Professional Documents
Culture Documents
Steffen Graber
Pepperl+Fuchs
Specify an optional power distribution technique for use over the 10 Mb/s single twisted pair link
segments in conjunction with 10Mbps single-pair PHYs.
Content:
Associated apparatus (e. g. power supply): Cable: Intrinsically safe apparatus (e. g. field device):
Maximum output voltage Uo Inductance per unit length LC´ Maximum input voltage Ui
Maximum output current Io Capacitance per unit length CC´ Maximum input current Ii
Maximum output power Po Resistance per unit length RC´ Maximum input power Pi
Maximum allowed external inductance Lo Maximum internal inductance Li
Maximum allowed external capacitance Co Maximum internal capacitance Ci
If the external inductance as well as the external capacitance of the connected equipment
are > 1 % of the specified values, the specified values of Lo and Co shall be reduced to 50 %.
Lo / Ro = 32 * 40 µJ * RS / (9 * Uo²)
Powered Ex i Spur
spur, up to
200 m
Zone 0 / Division 1
• Spur cabling:
• A maximum spur cable length of 200 m is required for process industry applications.
• Preferred hazardous area protection method for a spur is intrinsic safety (Ex i).
500 µH
560 nF
26.5 Ω 560 nF
Spur Port:
26.5 Ω
560 nF
560 nF
500 µH
23.5 Ω
• Input: Uo = 17.5 V, Io = 380 mA, LC’ = 1 mH/km, RC’ = 33.333 Ohm/km, CC’ = 45 nF
• Result: Lo = 10 µH, Co = 170 nF @ 200 m cable
• Depending on other use cases there will be several other power profiles, which need to be defined.