You are on page 1of 1

Oil & Gas Engineering

Services

DETAILED DESIGN FOR BLACK POWDER FILTRATION UNIT FOR


GTP
SKID FOUNDATION CALCULATION NOTE
CONTRACTOR Document N°: COMPANY Document N°: Rev: 000
55367-OMV-CV-CA-001 NAWGTP-AEI-PF02-220-CV-CLN-00001 Page : 5 of 20

1. SCOPE

This document presents the check done for the black powder filter foundation stability and
the calculation for reinforcement.

2. CODES AND STANDARDS

The design codes used for this calculation are as follows:


 EN 1991-1-1 :2002 : Eurocode 1 : Actions on structures – Part 1-1 : General
Actions – Densities, self-weight, imposed loads for
buildings

 EN 1991-1-2 :2002 : Eurocode 1 : Actions on structures – Part 1-2 : General


Actions – Actions on structures exposed to fire

 EN 1991-1-3 :2003 : Eurocode 1 : Actions on structures – Part 1-3 : General


Actions – Snow Loads

 EN 1991-1-4 :2005 : Eurocode 1 : Actions on structures – Part 1-4 : General


Actions – Wind actions

 EN 1991-1-5 :2003 : Eurocode 1 : Actions on structures – Part 1-5 : General


Actions – Thermal actions

 EN 1991-1-6 :2005 : Eurocode 1 : Actions on structures – Part 1-6 : General


Actions – AAccidental actions

 EN 1991-3 :2006 : Eurocode 1 : Actions on structures – Part 3: General


Actions – Actions included by cranes and machinery

 EN 1991-4 :2006 : Eurocode 1 : Actions on structures – Part 4 : Silos and


tanks

ALPHA ENGINEERING Intl.


Sahloul III - 4054 Sousse – Tunisia
Code TVA : 950448R/A/M/000. R.C : B279902006
Tél : +216 73 821 245 / 246 / 247 Fax : +216 73 821 249
This document is the property of Alpha Engineering International who will safeguard its rights according to the civil and penal provisions of the Law.