MODEL

EMI45HER

ENGINEERING CODE COOLING CAPACITY

513303386 110 Kcal/h (LBP)

APPROVED REFRIGERANT EFFICIENCY

R-134a 1.09 Kcal/Wh (LBP)

POWER SUPPLY MOTOR TYPE

115 V 60 Hz RSIR

STANDARD CONDITIONS STARTING TORQUE


ASHRAE LST
APPROVALS
APPLICATION

LBP

DATA

General Data
Type Hermetic reciprocating

Technology Type On-Off

Displacement 4.08 cm³

Compressor Cooling Static/NotControled/115

Expansion Device Capillary Tube

Horse Power 1/8 hp

Power Supply 115 V 60 Hz

Evaporating Temperature Range -35 °C to -10 °C

Electrical Data
Motor type RSIR

Starting Torque LST

Start Winding Resistance 13.35 at 25° C

Run Winding Resistance 5.65 at 25° C

Locked Rotor Amperage (LRA) 26.7 A

Rated Load Amperage (RLA) at 60 Hz 3A


Mechanical Data
Oil Charge 160 ml

Oil Type Configuration ESTER

Oil Type Viscosity ISO22

Weight 7.54 Kg

Electrical Components
  Description

Motor Protection 4TM743KFBYY-53

Starting Device Relay | 213514091

External Characteristics
Tray Holder Yes

Connector Internal Diameter Shape

Suction 6.5 mm Straight/Copper

Discharge 4.94 mm Slanted/Copper

Process 6.5 mm Straight/Copper

PERFORMANCE

Rated Points
Condensing Evaporating Cooling Power Gas Flow
Current Efficiency
Temperature Temperature Capacity Consumption Rate

54.40°C -23.30°C 110 Kcal/h 101 W 1.26 A 2.47 kg/h 1.09 Kcal/Wh

Test Condition: ASHRAELBP32, Static/NotControled/115, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN

12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.


Performance Curve Data

Condensing Temperature 35°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity Kcal/h Rate kg/h Kcal/Wh

-35 48 106 1.09 0.97 0.46

-30 73 117 1.15 1.52 0.63

-25 104 127 1.22 2.22 0.82

-20 141 138 1.28 3.06 1.01

-15 184 149 1.34 4.06 1.24

-10 235 159 1.41 5.21 1.48

Test Condition: ASHRAELBP32, Static/NotControled/115, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Condensing Temperature 45°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity Kcal/h Rate kg/h Kcal/Wh

-35 55 72 1.07 1.24 0.77

-30 79 83 1.14 1.79 0.95

-25 109 96 1.23 2.47 1.13

-20 146 110 1.32 3.29 1.32

-15 188 124 1.42 4.26 1.51

-10 236 138 1.52 5.37 1.7

Test Condition: ASHRAELBP32, Static/NotControled/115, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.

Condensing Temperature 55°C

Evaporating Cooling Gas Flow Efficiency


Power W Current A
Temperature °C Capacity Kcal/h Rate kg/h Kcal/Wh

-35 44 67 1.04 0.98 0.65

-30 68 80 1.12 1.52 0.84

-25 97 96 1.22 2.19 1.02

-20 132 112 1.34 2.99 1.19

-15 173 130 1.47 3.93 1.33

-10 220 148 1.61 5.01 1.49

Test Condition: ASHRAELBP32, Static/NotControled/115, Return Gas 32.2°C, Ambient 32.2°C , Liquid 32.2°C. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and

uncertainty guidance.