DRAFT COPY

AMCEN LAB SDN BHD (1070971-W)


No.18, Lorong Talang 9, 13600, Perai, Penang
Tel: 04-390 3862
Fax: 04-390 3062
MS ISO/IEC 17025 Email: enquiry@amcen.com.my
TESTING
SAMM NO. 730

CERTIFICATE OF ANALYSIS

FLEXTRONICS SHAH ALAM SDN BHD Certificate No : AMC/A1803/093


Plot D26, Jalan DBP/4, Sample Log Code : A1803/085
Kaw. Zon Perindustrian Bebas, Pelabuhan Tanjung Pelepas, Sample Received Date : 22-Mar-2018
81560 Gelang Patah Issuance Date : 30-Mar-2018
Johor
Tel : 07-5048888 Fax : 07-5048377

Attention :

Sample Description : Personal Chemical Exposure Monitoring


Sample Information : Location: FA Lab
Name: Muhd Rafiuddin
Sampling Date: 20/3/18(Day1)

AMCEN LAB SDN BHD


Sampling Media: Coconut Shell Charcoal 100/50mg
Analysis results :

Parameter Standard Method Unit Analysis Result


* Heptane NIOSH 1500 mg/unit ND(<0.005)
* Isopropyl Alcohol (IPA) NIOSH 1400 mg/unit 0.838
* Stoddard Solvent NIOSH 1550 mg/unit please refer to attachment
Toluene In-house method based on NIOSH Method mg/unit 0.024
1501:2003, US NIOSH Manual of Analytical
Methods, 4thEdition
Symbol '*' denotes parameter which is not included within the scope of accreditation
ND denotes not detected
Remark :

Chong Hooi Min


B.Sc. (Hon.) Chemistry
L-1722-5592-09

Page 1/2
This report is provided solely for informational purposes and is not to be construed as providing legal advice, recommendations or warranties of any kind whatsoever. This report shall not be
reproduced except in full, without written approval of the laboratory. The result expressed herein do not necessarily reflect the opinion or position of AMCEN LAB SDN. BHD.
DRAFT COPY
AMCEN LAB SDN BHD (1070971-W)
No.18, Lorong Talang 9, 13600, Perai, Penang
Tel: 04-390 3862
Fax: 04-390 3062
MS ISO/IEC 17025 Email: enquiry@amcen.com.my
TESTING
SAMM NO. 730

CERTIFICATE OF ANALYSIS

Certificate No : AMC/A1803/093

Sample Description: Personal Chemical Exposure Monitoring


Location: FA Lab Name: Muhd Rafiuddin Sampling Date: 20/3/18(Day1)

Objective:
Determine of Stoddard Solvent by Gas Chromatography with Mass Detection (GCMS).

Test Procedure:
Sample was extracted with 2 ml of carbon disulfide and injected to GCMS.

Results of Analysis:

AMCEN LAB SDN BHD


The results of analysis were tabulated in the table below and semi quantification was carried out using
hexadecane as standard.

Table 1: Compounds detected in Location: FA Lab Name: Muhd Rafiuddin Sampling Date: 20/3/18(Day1)
Retention Resultb,
Quala
time Compound mg/unit
1.391 Isopropanol 90 0.005
3.505 Toluene 91 0.003
Total 0.008

a
% of matching with NIST library based on mass spectrum of compound. . Match factors of greater than
90 is considered an excellent match, 80-90 a good and < 80 is considered poor. However, it depends on
compound, concentration, background noise and other factors.
b
Compounds were semi quantitated by hexadecane as standard

Page 2/2