RIELLO ARR AY SE
A Carrier Company
RIELLO ARRAY SE
MANAGEMENT
• 7” color touch screen
BOILER
• Graphic display of actual input rate for cascaded
system or individual boilers
• User-Friendly tex t driven menus to monitor the
boiler functions
• Immediate access to Supply, Return, Flue
temperature and Fan speed
• Management of cascade systems up to 8 boilers
MANAGEMENT
• Simple access to Set tings, Commissioning,
CASCADE
Maintenance procedures and Error Log through the
touch screen
• Graphic outdoor reset adjustment
• In addition to integrated Modbus, In addition to
integrated Modbus, optional BMS gateways available
for BACnet, Metasys and Lon Works protocols
• Control provides remote operation through 0-10Vdc
MANAGEMENT
set point control DHW
VENTING
COMBUSTION
UNI V E R S A L IN TA K E A DA P T E R ADVANCED PRE-MIX BURNER
A L L O W S C OMBUS T I O N A IR
F R OM B O IL E R R O OM O R The Riello Array pre-mix combustion system
SE A L E D C OMBUS T I O N A IR is comprised of a stainless steel mesh burner
DUC T E D F R OM O U T SIDE integrated with a modulating gas valve and
high per formance variable speed fan.
The propor tional control guarantees a
consistent air to fuel ratio throughout the
entire range of modulation resulting in clean,
UNI V E R S A L V E N T ef f icient combustion.
A DA P T E R F O R C P V C ,
P P, O R A L 2 9 - 4 C
S TA INL E S S S T E E L
ADVANTAGES OF A 10:1
TURNDOWN RATIO
• Produces energ y savings by minimizing on/
of f cycles
• Makes the boiler more suitable for
integration with renewable heat sources
• Lowers CO 2 emission and creates a more
environmentally responsible system
• Increases the application flexibilit y by
creating a wider Btu range
• Produces high ef f iciency and low
emissions at par tial heating loads
RIELLO ARRAY SE
CASCADE
ARRAY SE can be installed in cascade
• Easily connect up to 8 boilers together without any additional control device
• High performance algorithms ensure accurate temperature control to match system demand
• Proprietary algorithms also optimize cascaded system operating efficiency for maximum fuel savings
• Versatile solution for light commercial buildings or large domestic properties
• Cascade automatically rotates lead boiler for uniform wear across all boilers
• During maintenance, individual units can be taken offline without interrupting the remaining system
• Spare units in the system can be withheld as back-up boilers for emergency conditions
• Up to 80:1 system turndown allows design flexibility and ultra-high efficiency for partial load heating conditions
BACNET /
LONWORKS /
MODBUS METASYS
BMS
MODBUS
CASCADE UP TO 8 BOILERS
(UP TO 64 UNITS WITH CASCADE OF CASCADE)
POWER RANGE
AHRI Overall
Input Power Thermal Dimensions (*)
Model Turndown Ratio
MBH Efficiency WxHxD
% (inches)
(*) Mounting feet may be removed during installation to reduce the overall height by 2”. Feet must be re-installed once
boiler is in its final installation location.
DIMENSIONS
B
C D
TOP VIEW
The manufacturer strives to continuously improve all products. Appearance, dimensions, technical
specifications, standard equipment and accessories are therefore subject to change without notice.