand.co.in AHMEDABAD – 380 015. Second Floor,
Tel : (079) 6134 0555 e1ded7
Madhok Trade Centre,
Madhok Complex,
Regional sales offices 12. 402, Swastik Chambers,
Near Ashwamegh Marriage Hall, Ferozpur Road,
2. A-25, Mohan Co-operative Behind HP Petrol Pump, LUDHIANA – 141 001.
Industrial Estate, Mathura Road, Off Karve Road, Erandwane, Tel : (0161) 277 0301 / 2 / 3 / 4
NEW DELHI - 110 044. PUNE – 411 004.
Tel : (011) 3990 2200, 2699 0046, 22. House No. 97, Ground Floor,
Tel : (020) 6729 5601 / 602 Rajgarh Main Road,
(011) 2699 0028 / 29 / 30 / 31 Fax : (020) 6729 5604
Fax : (011) 2699 0047 Opp. City Heart Nursing Home,
13. Plot No.95, II Floor, Shreyash Heights, GUWAHATI – 781 007.
3. Bhakta Towers, 2nd & 3rd Floor, VIP Road, Ramdaspeth, Tel : (0361) 245 8498
Plot No. KB 22, Sector-III, Saltlake,

CIN U31909MH2010PTC206487
NAGPUR – 440 010.
KOLKATA – 700 098. 23. 94, Udham Singh Sarani,
Tel : (0712) 662 7857 / 858
Tel : (033) 4021 3535 / 36 Ground Floor, Ashrampara,
Fax : (0712) 662 7859
Fax : (033) 4021 3537 SILIGURI – 734 001.
14. 10 B, (10th Floor), Prestige Center Court Tel : (0353) 264 1067
4. C/203, Corporate Avenue, Atul Projects,
Near Mirador Hotel, Chakala, Of·ce Block Vijaya Forum Mall, #183,
N.S.K. Salai, Vadapalani 24. 405, City Centre, Sosyo Circle,
Andheri Ghatkopar Link Road, Udhana Magdalla Road,
Andheri – East, MUMBAI – 400 099. CHENNAI – 600 026.
Tel : (044) 6612 2800 / 2362 3125 / 35 / 45 SURAT - 395 002.
Tel : (022) 3385 6200 / 62301000 Tel : (0261) 263 3861
Fax : (044) 2362 3165
5. Ferozes Manor,
15. J. B. Manjooran Estate, Door No 50/1107A9, 25. Aparna Towers, 1st Floor,
Situated at 58 Hospital Road,
3rd Floor, Bye Pass Junction, Edappally, 2/3, Bypass Road,
Shivaji Nagar,
BANGALORE – 560 001. COCHIN – 682 024. MADURAI – 625 010.
Tel : (080) 6822 0000 Tel : (0484) 280 1921 / 2921, 658 0921 Telefax : (0452) 230 8414
Fax : (0484) 280 1921 / 2921

AABBCC/0000/00/2019
6. 205-208, 2nd Floor, 26. 404, Eshwar Plaza,
Block - II, White House, 16. B-5, 1st Floor, Thirumalai Towers, Dwaraka Nagar, Main Road,
Kundan Bagh, Begumpet, 723, Avanashi Road, Beside Bata Show Room,
HYDERABAD – 500 016. COIMBATORE – 641 018. VISHAKHAPATNAM – 530 016.
Tel : (040) 2341 4398 / 67, 4567 1717 Tel : (0422) 222 3634 / 0283 Tel : (0891) 663 5652
Fax : (040) 4567 1730 Fax : (0422) 222 3164 Fax : (0891) 663 9363

Technical assistance from Legrand


Telephonic technical assistance for selection
of products, technical information, guidance,
wiring diagrams and estimation is now made
available to you at each Regional Office. Contact
the Technical Officer of Legrand at the following
telephone numbers
New Delhi : Tel.: (011) 2699 0028, 3990 2200

Seamless and uninterrupted


Kolkata : Tel.: (033) 4021 3535 / 36
Mumbai : Tel.: (022) 3385 6200
Bangalore : Tel.: (080) 6822 0000
Hyderabad : Tel.: (040) 2341 4398 / 67, 4567 1717
For other places, contact the nearest
Regional / Branch / Area offices

customer.care@legrand.co.in
switchover for smart spaces
LIVE THE
ADVANTAGE
The pace of today’s life demands continuous upgrades in
efficiency and ways to live smarter. At Legrand, we
anticipate your needs with technologically advanced
products, investing as much as 5% on Research and
Development to deliver superior electrical and digital
building infrastructure.

As global specialists, we make things that are not just


essential but actually desirable. Our engineering is
exacting, and is fuelled by design thinking. We call this
Designeering. It’s not just a deep understanding of our
markets, but delivering innovation and technology for
uninterrupted living.

Such expertise helps us fulfil your needs.It also ensures


that we’re a step ahead, launching innovative products that
change the way you look at form and function. The
Automatic Changeover with Current Limiter (ACCL) is one
such product which automatically switches power between
main supply and standby generator.
ACCL
Automatic changeover
with current limiter

Legrand ACCL is a fully automatic high


precision microcontroller based system
ideally suited for energy conservation of
standby generator used in multi-storied
apartments, commercial complexes, etc.

Generally the standby generator is


selected to meet the demands of critical
and essential loads of consumers
and hence the ratings of the generators
are lower than the connected load i.e.
power from the mains supply system.
It is therefore necessary to stagger the
connections and monitor the power
drawn by each consumer so that the
generator does not get overloaded.
Legrand ACCL has been specially
developed to meet this requirement and
has following features, specifications and
functions.
Automatic changeover with current limiter

Automatic changeover with current limiter


02 03
FEATURES
>
Buzzer and
> LED light indication
> Automatic source of status-Overload,
Intelligent change over Mains, Gen
micro-controller between Mains &
based design Generator supply

>
Current limitation
function prevents
>
over loading of the Direct mount on
generator DIN rail channel

> >
Neutral Break before >
isolation make change Manual reset for
over system restoring supply in
Automatic changeover with current limiter

Automatic changeover with current limiter


sleep mode

04 05
FUNCTIONS

> >
When the Mains supply is available When the load is within the set
the load is connected to the Mains limit, the generator continues to
supply and the consumer can draw supply the load.
the full load as per the sanctioned
rating.
>
In an unlikely event of the
>
When the Mains supply fails and consumer not switching off the
Standby Generator supply is nonessential loads to reduce it to
available within the “Set limit”, supply to
the load from the generator is
>
The consumers are connected to automatically disconnected after
the generator depending upon the 5 cycles of interruptions
transfer timing, in order to limit the (after auto cut-off, ACCL goes into
sudden load on the Generator. The sleep mode).
unit monitors the current at
>
factory“Set limit”. The supply from the Generator to
the load can be restored only after
>
If the current exceeds the limit, the the Generator connection is reset
load is disconnected for 10 seconds by pressing RESET button or
as a warning and then, Switching OFF/ON Generator.
automatically reconnects it. This
cycle of interruptions repeats for
Automatic changeover with current limiter

Automatic changeover with current limiter


five time in which consumer is
expected to switch off the non-
essential loads and reduce it to the
set limit.

06 07
LED and Buzzer Indications ACCL models available

Condition Mains LED Mains LED Mains LED Buzzer Product Description Mains Rating Gen. Rating Recommended MCB Rating MRP
(Green) (Blue) (Red) Code (Set Limit)
Mains Generator
Only mains supply available Off

405300 SPN 30/3 A ACCL 30 A 3A 32 A 3A 1990


Mains and DG supply available Off

405301 SPN 30/4 A ACCL 30 A 4A 32 A 4A 1990


Only DG supply available Off

405302 SPN 30/5 A ACCL 30 A 5A 32 A 5A 1990


Change over from mains to DG On for 1 sec

405303 SPN 30/6 A ACCL 30 A 6A 32 A 6A 1990


Changeover from DG to mains On for 1 sec

405304 SPN 30/9 A ACCL 30 A 9A 32 A 9A 1990


3 beeps In 5 sec
DG Overload - ON cycle Blinks
(Each beep for 1 sec)
405305 SPN 30/12 A ACCL 30 A 12 A 32 A 12 A 1990
20 beeps in 10 sec
DG Overload trip - OFF cycle Blinks
(Two beeps in 1 sec) 405306 SPN 30/15 A ACCL 30 A 32 A
15 A 15 A 1990
Continuous beeps
DG trip (Autocut OFF) 405307 SPN 30/20 A ACCL 30 A 32 A
for 10 sec 20 A 20 A 1990

ACCL Sleep mode Blinks Blinks 405308 SPN 30/30 A ACCL 30 A 30 A 32 A 30 A 1990

Note: Available in 1.5 & 2.5 amps current ratings. For further details, please consult your nearest sales office.

MAINS MAINS MAINS

OL GEN OL GEN OL GEN

Mains ON Genset ON Overload

Overload Sensing Sequence


On 5 Sec
Overload

1st 2nd 3rd 4th 5th


Time Time Time Time Time
Wait for Reset
Automatic changeover with current limiter

Automatic changeover with current limiter


Off 10 Sec

R
RESET To switch on reduce excess load & press reset button

08 09
Technical specification Wiring Diagram

Standard conformity: IEC 60947-6-1 Pollution degree: II


TO Load

No. of poles: Single phase (1P+N) Change over delays:


Mains to D.G. - 4 second typical (If
Gen Mains Load
Rated voltage (Ue): 240 V AC, 50 Hz D.G. is already ON)
PHASE
SCPD2 SCPD1
Mains to D.G. - 10 to 12 Seconds
Rated current (In): 1) Mains : 30 A,
typical (If D.G. is turned ON after
2) DG: 3 A to 30 A Mains Failure)

Transfer time: 10-12 sec. D.G. to Mains - 4 Seconds


GEN NEUTRAL Mains
Restoring time: 4 sec. Overload warning - 5 second ON (to Gen Mains Load
Trip) & 10 second OFF (to Recovered)
Indication: Mains, Generator, Load,
To Load
Overload

Ref. Std.: Single Phase


Duty: Uninterrupted
IEC 60947-6-1 Class - PC, Iq-3kA
Ue 240V~, In 30A SCPD1-32A, SCPD2-XXA
Electrical life: 6000 operations AC 31A, 50 Hz Made in India

Ambient temp.: -5 ·C to + 55 ·C

Mounting: DIN RAIL (35 mm) General Dimensions


Mounting position: Vertical / 63

31
Horizontal

Protection class: IP20 RESET

106

45
Terminal capacity: 10mm² MAINS

OL DG

Weight: 335g
Automatic changeover with current limiter

Automatic changeover with current limiter


31
68
49

10 11
Automatic changeover with current limiter

12
Notes

Automatic changeover with current limiter


13

You might also like