Underground Cable Installation Details

This document provides a diagram and details of an underground cable installation. It shows the cable buried under crushed rock backfill above undisturbed earth. Warning tape is placed above the cable. Spot details show a manhole cover made of steel checker plate attached to an angular steel frame by hinged cylindrical bars and spike bars. Landscaping will be restored to pre-existing conditions after excess material is mounded to allow for settlement.

Uploaded by

Alexis Aguillon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
489 views1 page

Underground Cable Installation Details

This document provides a diagram and details of an underground cable installation. It shows the cable buried under crushed rock backfill above undisturbed earth. Warning tape is placed above the cable. Spot details show a manhole cover made of steel checker plate attached to an angular steel frame by hinged cylindrical bars and spike bars. Landscaping will be restored to pre-existing conditions after excess material is mounded to allow for settlement.

Uploaded by

Alexis Aguillon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

LEGEND:

PRIMARY

SECONDARY

AREA TRANSFORMER

0.80 0.80

0.40 0.40
CLASS "B" 3 4" -0" CRUSHED
ROCK GRANULAR BACKFILL
SEE SPOT DETAIL
0.10

MOUND EXCESS MATERIAL TO ALLOW THE


SETTLEMENT, CONTRACTOR SHALL ALL 12mm∅ BARS SP. @ 0.20m.o.c.
LANDSCAPING TO PRE-EXISTING CONDITIONS.
1.00

1.00

1.20

1.20

WARNING TAPE/ CAUTION


ELECTRICAL CABLE BELOW

100mm∅ uPVC

4-12mm∅ BARS
0.20

LEGEND: 100mm∅ uPVC


0.05

0.10

MOUND EXCESS MATERIAL TO ALLOW THE


SETTLEMENT, CONTRACTOR SHALL ALL
LANDSCAPING TO PRE-EXISTING CONDITIONS.
SECTION OF UNDERGROUND CABLE INSTALLATION
CLASS "B" 3 4" -0" CRUSHED SCALE : 1:20mts. 6mm THK. STEEL
ROCK GRANULAR BACKFILL
20mm∅ CYLINDRICAL HINGED
CHECKERED PLATE

UNDISTURBED EARTH

WARNING TAPE/ CAUTION 6mm x 50mm x


10mm∅ SPIKE BAR 200mm FLAT BAR
ELECTRICAL CABLE BELOW
75mm x 75mm x 6mm
10mm SPIKE BARS 0.80 ANGULAR BAR FRAME

SPOT DETAIL
20mm∅ CYLINDRICAL HINGED NOT TO SCALE

10mm SPIKE BARS

6mm THK. STEEL


0.60

CHECKERED PLATE

75mm x 75mm x 6mm


ANGULAR BAR FRAME 75mm x 75mm x 6mm
ANGULAR BAR FRAME

MANHOLE COVER DETAIL


SCALE: 1:10mts.

You might also like