Professional Documents
Culture Documents
0XOWLIXQFWLRQ7UDQVGXFHU
MT440
Page1 WWW.ISKRAMIS.SI
!"
#$%&#"&'%%(%&#
&)*+ ,
3523(57,(6
&203/,$1&(:,7+67$1'$5'6
x 0HDVXUHPHQWVRILQVWDQWDQHRXVYDOXHVRIPRUH
WKDQ TXDQWLWLHV 9 $ N: N9$ NYDU N:K Standard EN Description
NYDUK3)+]0'WKHUPDO7+'HWF Safety requirements for electrical
61010-1: 2001 equipment for measurement, control
x 3RZHUDFFXUDF\FODVV and laboratory use
x 6HULDO FRPPXQLFDWLRQ 56 RU 56 XS WR EMC requirements for electrical
equipment for measurement, control
ELWVDQG86% 61326-1:2006
and laboratory use - Part 1: General
requirements
x 02'%86578FRPPXQLFDWLRQSURWRFRO
60529:1997/A1:2000 Degrees of protection provided by
x 8SWR,2DQDORJXHRXWSXWVDODUPRXWSXWV enclosures (IP code)
SXOVHRXWSXWVJHQHUDOSXUSRVHUHOD\RXWSXW
Environmental testing (-1 Cold, -2 Dry
JHQHUDOSXUSRVHVROLGVWDWHRXWSXW 60 068-2-1/ -2/ -6/
heat, -30 Damp heat, -6 Vibration, -27
-27/-30
Shock)
x 6LQJOHZLGHDX[LOLDU\SRZHUVXSSO\UDQJH±
9GF±9DF Tests for flammability of plastic
UL 94 materials for parts in devices and
x $XWRPDWLFUDQJHRIFXUUHQWDQGYROWDJHPD[ appliances
$DQG9/1
x +RXVLQJIRU',1UDLOPRXQWLQJ
$33/,&$7,21
x 8VHUIULHQGO\VHWWLQJVRIWZDUH0L4HQ The MT440 multifunction transducer is used for measuring
and monitoring of all single-phase or three-phase values.
Wide range of various I/O modules makes MT440 a perfect
'(6&5,37,21 choice for numerous applications. MT440 is delivered un-
MT440 are intended for measuring and monitoring single- configured for customer configuration with user friendly
phase or three-phase electrical power network. They setting software MiQen. MT440 supports standard serial
measure RMS value by means of fast sampling of voltage communication RS232 or RS485 with speed up to 115200
and current signals, which makes instruments suitable for baud, which is perfect for simple applications and serial bus
acquisition of transient events. A built-in microcontroller interfacing.
calculates measurands (voltage, current, frequency, energy,
power, power factor, THD phase angles, etc.) from the Additional USB 2.0 interface can only be used for a fast set-
measured signals up without need for auxiliary power supply. This interface is
NOT galvanically isolated from power inputs (aux. supply
and measurement inputs) and can be used ONLY
unconnected to power inputs.
352*5$00,1*
MT440 multifunction transducer is completely programmable.
Primary-secondary ratio (U, I), alarm limits, energy counter,
input and output values are all programmed by setting
software MIQen via RS232 or RS485 communication.
Page2 WWW.ISKRAMIS.SI
!"
#$%&#"&'%%(%&#
&)*+ ,
7(&+1,&$/'$7$ &20081,&$7,21
0($685(0(17,1387 D MT440 has one galvanically separated communication port,
Nominal frequency 50/60, 400 Hz which can be equipped with RS232 or RS485 or left open (to
&XUUHQWPHDVXUHPHQWV be specified with order).
Different configurations are possible (to be specified with
Nominal values 1, 5, 10 A
order):
Nominal current (IN) 5A
Max. measured value 12.5 A sinusoidal
Configuration COM
Max. allowed value (thermal) 15 A cont.
WO USB (2)
(acc. to EN 60 688) 20 × IN ; 5 × 1s (2)
RS232 RS232 + USB
Consumption < I2 × 0.01: per phase
RS485 RS485 + USB (2)
9ROWDJHPHDVXUHPHQWV
(2)
Nominal values 62.5, 125, 250, 500 VLN Read WARNING
Nominal voltage(UN) 500 VLN
Max. measured value (cont.) 600 VLN ; 1000 VLL Serial communication: RS232 RS485
Max. allowed value 2 × UN; 10 s Connection type Direct Network
(acc. to EN 60 688) Connection terminals screw terminals screw terminals
2
Consumption < U / 3.3M: per phase Function Settings, measurements and
Input impedance 3.3M: per phase firmware upgrade
)UHTXHQF\PHDVXUHPHQW Insulation Protection class II, 3.3 kVACRMS 1 min
Max. connection
Frequency measuring range 16 … 400 Hz
length 3m 1000 m
(Only for frequency meas.)
Transfer mode Asynchronous
Protocol MODBUS RTU
6\VWHP
Transfer rate 2.4 kBaud to 115.2 kBaud
Voltage inputs can be connected either directly to low-
Number of bus
voltage network or via a high-voltage transformer to high-
stations / d 32
voltage network.
Current inputs can be connected either directly to low-
voltage network or shall be connected to network via a
Additionally, MT440 has a USB communication port, located
corresponding current transformer (with standard 1 A or 5 A
on the bottom under small circular plastic cover. It is
outputs).
intended for settings ONLY and requires NO auxiliary power
For more information about different system connections see
supply. When connected to this communication port MT440
CONNECTION on page 6.
is powered by USB.
%$6,&$&&85$&<81'(55()(5(1&(&21',7,216 :$51,1*
7RWDO DFFXUDF\ PHDVXUHPHQWV DQG DQDORJXH RXWSXW USB communication port is NOT galvanically isolated and
DFFRUGLQJWR(1 can ONLY be used unconnected to aux. supply AND power
Accuracy is presented as percentage of measurands
inputs.
nominal value except when it is stated as an absolute value.
Presented accuracy is valid only for a full output range. In
case if used output range is less than full output range
(zoom-characteristics) see INTRINSIC ERROR on page 5. USB:
Defined accuracy of analogue output is valid only after 45 Connection type Direct
minutes after power up, due to self-heating. Connection terminal USB-mini
Max. connection length 3m
Accuracy Function Settings, firmware upgrade
Measurand
(r % of range)
Transfer mode Asynchronous
Current Rms 0.3 0.2(1) Protocol MODBUS RTU
Voltage Rms P-N and P-P 0.3 0.2(1)
Transfer rate USB 2.0
Power (P, Q, S) 0.5 0.3(1)
Power factor (PF) 0.2°
Frequency (f) 10 mHz 2 mHz(1)
P-N and P-P angle 0.2
THD (U), THD (I) (0 … 400 %) 0.5
Active energy Class 1
Reactive energy Class 2
(1)
On communication
WWW.ISKRAMIS.SI Page3
!"
#$%&#"&'%%(%&#
&)*+ ,
0
,138728738702'8/(6 (OHFWURPHFKDQLFDO5HOD\RXWSXW
MT440 can be equipped with up to four modules. The Purpose alarm, pulse, general purpose
following modules are available: digital output
Type Electromechanical Relay
Analogue output up to 4 any I/O switch
Fast analogue output up to 4 any I/O Rated voltage 48 V AC/DC (+40% max)
Electromechanical relay output up to 4 any I/O Max. switching current 1000 mA
Solid-state relay output up to 4 any I/O Contact resistance 100 m (100 mA, 24V)
Pulse (if used as Max. 4000 imp/hour
pulse output) Min. length 100 ms
Electromechanical or solid-state relay output can be used as:
Insulation voltage
- Alarm output
Between coil and contact 4000 VDC
- Pulse output
Between contacts 1000 VDC
- General purpose digital output
$QDORJXHRXWSXW 6ROLGVWDWHUHOD\RXWSXW
Each of up to four analogue outputs is fully programmable
Purpose alarm, pulse, general purpose
and can be set to any of 6 full-scale ranges (4 current and 2 digital output
voltage) without opening an instrument. They all use the Type Optocoupler open collector
same output terminals. It is possible to set other subranges switch
(e.g. 4 … 20 mA) by setting breakpoints. Rated voltage 40 V AC/DC
)$67 DQDORJXH RXWSXW has the same functionality as Max. switching current 30 mA (RONmax = 8)
standard analogue output with faster response time. Pulse length programmable (2 … 999 ms)
Programmable DC current output: (if used as pulse output)
Page4 WWW.ISKRAMIS.SI
!"
#$%&#"&'%%(%&#
&)*+ ,
0L4HQVHWWLQJDQGDFTXLVLWLRQ6RIWZDUH
(19,5210(17$/&21',7,216 MiQen software is intended for supervision of MT440 and
Ambient temperature usage group III many other instruments on a PC. Network and the
- 10 … 0…45 … 55 °C transducer setting, display of measured values are possible
Acc. to IEC/EN 60 688
via the serial communication. The information and
Operating temperature - 30 to + 70 °C
Storage temperature - 40 to +70 °C measurements can be exported in standard Windows
Average annual humidity d 93% r.h. formats. Multilingual software functions on Windows 98,
Altitude d 2000 m 2000, NT, XP, Vista, Windows 7 operating systems.
,175,16,&(5525)25$1$/2*8(2873876
Linear characteristic
y
ye
c or c
x
xe
Bent characteristic
MiQen software is intended for:
xb d x d xb Setting all of the instruments parameters (online and offline)
Viewing current measured readings
b – number of break point (1 to 5)
Setting and resetting energy counters
Complete I/O modules configuration
yb yb xe Searching the net for devices
c or c
xb xb ye Virtual interactive instrument
Comprehensive help support
$/$506
MT440 supports setting up to 16 alarms in two alarm groups.
Alarms can be set for any of measured parameters by setting
condition and a limit value. A time constant of maximum
demand values in a thermal mode, a delay time and switch-
off hysteresis are defined for each group of alarms. To each
of two alarm groups an alarm output (solid-state or
electromechanical relay) can be dedicated.
WWW.ISKRAMIS.SI Page5
!"
#$%&#"&'%%(%&#
&)*+ ,
1
&211(&7,21
Three-phase
four wire
Single-phase
connection
connection
with
1b (1W)
balanced
load
4b (1W4)
Three-phase
three-wire Three-phase
connection four wire
with connection
balanced with
load unbalanced
3b (1W3) load
4u (3W4)
Three-phase
three-wire
connection
with
unbalanced
load
3u (2W3)
Page6 WWW.ISKRAMIS.SI
!"
#$%&#"&'%%(%&#
&)*+ ,
',0(16,21$/'5$:,1*
&211(&7,217$%/(
Function Connection
IL1 1/3
AC current IL2 4/6
IL3 7/9
Measuring input: UL1 2
UL2 5
AC voltage
UL3 8
N 11
I/O
C+ 15
I/O 1
C 16
C+ 17
I/O 2
C 18
Inputs / outputs:
C+ 19
I/O 3
C 20
C+ 21
I/O 4
C 22
+ / AC (L) 13
Auxiliary power supply:
– / AC (N) 14
Rx / A 23
RS232 /
Communication: GND / NC 24
RS485
Tx / B 25
WWW.ISKRAMIS.SI Page7
!"
#$%&#"&'%%(%&#
&)*+ ,
'$7$)2525'(5,1* *(1(5$/25'(5,1*&2'(
The following data shall be stated: All specifications are obligatory except function of analogue
output(s), which should be stated in a form of description.
Type of transducer
Input frequency 1. Transducer type:
Type of communication MT440
Type of I/O module(s)
Supplement: 2. Input frequency
MiQen software 1 50/60 Hz
2 400 Hz
25'(5,1*
When ordering MT440, all required specifications should be 3. Communication type (COM)
stated in compliance with the ordering code. Additional 0 Without
information could be stated regarding functionality of 1 RS232
analogue outputs. Default settings for analogue outputs 2 RS485
provided that no ordering information is given will be:
4. I/O 1
Analogue output Input quantity Output quantity 0 Without
1 Analogue output
AO1 P (-7500...0...7500)W -20...0...20 mA 2 Fast analogue output
AO2 Q (-7500...0...7500)var -20...0...20 mA 3 Solid-state relay output
AO3 U1 (0...500V) 0 … 20 mA 4 Electromechanical relay output
AO4 I1 (0...5A) 0 ... 20 mA
5. I/O 2
If different analogue output settings are required, a proper 0 Without
input quantity / output quantity pair for each analogue output 1 Analogue output
should be provided. 2 Fast analogue output
The transducers automatic range of input current (5 A) and 3 Solid-state relay output
voltage (500 VL-N) is not stated in the code. 4 Electromechanical relay output
(;$03/(2)25'(5,1* 6. I/O 3
MT440 transducer is connected to a secondary phase voltage 0 Without
(50 Hz) up to 500 VL-N and 5 A secondary current. RS 232 1 Analogue output
communication, two analogue outputs, one electromechanical 2 Fast analogue output
relay alarm output and one solid-state pulse output are 3 Solid-state relay output
applied. 4 Electromechanical relay output
Ordering code:
MT440 1 1 1 1 4 3 7. I/O 4
0 Without
1 Analogue output
2 Fast analogue output
3 Solid-state relay output
4 Electromechanical relay output
PrintedinSloveniaxSubjecttochangewithoutnoticexVersion1.00/Feb2011xGBP22.496.500
!"
#$%&#"&'%%(%&#
&)*+ ,