You are on page 1of 2
INDEPENDENT Cilio LABORATORIES ALA: wall REPORT ON SHEAR STRENGTH OF THRU BOLT Page! of 1 cuent + MIS Al Hal & Al Muka For Geotechnical Works (LLC) REPORTNO. + ISTL1I0#20025 101 CONSULTANT MIS ASAS Group DATE REPORTED : 11/04/2020 ‘CONTRACTOR + MiS Stone Hertoge LC LAB REFERENCE NO. + STLM0#20025, PROJECT NAME + Mowhella +5 LAB PROJECTINO. : ISTLC-se5 PROIECT NO, NP LAB SAMLENO. + ISLt10820.025 PROJECT LOCATION Mowbeia SAMPLED BY + Customer SAMPLE DESCRIPTION +The Bolt SAMPLE BROUGHT IN BY + STL Rep. SOURCE OF SAMPLE : NP SAMPUNG DATE. 07/04/2020 SAMPLEIDENTIRCATION NO. + 10mm Bot DATE SAMPLERECEIVED : 07/04/2020 SAMPLE SIZE 2 Nos DATEOFTEST + 1/09/2020 SENDER REFERENCENO. =: NP AMBIENT TEMPERATURE (7c). + 23 ‘CUENT REFERENCE NO. NP RELATIVE HUMIDITY (96). + 50 est meTHOD ASTM F 60698 TesteD BY: TEST RESULTS Specimen No. LOAD AT FAILURE (KN) 1 38.415, TESTMETHODUARATION —_ NI REMARKS Test winesed by Constant & Contractor Signed for and on behalf of Independent Soil Tsing Laboratories LC Engr Yasir a "Technical Manager oe reset nyo a ‘aero satrete een nn UL na etn prt a. sete. Independent Soll Testing Laboratories. LLC opo-5 yl yaad Uiall oly stso AWS, Neer NOC, Mussfeh, Abu Dhab, UAE El wibol abe, yugarolYiLesAll—o/Ge— 0. Box 145843, ek +971 26559252 +4V1r O0OFTFr lia JEONE Cay mi: istad@utook com, Websi: wuiaae ‘winist 28 «95151 doa. istiabaoutlook com.3i6s1S0U a1 INDEPENDENT Cilio REPORT ON TENSILE STRENGTH OF THRU BOLT Pagel of 1 ‘cuent MUS Al Hal & Al Mukaddam For Geotechnical Work (LLC) REPORTNO. : ITLt10820025 102 CONSULTANT + MVS ASAS Group DATEREPORTED : 1/04/2020 CONTRACTOR 1 MVS Stone Hertage LIC LAB REFERENCENO. + ISTLN10420.025 PROJECT NAME 2 Mowhella G45 LAB PROJECT NO. = ISTLC-585 PROJECT NO. NP LABSAMPLENO. +: IsTL-t10420.025 PROJECT LOCATION Mowhele SAMPLED BY + Customer SAMPLE DESCRIPTION Th dott SAMPLE BROUGHT IN BY: ISTL Rep. SOURCE OF SAMPLE 2 NP SAMPUNG DATE + 07/08/2020 SAMPLE IDENTIFICATION NO. 10mm Bolt DATESAMPLE RECEIVED : 07/04/2020 SAMPLE SI2E 2Nor DATEOF TEST : 11/04/2020 SENDER REFERENCE NO. NP AMBIENT TEMPERATURE Cc): 23 CCUENT REFERENCE NO. NP RELATIVE HUMIDITY (@6). + 50 Test METHOD 2 ASTM A 37049¢1 TesteD BY + su TEST RESULTS iret Tensile Load (KN) ‘TENSILE STRENGTH (N/mm?) 1 39.162 498.879 TEST METHOD VARIATION Ni REMARKS “Test wlnesed by Constant & Contractor Signed for and on behalf of Independent Soll Tertng Laboratories LIC. soe ret oe nae ne, ‘ier shat nto eeasedecstin het newton spor ofthe ioe. sna 0: Independent Soil Testing Laboratories. L.L.C 90-5 Syl yaad) Aaallolstdo AWS, Neer NMDG, Mussafa, Abu Dhabi UAE Elbo abe0.uHg3(O1U Lo yBlU~ OMA o O, Box 145843, Tot: +971 25553232 “441 O0OPTFr Bila JEOREP LD Emit isleb@autook.com, Website: wwmisi.2e wise «3403151166001 istlabeoutiook com3iq)iSIU ays

You might also like