SAYS Ce |
SENSO\))) 7!) FIELDLOGGER
INTRODUCTION
FieldLogger isa versatile, powerful and yet cost efective data
logaee handling analog, digital and other typos of variables with
high resolution and speed. It isa high performance and high
connectivity equipmentand yet easy toconfigureandoperate.
Ithas 8 configurable analog inputs that can read thermocouples,
Pri, P1000, voltage and current signals. It also has 2 relay
outputs and # digital por individually configurable as inputs or
outputs.
Up to 128 mathematical channels. can be used to perform
‘operations onthe measured values. Upto 32 alarm events can be
detected, allowing output activations, e-mais and SNMP traps
sending,
Its RS485 interface can operate asa Modbus RTU master or slave. As
a master itcan read and log up to 64 external channels. I has a
10/100 Mbps Ethernet interface that alows for access through @
browser (HTTP), FTP (client and server), e-mails sending (SMTP),
SNMP and ModbusTCP.
FieldLogger has one USBinterface tobe connected toa computer
(for configuration, monitoring and data download) and another
USB port for plugging a lash diver for data retrieval. The 512k
Jogging basic memory is used to store data and it can be geatly
expanded withan sD card
{An exclusive color HMl can be attached or remotely installed for
local indication or configuration. A user friendly configurator
software can be accessed by Ethernet, USB or RS485 and also
provides means for on-ine monitoring loggee data cownloading
andexportingto spreadsheets and otherformats.
Thermocouple } “120 t0 1000°C (-184 to 1832°F)
‘Thermocouple K —__-130%0 1372°C (-20210 250167)
‘ThermacoupleT “130 t0 400°C (-202 10 752°F)
Thermocouple E -130 t0 780°C (-202 t0 1436)
“Tnermacouple N -130t0 1300°C (202t0 2372°F)
Thermocouple R 2010 1768°C (68103214.4°F)
Thermocouple S 2010 1768°C (68t0.3214,4°F)
Thermocouple 8 10010 1820°C (21203308 "F)
Px109 -200 0 850°C (-32810 1562 °F)
Pr 1000 200 10 850°C (-328 t01562°F)
Linear 0 t0 20 mA Configurable
Lingar 4t0 20 mA, Configurable
Linear 0020 mv Configurable
Linear 0 t0 50 mv. Configurable
Linear 0060 mv Configurable
Unear-20 t0 20m Configurable
Lincs: 0t0 5 configurable
Linear 0 to 10V Configurable
SENSOVANT.
-Sunivenalanaloginputcharnels:
~Thermocouples,V,mV, mA, Pt1Odand 11000;
-Readingandlogaingratesof upto 1000'secon:
-24bicA/D conversion resolution.
+ Bdigita YOs(individualy configuredasinputor output)
+ 2relayoutputs{NO,NCand common).
+ RS485 interface (Modbus masterorsiave).
~ When acting as a master can read up to 64 registers from other
slaves
= Registers read can be used in logging, alarms or mathematical
operations
+24Vdcoutputto power uptoeight 420mA transmitters
«Ethernetinterface with alotef services avaiable:
-Sendsalarm warning e-mails(SMTP);
-Provides web pages with channeisand status information (HTTP)
Allows logged data downioadviaFTP (cientand server);
~ Accesses status and channels values through network
‘management oftware (SNMP and traps)
= Allows Mosibus comunication by ethernet interface (Modbus
Tc?)
USB- device interface for configuring monitoring and download.
US8-hostinterfaceforloggeddataretievalthrouch a USBflash dive.
sbpto32configurable alarms
‘Alarmactionscanirelude:
Activating relays
Activating cigital outputs
-E-malssendingtomultipereceivers;
-SencingSNMP traps:
-Starting and/orstoppingloggings
+Upto 128 virtual channels.
~ Basic mathematical functions to be applied on other channel:
sum, subtraction, multiplication, division, logic (AND, OR and
exclusive OR square rootend power.
+24Vdcoutputfor powering upto eight 4-20 mA transmitters.
-AC power (1000 240Voc}
-DC Power (190 30Vd) optional 2011).
«Detachable human-machineinterface optional).
-KeypadandcolorTFTQVGAdisplay:
-RS485 communication with FieldLogget
sloggings:
Upto 100.channelscanbelogged ataconfigurablerate
Data download through the configuration software or through
thefreely distributed download DLL
‘comercial@sensovant.com
ge Ee
or gence Fa “AI3Se ee
SENSO\)) 1) FIELDLocGER =)
+ Power:
100 to 240 Vac, 50/60 Hz
‘Consumption: 8VA (Max)
‘+ Environmental conditions:
‘Operating temperature: 0 t0 50°C
Relative humidity: 80 6 up to 30°C. For temperatures higher than
30°C, dicrease 39% for'C
‘Altitude < 2000 m
Protection: 1°20,
Accuracy
‘Thermocouples, K,T,Eand N:0.2 % of thespon #1 °C.
“Thermocouples, S and B:0.2% of the span + 3°C.
1100, Pt1000, 0-20 mA, 4-20mA, 0-20 mY, 0-50 mi, 0-60m¥, -
20-20 mi, 0-5 Vand 0-10 0.15 9 of the span.
‘+ Analog channels input impedance:
‘Thermocouples / Pt109 / Pt1000 / mv: > 2 M0
mA: 150+1.5V
veliMa,
+ Excitation curre
11008: 360 WA;Pt1000s: 320 uA
Maximum Pt100/ Pt1000 compensated cable resistance: 40
Digital input
Logic level0": from 0 10 0.8 Ve
Logic level“1": From 2 to 30Vde
Maximum input voltage: 30 Vdc
Input current @ 30Vdc (tipical): 3 mA
Digital ourputs:
Maximum output voltage: 30Vde
Maximum ousput current:200 mA,
Maximum relay current: 3 A @ 250 Vac;3 A @30Vde
Configurable logaing rate, with logging intervals from 1 ms to 24
hours
Maximum channel amount allowed to be logged: 100
Supported Modbus commands:
Read Cot Status (01h)
Read Holding Registers (03h)
Write Single Col (05h)
Write Single Register (06h)
‘Write Multiple Registers (OFh)
Maximum TCP simultaneous connections: 10
‘Maximum UDP simultaneous connections: 10,
FTP (FieleLogger as a server):
Supported mode: passive
Standard: UNIX
‘Maximum simutaneous connections: 1
SENSOVANT
a ea
‘An intuitive configuration software goes along with the equipment,
allowing an easy corfiguraton due to its wizard-like step-by-step
system, Users can save the configuration in files and load it at a later
time. Communicationwith the equipmentcan bedone through USB,
5485 oreven Ethernet (Modbus TCF) interface.
Besides configuring, it also allows to view the configured channels,
alarms state and a lot more status information, it stil lows logged
data download and export them to several known formats.
Compatible with Windows XPVistaand7.
mw peak ®
=e
ajo TES
m0 a
aly
pomeresalGissnsovert.com,