Page 1 of 1

MIXING SELECTION REPORT


Quote Number: 3503_2-211108-001 (Rev. 0)
Project:
Position: 1. Mixer - V = 1000 l

INPUT DATA TANK DIMENSIONS


Wastewater Treatment > Biological Treatment Mixing Circular / Standard
Biological Treatment Anox or Anaerobe or Deox - No Aeration [A] Diameter 14 m
Type of pre-treatment Screen <= ½ inch, primary sedimentation [C] Depth 7.5 m
Outlet location in tank Top
Recommended average velocity 0.25 m/s
Accept recommended avg. velocity Yes

PRODUCT DATA
Mixer type 4630 with Jetring
Number of mixers 2
Thrust produced/mixer 418 N
Total thrust produced 835 N
Total thrust required 753 N
MOTOR DATA
Power uptake / mixer 1.61 kW (19 % margin to input power)
Rated Shaft Power 1.5 kW
Total power uptake 3.22 kW
Mains frequency 50 Hz
Propeller diameter 368 mm
Number Of Phases 3
Propeller speed 710 RPM
Rated voltage 400 V Y
Number of blades 3
Number Of Poles 8
Rec. min Submergence 0.7m
Max Input Power 2 kW
Hub design 2
Approval STD
Propeller material Stainless steel
Rated Temperature 40 °C / 104 °F
Propeller code 083710SJ

ISO 21630 VALUES


Nominal thrust 430 N
ISO Input Power 1.61 kW
Efficiency 267 N/kW

Mixer performance data are based on the configuration 400 V Y for 50 Hz and 460 V Y for 60 Hz, for other configurations the data may be different. For mixer performance tolerances, refer to the
mixer data chart. Xylem guarantees that the proposed mixer selection will perform the specified duty when all mixers are operating positioned according to Xylem's recommendation. The selection
is a function of the input data and the supplier of the data is fully responsible for its correctness.