Professional Documents
Culture Documents
Operating data
Requested flow rate 90.00 m³/h Actual flow rate 90.04 m³/h
Requested developed head 11.00 m Actual developed head 11.01 m
Pumped medium Water Efficiency 83.8 %
Clean water MEI (Minimum Efficiency ≥0.70
Not containing chemical and Index)
mechanical substances which Power absorbed 3.22 kW
affect the materials Pump speed of rotation 1462 rpm
Ambient air temperature 20.0 °C NPSH required 1.61 m
Fluid temperature 20.0 °C Permissible operating 16.00 bar.g
Fluid density 998 kg/m³ pressure
Design
Pump standard EN 733 Material code Q1Q1X4GG
Pump without drive group accessories Shaft seal code 10
Design Baseplate mounted, long- Sealing plan A Single-acting mechanical
coupled seal (A-type casing cover,
Orientation Horizontal taper bore)
Suction nominal dia. DN 100 Seal chamber design Conical seal chamber (A-type
Suction nominal pressure PN 16 cover)
Suction position axial Contact guard With
Suction flange dimension EN1092-2 Wear ring Casing wear ring
according to standard Impeller diameter 195.0 mm
Suction flange drilled EN1092-2 Free passage size 15.2 mm
according to standard Direction of rotation from Clockwise
Discharge nominal dia. DN 80 drive
Discharge norminal pressure PN 16 Silicon free pump assembly Yes
Discharge position top (0°/360°) Bearing bracket construction Water standard standard
Discharge flange dimension EN1092-2 Bearing bracket size 35
according to standard. Bearing seal V ring
Discharge flange drilled EN1092-2 Bearing type Anti-friction bearings
according to standard Lubrication type Grease
Shaft seal Single acting mechanical seal Color Ultramarine blue (RAL 5002)
Manufacturer KSB KSB-blue
Type 1
Driver, accessories
Driver type Electric motor Frequency 50 Hz
Drive standard mech. IEC Rated power P2 4.00 kW
Drive supplied by without motor Available reserve 24.25 %
Motor const. type B3 Number of poles 4
Motor size 112M
Data sheet
Materials G
Casing wear ring (502.1) Grey cast iron GG/CAST
Notes 1 IRON
General criteria for a water analysis: pH-value >= 7; chloride Casing wear ring (502.2) Grey cast iron GG/CAST
content (Cl) <=250 mg/kg. Chlorine (Cl2) <=0.6 mg/kg. IRON
Volute casing (102) Grey cast iron EN-GJL- Shaft sleeve (523) CrNiMo steel
250/A48CL35B Shaft protecting sleeve (524) Without
Casing cover (161) Grey cast iron EN-GJL- Stud (902) Steel 8.8
250/A48CL35B Screwed plug (903) Steel ST
Shaft (210) Tempered steel C45+N Nut (920.01) 8+A2A/ 8+B633 SC1 TP3
Impeller (230) Grey cast iron EN-GJL- Nut (920.95) Steel 8
250/A48CL35B
Bearing bracket (330) Grey cast iron EN-GJL-
250/A48CL35B
Flat gasket (400) DPAF seal plate asbestos
free
Data sheet
PumpMeter in an intelligent pressure transmitter with on-site Two gauge pressure transmitters, one each factory provided
display of measurement values and operating data of the on both, inlet and discharge side of pump. Connected to
pump. It comes factory-provided completely assembled and display unit via connector.
parameterised for your individual pump, to be connected via
M12 connector and immediately ready to operate. PumpMeter Accuracy of measurement (sum of errors; relating to
records the pumps load profile during operation in order to –if measurement range):
applicable –provide information on the potential for energy
savings or increased availability. ±1% for fluid temperature -10 … 100 °C
On-site display unit: ±2.5% for fluid temperature -30 … -10 °C and 100 … 140 °C
Backlit display unit for on-site display of measurement values Material of measuring cell: stainless steel (no internal gasket)
and operating data of pump with intuitive and internationally
comprehensible icons, rotatable in steps of 90 °. Available measurement ranges:
suction pressure, pressure at inlet of pump in bar, gauge -1 ...3 bar (gauge pressure)
pressure
discharge pressure, pressure at outlet of pump in bar, gauge
pressure Ambient conditions:
differential pressure between in- and outlet of pump in bar
qualitative indication of operating point Type of protection: IP 65
Connection of display unit via connector (M12 x 1, 5-pin for Ambient temperature:
power supply and utilization of communication interface. -30°C … 80°C (during transport, storage)
Making alternatively available: -10°C … 60°C (operation)
measurement value of discharge pressure via analogue signal
4 … 20 mA Fluid temperature: -30°C … 140°C
calculated value of differential pressure via analogue signal 4
… 20 mA Scuff resistance:
all display values via serial interface RS 485 (Modbus RTU). Ultraviolet resistance (outdoor installation)
Service interface RS232 for parameterisation. Resistance to most cleaning agents
Factory provided parameterisation for individual pump. Resistance to oil mist
Silicone free:
No detrimental to paint adhesion
Electric data:
Power supply:
24V DC ± 10%, min. 140 mA
Interfaces, alternatively utilisable:
4 … 20 mA, 3-conductor (discharge pressure or differential
pressure)
RS485, Modbus RTU (Slave)
Service interface: RS232
EMC:
EN 61326 (Immunity: industrial environment, Emissions:
applicable in home and building environment)
Performance curve
Qmin
15
Qmin
Total developed head
[m]
Qmin ø219.0/A01
10
Qmax
ø195.0/A01
ø165.0/A01
5
0 20 [m³/h] 40 60 80 100 120 140
2.0
[m]
NPSH req.
1.5
50
[%]
0
0 20 [m³/h] 40 60 80 100 120 140
4
[kW]
Power Input
Curve data
Speed of rotation 1462 rpm Efficiency 83.8 %
Fluid density 998 kg/m³ MEI (Minimum Efficiency ≥0.70
Viscosity 1.00 mm²/s Index)
Flow rate 90.04 m³/h Power absorbed 3.22 kW
Requested flow rate 90.00 m³/h NPSH required 1.61 m
Total developed head 11.01 m Curve number K1311.454/41
Requested developed head 11.00 m Effective impeller diameter 195.0 mm
Installation plan
250
DN1
180 18
4
22
65 110
345 32
280 95 14
215 160
10
35
19 48
125
Motor Connections
Not in scope of supply Suction nominal size DN1 DN 100 / EN1092-2
Motor size 112M Discharge nominal size DN2 DN 80 / EN1092-2
Motor power 4.00 kW Nominal pressure suct. PN 16
Number of poles 4 Rated pressure disch. PN 16
Speed of rotation 1462 rpm
Weight net
Pump 70 kg
Total 70 kg
Connect pipes without stress or strain! For auxiliary connections see
separate drawing.
Connection plan
Connections
Pump casing variant XX38
6B Pumped liquid drain Rc 3/8 Drilled and plugged.
6D Pumped medium - filling Rc 3/8 Drilled and plugged.
/ venting
8B Leakage drain G 1/2 Drilled
1M.1 / 6D Pressure gauge or Rc 3/8 Pressure sensor for PumpMeter fitted
filling/venting connection
1M.2 Pressure gauge Rc 3/8 Pressure sensor for PumpMeter fitted
connection