You are on page 1of 2

Raise your expectations.

Quantech™ chillers deliver efficiency and dependability in days, not weeks.


Quantech – a quantum leap forward.
Air-Cooled Chillers

For more information visit us at: quantech-hvac.com

fast efficient dependable fast efficient dependable


Quantech is a trademark of Johnson Controls, Inc. Quantech products are manufactured as part of the Johnson Controls product portfolio. ©2015 Johnson Controls, Inc.
PUBL 7545
QUANTECH. The quickest way to cool.

Quantech™ air-cooled chillers offer a QTC2 QTC3 QTC4


fast, efficient and dependable solution
with a low lifecycle cost – delivered in 15-50 TR 55-175 TR 160-210 TR
QTC2 AIR-COOLED SCROLL CHILLER QTC3 AIR-COOLED SCROLL CHILLER QTC4 AIR-COOLED VARIABLE
days, not weeks or months. The QTC2 provides chilled water for all air conditioning The QTC3 offers full load and part load efficiencies that
SPEED DRIVE SCREW CHILLER
applications using central station air handling or terminal meet or exceed ASHRAE 90.1-2013 and operates at The QTC4’s combination of state-of-the-art technologies
units, and it meets or exceeds ASHRAE 90.1-2013 ambient temperatures up to 125°F and down to 0°F. in compressors, heat exchangers (evaporator and
efficiency standards. condenser), condenser fans and chiller controls enable
• Delivered from inventory in two to five business days
it to deliver market leading part load efficiency (IPLV or
Fast • Delivered from inventory in two to five business days
• 18-40% annual energy cost savings NPLV) while meeting or exceeding ASHRAE 90.1-2013
•R
 -410A refrigerant and low charge to help earn a point full load efficiency standards.
• Sturdy, corrosion-resistant condenser coils that are
• Delivery in two to five business days for LEED E&A Credit 4
easily washable • Variable speed drive screw compressors
• Faster installation and commissioning • Factory-designed and installed pump package including • Simple replacement of condenser coil if damaged – Dramatically reduce sound levels at
with native communications protocols pump, strainer, flow switch, circuit balancing valve, off-design conditions (up to 16 dBA)
expansion tank • Compact, factory-packaged chilled water pumps – Reduce energy consumption
• Heat recovery at the chiller
•F
 actory-installed BACnet MS/TP interface to reduce • 25-50% annual energy cost
QTC4 EFFICIENCY savings
VS. ORDINARY CHILLER

Efficient
kW/Ton Annual Hours (%)
commissioning time and complexity •G
 reen refrigerant and low charge to help earn a point
• Hybrid falling1.20
film type evaporator for optimal
–20

• Reliable operation in a variable primary flow system for LEED E&A Credit 4 –18
efficiency and refrigerant charge
1.10
QTC4 EFFICIENCY VS. ORDINARY CHILLER
• Meets or exceeds ASHRAE 90.1-2013 • Native communication protocols to reduce installation kW/Ton
1.00
Annual Hours (%)
–16

• Lighter and smaller to minimize installed cost and • Micro-channel0.90 type condenser for maximum
–14

cost and commissioning time 1.20 –20

• 18 to 50% annual energy cost savings maximize usable space heat


1.10 transfer and minimum refrigerant
0.80 –18
–12
charge
–10

Key technology elements


0.70 –16
1.00

Key technology elements


–8
• Low refrigerant charge helps earn • Optional
0.90
condenser
0.60 fans with–14variable speed
–6
drives
Refrigerant Management LEED credit • S
 croll compressors – reliable, proven design and two for0.80even higher chiller part load
–12
efficiency
•T
 ube and fin condensers, brazed plate evaporators,
0.50
–4
–10

scroll compressors independent circuits for partial redundancy 0.70 0.40 –2


• Lower lifecycle costs • Variable
0.60
primary
0.30
flow (VPF) system –8
to –0
reduce the
chilled liquid flow to match the building demand
–6
• Louvered enclosures for added protection • H
 eat exchangers – high efficiency brazed plate 0.50
10 20 30 40 50 60 70 80 90 100
Chiller Load (%) –4
evaporators, advanced microchannel condensers • Built
0.40
to order and delivered in–2 8-10 weeks Ordinary Chiller QTC4 Chiller

• Completely self-contained and designed for


Dependable
The QTC4 chiller features the industry’s lowest kW/Ton
0.30 –0

outdoor installation • Low-sound fan 10 20 30 40


at both design and off-design conditions.
50 60 70 80 90 100
Chiller Load (%)
QTC4 EFFICIENCY & ANNUAL ENERGY COST
• Includes hermetic scroll compressors, a liquid cooler, • Completely
 self-contained and designed for outdoor Ordinary Chiller QTC4 Chiller
Chiller Efficiency (IPLV) Annual Energy Cost
The QTC4 chiller features the industry’s lowest kW/Ton
• Smaller, lighter, quieter and low-maintenance air-cooled condenser, a charge of R-410A refrigerant, installation 20and off-design conditions.
at both design
19 50% $90K

and a weather-resistant microprocessor control center, • Includes


 zero-ozone-depletion refrigerant (R-410A),
QTC4 EFFICIENCY
18& ANNUAL ENERGY COST
• A track record of exceptional reliability, the Chiller Efficiency 17
(IPLV) Annual Energy Cost
all mounted on a rugged, formed-steel base hermetic scroll compressors, a liquid evaporator, 20 $75K
result of over 140 years of engineering excellence 19
16
50% $90K
air-cooled condenser and a weather-resistant 18
15

microprocessor control center, all mounted on a formed 17


14 25% $60K
QTC3 EFFICIENCY & ANNUAL ENERGY COST 13
$75K
steel base Chiller Efficiency (IPLV) Annual Energy Cost
16
12
17 15
$45K
40% 11
14 25% $60K
16
QTC3 EFFICIENCY & ANNUAL ENERGY COST 13 10
15(IPLV)
Chiller Efficiency Annual Energy Cost 9
12 $30K
17 14
18%
Typical $45K
Typical Chiller
40% 11 QTC4
10-20 Year Old Today
16 13 Chiller
10
The QTC4 chiller exceeds typical chiller IPLV in the
15 12

Cooler. Quicker. Quantech.


9 market today by up to 25% on $30Ka new construction
18%
14 Typical project or up to 50% when replacing an older chiller.
Typical Chiller QTC4
11 10-20 Year Old Today hours, Energy rate 0.0102/kWh, 250 tons Based on average efficiencies.
Note: 5000 operating
Chiller
13
10 The QTC4 chiller exceeds typical chiller IPLV in the
12 market today by up to 25% on a new construction
9
10-20 Year Typical Chiller QTC3 project or up to 50% when replacing an older chiller.
11 Old Chiller Today Note: 5000 operating hours, Energy rate 0.0102/kWh, 250 tons Based on average efficiencies.
10 Note: 5000 operating hours, Energy rate 0.0102/kWh, 150 tons Based on average efficiencies.

9
10-20 Year Typical Chiller QTC3
Old Chiller Today

Note: 5000 operating hours, Energy rate 0.0102/kWh, 150 tons Based on average efficiencies.

You might also like