List of Burnt/Obsolete/Dismantled/Defective Transformers as on dated 07/12/2019

Abnormal
Sl. Name of Capacit Make YOM Date of Behaviour(humming
no. GSS
Rating
y outage Last Repair sound/Last DGA report Physical Condition Remarks
etc)

Muzaffarpur Zone
132/33 KV 20 MVA Kanohar 2001 Defects in HV winding Kept on Transformer has been
132/33 KV plinth(missing parts) brought from GSS Nawada.
1 Shahpur
patori This transformer has been
132/33 KV 20 MVA
It is in dismanlte
CGL 1986 DefectiveTransformer brought from GSS
condition Masaurhi.

Transformer has been


tripped on OTI when It is in dismanlte Transformer has been
132/33 KV 20 MVA Telk NA brought from GSS sitamarhi
load increased above condition
5MW. in 2013

It is in dismanlte Transformer has been


2 132/33 KV 132/33 KV 20 MVA Telk NA IR value is low
condition
brought from GSS sitamarhi
Dhaka in 2015.

Transformer has been


132/33 KV 20 MVA
Core to channel IR test It is in dismanlte
Indotech 2005 brought from GSS Mohania
value is zero. condition in 2015.

To met load demand this


transformer was Replaced
132/33 KV 20 MVA
In running condition at Normal and in
Telk 1975 NA by 50mva bharat bijlee
the time of dismantle Dismantle condition
make transformer in june
2014
3 132/33 KV
Saharsa
132/33 KV
3
Saharsa To met load demand this
132/33 KV 20 MVA
In running condition at Normal and in transformer was Replaced
Telk 1977 NA the time of dismantle Dismantle condition by 50mva Kanohar make
transformer in April 2015
(i) Filtration &
leakage
attended in
2001 by M/S
DEVCON.(ii) This transformer was a
Filtration & Got Burnt in repaired one and was in
Gasket Burnt Transformer
4 132/33 KV 132/33 KV 20 MVA Telk NA 05.06.16 05/06/2016 and having and in Dismantle service since
Kataiya replacement in hole in lower side of condition 30/04/1969 .This Burnt
11/2009 by main tank Transformer was replaced
M/S Rishab by 50 mva transformer
and in 05/2015
by M/S
Santhala
respectively Tripped on PRV relay at This old Transformer has
132/33 KV 132/33 KV the time of charging.PRV it is in Dismanlte been brought from GSS
5 10 MVA T&R 2005 NA was not in proper Supaul.This transformer
Triveniganj 04.02.17 condition
condition,Humming replaced with 20MVA CGL
Sound. make Power Transformer .

Oil leakege, cooling This transformer comes


Positive DGA Test but fans
6 132/33 KV 132/33 KV 20 MVA NGEF 1977 NA NA BDV, PPM,IR test results are not working from Betia GSS but failed to
EKMA and in Dismantle commissioned at GSS
are negative condition Ekma.

Removed from plinth


132/33 KV 132/33 KV 12.5
7 Romania NA NA NA NA Dismantle condition because of augmentation
Chhapra MVA
with 50 mva transformer

Last Continuous oil


overhauling abnormal humming leakage and cooling Very old and laying outside
132/33 KV 20 MVA HEL 1967 2016 sound,violate IR & DGA
done on value. system was not of switchyard
26/04/2008 healthy
132/33 KV
8
Pandaul
132/33 KV
8
Pandaul
Last Continuous oil
abnormal humming
132/33 KV 20 MVA HEL 1966 2016 overhauling sound,violate IR & DGA leakage and cooling Very old ,defective and
done on system was not laying on plinth
04/03/2006 value healthy

Burnt Transformer
132/33 KV 20 MVA Telk NA NA NA NA and in Dismantle Very Old
condition

132/33 KV 132/33 KV Very old, Obsolete defective and


10 20 MVA NGEF NA NA NA
Hajipur condition dismantled

Bhagalpur Zone

Transformer is totally
132/33KV 132/33 KV 20 MVA
12 Kahalgaon NA NA NA NA NA burnt and dismentled
few year ago

132/33 KV Tan delta test between Oil leakage from main LOI has been sent to M/s
14 Banka(new 132/33 KV 50 MVA Telk 1988 16.09.18 Overhauling HV & LV has shown tank and radiator TELK for inspection of
) error transformer

132/33 KV 132/33 KV 20 MVA Dec 2016 Dismantled but not This transformer replaced
15 NA 2001 Not repaired Normal with 50MVA Power
Lakhisarai defective
Transformer in dec 2016.
Only main body lying
It Came from TSD
on ground(no any
16 132/33 KV 132/33 KV 12.5 Romania 1966 NA NA very much rusted. radiator,conservator, Karmnasha in jan
Sheikhpura MVA bushing etd 2005.after inspection it
may be declared obsolete.
available).

132/33 KV 132/33 KV 2009 Defective and Dismanteled in 2009 for


17 10 MVA NA 2001 NA NA
Jamui Dismantled augmentation by 20 mva

Transformer lying idle


132/33 KV 20 MVA
Fire caught in one side of radiator
NA 2013 13/07/2014 Not repaired 13/07/2014. dismentled since 2014 in switchyard of
sultanganj.
132/33 KV
18
Sultanganj
Transformer dismentled
132/33 KV 20 MVA NA 1989 NA Not repaired Transformer declared Defective and and lying idle since 2014 in
defective in 2014. Dismantled
switchyard of sultanganj

R-phase HV bushing was


Transfor
bursted. After changing
19 132/33 KV 132/33 KV 10 MVA mers & 2005 07/06/2017 NA Defective bushing and oil filtration,
Balia Rectifiers( Oil testing was done but it
India) ltd. didn't pass

Defective since
132/33 KV 10 MVA IMP 2000 19/12/2008 NA NA Defective 19/12/2008 due to
sparking and heavy oil
leakage from tap changer

132/33 KV
20 Khagaria
132/33 KV
20 Khagaria Defective since
19/08/2018 Oil seapage from 19/08/2018 due to
132/33 KV 20 MVA HEL 1967 NA Defective bursting of y-phase bushing
radiator of HV side and heavy oil
thrown out in switchyard.

said transformer was not


21 132/33 KV 132/33 KV 10 MVA Kanohar 2001 NA NA NA Defective and erected from the begining
Manjhaul Dismantled
time of GSS

Oil leakage from


132/33 KV 132/33 KV
22 Kathihar 20 MVA ABB 2001 06.09.2008 NA Humming sound several points of main Burnt Transformer
tank

Core frame tank cover Replaced with new


got defective and in last transformer(Bharat Bijli)
132/33 KV 50 MVA ABB 2007 NA DGA test amount of Oil seapage transported from GSS
05.01.18 acytelene is beyond harnout which was
permisible limit originally from Barsoi GSS
132/33 KV
23 Purnea

132/33 KV 20 MVA GEC 1988 NA Dismantled Defective Transformer


13.01.2016

Patna Zone
BHEL M/s EMCO has suggested
Make, that defective transformer
24 132/33 KV 132/33 KV 20 MVA EMCO NA Repaired Dismantled at Banjari can be repaired
Banjari 22.08.18
repaired at their workshop in
2015 Jalgaon.

220/132/3 50MVA Jeumont


3KV
1965 Jan-14 Dismantled
schneider

220/132/3
25 3 KV Dehri- CGL Make This transformer was sent
on-Sone repaired Repaired in to M/S AVAL in feb 2017 by
220/132K
V 100MVA by M/S 1978 Jul-16 2009 by M/S w.o 24/Tech/TRZ patna
AVAL in AVAL dated 09.12.16 for repair
2009 and is currently still lying.

Transformer at workshop of M/S BHEL Jhansi.


220/132/3 During inspection at BHEL as per joint MOM of M/s BHEL Jhansi has
26 3 KV 220/132K
150MVA BHEL 2013- 04.01.2019 CRITL & BHEL workshop ,black spot flash submitted repair cost of
V 14 between the tapping coil lead no 11 of ‘W’ Phase offer Rs.57,94,430.00
Pusauli with W-Phase top lead of Tertiary coil was (exclusive of GST) .
found Oil spill off from PRV of the
Transformer due to which
Service R phase top and bottom
Engineer binding, inner insulation
visited the site has been carbonised and
and suggested winding spacer block has
132/33 KV 20 MVA
DGA report showing
AREVA 2009 that No oil leakage been displaced from its
21.07.2018 abnormal value
transformer original position.Service
has to be sent engineer of M/S GE T&D
220/132/3 at inspected defective
27 3 KV manufacturer transformer and
Biharsharif recommended for repair at
their workshop.
Transformer dismantled on
220/132K Dismantled and dt 19/04/2014 and already
V 150MVA CGL 1985 NA Not repaired
defective devaluated to transmission
circle store Biharshariff
Burnt Transformer and it
132/33 KV 132/33 KV
28 20 MVA NGEF 1991 NA NA Dismantled has been dismantled since
Nawada
long

132/33 KV 50 MVA GEC 1987 07/08/2018 Dismantled Defective


132/33 KV
29 Jakkanpur
132/33 KV 50 MVA
10/02/2019
GEC 1988 Dismantled Defective

132/33 KV 15 MVA
Out of service very long.
ELIN 1955 Dismantled
May be declared as scrap

132/33 KV
30 Chandauti
Name Main body only,accessories
132/33 KV plate not NA NA NA NA Dismantled not available(unseviceable
available since long)

It was dismantled in year


2013.Now it is not in hope
to bring back in service due
132/33 KV 132/33 KV Jeumont
31 50 MVA schneider NA NA NA Dismantled to outage since 2013.It may
Bodhgaya be checked by CRITL wing
to declare wheather it is
serviceable or scrap.

Total no. of Defective Power Transformer 41