SELECTION GUIDE – Autoradiography Methods and Materials for Life Science Applications
Application Result Required Label Method Film Support products
Southern/Northern blots; High speed and sensitivity; Accurate quantification 32P Pre-flash with screens at -70°C Hyperfilm MP Sensitize, Hyperscreen Colony/plaque blots Maximum speed and sensitivity 32P Screens at -70°C BioMax MS BioMax TranScreen HE Optimum resolution 32P/35S Direct autoradiography Hyperfilm bmax/BioMax MR Non-radioactive; quantification ECL Pre-flash and direct detection Hyperfilm ECL Sensitize Slot blots High speed and sensitivity; accurate quantification 32P Pre-flash with screens at -70°C Hyperfilm MP Sensitize, Hyperscreen Maximum speed and sensitivity 32P Screens at -70°C BioMax MS BioMax TranScreen HE Non-radioactive, quantification ECL Pre-flash and direct detection Hyperfilm ECL Sensitize Dideoxy sequencing High speed 32P Direct autoradiography Hyperfilm MP/BioMax MR Optimum resolution and maximum speed for difficult 32S Direct autoradiography Biomax MR sequences Good resolution and speed for routine work 32S Direct autoradiography Hyperfilm MP Cycle sequencing Optimum resolution and maximum speed for difficult 32P Direct autoradiography BioMax MR sequences Good resolution and speed for routine work 33P Direct autoradiography Hyperfilm MP Protein synthesis, lysates Maximum speed 35S/14C/3H Pre-flash and fluorography at -70°C Hyperfilm MP Amplify, Sensitize Optimum resolution 125I Indirect autoradiography BioMax MS BioMax TranScreen HE Direct autoradiography Hyperfilm 3H Western blots Maximum speed and sensitivity 125I Pre-flash and screens at -70°C Hyperfilm MP/BioMax MS Sensitize, Hyperscreen, BioMax TranScreen HE Optimum resolution 35S/14C Direct autoradiography Hyperfilm bmax/BioMax MR Non-radioactive/maximum sensitivity ECL Pre-flash and direct detection Hyperfilm ECL Sensitize In situ hybridization Macroscale in situ optimization of parameters 32P Direct autoradiography Hyperfilm MP Receptor studies Localization at cellular level 33P/35S Direct autoradiography Hyperfilm bmax/BioMax MR – intermediate resolution – high resolution 33P/35S Micro autoradiography Hypercoat emulsion LM-1 Localization at sub-cellular level 125I/3H Direct autoradiography Hyperfilm 3H – intermediate resolution – high resolution 125I/3H Micro autoradiography Hypercoat emulsion EM-1 Whole body autoradiography Optimum resolution 125I/3H Direct autoradiography Hyperfilm 3H High resolution 35S/14C Direct autoradiography Hyperfilm bmax/BioMax MR