DEVELOPMENT CONSTRUCTIONS LTD.

PLATE LOAD TEST (IS 1888-1982)

PROJECT CLIENT LOCATION TEST NO. Co-ordinate


N E
2x660MW Maitree STPP BHEL Rampal, Bagerhat PLT-01
2252 1481
Pressure (kPa) Load Settlement Curve Time History of Load and Settlement
0 50 100 150 200 250 300 350
0 350 50.00
Load Cycle Load History
Settlement (mm)

Settlement History
45.00
5
300
40.00
10
250 35.00

15
30.00
200

20 25.00

150
20.00
25

100 15.00
30
10.00
50
35 Pressure (kPa)

Settlement (mm)
5.00

40 0 0.00
0 500 1000 1500 2000 2500 3000 3500 4000
Time (min)

45 Test Depth (m): 0.6m


Plate Size (cm): 60x60x2.5
Jack Diameter (cm): 42.00
50 Max Pressure (kPa): 300.00
Max Settlement (mm): 46.53

TEST PERFORMED BY PREPARED BY DATE


Md. Saiful Islam Engr. Md. Roknuz Zaman 19-Jul-16