Professional Documents
Culture Documents
Operating data
Requested flow rate 750.00 US GPM Actual flow rate 750.05 US GPM
Requested developed head 100.00 m Actual developed head 100.01 m
Pumped medium Water Efficiency 78.9 %
Clean water Power absorbed 58.74 kW
Not containing chemical and Pump speed of rotation 2960 rpm
mechanical substances which NPSH required 8.14 m
affect the materials NPSH 3% 6.10 m
Ambient air temperature 20.0 °C Discharge press. 9.79 bar.g
Fluid temperature 20.0 °C
Fluid density 998 kg/m³
Design
Pump standard KSB axially split volute casing Minimum impeller diameter 215.0 mm
pump Full impeller diameter 275.0 mm
The performance of a pump is influenced by certain Free passage size 13.0 mm
manufacturing aspects and the quality of the materials used. Direction of rotation from drive Clockwise
(Surface roughness of castings, casting tolerances ...). With the Bearing seal driver side Lip seal
"Enhanced Finish" measures beyond the standard are carried Bearing type driver side Anti-friction bearings
out to improve the pump efficiency.. Lubrication type driver side Grease
Design Pump and motor on common Bearing sealing end side Lip seal
Baseframe (3E) Bearing type end side Anti-friction bearings
Orientation Horizontal Bearing lubrication end side Grease
Enhanced Finish Yes Temperature measurement With
Suction flange (AS) ASME B 16.1 / NPS 5 / CL tapping
drilling+seal face according to 125 / FF Temperature sensor PT100 Without
Discharge flange (AD) ASME B 16.1 / NPS 3 / CL motor side
drilling+seal face according to 125 / FF Vibration measurement With
Shaft seal Gland packing tapping
Manufacturer KSB Color Ultramarine blue (RAL 5002)
Type RT-P KSB-blue
Sealing plan PE Gland packing (external
circulation)
Wear ring Casing wear ring
Wear ring type Standard design
Impeller diameter 274.0 mm
Data sheet
Materials GB
Notes Bearing housing (350.1) HT250
Ammonium (NH4+) <= 2 mg/kg, free of H2S; Chlorine (Cl2) Shaft seal housing (441) HT250
<=0.6 mg/kg. Neck ring (457.2) ZCuSn10Zn2
general criteria for a water analysis: pH-value >= 7; chloride Casing wear ring (502) ZCuSn5Pb5Zn5
content (Cl) <=250 mg/kg. chlorine (Cl2) <=0.6 mg/kg. Shaft protecting sleeve (524.1) 14Cr17Ni2
Volute casing (102) HT250
Pump shaft (211) 20Cr13
Double-entry impeller (234) ZCuSn10Zn2
Performance curve
120 Qmin
Qmin
100
Total developed head
80
Qmin ø275.0/A01
ø274.0/A01
[m]
60
40 ø215.0/A01
40 NPSHR
NPSH 3%
[m]
NPSH req.
20
0
0 200 [US GPM] 400 600 800 1000 1200
Efficiency
50
[%]
0
0 200 [US GPM ] 400 600 800 1000 1200
90
[kW]
Power Input
50
10
0 200 [US GPM] 400 600 800 1000 1200
Flow
Curve data
Speed of rotation 2960 rpm Efficiency 78.9 %
Fluid density 998 kg/m³ Power absorbed 58.74 kW
Viscosity 1.00 mm²/s NPSH required 8.14 m
Flow rate 750.00 US GPM NPSH req. 3% 6.10 m
Requested flow rate 750.00 US GPM Curve number K42772
Total developed head 100.00 m Effective impeller diameter 274.0 mm
Requested developed head 100.00 m Acceptance standard tolerances to ISO 9906
class 2B
Installation plan
190
29 19 34
300 415
80
190
35
140
279
210
80 125 315
19 20 270
70
170 170
320
205 205
Connections
Suction flange (AS) ASME B 16.1 / NPS 5 / CL
drilling+seal face according to 125 / FF
Discharge flange (AD) ASME B 16.1 / NPS 3 / CL
drilling+seal face according to 125 / FF
Weight net
Pump 195 kg
Total 195 kg
Connect pipes without stress or strain! For auxiliary connections see
Notes for dimensions: separate drawing.
Drawing is not to scale.
Dimensions without tolerance indication: ISO 2768 CK
Dimensions without tolerance indication - shaft height: DIN 747
Dimensions without tolerance indication - welded parts: ISO 13920 - B/F
Dimensions without tolerance indication - Cast parts: ISO 8062-3 - DCTG 13
Dimensions without tolerance indication - Flange position: ISO 8062-3 - DCTG 13
Dimensions without tolerance indication - Flanges: acc. to flange standard
Dimensions without tolerance indication - Keyway and key at coupling: DIN6885 -
sheet 1
Dimensions without tolerance indication - Shaft diameter at coupling: DIN 7155 - h6
General notes:
Piping must be connected free of stress. The pump must not be used as
Installation plan
support for the piping (The pump is not an anchor point for the piping). The
piping must be fixed in such a way that no forces, vibrations or the weight of
the piping is transferred to the pump. Restrictions for forces and moments on
suction and pressure nozzle must be considered. Connection by means of
unrestrained expansion joints is not permitted!!
Grout all holes for the foundation blocks completely with nonshrinking
concrete. Observe the required compressive strength class C25/30 of the
concrete in exposure class XC1 as per EN 206-1.
Connection plan
Connections
1M.1 Pressure gauge connection G 1/2 Drilled and plugged.
1M.2 Pressure gauge connection G 1/2 Drilled and plugged.
4M.1 Temperature gauge connection G 3/8 Drilled and plugged.
(driven end)
4M.2 Temperature gauge connection (non G 3/8 Drilled and plugged.
driven end)
6B.2 Pumped liquid drain G 1/2 Drilled and plugged.
6D Pumped medium - filling / venting G 1/2 Flexible pipe with four way connector
and vent plugged
8A Leakage drain G 3/4 Drilled and plugged.
26M.1 SPM sensor connection (driver side) M8 Drilled and plugged.
26M.2 SPM sensor connection (non-driver M8 Drilled and plugged.
side)