Extraction sieves are mounted with two different nozzle types:
1. The original type supplied by Larsson, 14mm ‐ 90° (75°) spraying angle, flowrate 320 liter/h at 0,7bar
2. No name, no data type (14mm with poor performance about 45° spraying angle) flowrate 250
liter/h at 0,7bar
Poor water distribution add less wash water on the extraction sieves as well
Not impressing to see only a few “Larsson nozzles”, but mainly “no name nozzles” are mounted in the
extraction sieves. Furthermore, several nozzle mountings are blinded.
Both the “no name nozzles” and the blinded nozzles reduces the original design amount of wash water
in the extractors. However, I suppose this is no problem at this time with only about 50% of maximum
extraction capacity is required.
In the future, when full capacity is required, I recommend mounting all nozzles as “Larsson type”,
described above, and full amount of nozzles (48 pcs in each extraction unit)