You are on page 1of 4

Project: Created on: 3/05/2023

Project number: Created by:

Technical data with motor


Submersible sewage pump FA 60.83V FKT 63.1-10/56G

Pump
Pump type FA 60.83V Installation type Suspension device
max. possible 605 mm DN600/2RK
standard 605 mm Free passage 125 mm
Impeller Ø
designed 605 mm Pressure rating PN10
min. possible 485 mm Suction port Rated diameter DN700
Nominal speed 700 1/min Standard EN1092-2-S
Frequency 60 Hz Pressure rating PN10
Impeller type Four-channel Discharge port Rated diameter DN600
Impeller construction Closed Standard EN1092-2-D

Weights
Weight of pump end max. 2040 kg Weight of unit max. 5720 kg
Weight of motor 3520 kg

Materials
Pump housing EN-GJL-250 Suction ports EN-GJL-250
Stationary wear ring 1.4470
Impeller EN-GJS-500-7
Mobile wear ring 1.4470

Motor
Motor name FKT 63.1-10/56G Number of poles 10
Rated power 260 kW Rated speed 712 1/min
Power input with rated power 275.1 kW
Rated voltage 460 ~3 V
Current input with rated power 431.7 A
Efficiency with rated power 94.5 %
cos phi with rated power 0.8 Rated frequency 60 Hz
cos phi with starting 0.19 Operation type wet S1
Starting current, direct starting 2050 A Operation type dry S1
Starting current, star-delta 683.3 A Max. fluid temperature 40 °C
Starting torque 3054 Nm Starts per hour max. 10
Inertia moment 19.86 kg m² Degree of protection IP 68
Sel. explosion protection Ex-number ATEX=- / FM=- / CSA=-
Ex-designation ATEX=- / FM=- / CSA=-
Motor connection cable 2X 3x70/35 + 7x1,5 NSSHÖU

Duty point data


Volume flow 1539.2 l/s Fluid Water
Head 13.7 m Required pump NPSH 7.9 m
Shaft power P2 245.6 kW Speed 713 1/min
Pump efficiency 84 % P 2 * Pump efficiency
Total efficiency =
Power input P 1 259.2 kW P1

Item no.
Project: Created on: 3/05/2023
Project number: Created by:

Technical data with motor


Submersible sewage pump FA 60.83V FKT 63.1-10/56G

Tender text
Submersible Sewage Pump as submersible, single-stage block unit in stationary, vertical installation to pump untreated
sewage which doesn't attack the pump neither chemically nor mechanically. Pump with radially arranged discharge piece
and axial pump intake. Service-friendly design by separated motor and pump casing. Pumping values to be guaranteed as
per ISO 9906 Annex A
Project: Created on: 3/05/2023
Project number: Created by:

Performance curves with motor


Submersible sewage pump FA 60.83V FKT 63.1-10/56G

Power data referred to: Water (100%); 24 °C; 997.3 kg/m³; 0.9104582372 mm²/s
Tolerance as per ISO 9906 / Annex A.2

H/m Head - Ø 605 ∆p / MPa


0.25
25
0.24
24
0.23
23
0.22
22
0.21
21
0.2
20
0.19
19
0.18
18
0.17
17
0.16
16
Eff. 84.4% 0.15
15
0.14
14
13,7 A1 0,134
13 0.13

12 0.12

11 0.11

10 0.1

9 0.09

8 0.08
7 0.07
6 0.06
▕◄ Application range ► ▏
η84,05
/% Hydraulic efficiency

60

40

20

0
P₂ 245,6
/ kW Shaft power P2

220

200

180

160

NPSH / m NPSH-values

12
11
10
9

7,87 8
7

0 100 200 300 400 500 600 700 800 900 15391600 1700 1800 1900
1000 1100 1200 1300 1400 1500 Q / l/s

Pump Duty point data

Impeller Ø designed 605 mm Volume flow 1539.2 l/s


Nominal speed 700 1/min Head 13.7 m
Frequency 60 Hz Shaft power P2 245.6 kW
Impeller type Four-channel Pump efficiency 84 %
Motor Power input P1 259.2 kW
Rated power 260 kW Required pump NPSH 7.9 m
Sel. explosion protection Speed 713 1/min
Project: Created on: 3/05/2023
Project number: Created by:

Technical data with motor


Submersible sewage pump FA 60.83V FKT 63.1-10/56G

w
d
a

t
b

s
i
c
r

p
m
y
q
f
e

z
n
j
v

g
x
h

Dimensions in mm Connections
c 1550 v ø26 Suction port
d 400 w 2111
DN700
i 500 x 140
PN10
j 300 y 1060
m 1580 z 800 Discharge port
n 1320 e 1652
DN600
p 700 f 944
PN10
q 1136 g 1150
r 650 h 1982 Suspension device
s 1000 DN600/2RK
t 616