Data sheet

Customer item no.:10.3.3.1_A2


Communication dated: 01/08/2017 Number: 4003143265
Doc. no.: WWTP Sidi Bouzid Item no.: 2000
Quantity: 6 Date: 07/08/2017
Page: 1 / 5

Amamix C 4135/48 UDG Version no.: 2

Medium
Pumped medium Sludge Dry substance content [DS] 1.00 %
Activated sludge (agitator) Loss on ignition 70.00 %
Not containing chemical and Sludge volume index (SVI) 80.00 ml/g
mechanical substances which Viscosity 1.00 mPa s
affect the materials Share rate 189.00 1/s
Density 1000 kg/m³
Operating temperature 20.0 °C

Tank
Liquid volume 6057.78 m³ Basin radius R 8.00 m
Material Concrete Bend radius RB 4.00 m
Tank shape Oval race track with flow Eccentricity 0.00 m
deflectors (N) Average flow path 122.13 m
Fill level 6.20 m Number of mixers 6
Tank depth 7.10 m Energy density 4.23 W/m³
Channel width 8.00 m
Basin length 64.50 m

Aeration
Type Disc aerator Selection air input 2480.00 Nm³/h
Number of aeration fields 2 Aerated area
Alternating mixing No Distance betw. aeration fields 60.00 m
Max. air input 3100.00 Nm³/h

Creation of flow
Average flow velocity required 0.300 m/s The average flow velocity can only be achieved if inflows are
Calculated minimum average 0.300 m/s oriented in flow direction.
flow velocity

Design
Max. temperature 40.0 °C Manufacturer KSB
weight 91 kg Type (propeller side) MG
Type Amamix C 4135 / 4 8 Material code (propeller side) SIC/SIC/FPM
Execution of drive direct Mixer standard KSB-Aggregate international
Number of blades 3 execution
Propeller diameter 410.0 mm
Propeller speed 700 rpm Ex protection No
Absorbed power P1 at 4.27 kW Norm Without
operating point based on pure Temperature classes without
water aggregate
Shaft seal 2 mech. seals in tandem additional leakage control Without
arrangement with oil reservoir Weight 91
Sealing plan T Tandem mechanical seal
Data sheet

Customer item no.:10.3.3.1_A2


Communication dated: 01/08/2017 Number: 4003143265
Doc. no.: WWTP Sidi Bouzid Item no.: 2000
Quantity: 6 Date: 07/08/2017
Page: 2 / 5

Amamix C 4135/48 UDG Version no.: 2

Motor
FI operation permitted Yes (acc. motor Winding 400 / 690 V
manufacturer) Poles 8
Driver type Electric motor Starting mode Direct/Star-delta possible
Motor manufacturer KSB Starting mode
Motor generation D Connection mode Delta
Motor supplied by Standard motor supplied by Cooling method Surface cooling
KSB - mounted by KSB Motor version U
Rated voltage 400 V Operation with Frequency No
Frequency 50 Hz Inverter.
Motor speed 700 rpm Cable design Rubber hose
Rated power 4.00 kW Cable entry Sealed along entire length
Rated current 10.5 A Sales description power cable S1BN8-F 12G1.5
Starting current ratio 2.9 Number of power cables 1
Insulation class F to IEC 34-1 Motor moisture sensor 1
Type of protection Without Cable length 10.00 m
Motor enclosure IP68 Number of additional cable 0
Temperature classes without support including catch hook
Temperature sensor PTC resistor

Material variant
Axial propeller (ECB) Stainless steel 1.4571 Motor housing Grey cast iron EN-GJL-250
Gear casing Shaft Stainless steel 1.4571
Jet pipe Without Studs A4
Gasket FKM 80

Nameplates
Nameplates language International Duplicate nameplate With

Installation parts
Scope of supply Mixer with installation parts Holder for square guide rail Yes
Type of Installation Universal Instalation Claw material Grey cast iron EN-GJL-250
(Accessories 22) Bracket Yes
considered mounting depth 6.60 m Additional fastening set Adjustable (universal)
(guide tube length) lower holder level tank floor
Material guide tube Stainless steel 1.4301 Number of center supports 0
Guide tube 1 100 x 100 x 5 Adapter for tilt adjustment Without
Quantity 1
Length 6.00 m
Note for operation The guide rails must be
welded together and cut to
length on site.
Data sheet

Customer item no.:10.3.3.1_A2


Communication dated: 01/08/2017 Number: 4003143265
Doc. no.: WWTP Sidi Bouzid Item no.: 2000
Quantity: 6 Date: 07/08/2017
Page: 3 / 5

Amamix C 4135/48 UDG Version no.: 2

Please note
KSB quotations and the selection of mixers are exclusively Possible unexpected on-site conditions may result in the
based on the operating parameters specified above as well as reduction of the average flow velocity. In addition, tolerances in
the relevant physical variables. Consequently, KSB only the average flow velocity may occur when conforming with the
accepts warranty obligations for the mixing equipment to the mixer-relevant standards and directives.
extent of the data provided. It is therefore important that the
Please observe that velocities higher than the average flow
customer verifies whether the system data considered by KSB
velocity may be present locally.
in the mixer data sheet does, in fact, conform with the data of
the application, and that KSB is informed of any deviations. As The average flow velocity calculated by KSB considers the loss
the overall function substantially depends on the correct coefficients of a standardised aeration system situated near
positioning of the mixing equipment, KSB does not accept any the bottom of the tank. Consequently, it is important to verify
warranty claims resulting from a mixer positioning which has the calculation of the average flow velocity using the loss
not explicitly been approved of by us. Neither low-flow areas coefficients of the aeration system actually put into use.
(flow separation) resulting from the tank geometry nor the
hydraulic solids transportation of the overall system are subject The required flow velocity for a sediment-free operation is
to the KSB warranty. Furthermore, the utilisation of KSB mixers determined by the operational quality of the systems upstream
in protected procedures, and any resultant infringement of the of the tank, essentially by the quantity of solids reaching the
industrial property rights of third parties, are similarly excluded. tank. Activated sludge flocs settle at flow velocities < 10 cm/s
or in case of lack of local turbulence.
Without addition of polymeric flocculation aid.
Installation plan

Customer item no.:10.3.3.1_A2


Communication dated: 01/08/2017 Number: 4003143265
Doc. no.: WWTP Sidi Bouzid Item no.:2000
Quantity: 6 Date: 07/08/2017
Page: 4 / 5

Amamix C 4135/48 UDG Version no.: 2

Square guide tube Number of blades


275
3
142

420

192
180
234 687
410
Minimum dimensions of installation opening
772

321
42 5
106 100

460

43
100

844

1050

Dimension sheet Amamix G neutral


(without jet pipe)

Drawing is not to scale Dimensions in mm


Installation plan

Customer item no.:10.3.3.1_A2


Communication dated: 01/08/2017 Number: 4003143265
Doc. no.: WWTP Sidi Bouzid Item no.:2000
Quantity: 6 Date: 07/08/2017
Page: 5 / 5

Amamix C 4135/48 UDG Version no.: 2

844 360

min 160 772 240

687
120

321 275
50

280
100
42 426

142
420

410
192
180 Ha 410
150
min 230 150
10
150 65

200 150 min 160


Can be swivelled round guide tube axis by 45° right and left
200
in steps of 7.5°
234
44
Square guide tube
(not always included in KSB's scope of supply)

Minimum dimensions of installation opening

Installation example: wall-mounted with level tank floor


(Lifting bail optional)
460

1050

Drawing is not to scale Dimensions in mm

Universal Instalation (Accessories 22)