TWU 28_05 Italfer Fatigue

Fastening Systems - Testing


Von / From: TPFkc
TWU-TPF-28/05 Datum / Date: 04.01.2006
New Business & Technology Seite / Page: 43 / 72

9.5 Plots / Diagramme:


9.5.1 M20 Tension

relevant failure:
HTD-1000 M20 rods with center rings
thread
Pulsating Tensile Stress run out
Results presented in Wöhlernet mean value
Eurocode 1993-1-1 (36*)
1000.0

2
100.0

log stress amplitude [N/mm ]


10.0
1.E+03 1.E+04 1.E+05 1.E+06 1.E+07 1.E+08 1.E+09
log Cycle [n]

All rights reserved. No extract either may be reproduced or published without our permission in writing. Please observe the information security directive!
© Hilti Aktiengesellschaft, FL-9494 Schaan, Principality of Liechtenstein Issued by: Library Technical Center