You are on page 1of 20

Data Communication Products

Premises Copper

purenetcable.com
Table of Contents

Premises Category cables


Category 6A 650MHz UTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Category 6A 650MHz FTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Category 6+ 550MHz UTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Category 6+ 550MHz FTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Category 6 500MHz UTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Category 5e 350MHz UTP Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

RG cables
RG6 Coax Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Category Cable Part Number Key


- -
A B C D E F

U Unshielded Twisted Pair


A Cable Type
F Foiled Twisted Pair
5350 Category 5e 350MHz
6500 Category 6 500MHz
B Category
6550 Category 6+ 550MHz
6A650 Category 6A 650MHz
C Pair Count 004 4-Pair
P Plenum
D Listing
R Riser
BL Blue
WH White
GY Grey
BK Black
E Jacket Color YL Yellow
GN Green
RD Red
OR Orange
VI Violet
1 Reelex I
2 Reelex II
F Package Type
3 Reel In a Box
4 Reel

RG6 Cable Part Number Index


- - - -
A B C D E F G

A Cable Type RG6


S Standard (60%)
B Shield
Q Quad
C Conductor Material S CCS
M CM
D Listing
R CMR
WH White
E Jacket Color
BK Black
F Appendix Optional
G Packaging Type 2 Reelex
e.g. RG6Q-S-RBK-2 RG6 Quad Cable, CCS Conductor Riser, Black, Reelex Box

purenetcable.com 1
Category 6A 650MHz UTP Cable
U6A650-004-xxxx

Riser
Conductor

Insulation (HDPE/FEP)

Rip Cord (Optional)

Twisted Pair

Jacket (PVC)

Conductor

Insulation (HDPE/FEP)

Rip Cord (Optional)

Twisted Pair

Jacket (PVC)

Plenum

Description Application
• UL Listed CMR and CMP • Horizontal Distribution & Backbone Cabling
• UL Verified • 155Mbps ATM, 100Mbps TP-PMD
• Capable of handling full broadband and baseband video signals • 10/100/1000/10GBASE-T (IEEE 802.3)
• Tight balance requirements improve cable performance • ISDN, ADSL
• Every master reel is tested for electrical performance • ATM LAN 1.2G
compliance • PoE, PoE+ and PoE++ (IEEE 802.3bt draft. Type 3 & 4)
• Dual length marking in feet and meters from 1000 ft (305 m)
to 0 ft (0 m)
• RoHS compliant

Part Numbers
Description
Category 6A UTP Cable, 4-Pair, Category 6A UTP Cable, 4-Pair,
Jacket Color Riser Rated Plenum Rated
Blue U6A650-004-RBL4 U6A650-004-PBL4
White U6A650-004-RWH4 U6A650-004-PWH4
Grey U6A650-004-RGY4 U6A650-004-PGY4
Black U6A650-004-RBK4 U6A650-004-PBK4
Yellow U6A650-004-RYL4 U6A650-004-PYL4
Green U6A650-004-RGN4 U6A650-004-PGN4
Red U6A650-004-RRD4 U6A650-004-PRD4
Orange U6A650-004-ROR4 U6A650-004-POR4
Violet U6A650-004-RVI4 U6A650-004-PVI4

2 purenetcable.com
Performance Characteristics
Meet or exceed TIA-568-C.2 Category 6A requirements
Return Loss (RL) Minimum Insertion Loss (Attenuation) Maximum
dB/100 m dB/100 m
Frequency¹ TIA-568-C.2 U6A650-R U6A650-P TIA-568-C.2 U6A650-R U6A650-P
(MHz) Standard Typical Typical Standard Typical Typical
1 20.0 37.27 41.08 2.1 1.78 1.62
4 23.0 33.71 31.43 3.8 3.46 3.18
10 25.0 36.72 33.12 5.9 5.62 5.19
16 25.0 37.27 34.04 7.5 7.14 6.60
20 25.0 37.81 34.91 8.4 8.00 7.43
31.25 23.6 40.45 37.59 10.5 10.04 9.36
62.5 21.5 39.91 37.55 15.0 14.47 13.68
100 20.1 39.33 36.52 19.1 18.41 17.61
200 18.0 38.02 36.14 27.6 26.44 25.91
250 17.3 36.34 35.71 31.1 29.55 29.19
300 16.8 34.97 33.50 34.3 33.13 32.60
400 15.9 34.27 32.27 40.1 37.71 38.01
500 15.2 34.08 31.56 45.3 42.53 43.27
600 30.00 28.00 47.00 47.00
650 30.00 49.00 49.00

Near End Cross Talk (NEXT) Minimum Equal Level Far End Cross Talk (ELFEXT) Minimum
dB/100 m dB/100 m
Frequency¹ TIA-568-C.2 U6A550-R U6A550-P TIA-568-C.2 U6A650-R U6A650-P
(MHz) Standard Typical Typical Standard Typical Typical
1 74.3 89.37 88.21 67.8 88.93 88.19
4 65.3 83.69 82.63 55.8 83.49 83.83
10 59.3 81.90 74.19 47.8 82.35 77.18
16 56.2 75.24 73.86 43.7 77.09 74.12
20 54.8 72.85 73.24 41.8 72.19 71.22
31.25 51.9 67.22 67.10 37.9 68.05 63.13
62.5 47.4 62.60 63.26 31.9 63.08 62.93
100 44.3 61.45 58.33 27.8 58.99 56.97
200 39.8 54.77 53.27 21.8 56.08 55.22
250 38.3 54.73 53.00 19.8 54.81 54.90
300 37.1 53.36 52.54 18.3 54.53 48.22
400 35.3 47.48 50.50 15.8 53.51 47.49
500 33.8 46.25 45.81 13.8 42.66 43.99
600 45.00 45.00 42.00 42.00
650 45.00 45.00 41.50 41.50
¹Value above 550Mhz are for informational purposes only

Technical Details
Item Unit Riser Plenum
Conductor DC Resistance Max. Ohms/100 m 9.38 9.38
Resistance Unbalance Max. % 5 5
Mutual Capacitance Max. nF/100 m 5.6 5.6
Capacitance Unbalance Max. pF/100 m 330 330
Characteristic Impedance Ohms 100 ± 15% 100 ± 15%
Propagation Delay Max. ns/100 m 535 @ 650MHz 535 @ 650MHz
Delay Skew Max. ns 45 45
Nominal Velocity of Propagation % 67 70
Operating Temperature °F (°C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75)
Storage Temperature °F (°C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90)
Bending Radius 4 x Cable diameter 4 x Cable diameter
Type 1 kft (305 m) Reel Reel
Packaging: Weight lb/kft (kg/km) 43 (65) 43 (65)
Packages Per Pallet 12 12
Conductors 23 AWG, Solid copper 23 AWG, Solid copper
Materials: Insulation in (mm) 0.045 (1.15), HDPE 0.041 (1.05), FEP
Jacket in (mm) 0.331 (8.4), PVC 0.334 (8.5), LS-PVC (Plenum Rated)
Safety UL 444, UL 1666 UL 444, NFPA 262
Approvals:
Performance TIA-568-C.2 “Balanced Twisted-Pair Telecommunications Cabling and Components Standards”

purenetcable.com 3
Category 6A 650MHz FTP Cable
F6A650-004-xxxx

Conductor

Insulation (HDPE/FEP)

Drain Wire

Twisted Pair
Aluminum Tape
Jacket (PVC)

Description
• UL Listed and Verified
• Capable of handling full broadband and baseband video signals
• Tight balance requirements improve cable performance
• Superior RFI, EMI and alien crosstalk performance by shield technology
• Every master reel is tested for electrical performance compliance
• Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m)
• Slim Cable Diameter of 0.283 in. (7.2 mm)
• RoHS compliant

Application
• Horizontal Distribution & Backbone Cabling
• 155Mbps ATM, 100Mbps TP-PMD
• 10/100/1000/10GBASE-T (IEEE 802.3)
• ISDN, ADSL
• ATM LAN 1.2G
• PoE, PoE+ and PoE++ (IEEE 802.3bt draft. Type 3 & 4)

Part Numbers
Description
Category 6A FTP Cable, 4-Pair, Category 6A FTP Cable, 4-Pair,
Jacket Color Riser Rated Plenum Rated
Blue F6A650-004-RBL4 F6A650-004-PBL4
White F6A650-004-RWH4 F6A650-004-PWH4
Grey F6A650-004-RGY4 F6A650-004-PGY4
Black F6A650-004-RBK4 F6A650-004-PBK4
Yellow F6A650-004-RYL4 F6A650-004-PYL4
Green F6A650-004-RGN4 F6A650-004-PGN4
Red F6A650-004-RRD4 F6A650-004-PRD4
Orange F6A650-004-ROR4 F6A650-004-POR4
Violet F6A650-004-RVI4 F6A650-004-PVI4

4 purenetcable.com
Performance Characteristics
Meet or exceed TIA-568-C.2 Category 6A requirements
Return Loss (RL) Minimum Insertion Loss (Attenuation) Maximum
dB/100 m dB/100 m
Frequency¹ TIA-568-C.2 F6A650-R F6A650-P TIA-568-C.2 F6A650-R F6A650-P
(MHz) Standard Typical Typical Standard Typical Typical
1 20.0 37.30 37.30 2.1 1.79 1.79
4 23.0 31.83 31.83 3.8 3.30 3.30
10 25.0 32.72 32.72 5.9 5.26 5.26
16 25.0 36.61 36.61 7.5 6.69 6.69
20 25.0 39.05 39.05 8.4 7.52 7.52
31.25 23.6 37.54 37.54 10.5 9.39 9.39
62.5 21.5 37.04 37.04 15.0 13.47 13.47
100 20.1 30.14 30.14 19.1 17.11 17.11
200 18.0 29.21 29.21 27.6 24.50 24.50
250 17.3 28.70 28.70 31.1 27.29 27.29
300 16.8 28.43 28.43 34.3 29.81 29.81
400 15.9 25.95 25.95 40.1 34.70 34.70
500 15.2 24.28 24.28 45.3 39.00 39.00
600 23.70 23.70 44.00 44.00
650 23.50 23.50 46.00 46.00

Near End Cross Talk (NEXT) Minimum Equal Level Far End Cross Talk (ELFEXT) Minimum
dB/100 m dB/100 m
Frequency¹ TIA-568-C.2 F6A650-R F6A650-P TIA-568-C.2 F6A650-R F6A650-P
(MHz) Standard Typical Typical Standard Typical Typical
1 74.3 88.03 88.03 67.8 84.38 84.38
4 65.3 81.50 81.50 55.8 83.14 83.14
10 59.3 72.16 72.16 47.8 71.06 71.06
16 56.2 69.38 69.38 43.7 68.75 68.75
20 54.8 68.22 68.22 41.8 68.40 68.40
31.25 51.9 64.58 64.58 37.9 68.29 68.29
62.5 47.4 59.63 59.63 31.9 59.49 59.49
100 44.3 55.67 55.67 27.8 57.56 57.56
200 39.8 54.20 54.20 21.8 52.77 52.77
250 38.3 53.28 53.28 19.8 51.06 51.06
300 37.1 51.37 51.37 18.3 50.03 50.03
400 35.3 48.82 48.82 15.8 48.38 48.38
500 33.8 48.70 48.70 13.8 48.04 48.04
600 47.00 47.00 46.00 46.00
650 46.50 46.50 45.55 45.55
¹Value above 550Mhz are for informational purposes only

Technical Details
Item Unit Riser Plenum
Conductor DC Resistance Max. Ohms/100 m 9.38 9.38
Resistance Unbalance Max. % 5 5
Mutual Capacitance Max. nF/100 m 5.6 5.6
Capacitance Unbalance Max. pF/100 m 330 330
Characteristic Impedance Ohms 100 ± 15% 100 ± 15%
Propagation Delay Max. ns/100 m 535 @ 650MHz 535 @ 650MHz
Delay Skew Max. ns 45 45
Nominal Velocity of Propagation % 67 70
Operating Temperature °F (°C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75)
Storage Temperature °F (°C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90)
Bending Radius 4 x Cable diameter 4 x Cable diameter
Type 1 kft (305 m) Reel Reel
Packaging: Weight lb/kft (kg/km) 43 (65) 43 (65)
Packages Per Pallet 12 12
Conductors 23 AWG, Solid copper 23 AWG, Solid copper
Materials: Insulation in (mm) 0.043 (1.1), HDPE 0.043 (1.1), FEP
Jacket in (mm) 0.283 (7.2), PVC 0.295 (7.5), LS-PVC (Plenum Rated)
Safety UL 444, UL 1666 UL 444, NFPA 262
Approvals:
Performance TIA-568-C.2 “Balanced Twisted-Pair Telecommunications Cabling and Components Standards”

purenetcable.com 5
Category 6+ 550MHz UTP Cable
U6550-004-xxxx

Conductor

Insulation (HDPE/FEP)

Rip Cord (Optional)

Twisted Pair

Jacket (PVC)

Description
• UL Listed CMR and CMP
• UL and ETL Verified
• Capable of handling full broadband and baseband video signals
• Tight balance requirements improve cable performance
• Every master reel is tested for electrical performance compliance
• Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m)
• Plastic Reel-in-a-Box packaging allows easy access and low tension pulls
• RoHS compliant

Application
• Horizontal Distribution and Backbone Cabling
• 155 Mbps ATM, 100 Mbps TP-PMD
• 10/100/1000 BASE-T (IEEE 802.3)
• 10GBASE-T up to max. 55 m
• ISDN, ADSL
• ATM LAN 1.2G
• PoE, PoE+ (IEEE 802.3af, IEEE 802.3at)

Part Numbers
Description
Category 6+ UTP Cable, 4-Pair, Category 6+ UTP Cable, 4-Pair,
Jacket Color Riser Rated Plenum Rated
Blue U6550-004-RBL3 U6550-004-PBL3
White U6550-004-RWH3 U6550-004-PWH3
Grey U6550-004-RGY3 U6550-004-PGY3
Black U6550-004-RBK3 U6550-004-PBK3
Yellow U6550-004-RYL3 U6550-004-PYL3
Green U6550-004-RGN3 U6550-004-PGN3
Red U6550-004-RRD3 U6550-004-PRD3
Orange U6550-004-ROR3 U6550-004-POR3
Violet U6550-004-RVI3 U6550-004-PVI3

6 purenetcable.com
Performance Characteristics
Meet or exceed TIA-568-C.2 Category 6 requirements
Return Loss (RL) Minimum Insertion Loss (Attenuation) Maximum
dB/100 m dB/100 m
Frequency² TIA-568-C.2 U6550-R U6550-P TIA-568-C.2 U6550-R U6550-P
(MHz) Standard Typical Typical Standard Typical Typical
1 20.0 32.47 29.11 2.0 1.67 1.64
4 23.0 35.22 32.41 3.8 3.28 3.23
10 25.0 35.37 33.16 6.0 5.33 5.31
16 25.0 36.36 34.00 7.6 6.77 6.76
20 25.0 40.57 37.15 8.5 7.61 7.58
31.25 23.6 40.31 37.04 10.7 9.58 9.58
62.5 21.5 38.18 36.64 15.4 13.91 13.92
100 20.1 38.12 34.00 19.8 17.75 17.86
200 18.0 36.48 33.25 29.0 25.57 25.87
250 17.3 33.96 33.24 32.8 28.70 29.52
300 33.08 32.48 31.70 32.91
400 32.82 29.54 36.63 38.09
500 30.00 27.00 37.60 39.00
550 29.00 26.00 38.00 40.00

Near End Cross Talk (NEXT) Minimum Equal Level Far End Cross Talk (ELFEXT) Minimum
dB/100 m dB/100 m
Frequency² TIA-568-C.2 U6550-R U6550-P TIA-568-C.2 U6550-R U6550-P
(MHz) Standard Typical Typical Standard Typical Typical
1 74.3 90.90 90.20 67.8 90.02 87.94
4 65.3 87.56 78.98 55.8 88.03 78.84
10 59.3 77.42 75.67 47.8 74.72 75.82
16 56.2 74.65 73.12 43.7 73.97 75.29
20 54.8 73.30 70.97 41.8 69.69 71.51
31.25 51.9 69.83 66.18 37.9 67.73 65.01
62.5 47.4 68.79 63.70 31.9 65.12 64.39
100 44.3 65.48 61.67 27.8 60.79 60.07
200 39.8 63.59 54.78 21.8 59.75 56.31
250 38.3 55.89 51.36 19.8 57.54 47.75
300 53.31 50.54 54.17 47.72
400 53.11 43.43 49.60 45.71
500 52.00 42.10 48.00 44.50
550 51.00 41.00 47.00 43.00
²Value above 250Mhz are for informational purposes only

Technical Details
Item Unit Riser Plenum
Conductor DC Resistance Max. Ohms/100 m 9.38 9.38
Resistance Unbalance Max. % 5 5
Mutual Capacitance Max. nF/100 m 5.6 5.6
Capacitance Unbalance Max. pF/100 m 330 330
Characteristic Impedance Ohms 100 ± 15% 100 ± 15%
Propagation Delay Max. ns/100 m 536 @ 550MHz 536 @ 550MHz
Delay Skew Max. ns 45 45
Nominal Velocity of Propagation % 67 70
Operating Temperature °F (°C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75)
Storage Temperature °F (°C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90)
Bending Radius 4 x Cable diameter 4 x Cable diameter
Type 1 kft (305 m) Reel-in-a-Box Reel-in-a-Box
Packaging: Weight lb/kft (kg/km) 24 (36) 26 (39)
Packages Per Pallet 27 27
Conductors 23 AWG, Solid copper 23 AWG, Solid copper
Materials: Insulation in (mm) 0.038 (0.97), HDPE 0.037 (0.95), FEP
Jacket in (mm) 0.236 (6.0), PVC 0.228 (5.8), LS-PVC (Plenum Rated)
Safety UL 444, UL 1666 UL 444, NFPA 262
Approvals:
Performance TIA-568-C.2 “Balanced Twisted-Pair Telecommunications Cabling and Components Standards”

purenetcable.com 7
Category 6+ 550MHz FTP Cable
F6550-004-xxxx

Conductor

Insulation (HDPE/FEP)

Drain Wire

Twisted Pair
Aluminum Tape
Jacket (PVC)

Description
• UL Listed and Verified
• Capable of handling full broadband and baseband video signals
• Tight balance requirements improve cable performance
• Superior RFI, EMI and alien crosstalk performance by shield technology
• Every master reel is tested for electrical performance compliance
• Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m)
• RoHS compliant

Application
• Horizontal Distribution & Backbone Cabling
• 155Mbps ATM, 100Mbps TP-PMD
• 10/100/1000BASE-T (IEEE 802.3)
• 10GBASE-T up to max. 55 m
• ISDN, ADSL
• ATM LAN 1.2G
• PoE, PoE+ and PoE++ (IEEE 802.3bt draft. Type 3)

Part Numbers
Description
Category 6+ FTP Cable, 4-Pair, Category 6+ FTP Cable, 4-Pair,
Jacket Color Riser Rated Plenum Rated
Blue F6550-004-RBL4 F6550-004-PBL4
White F6550-004-RWH4 F6550-004-PWH4
Grey F6550-004-RGY4 F6550-004-PGY4
Black F6550-004-RBK4 F6550-004-PBK4
Yellow F6550-004-RYL4 F6550-004-PYL4
Green F6550-004-RGN4 F6550-004-PGN4
Red F6550-004-RRD4 F6550-004-PRD4
Orange F6550-004-ROR4 F6550-004-POR4
Violet F6550-004-RVI4 F6550-004-PVI4

8 purenetcable.com
Performance Characteristics
Meet or exceed TIA-568-C.2 Category 6 requirements
Return Loss (RL) Minimum Insertion Loss (Attenuation) Maximum
dB/100 m dB/100 m
Frequency² TIA-568-C.2 F6550-R F6550-P TIA-568-C.2 F6550-R F6550-P
(MHz) Standard Typical Typical Standard Typical Typical
1 20.0 35.13 29.51 2.0 1.84 1.79
4 23.0 35.88 32.23 3.8 3.36 3.34
10 25.0 39.06 35.55 6.0 5.35 5.33
16 25.0 42.62 39.13 7.6 6.78 6.81
20 25.0 36.10 34.90 8.5 7.66 7.65
31.25 23.6 35.92 33.96 10.7 9.52 9.60
62.5 21.5 35.01 33.71 15.4 13.65 13.90
100 20.1 34.52 32.62 19.8 17.25 17.56
200 18.0 33.80 32.31 29.0 24.61 25.50
250 17.3 32.44 30.23 32.8 27.49 28.51
300 30.00 29.00 34.10 33.90
400 29.00 28.00 36.60 36.40
500 28.00 27.00 38.60 38.40
550 27.00 26.00 40.00 40.00

Near End Cross Talk (NEXT) Minimum Equal Level Far End Cross Talk (ELFEXT) Minimum
dB/100 m dB/100 m
Frequency² TIA-568-C.2 F6550-R F6550-P TIA-568-C.2 F6550-R F6550-P
(MHz) Standard Typical Typical Standard Typical Typical
1 74.3 92.20 87.56 67.8 86.41 89.61
4 65.3 77.38 77.98 55.8 77.85 79.51
10 59.3 73.35 72.79 47.8 75.54 75.44
16 56.2 67.18 71.88 43.7 68.18 71.73
20 54.8 65.58 67.29 41.8 66.35 68.93
31.25 51.9 62.87 66.60 37.9 63.68 66.37
62.5 47.4 59.73 63.90 31.9 62.95 62.77
100 44.3 57.22 63.28 27.8 59.70 58.35
200 39.8 55.05 53.58 21.8 47.70 57.42
250 38.3 51.96 51.74 19.8 46.36 54.63
300 45.00 46.00 36.00 35.00
400 41.00 42.00 34.00 34.00
500 39.00 40.00 32.00 32.00
550 38.40 39.40 31.00 31.00
²Value above 250Mhz are for informational purposes only

Technical Details
Item Unit Riser Plenum
Conductor DC Resistance Max. Ohms/100 m 9.38 9.38
Resistance Unbalance Max. % 5 5
Mutual Capacitance Max. nF/100 m 5.6 5.6
Capacitance Unbalance Max. pF/100 m 330 330
Characteristic Impedance Ohms 100 ± 15% 100 ± 15%
Propagation Delay Max. ns/100 m 536 @ 550MHz 536 @ 550MHz
Delay Skew Max. ns 45 45
Nominal Velocity of Propagation % 67 70
Operating Temperature °F (°C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75)
Storage Temperature °F (°C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90)
Bending Radius 4 x Cable diameter 4 x Cable diameter
Type 1 kft (305 m) Reel Reel
Packaging: Weight lb/kft (kg/km) 43 (65) 43 (65)
Packages Per Pallet 12 12
Conductors 23 AWG, Solid copper 23 AWG, Solid copper
Materials: Insulation in (mm) 0.043 (1.1), HDPE 0.043 (1.1), FEP
Jacket in (mm) 0.283 (7.2), PVC 0.283 (7.2), LS-PVC (Plenum Rated)
Safety UL 444, UL 1666 UL 444, NFPA 262
Approvals:
Performance TIA-568-C.2 “Balanced Twisted-Pair Telecommunications Cabling and Components Standards”

purenetcable.com 9
Category 6 500MHz UTP Cable
U6500-004-xxxx

Conductor

Insulation (HDPE/FEP)
Rip Cord (Optional)
Twisted Pair

Jacket (PVC)

Description
• UL Listed CMR and CMP
• UL and ETL Verified
• 90°C UL Listed & 0.5A-LP Rating for CMP
• Filler-less design simplifies installation
• Capable of handling full broadband and baseband video signals
• Every master reel is tested for electrical performance compliance
• Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m)
• Lightweight, easy-pull Reelex packaging eases installation
• Plastic Reel-in-a-Box packaging allows easy access and low tension pulls
• Slim cable outer diameter of 0.213 in. (Riser Rated), 0.205 in. (Plenum Rated)
• RoHS compliant

Application
• Horizontal Distribution • 10/100/1000BASE-T (IEEE 802.3) • ATM LAN 1.2G
& Backbone Cabling • 10GBASE-T up to max. 55 m • PoE, PoE+ (IEEE 802.3af, IEEE 802.3at)
• 155Mbps ATM, 100Mbps TP-PMD • ISDN, ADSL

Part Numbers
Description
Category 6 UTP Cable, Non X-filler 4-Pair, Category 6 UTP Cable, Non X-filler 4-Pair,
Riser Rated Plenum Rated
Jacket Color* Reelex Reel-in-a-Box Reelex Reel-in-a-Box
Blue U6500-004-RBL2 U6500-004-RBL3 U6500-004-PBL2 U6500-004-PBL3
White U6500-004-RWH2 U6500-004-RWH3 U6500-004-PWH2 U6500-004-PWH3
Grey U6500-004-RGY2 U6500-004-RGY3 U6500-004-PGY2 U6500-004-PGY3
Black U6500-004-RBK2 U6500-004-RBK3 U6500-004-PBK2 U6500-004-PBK3
Yellow U6500-004-RYL2 U6500-004-RYL3 U6500-004-PYL2 U6500-004-PYL3
Green U6500-004-RGN2 U6500-004-RGN3 U6500-004-PGN2 U6500-004-PGN3
Red U6500-004-RRD2 U6500-004-RRD3 U6500-004-PRD2 U6500-004-PRD3
Orange U6500-004-ROR2 U6500-004-ROR3 U6500-004-POR2 U6500-004-POR3
Violet U6500-004-RVL2 U6500-004-RVI3 U6500-004-PVL2 U6500-004-PVI3

*Other jacket colors available upon request with leadtime and minimum order quantities

10 purenetcable.com
Performance Characteristics
Meet or exceed TIA-568-C.2 Category 6 requirements
Return Loss (RL) Minimum Insertion Loss (Attenuation) Maximum
dB/100 m dB/100 m
Frequency² TIA-568-C.2 U6500-R U6500-P TIA-568-C.2 U6500-R U6500-P
(MHz) Standard Typical Typical Standard Typical Typical
1 20.0 26.65 27.52 2.0 1.75 1.67
4 23.0 34.63 30.54 3.8 3.45 3.28
10 25.0 36.19 30.78 6.0 5.47 5.37
16 25.0 38.58 32.42 7.6 6.97 6.85
20 25.0 44.48 36.16 8.5 7.79 7.70
31.25 23.6 39.60 35.64 10.7 9.81 9.74
62.5 21.5 39.56 34.45 15.4 14.13 14.09
100 20.1 37.99 33.04 19.8 18.08 18.09
200 18.0 34.95 32.49 29.0 26.03 26.44
250 17.3 34.38 27.51 32.8 29.33 29.69
300 38.10 29.85 33.13 33.20
400 33.81 34.86 38.34 38.85
500 35.61 32.97 43.56 43.95

Near End Cross Talk (NEXT) Minimum Equal Level Far End Cross Talk (ELFEXT) Minimum
dB/100 m dB/100 m
Frequency² TIA-568-C.2 U6500-R U6500-P TIA-568-C.2 U6500-R U6500-P
(MHz) Standard Typical Typical Standard Typical Typical
1 74.3 94.84 88.35 67.8 92.41 88.03
4 65.3 84.54 74.40 55.8 83.86 75.90
10 59.3 77.86 71.53 47.8 78.20 70.39
16 56.2 75.98 69.46 43.7 76.86 68.13
20 54.8 73.23 69.13 41.8 74.63 65.46
31.25 51.9 70.48 62.72 37.9 72.35 61.81
62.5 47.4 65.07 60.55 31.9 71.30 58.69
100 44.3 63.12 55.10 27.8 64.88 57.71
200 39.8 58.39 54.33 21.8 60.37 49.03
250 38.3 50.62 53.58 19.8 56.90 44.99
300 52.51 49.97 48.40 38.38
400 54.01 55.13 35.33 41.00
500 46.70 64.98 42.04 32.59
²Value above 250Mhz are for informational purposes only

Technical Details
Item Unit Riser Plenum
Conductor DC Resistance Max. Ohms/100 m 9.38 9.38
Resistance Unbalance Max. % 5 5
Mutual Capacitance Max. nF/100 m 5.6 5.6
Capacitance Unbalance Max. pF/100 m 330 330
Characteristic Impedance Ohms 100 ± 15% 100 ± 15%
Propagation Delay Max. ns/100 m 536 @ 500MHz 536 @ 500MHz
Delay Skew Max. ns 45 45
Nominal Velocity of Propagation % 67 70
Operating Temperature °F (°C) -4 to +140 (-20 to +60) -4 to +140 (-20 to +60)
Storage Temperature °F (°C) -4 to +176 (-20 to +80) -4 to +176 (-20 to +80)
Bending Radius 4 x Cable diameter 4 x Cable diameter
Type 1 kft (305 m) Reelex II Reelex II
Packaging: Weight lb/kft (kg/km) 17 (25) 20 (30)
Packages Per Pallet 36 36
Conductors 23 AWG, Solid copper 23 AWG, Solid copper
Materials: Insulation in (mm) 0.035 (0.90), HDPE 0.034 (0.86), FEP
Jacket in (mm) 0.193 (4.9), PVC 0.173 (4.4), LS-PVC (Plenum Rated)
Safety UL 444, UL 1666 UL 444, NFPA 262
Approvals:
Performance TIA-568-C.2 “Balanced Twisted-Pair Telecommunications Cabling and Components Standards”

purenetcable.com 11
Category 5e 350MHz UTP Cable
U5350-004-xxxx

Conductor

Insulation (HDPE/FEP)
Rip Cord

Twisted Pair

Jacket (PVC)

Description
• UL Listed CMR and CMP
• UL and ETL Verified
• Supports Fast Ethernet, Gigabit Ethernet, 155 Mbps ATM, Multimedia
• Simplified structured cabling solution preserves long-term network investment
• Every master reel is tested for electrical performance compliance
• Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m)
• Lightweight, easy-pull Reelex packaging eases installation
• RoHS compliant

Application
• Horizontal Distribution & Backbone Cabling
• 155Mbps ATM, 100Mbps TP-PMD
• 10/100/1000BASE-T (IEEE 802.3)
• ISDN, ADSL
• PoE, PoE+ (IEEE 802.3af, IEEE 802.3at)

Part Numbers
Description
Enhanced Category 5e UTP Cable, 4-Pair, Enhanced Category 5e UTP Cable, 4-Pair,
Jacket Color Riser Rated Plenum Rated
Blue U5350-004-RBL2 U5350-004-PBL2
White U5350-004-RWH2 U5350-004-PWH2
Grey U5350-004-RGY2 U5350-004-PGY2
Black U5350-004-RBK2 U5350-004-PBK2
Yellow U5350-004-RYL2 U5350-004-PYL2
Green U5350-004-RGN2 U5350-004-PGN2
Red U5350-004-RRD2 U5350-004-PRD2
Orange U5350-004-ROR2 U5350-004-POR2
Violet U5350-004-RVI2 U5350-004-PVI2

12 purenetcable.com
Performance Characteristics
Meet or exceed TIA-568-C.2 Category 5e requirements
Return Loss (RL) Minimum Insertion Loss (Attenuation) Maximum
dB/100 m dB/100 m
Frequency3 TIA-568-C.2 U5350-R U5350-P TIA-568-C.2 U5350-R U5350-P
(MHz) Standard Typical Typical Standard Typical Typical
1 20.0 27.30 27.23 2.0 1.88 1.85
4 23.0 32.46 30.89 4.1 3.75 3.71
10 25.0 35.73 35.47 6.5 6.02 5.97
16 25.0 37.29 36.36 8.2 7.66 7.60
20 25.0 38.84 36.42 9.3 8.60 8.53
31.25 23.6 35.93 34.67 11.7 10.82 10.74
62.5 21.5 33.22 33.37 17.0 15.55 15.47
100 20.1 29.53 31.27 22.0 19.84 19.84
200 29.28 30.39 25.44 21.34
300 28.50 29.50 26.00 22.00
350 27.78 28.26 26.81 22.47

Near End Cross Talk (NEXT) Minimum Equal Level Far End Cross Talk (ELFEXT) Minimum
dB/100 m dB/100 m
Frequency3 TIA-568-C.2 U5350-R U5350-P TIA-568-C.2 U5350-R U5350-P
(MHz) Standard Typical Typical Standard Typical Typical
1 65.3 74.32 74.20 63.8 76.96 71.71
4 56.3 72.68 69.65 51.8 68.53 70.38
10 50.3 63.04 62.56 43.8 62.59 65.12
16 47.2 62.02 57.86 39.7 58.18 57.53
20 45.8 57.67 55.20 37.8 57.85 56.97
31.25 42.9 56.72 53.36 33.9 54.83 54.34
62.5 38.4 56.38 52.00 27.9 52.09 49.87
100 35.3 49.38 49.24 23.8 46.60 46.49
200 38.94 41.99 43.13 45.98
300 36.00 41.95 42.50 42.00
350 35.25 41.91 42.08 41.41
3Value above 100Mhz are for informational purposes only

Technical Details
Item Unit Riser Plenum
Conductor DC Resistance Ohms/100 m 9.38 9.38
Resistance Unbalance % 5 5
Mutual Capacitance nF/100 m 5.6 5.6
Capacitance Unbalance pF/100 m 330 330
Characteristic Impedance Ohms 100 ± 15% 100 ± 15%
Propagation Delay ns/100 m 536 @ 350 MHz 536 @ 350 MHz
Delay Skew ns 45 45
Nominal Velocity of Propagation % 67 70
Operating Temperature °F (°C) -4 to +140 (-20 to +60) -4 to +140 (-20 to +60)
Storage Temperature °F (°C) -4 to +176 (-20 to +80) -4 to +176 (-20 to +80)
Bending Radius 4 x Cable diameter 4 x Cable diameter
Type 1 kft (305 m) Reelex II Reelex II
Packaging: Weight lb/kft (kg/km) 17 (25) 20 (30)
Packages Per Pallet 36 36
Conductors 24 AWG, Solid copper 24 AWG, Solid copper
Materials: Insulation in (mm) 0.035 (0.90), HDPE 0.034 (0.86), FEP
Jacket in (mm) 0.193 (4.9), PVC 0.173 (4.4), LS-PVC (Plenum Rated)
Safety UL 444, UL 1666 UL 444, NFPA 262
Approvals:
Performance ANSI/TIA-568-C.2 “Balanced Twisted-Pair Telecommunications Cabling and Components Standards”

purenetcable.com 13
RG6 Coax Cable
RG6x-x-xxx-x

RG-6/U

Jacket

Foil

Conductor

Dielectric

Braid

Jacket

Foil

Conductor

Dielectric

Braid

RG-6/Q

Description
• UL Listed CM and CMR
• Flexible braided 75 ohm coaxial drop cable
• Support analog, digital and high-bandwidth technologies
• Maintains tight tolerances to cable diameter requirements of leading connector manufacturers
• Every master reel is tested for electrical performance compliance
• RoHS compliant

Application
• HDTV, CATV and CCTV
• Two-way cable modems
• Extended bandwidth satellite service

Part Numbers
Description
RG 6 Coax Cable, RG 6 Coax Cable,
Shield/Jacket Color/Package CM (CL2) Rated CMR (CL2R) Rated
Dual Shield (60%)/Black/Reelex RG6S-S-MBK-2 RG6S-S-RBK-2
Dual Shield (60%)/White/Reelex RG6S-S-MWH-2 RG6S-S-RWH-2
Quad Shield/Black/Reelex RG6Q-S-MBK-2 RG6Q-S-RBK-2
Quad Shield/White/Reelex RG6Q-S-MWH-2 RG6Q-S-RWH-2

14 purenetcable.com
Performance Characteristics
Attenuation @68°C (20°C)
Insertion Loss (Attenuation) Insertion Loss (Attenuation) Insertion Loss (Attenuation)
Frequency Maximum Frequency Maximum Frequency Maximum
(MHz) dB/100 m (MHz) dB/100 m (MHz) dB/100 m
55 5.25 330 12.26 550 16.08
211 10 350 12.63 600 16.3
250 10.82 400 13.61 750 18.54
270 11.04 450 14.43 870 20.04
300 11.64 500 15.29 1,000 21.49

Product Construction
Structure Material RG6/U RG6/U Q
1.02±0.01 mm 1.02±0.01 mm
Inner conductor Copper Clad Steel
(18AWG) (18AWG)
Dielectric Foamed PE Nom. 4.57 mm Nom. 4.57 mm
Outer 1st shield Bonded Aluminum Foil 4.78±0.13 mm 4.78±0.13 mm
Outer 2nd shield Aluminum Braid
Outer 3rd shield Aluminum Foil None
Outer 4th shield Aluminum Braid None
Jacket 6.93±0.10 mm 7.30±0.10 mm
PVC
(Thickness) (Nom. 0.80 mm) (Nom. 0.86 mm)

Technical Details
Item Unit Riser Plenum
Conduct Resistance (Inner) Ω/km ≤102 ≤102
Conduct Resistance (DC Loop) Ω/km ≤150 ≤145
Capacitance (pF/m) pF/m 50±3 50±3
Relative Propagation Velocity % ≥82 ≥82
SRL (dB) [5MHz–1000MHz] dB 20 20
SRL (dB) [1000MHz–3000MHz] dB 15 15
Impedance Ω 75±3 75±3
Operating Temperature °F °C -4 to +140 (-20 to 60) -4 to +140 (-20 to 60)
Type 1 kft (305 m) Reelex II Reelex II
Packaging Weight lb/kft (kg/km) 29 (43) 34 (51)
Packages Per Pallet 20 20
Approvals Safety UL 444, UL 1685 UL 444, UL 1685

purenetcable.com 15
PureLink™ Warranty | Terms and Conditions
WARRANTY WARRANTY EXCLUSIONS
The PureLink™ Warranty provides that any indoor PureNet Category 5e, 6 and The PureLink Warranty does not cover:
6A premises copper cable will conform substantially to the ANSI/TIA-568
1. The installation and maintenance of any other non-performing portions
series industry specifications in force at the time of purchase for a period of
of the Cabling Subsystem(s);
(i) twenty‑five (25) years from the delivery date for any approved connectivity
manufacturer (the “PureLink Warranty” which is issued and administered by 2. PureNet products not specifically designated as being eligible for the
Essex Group, Inc. in association with PureNet category cable). PureLink Warranty coverage;
3. PureNet products not supplied directly by Essex Group, Inc. or obtained
SCOPE through unapproved channels;
The PureLink Warranty covers the Cabling Subsystem(s) of the network as 4. PureNet products which were falsely represented as being in compliance
defined by the ANSI/TIA-568, which includes the qualifying premises cable with the PureLink Warranty registration requirements and procedures;
and connecting hardware. The PureLink Warranty does not cover other 5. PureNet products that are exposed to moisture, liquids (such as paint),
elements of the cabling, such as patch cords and workstation cords. or water;
6. Defects resulting from environmental or third party materials, including
QUALIFICATION but not limited to work areas, patching or equipment cords, or from
To qualify for the PureLink Warranty, customer must meet the following moves, additions and changes by parties other than a Certified
conditions: Contractor;
1. The connectivity components used in the network must be supplied by one 7. Defects resulting from a non-compliant or improper system design,
or more of the approved connectivity manufacturers AND each component installation, use, repair, or any system alterations, misuse, neglect,
must be manufactured, tested, and independently verified by UL, ITS/ accident or abuse; or
ETL, or any approved independent testing agency to meet the ANSI/ 8. Damage caused by persons, machinery, foreign objects, animals,
TIA-568 series industry standard in force at the time of purchase. The chemicals, acts of God, or by other means that are beyond normal use.
approved connectivity manufacturers are subject to change at any time.
Please contact Essex Group,Inc. at purelinkwarranty@purenetcable.com ADMINISTRATION
for an up-to-date list. The companies currently recognized as approved
connectivity manufacturers are: Warranty applications will be approved or disapproved with a response sent to
the applicant. Warranty applications and supporting documentation may be
• AllenTel • Legrand/ • Superior Modular
sent using one of the following below:
• Belden IBDN Ortronics (OCC)
• Leviton • Systimax/ 1. PureLink Warranty
• Dynacom
CommScope (Administered by Essex Group, Inc.)
• Hellermann • Molex
Attn; J. Krauskopf
Tyton • Panduit • Uniprise/
1601 Wall Street
• Hubbell • Signamax CommScope
Fort Wayne, IN 46802
• Siemon 2. E-mail: purelinkwarranty@purenetcable.com
2. The network system must be designed and installed by “BICSI Certified”
or other designers and installers approved for the PureLink Warranty; CLAIMS, EXCLUSIVE REMEDIES AND DISCLAIMERS
3. Each link in the network must be field tested in accordance with the The validity of any warranty claim shall be determined by Essex Group, Inc.
ANSI/TIA-568 series industry standard in force at the time of purchase in its sole discretion. A claim will be reviewed for validity only if all of the
AND the installed network links must have passed all ANSI/TIA-568 following are satisfied:
requirements;
1. 1. Reported in writing to Essex Group, Inc. within ten (10) days of date
4. The PureLink Warranty application form must be properly completed of nonconformity discovery;
and submitted to Essex Group, Inc. within 10 days of installation
completion; 2. All installation records are provided to Essex Group, Inc. (original
network installation design prints, test results, warranty registration)
5. Copies of all test reports must be submitted along with the warranty evidence of original test, including reports showing compliance to all
application form and the Bill of Materials (BOM) to Essex Group, Inc. applicable ANSI/TIA‑568 requirements;
and be kept on file by the customer for submission to Essex Group, Inc.
in the event of a warranty claim. Data must be submitted in the original 3. Copies of all original receipts for materials and labor from the date of
native file format of the tester (see below) used in the installation and initial installation are provided to Essex Group, Inc.; and
submitted via CD or electronically with the warranty application form. 4. Essex Group, Inc. has full and open access to inspect and evaluate the
Text or spreadsheet files will not be accepted; products and installation site.
6. The following field testers are acceptable for use to certify installations If a warranty claim is determined by Essex Group, Inc. in its sole discretion to
for warranty coverage: be valid, as customer’s sole and exclusive remedy, Essex Group, Inc. will, at its
option and using Certified Contractor(s) of its choosing, replace or repair the
Fluke Networks: Ideal Industries: non-compliant qualifying components of the Cabling Subsystem(s) and cover
• DTX 1200/1800/5000 • LanTEK® II Series Cable reasonable cost of labor to affect necessary work. If the customer provides a
• Versiv Certifier quote from a Certified Contractor of its choosing, Essex Group, Inc., in its sole
discretion, may alternatively elect to allow such Certified Contractor to affect
Psiber Data Systems: the warranty repair and reimburse the customer for reasonable and customary
• WireXpert labor costs, provided prior written approval is obtained from Essex Group, Inc.
Utilized test equipment must have valid certificate of calibration at time of for proposed materials and labor. If the cause of any error is determined to be
testing. The acceptable field testers are subject to change at any time. Please improper installation, maintenance or third party repair, the customer may
contact Essex Group, Inc. at purelinkwarranty@purenetcable.com for an be referred back to the appropriate contractor or third party for support. The
up‑to‑date list; and remedies of the customer for non-compliant products shall be strictly limited to
those provided herein to the exclusion of any and all other remedies including,
7. A registered warranty certificate has been issued to the customer for the without limitation, claims for incidental or consequential damages.
PureLink Warranty.
EXCEPT WITH RESPECT TO THE SPECIFIC WARRANTIES SET FORTH HEREIN, ESSEX GROUP,
The PureLink Warranty will be void unless the system is maintained INC. MAKES NO OTHER WARRANTIES WHATSOEVER, EXPRESS OR IMPLIED, REGARDING
in accordance with industry standards and no changes are made after THE PRODUCTS, INSTALLATION OR PERFORMANCE OF ITS OBLIGATIONS HEREUNDER, AND
warranty issuance and acceptance date, unless written consent is granted SPECIFICALLY DISCLAIMS ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
by Essex Group, Inc. in association with PureNet category cable. PARTICULAR PURPOSE.

All information, content, data, specifications, packaging and part numbers detailed herein are subject to change.
purenetcable.com For the most up to date information, please visit purenetcable.com Rev 01/18
Purenet®, In-Stock and Ready to Ship!
We Have a Convenient Stocking Location Near You.
Contact Us Today!

13 WA ME

MT ND
VT
OR MN NH

ID 14 NY MA
SD WI
CT
WY MI RI
01 03
IA PA
NJ
NE 05
OH DE
NV
UT 02 IL IN MD
WV DC
CA CO VA
KS MO KY

NC
12
10 TN
AZ
OK
11 AR 09 SC
NM 07

GA
MS AL
04

TX
06 LA

FL
MX 08

15

Stocking Locations

01 Chicago, IL 05 Fort Wayne, IN 09 McDonough, GA 13 Portland, OR


02 Denver, CO 06 Houston, TX 10 Memphis, TN 14 Simcoe, ON
03 Edison, NJ 07 Lubbock, TX 11 Tempe, AZ 15 Torreon, MX
04 El Paso, TX 08 McAllen, TX 12 Ontario, CA

purenetcable.com
1601 Wall Street
Fort Wayne, Indiana 46802
260.461.4065

purenetcable.com

LIT 004-E
01/18