You are on page 1of 5

MODEL

FFI12HBX

ENGINEERING CODE COOLING CAPACITY

513200003 343 W (LBP)

APPROVED REFRIGERANT EFFICIENCY

R-134a 1.14 W/W (LBP)

POWER SUPPLY MOTOR TYPE

115-127 V 60 Hz CSIR

STANDARD CONDITIONS STARTING TORQUE


APPROVALS ASHRAE HST

APPLICATION

L/M/HBP

DATA

General Data
Type Hermetic reciprocating

Technology Type On-Off

Displacement 11.14 cm³

Compressor Cooling Fan/NotControled/115

Expansion Device Capillary Tube or Expansion Valve

Horse Power 1/3 hp

Power Supply 115-127 V 60 Hz

Evaporating Temperature Range -35 °C to 10 °C

Electrical Data
Motor type CSIR

Starting Torque HST

Start Winding Resistance 3.87 at 25° C

Run Winding Resistance 1.04 at 25° C

Mechanical Data
Oil Charge 280 ml

Oil Type Configuration ESTER

Oil Type Viscosity ISO22

Weight 10.7 Kg
Electrical Components
Description

Starting Device Relay | 213516051*

Motor Protection MRT22AFZ-5590 MRT22AFZ-5598

Start Capacitor 233-280 378-454 Uf / 150 V

External Characteristics
Tray Holder No

Connector Internal Diameter Shape

Suction 8.2 mm Straight/Copper

Discharge 6.5 mm Straight/Copper

Process 6.5 mm Straight/Copper

PERFORMANCE

Rated Points
Condensing Evaporating Cooling Power Gas Flow
Current Efficiency
Temperature Temperature Capacity Consumption Rate

54.40°C -23.30°C 343 W 300 W 4.97 A 6.66 kg/h 1.14 W/W

Test Condition: ASHRAELBP32, Fan/NotControled/115, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN

12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.


Performance Curve Data

Condensing Temperature 35°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-35 137 218 4.69 2.70 0.63

-30 207 256 4.78 4.09 0.81

-25 299 291 4.9 5.88 1.03

-20 415 324 5.03 8.14 1.28

-15 557 355 5.2 10.91 1.57

-10 726 387 5.4 14.26 1.88

-5 926 418 5.63 18.25 2.22

0 1157 449 5.89 22.93 2.58

5 1423 482 6.19 28.36 2.95

10 1724 518 6.54 34.59 3.33

Test Condition: ASHRAELBP32, Fan/NotControled/115, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Condensing Temperature 45°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-35 166 191 4.71 3.21 0.87

-30 236 234 4.79 4.58 1.01

-25 327 277 4.91 6.36 1.18

-20 442 318 5.06 8.59 1.39

-15 582 360 5.24 11.32 1.62

-10 749 402 5.47 14.63 1.86

-5 946 445 5.73 18.56 2.12

0 1174 491 6.04 23.18 2.39

5 1436 539 6.4 28.53 2.66

10 1733 591 6.8 34.68 2.93

Test Condition: ASHRAELBP32, Fan/NotControled/115, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.
Condensing Temperature 55°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-35 146 193 4.7 2.81 0.75

-30 215 239 4.79 4.18 0.9

-25 305 285 4.92 5.93 1.07

-20 418 332 5.09 8.13 1.26

-15 556 380 5.3 10.83 1.46

-10 721 429 5.56 14.08 1.68

-5 915 482 5.87 17.96 1.9

0 1140 537 6.23 22.50 2.12

5 1398 597 6.65 27.78 2.34

10 1691 661 7.12 33.84 2.56

Test Condition: ASHRAELBP32, Fan/NotControled/115, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Operating Envelope
External Dimensions

www.embraco.com
Wed, 21 Apr 21 17:46:40 +0000 GMT