You are on page 1of 24

a h igher level of pe rfo r ma nce

Measurement Systems

hawklevel.com
Measurement Systems

A WORLD LEADER IN LEVEL MEASUREMENT

Hawk Measurement Systems Pty Ltd (Hawk) was established


in 1988 following recognition
by directors of the potential
of ultrasonics in level and flow
applications.

Hawk continues to invest


heavily in research,
development and technical
knowledge to redefine customer performance expectations.

The company is located in Nunawading, Melbourne, Victoria,


Australia and operates from a purpose built factory and
office. The facility provides for efficient production and
research &
development activities.
The design and manu-
facturing company
produces it’s own
products and has
quality to international
abou t H aw k . . . standards and trace-
ability.

Hawk has a
distinguished
record of achievement
in the application of
Brown coal materials handling site
level measurement
technology. Through the provision of expert services which range
from instrumentation and technical assistance
through to successfull installation.

We provide extensive training for our


worldwide distributors on a progressive
basis so when new products are introduced,
training is carried out prior to release to
ensure optimum product acceptance and
performance. Hawk has on-going
commitment to providing industry with
workable solutions. Our success and
acceptance and reflections of our
Silos
commitment.

Hawk have targeted a rangeof industries, including all areas


of mining, aluminium smelting, alumina refining and
water/sewerage utilities and drawn on its reputation as an
innovator and problem solver to market products into what
has previously been very difficult applications.

A HIGHER LEVEL OF PERFORMANCE


LEVEL & FLOW SOLUTIONS

- ACOUSTIC WAVE SERIES


The SULTAN is a non intrusive acoustic wave transmitter with flexibility used for measuring liquids and solids.

• Remote, Integral & SMART units available.

Operation by 2 wire loop or seperate power supply can be selected by a simple change of SMART card position.

Principle of Operation

The SULTAN emits a high powered acoustic wave transmit pulse which is reflected from the surface of the
material being measured. The reflected signal is processed using specially developed software to enhance the
correct signal and reject false or spurious echoes.

The transmission of these high powered waves ensures minimal losses through the environment where the sen-
sor is located. Due to this high powered emitted pulse, any losses have a far less effect than traditional ultra-
sonic devices. More energy is transmitted hence more energy is returned. The receiver circuitry is designed to
indentify and monitor low level return signals even when noise levels are high.

The measured signal is temperature compensated to provide maximum accuracy to the outputs and display.

Features

• Remote 2 wire option


• Non contact measurement
• Low installation costs
• High Power
• Low cost per point
• Wide range of communications -
Hart, Goshawk, Modbus, Profibus & Foundation Fieldbus (pending)
• Hazardous area approvals
• Open channel flow algorithms
• Pump Control (x5 pumps)
• Auto compensation (dust, steam)
• Housing Dust/Environment sealed
• Enclosure rating IP67, NEMA 4x
• Programmable fail safe mode 2 / 234 SMART card configuration
• High Temp Applications 175ºC (347ºF)
• GSM/CDMA remote setup options/configurable
• Differential level control (2 transducers)
• Bin mapping for unwanted echo elimination
Hawk Measurement Systems Pty Ltd

SULTAN 2 Transmitter SULTAN 234Transmitter


LEVEL & FLOW SOLUTIONS

Primary areas of application

• Water/waste water
• Open channel flow
• Inlet screens
• Pump stations
• Water towers
• Dam level
• Chemical
• Mining
• Crushers
• Surge bins
• Ore passes
• Conveyor profile
• Blocked chute
• Stockpile
• Stackers
• Reclaimers
• Storage silos
• Power Stations
• Boiler bunkers
• Raw coal bunkers
• Ash pits
• Fly ash silos

Plus many other applications including food, cement,


plastics, grain, paper, irrigation, quarries etc.

Differential Level
SULTAN 234

Junction Box

Screen / Filter

In Flow
Out Flow
Hawk Measurement Systems Pty Ltd

SULTAN Integral


LEVEL & FLOW SOLUTIONS

Typical Applications

Storage Vessel Sewage Wet Well


Powders/Rock/Ore Up to 5 Pumps

SULTAN 234 5kHz transducer

SULTAN 234

Conical Shape Vessels


Hawk Measurement Systems Pty Ltd

SULTAN 234

Proven performance during filling & emptying


in silos up to 90m (295ft)


LEVEL & FLOW SOLUTIONS

- PANEL MOUNT / REMOTE


Choice of technologies using the same transmitter

Sultan Panel Mount

Pressure OR Acoustic Wave

Remote Transducer

Pressure Sensor

Sultan Panel Mount


Hawk Measurement Systems Pty Ltd

Pressure Sensor
Remote Transducer


LEVEL & FLOW SOLUTIONS

CRANEMASTER
Crane Anti-Collision
Maximum distance 170m (556ft)

POSITIONING
Machinery Positioning
Maximum distance 170m (556ft)
Hawk Measurement Systems Pty Ltd


LEVEL & FLOW SOLUTIONS

WATER AND SEWERAGE


Hawk Measurement Systems has long been involved in the water and wastewater industry. Some of the ap-
plications we are experienced in are open channel flow monitoring in aquaducts, level monitoring in reservoirs,
sludge blanket controls in both primary and secondary clarifiers as well as being one of the worlds largest sup-
plier of ultrasonics for sewerage wet well applications.

We have recently expanded our range to include point devices to monitor density and suspended solids.
Hawk, over the years has developed an excellent working relationship with the worlds largest water and waste-
water authorities. We have invested heavily in research and development to ensure we have the most state of
the art equipment available on the market today.

Level Transmitters (Non-Intrusive)


Low cost of Ownership
Replaces Intrusive Level Instruments that suffer from Ragging and Fats
Hawk Measurement Systems Pty Ltd


LEVEL & FLOW SOLUTIONS

- SONAR SLUDGE LEVEL SYSTEM


The ORCA series Sonar will measure up to two density interfaces simultaneously, either bed level or RAS blan-
ket and floc/fluff layer or clarity of water, using the new ORCA Sonar hardware.

Principle of Operation

The ORCA series Sonar transmits a sound pulse through the liquid towards the blanket/interface at the bottom
of the tank. The pulse is reflected off the blanket/interface back to the sonar transducer, which is interpreted by
the Orca transmitter, compensated for temperature and provides a distance reading to the blanket/interface or
height of blanket/interface from the bottom up. An analog output or comms based output tracks this blanket/
interface.

The ORCA series also provides a second independent output that can be programmed to track either the clarity
of the water (liquid) monitoring the change of suspended solids, or other stratified interfaces or, the fluff/floc
layer (where the interface moves independent of the RAS blanket/bed level and needs to be monitored to pre-
vent overflow into the launders).

The ORCA processing software monitors the operating efficiency of the sonar transducer. As the efficiency
drops off, due to build-up of scum, air bubbles, scaling etc. to the transducer diaphragm, the automatic clean-
ing mechanism will remove all scum and attached solids to restore the sonar transducers optimum efficiency.
Hawk Measurement Systems Pty Ltd

ORCA Sonar Transmitter

ORCA Sonar Transmitter with electric


actuator in freezing conditions

10
LEVEL & FLOW SOLUTIONS

Features

• Interface level monitoring


• Unique programming “density” of interface to be monitored
• Dual analog outputs from one sonar transducer to provide (bed level or RAS blanket) and (floc/fluff layer or
clarity of liquid)
• Widest industry range of sonar frequencies to optimise performance
• GSM/CDMA modem for remote technical and diagnostic support and commissioning

Primary areas of application

Area Functions
Water Treatment Plant
Primary Sedimentation Tank Floc level / sludge blanket level
Sludge Thickener Tank Sludge bed level / clarity suspended solids / floc level
Calcium Hydroxide Reactor Sand/pellet bed level
Sodium Hydroxide Reactor Sand/pellet bed level

Sewage Treatment Plant


Primary Sedimentation Tank Sludge blanket level
Secondary / Final Clarifier RAS blanket level / rag/pinfloc layer / clarity suspended solids
Sludge Thickener Tank Sludge bed level / clarity suspended solids
“DAF” Tank Sludge bed level / floating sludge level
Sequential Batch Reactor (sbr) Settling bed level / RAS blanket level

Industrial (food, paper etc)


Primary Sedimentation Tank Sludge blanket level
Secondary Clarifier Tank RAS blanket level / clarity suspended solids / rag/pinfloc layer
Thickener Tank Sludge bed level / clarity suspended solids / floc level
“DAF” Tank Sludge bed level / floating sludge level
Sequential Batch Reactor (sbr) Settling blanket level / RAS bed level
Carbon Column Carbon bed level

Mining/Mineral processing
Clarifier Tank Blanket level / clarity suspended solids / stratified floc layers
Thickener Tank Sludge bed level / clarity suspended solids / stratified floc layers
CCD’s Tank Sludge bed level / clarity suspended solids / stratified floc layers
Settling Ponds Sludge bed level
Hawk Measurement Systems Pty Ltd

ORCA Sonar auto cleaning mechanism

11
LEVEL & FLOW SOLUTIONS

The Hawk Liquid series emits a high powered acoustic


wave transmit pulse which is reflected from the surface
of the liquid to be measured.
The Liquid is a brand new product specific for liquid
level monitoring.

Features Benefits
Simple Menu Easy to start-up
Liquid Only Low Cost / High Quality
Proven Technology Install and Forget
Non Contacting Low Maintenance
Adaptive Gain Technology Works in the Tough Applications
• Condensation
• Vapors
• Foam
Hawk Measurement Systems Pty Ltd

Chemical Storage Tanks

12
LEVEL & FLOW SOLUTIONS

FLOW - OPEN CHANNEL


Real time flow measurement of liquid materials. Head, flow
rate and flow volume data can be transmitted.

Primary Areas of Application

• Open Channel Flow


• Special flow requirements for unusual flow channels
• Water treatment
• Sewage treatment
• Irrigation
• Industrial waste
• Power waste

Features
Remote Flow Unit
• Frequency optimisation to suit the application environment
• Automatic power and sensitivity control to suit conditions
• Wide range of signal conditioning options
• Capable of monitoring liquids under the most difficult
foaming conditions
• Wide range of tracking and recovery schedules (algorithm,
procedures etc)
• Manual echo selection for difficult applications
• Real time display of gain levels, power level, frequency and
signal to noise ration
• Flexible, multi point scaling of display / outputs
• Failsafe contact closure output
• Temperature compensation
• GSM/CDMA for remote connection
• Modbus outpout
• British flow standard BS 3680 Parshall Flume
• Australian flow standard AS 3778

V-Notch Rectangular Trapezoidal Rectangular Constricted


Sharp-Crested Weir Sharp-Crested Weir Sharp-Crested Weir Sharp-Crested Weir

Parshall Flumes Khafagi-Venturi Flumes Palmer-Bowles Flumes


Hawk Measurement Systems Pty Ltd

13
LEVEL & FLOW SOLUTIONS

MICROWAVE - BLOCKED CHUTE


Point level switching for presence or absence of most solid and liquid materials. Environmentally and personally
safe replacement for nucleonic switches. Not restricted by OSHA or FCC regulations. Caution sign posting not
required.

Principle of Operation

The Hawk Microwave Pulse Sender-Receiver Remote System is comprised of three electrically isolated units:- the
sender unit, three receiver units and amplifier unit. The Integral System is comprised of two electrically isolated
units - the send and the receiver unit. The Sender-Receiver units are mounted facing each other.

The sender emits a burst of microwave energy toward the receiver, which is designed around a tuned microwave
detector. This burst of energy is transmitted approximately 200 times each second. When the line-of-sight is
interrupted by a sufficienct reflective or absorbent material the energy will not reach the receiver, and therefore
the receiver will not detect the transmission.

The receiver is designed to switch a relay when it’s detector changes state. Time delays between detector
change and relay switching is set via two single turn potentiometers; there is a potentiometer for the make (sig-
nal detected) delay and another for the break (signal interrupted) delay. In each case the relay will switch only
after the detector state has been maintained (since it’s change) for the respective time: any further change of
state during a time-out period will override the previous change.

The sensitivity of the detector is adjusted by a potentiometer. By this adjustment, compensation can be made
for partially reflective or partially absorbing materials. Similarly, it can be adjusted so that it will change state
when only a fraction of the beam is blocked. There are two sensitivity adjustment potentiometers, one for a
coarse adjustment and the other for a fine adjustment.

The relay can be set to either energize or de-energize when the beam is broken.

A R
L E
U C ES
N CH
S
E IT
C
A SW
L
P LT
E
R TI
&
Hawk Measurement Systems Pty Ltd

Microwave Pulse Switch Remote version sender / receiver

14
LEVEL & FLOW SOLUTIONS

Typical Uses

• Flow / no flow
• Plugged chute detection
• Low level measurement
• High level measurement
• Product on conveyor detection
• Rail/truck load out position detection
• Anti-collision crane detection
• Blocked feeder pipes for pneumatic and
dense phase filling, air slides etc
• Replacement of tilt switches

Primary areas of application

Any application where microwave energy is absorbed by


the material being monitored, including replacement of tra-
ditional contact switching devices used in mining, sand and
gravel quarries, cement plants, pulp paper, plastic, rubber,
coal fired power plants, steel mills, aluminium smelters,
food, pharmaceuticals and other manufacturing fields
Hawk Measurement Systems Pty Ltd

Microwave Pulse Switch Integral version sender / receiver

15
LEVEL & FLOW SOLUTIONS

Typical Microwave Applications


Feeder pipe coal/ore • Flow/no flow • Blocked chute

Serial No. MXXXXXXX


Receiving unit
High Level
RECEIVE
SENSITIVITY MPR-0 4
MICROWAVE PULSE RECEIVER
1 10
RV1 LD1 - POWER
APPLIED ON
LD2 - SIGNAL DELAY
LO HI DETECTED 0.3 4 -30 sec
(A=B) LD3 - RELAY
ENERGISED RV2
AFTER DELAY 1 10
RV2 OFF
DELAY
LO HI 0.3 -30 sec
RELAY
NORM

REV
AC FUSE
P R S T U V W
N EUTRAL

100mA
A CTIVE

E ARTH
E ARTH

FROM TO
+24V

MPS MPS

Serial No. MXXXXXXX


Receiving unit Sending Unit
Low Level
RECEIVE
SENSITIVITY MPR-0 4
MICROWAVE PULSE RECEIVER
1 10
RV1 LD1 - POWER
APPLIED ON
LD2 - SIGNAL DELAY
LO HI DETECTED 0.3 4 -30 sec
(A=B) LD3 - RELAY
ENERGISED RV2
AFTER DELAY 1 10
RV2 OFF
DELAY
LO HI 0.3 -30 sec
RELAY
NORM

REV
AC FUSE
P R S T U V W
N EUTRAL

100mA
A CTIVE

E ARTH
E ARTH

FROM TO
+24V

MPS MPS

Blocked Chute Detector


Receiving unit

Serial No. MXXXXXXX

RECEIVE
SENSITIVITY MPR-0 4
MICROWAVE PULSE RECEIVER
1 10
RV1 LD1 - POWER
APPLIED ON
LD2 - SIGNAL DELAY
LO HI DETECTED 0.3 4 -30 sec
(A=B) LD3 - RELAY
ENERGISED RV2
AFTER DELAY 1 10
RV2 OFF
DELAY
LO HI 0.3 -30 sec
RELAY
NORM

REV
AC FUSE
P R S T U V W

N EUTRAL
100mA

A CTIVE

E ARTH
E ARTH
FROM TO

+24V
MPS MPS

Sending Unit

Solid Level - Cyclone Bin


High/Low Level

Receiving
unit

High
Serial No. MXXXXXXX

RECEIVE
SENSITIVITY MPR-0 4

Sending
MICROW AVE PULSERECEIVE
R
POWER 1 10
RV1 LD1 -
APPLIED ON
LD2 - SIGNAL DELAY
DETECTED 0.3 4 -30 sec
LO HI
(A=B) LD3 - RELAY
ENERGISED RV2
AFTER DEL
AY 1 10
RV2 OFF

Unit
DELAY
LO HI 0.3 -30 sec
RELAY
NORM

REV
AC FUSE
P R S T
N EUTRAL

100mA U V W
ACTIVE

E ARTH
E ARTH
+24V

FROM TO
MPS MPS
Hawk Measurement Systems Pty Ltd

Low
Receiving Serial No. MXXXXXXX

MPR-0
unit
RECEIVE
SENSITIVITY 4

Sending
MICROW AVE PULSERECEIVE
R
POWER 1 10
RV1 LD1 -
APPLIED ON
LD2 - SIGNAL DELAY
DETECTED 0.3 4 -30 sec
LO HI
(A=B) LD3 - RELAY
ENERGISED RV2
AFTER DEL
AY 1 10
OFF

Unit
RV2
DELAY
LO HI 0.3 -30 sec
RELAY
NORM

REV
AC FUSE
P R S T
N EUTRAL

100mA U V W
ACTIVE

E ARTH
E ARTH
+24V

FROM TO
MPS MPS

16
LEVEL & FLOW SOLUTIONS

MICROWAVE DOPPLER SWITCH


Flow/no flow detection in solid material handling applications such as feeder chutes and conveyor systems.

Principle of Operation

The Hawk MDS series Microwave doppler flow switch was developed for use in process applications requiring
highly reliable non-contact product flow detection. The system operates by sending out bursts of microwave
energy toward the target product being monitored. The target product will reflect some of the microwave en-
ergy back to the MDS system where it is processed to determine if the product is flowing. The MDS system uses
the Doppler principle to determine if the product is moving by monitoring small charges in the reflected signal
frequency.

Typical Uses

• Product detection on belt conveyor systems


• Product discharge detection on stackers
• Coal feeder monitoring - Power stations
• Grain feeder monitoring
• Aggregate feeder chute monitoring
• Conveyor/transfer chute monitoring
• Machine/conveyor motion detector

Coal Feeder
Product Movement/Flow Detection

Conveyor
Moving product on
Flow detection conveyors
Flowing solids /
powders Moving product
on conveyors
Conveyor MDS
Moving product
on conveyors
Hawk Measurement Systems Pty Ltd

Serial No. MXXXXXXX

RECEIVE
SENSITIVITY MPR-0 4
MICROWAVE PULSE RECEIVER
1 10
RV1 LD1 - POWER
APPLIED ON
LD2 - SIGNAL DELAY
DETECTED 0.3
LO HI 4 -30 sec
(A=B) LD3 - RELAY
ENERGISED RV2
AFTER DELAY 1 10
RV2 OFF
DELAY
LO HI 0.3 -30 sec
RELAY
NORM

REV
AC FUSE
P R S T 100mA U V W
N EUTRAL
ACTIVE

E ARTH
E ARTH

FROM TO
+24V

MPS MPS

17
LEVEL & FLOW SOLUTIONS

SMART SWITCH SERIES


VS1000
Vibration Switch Series

The piezo-electrically stimulated oscillating probe vibrates at its mechanical frequency of resonance. If the
probe is covered by bulk material, the damping thus generated is registered electronically and a corresponding
signal output is actuated. The oscillation of the device ensures that it features certain self cleaning properties
and can be used for liquids and solids product detection. PC Connectable.

Typical Uses

The device is used for level monitoring in all types of containers and silos. It can be used with all powdery and
granulated bulk materials that do not show a propensity to form crusts or deposits and are free flowing or can
be used on low viscosity liquids. A wide range of applications are found in foodstuff manufacturing.

Primary Areas of Application


• Building Industry - Materials, lime
styrofoam, moulding sand etc.
• Foodstuff Industry - Milk powder, flour, salt etc.
• Plastics Industry - Powder, granules etc
• Timber Industry, Chemical Industry, Mining etc.
Hawk Measurement Systems Pty Ltd

18
LEVEL & FLOW SOLUTIONS

SMART SWITCH SERIES


AS2000
Admittance Switch Series

Principle of Operation

The AS2000 Admittance switch monitors a change in current flow which is proportional to the admittance be-
tween the sensing probe, the product and the vessel wall. It features excellent temperature stability and switch
point repeatibility. It has the capability to neglect conductive and non conductive product build up on the probe.
PC Connectable.

Typical Uses TYPICAL APPLICATION


Flyash detection switch
• Failsafe high level / low level alarm
• Flyash Bins
• High level alarm
• Low level alarm
• Blocked chute / Plugged chute
• Point level for liquids, solids and powders.

Primary Areas of Application

• Aluminium Smelters • Flour Plants


• Asphalt Plants • Glass Plants
• Automotive Plants • Paint Plants
• Brewerys • Paper Plants
• Cement Plants • Pharmaceutical Plants
• Chemical Plants • Power Stations
• Coal Plants • Sewage Treatment Plants
• Coke Plants • Soft Drink Plants
• Fertilizer Plants • Steel Mills
• Food Plants • Water Treatment Plants

UP
L D
B UI
TO
N E
Hawk Measurement Systems Pty Ltd

U
M
IM

19
LEVEL & FLOW SOLUTIONS

SMART SWITCH SERIES


CS3000
Conductivity Liquid Switch Series
Non-metallic tank
Principle of Operation

The CS3000 Conductivity switch is used for level monitoring of


electrically conductive liquids, muds etc in all kinds of metallic
and non-metallic containers. In the case of a metallic tank the
conductivity between the front of the probe and the container
wall is measured. In the case of a non metallic tank the conduc-
tivity occurs between the two probes. PC Connectable.

Primary areas of application

• Sump pump control • Chemicals


• Liquids • Water Level

Metallic tank
Hawk Measurement Systems Pty Ltd

Integral 2 Probe version Integral Single probe version


Non metallic tank Metallic tank

20
LEVEL & FLOW SOLUTIONS

ROTATION RS4000 SERIES


RS4000
Rotation Switch Series

• High Reliability
• Dust Sealed

Principle of Operation

The RS4000 rotating vane is driven by a slow speed synchronous geared motor. The rotating vane projects into
a container. When the material to be monitored reaches the rotating vane, the rotating movement of the latter
is impeded. The synchronous motor is freely suspended at its driving axle. The resulting reaction torque is used
to operate a microswitch that delivers a corresponding electric output signal. The geared motor is stopped and
the switch contacts change over.

Typical Uses

For safe and multi-purpose level monitoring in all types of containers and silos. It can be used with all bulk
materials and powders.

Primary areas of application

• Building Industry - Materials, lime, styrofoam, moulding sand etc.


• Foodstuff Industry - Milk powder, flour, salt etc.
• Plastics Industry - Powder, granules etc.
• Timber Industry, Chemical Industry, Mining etc.

Typical Application

Mechanical
Protection
Hawk Measurement Systems Pty Ltd

Rotation RS4000

21
LEVEL & FLOW SOLUTIONS

MULTIDROP CONNECTIONS

Gladiator Gladiator
Admittance Admittance
Switch Switch

Gladiator
Gladiator
Admittance
Admittance
Switch
Switch
Sultan Acoustic Sultan Acoustic
Wave Transmitter Wave Transmitter
Slurries Floatation Cells

Gladiator
Microwave Microwave Vibration
Low Level Low Level Switch

Sultan Acoustic Wave Transmitter


Silo, bin levels, coal, plastic powder,
woodchip, sawdust, cement,
clinker, iron ore, lime etc. SULTAN 234

Gladiator
Conductivity
Switch Sultan Smart Transducer
Farm Tanks, Grain Terminals

Orca Sonar Interface. SULTAN 234

Thickener, CCD
Gladiator
Conductivity
Sultan Acoustic
Switch Wave Switch
Blocked Chute Detection

Orca Sonar Inteface Clarifier GSM Network


or
CDMA Network

Sultan Master/Slave Positioning System Sultan Acoustic Wave Transmitter


Stockpiles, Stackers,
Reclaimers

GSM or CDMA Network


• Typically up to 32 transmitters or switches per string.
Hawk Measurement Systems Pty Ltd

• Maximum 256 transmitters or switches.


• Using GSM/CDMA network, transmitters and switches can be Laptop or PC Communications
monitored, calibrated remotely. or PLC / DCS with
• Alarm status, diagnostics can be monitored. MODBUS RTU Port
• Support from factory engineering for customer application problems. Goshawk Software for
• Specifications for all other communication systems, eg HART, Profibus, Inventory monitoring on P.C.
Modbus etc check instruction manual. (Limited Modbus query rate for Switches only)
22
LEVEL & FLOW SOLUTIONS

ADVANCED REMOTE SUPPORT


Hawk has once again redefined industrial level control with its revolutionary GSM/CDMA communication device
HawkLink. This unit allows any computer with a standard modem and Goshawk software to dial in and calibrate,
test or check in on the performance of the Hawk product. Hawk understands it can be difficult or inconvenient
to have qualified service personel access a unit during the commissioning, so the solution is to dial in remotely.

Remote technical support via our GSM/CDMA module can monitor and adjust settings no matter what corner of
the world.

This system allows complete commissioning of equipment in applications to be done via GSM/CDMA
connectable sites worldwide.
Hawk Measurement Systems Pty Ltd

Remote connection worldwide!

23
Hawk Measurement Systems Hawk Measurement America

15-17 Maurice Crt 3911 W. Van Burren STE B-7


Nunawading VIC 3131 Phoenix, Arizona 85009
Australia USA

Phone: 61 3 9873 4750 PH: +1 888 HAWKLEVEL (1-888-429-5538)


Fax: 61 3 9873 4538 Fax: +1 602 353 1707

hawksales@hawk.com.au support@hawkmeasure.com

www.hawklevel.com www.hawkmeasure.com

Measurement Systems

Representatives Worldwide

Specifications subject to change without notice

Drawings & Diagrams are not to scale