0 INTRODUCTION
Jar testing is a method of simulating a full-scale water treatment process,
providing system operators a reasonable idea of the way a treatment chemical will
behave and operate with a particular type of raw water. Because it mimics full-scale
operation, system operators can use jar testing to help determine which treatment
chemical will work best with their system’s raw water using the optimal chemical
dosages.
In many plants, changing water characteristics require the operator to adjust
coagulant dosages at intervals to achieve optimal coagulation. Different dosages of
coagulants are tested using a jar test, which mimics the conditions found in the
treatment plant.
Jar testing entails adjusting the amount of treatment chemicals and the
sequence in which they are added to samples of raw water held in jars or beakers.
The sample is then stirred so that the formation, development, and settlement of floc
can be watched just as it would be in the full-scale treatment plant. (Floc forms
when treatment chemicals react with material in the raw water and clump together.)
The operator then performs a series of tests to compare the effects of different
amounts of flocculation agents at different pH values to determine the right size floc
for a particular plant.
Benefits of jar testing are:-
a. Better finished water quality
b. Longer filter runs
c. Overall prolonged filter life
d. Lower chemical costs
2.0 OBJECTIVE
To determine the optimal coagulant dose which will produce the highest removal
of a given water turbidity.
4.0 THEORY
Raw water and wastewater are normally turbid containing solid particles of
varying sizes. Particles with sizes greater than 50 µm settle fairly rapidly. The
settling velocities of colloidal particles of sizes less than 50 µm are very slow. Thus,
these particles are encouraged to collide leading to coalescence of particle to form
flocs particles, which are bigger and heavier. These particles will have higher
settling velocities and easily settle out.
Colloidal particles do not agglomerate by itself due to the presence of
repulsive surface forces. A process is needed to suppress these forces so as to allow
flocs formation. This process is called coagulation process. It is actually the
addiction of chemical coagulant to the raw water or wastewater. Coagulant that
normally used are salts of aluminium namely aluminium sulphate and ferric salts
namely ferrous sulphate and ferric chloride.
The next process that follows the coagulation process is flocculation. It is the
process that promotes particles collision due to gentle agitation resulting in
agglomeration of smaller non-settleable particles into flocs (bigger particles) which
settles easily to produce clarified water. Addition of coagulant aid such as synthetic
polymer will accelerate settling.
3. The prepared wastewater is placed from (1) into six (6) different beakers
(Plexiglas graduated beakers) with one litre each.
9. After the stirring period is over, the stirrer is stopped and the flocks are
allowed to settle for about 5 minutes.
10. 500 mL of settled water is separated out into another beaker
11. The temperature, pH and turbidity of the clarified water is determined.
JAR No 1 2 3 4 5 6
Agitate 23 23 23 23 23 23
(minute)
Fast (rpm) 80 80 80 80 80 80
Slow (rpm) 30 30 30 30 30 30
Turbidity 1 3 8 3 2 45
(NTU)
Floc formation Fine Fine Very fine Very fine Very fine None
(final 10 (Size C) (Size C) (Size B) (Size B) (Size B)
minutes)*
* Floc formation can be recorded by referring to the measurement scale as provided in lab sheet.
Data analysis
a. Compare the level of turbidity in each sample.
Turbidity is a measure of the degree to which the water loses its transparency
due to the presence of suspended particulates. The more total suspended solids
in the water, the murkier it seems and the higher the turbidity.
JAR No 1 2 3 4 5 6
Turbidity 1 3 8 3 2 45
(NTU)
From the results as above, it can be seen that sample 6 which acts as a control
has the highest turbidity of 45 NTU whereas for the other 5 samples which was
added with coagulant of different dosage have varies turbidity. Sample 3 has
the highest among the 5 samples while sample 2 and sample 4 have the same
turbidity. The lowest turbidity goes to sample 1 which only result as 1 NTU.
The turbidity of the samples are affected by the flocs content in the sample.
However, the results might not be as accurate as the wastewater used was
taken from the FKAAS lake which its contamination may be affected due to
rain just shortly before it was obtained. Surface water plant is susceptible to
sudden changes in water quality.
b. With the aid of a graph, show the relationship between pH and turbidity with
respect to coagulant dosage.
Graph of Turbidity vs pH
9
8
7
Turbidity (NTU)
6
5
4
3
2
1
0
4.15 4.2 4.25 4.3 4.35 4.4
pH
4.28
4.26
4.24
4.22
4.2
4.18
0 1 2 3 4 5 6
Coagulant Dosage (mg/L)
6
5
4
3
2
1
0
0 1 2 3 4 5 6
Coagulant Dosage (mg/L)
c. From the graph, get the optimum value for pH and coagulant dose of the
coagulant process.
From the graph in question 2, the optimum value for pH and coagulant dose are
4.36 and 1mg/L respectively. However, the results may not be accepted as the
graph supposed to be U-shape rather than bell shape. Hence it is shown that the
results obtained is not accurate. This is due to error such as human and random
error.
d. Explain the implications of using different dosage of aluminium sulphate in
the treatment process.
Finely dispersed suspended and colloidal particles producing turbidity
and color of the water cannot be removed sufficiently by the ordinary
sedimentation process. Adding a coagulant with mixing and stirring
the water causes the formation of settleable particles. These flocs are large
enough to settle rapidly under the influence of gravity, and may be removed
from suspension by filtration.
Alum was found to be effective coagulant in reducing solids, organics
and nutrients in the dairy industry effluent to reuse it in irrigation. In terms of
turbidity the process of increase in turbidity removal can be observed by
increment of coagulant concentration, although the removal efficiency is almost
steady due to alum dosage increment in high concentration of coagulant.
8.0 DISCUSSION
The properties of iron with respect to forming large complexes, dose, and pH
curves are similar to those of alum. In the presence of alkalinity is:
For the mechanism without alkalinity the reaction will be presence as follow:
3. Name 3 types of acid and base which are suitable for pH neutralization.
a) Acid: sulfuric acid, ferum chloride, hydrochloric acid and tartaric acid.
b) Base: sodium hydroxide, magnesium oxide, hydrogen chloride and
potassium hydroxide.
5. In what way the dosage of aluminium sulphate in the treatment process can
be reduced?
By using coagulant aids such as lime and bentonite.
6. Instead of Al2(SO4)3, name another three coagulants that can be best used
as coagulant aid.
i. Bentonite (clay)
ii. Calcium carbonate (CaCO3)
iii. Sodium silicate (Na2SiO3)
9.0 RECOMMENDATION
To obtain more accurate and precise results, make sure wastewater source
obtained were not taken right after weather changes such as rain because
surface water plants are susceptible to sudden changes in water quality thus
affect the results.
Make sure gloves are worn to avoid fingerprints on turbidimeter sample
cells which will affect turbidity readings.
Avoid air bubble in pipette when measuring alum dose.
Use distilled water as control before testing turbidity for every samples.
10.0 CONCLUSION
In conclusion, the objective to determine the optimal coagulant dose which
will produce the highest removal of a given water turbidity of the experiment is
achieved. The optimum value of pH and coagulant dose are 4.6 and 1mg/L
respectively.
Theoretically, adding coagulant such as alum does help to reduce the turbidity
of the wastewater until a certain point. However, the results obtained in our
experiment did not show a positive results due to few avoidable errors. For instance,
weather factor as the rain affected the contamination of the wastewater hence the
results were affected as well and not as desired. This is due to surface water plants
tend to treat water with a high turbidity which is susceptible to sudden changes in
water quality.
In a nut shell, jar testing is a pilot-scale test of the treatment chemicals used
in a particular water plant. It simulates the coagulation/flocculation process in a
water treatment plant and helps operators determine if they are using the right
amount of treatment chemicals, and, thus, improves the plant’s performance.
11.0 REFERENCES
Principle of Environment Engineering and Science, McGraw Hill 2004,
Mackenzie L.Davis and Susan J.Masten
Prentice Hall: Introduction to Environmental Engineering: Fourth edition:
McGraw Hill International Editions
12.0 APPENDIX