MODEL

NT6215Z

ENGINEERING CODE COOLING CAPACITY

211AD06 1879 W (HBP)

APPROVED REFRIGERANT EFFICIENCY

R-134a 2.26 W/W (HBP)

POWER SUPPLY MOTOR TYPE

208-230 V 60 Hz CSIR

STANDARD CONDITIONS STARTING TORQUE


APPROVALS ASHRAE HST

APPLICATION

HBP

DATA

General Data
Type Hermetic reciprocating

Technology Type On-Off

Displacement 17.39 cm³

Compressor Cooling Fan/NotControled/208

Fan Air Flow 520 m³/h

Expansion Device Capillary Tube or Expansion Valve

Horse Power 1/2 hp

Max Condensing Pressure Operating 13.92 bar

Max Condensing Pressure Peak 15.62 bar

Power Supply 208-230 V 60 Hz

Evaporating Temperature Range -15 °C to 10 °C

Electrical Data
Motor type CSIR

Starting Torque HST

Start Winding Resistance 7.55 at 25° C

Run Winding Resistance 2.52 at 25° C


Mechanical Data
Maximum Recommended Refrigerant Charge 800 g

Oil Charge 450 ml

Oil Type Configuration ESTER

Oil Type Viscosity ISO22

Pressurization Dry air charge

Weight 17 Kg

Free Internal Volume 3.3 L

Electrical Components
  Description

Start Capacitor 64-77 Uf / 330 V

Starting Device Relay | MTRPH-0048-08*

Motor Protection MST22AKK-3265

External Characteristics
Base Plate Universal

Tray Holder No

Height 207 mm

Connector Internal Diameter Shape

Suction 9.6 mm Slanted 42?/Copper

Discharge 6.42 mm Straight/Copper

Process 6.42 mm Vertical/Copper

PERFORMANCE

Rated Points
Condensing Evaporating Cooling Power Gas Flow
Current Efficiency
Temperature Temperature Capacity Consumption Rate

54.40°C 7.20°C 1879 W 833 W 4.92 A 41.61 kg/h 2.26 W/W

Test Condition: ASHRAEHBP46, Fan/NotControled/208, Return Gas 35°C, Evaporation 7.20°C, Condensing 54.40°C, Ambient 35°C , Liquid 46.1°C, Subcooling 8.3K. Data in accordance to EN

12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.


Performance Curve Data

Condensing Temperature 35°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-15 931 454 3.39 17.17 2.05

-10 1183 500 3.56 21.90 2.37

-5 1486 549 3.74 27.62 2.71

0 1839 600 3.95 34.33 3.07

5 2241 654 4.17 42.07 3.43

10 2691 710 4.42 50.83 3.79

Test Condition: ASHRAEHBP46, Fan/NotControled/208, Return Gas 35°C, Ambient 35°C , Subcooling 8.3K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Condensing Temperature 45°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-15 826 481 3.5 16.46 1.72

-10 1044 540 3.72 20.88 1.93

-5 1310 601 3.95 26.31 2.18

0 1622 666 4.21 32.74 2.44

5 1980 732 4.48 40.20 2.7

10 2382 801 4.77 48.70 2.97

Test Condition: ASHRAEHBP46, Fan/NotControled/208, Return Gas 35°C, Ambient 35°C , Subcooling 8.3K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Condensing Temperature 55°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity W Rate kg/h W/W

-10 909 589 3.89 19.83 1.54

-5 1135 658 4.17 24.87 1.73

0 1404 729 4.47 30.94 1.93

5 1715 803 4.79 38.04 2.14

10 2068 879 5.13 46.20 2.35

Test Condition: ASHRAEHBP46, Fan/NotControled/208, Return Gas 35°C, Ambient 35°C , Subcooling 8.3K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.