You are on page 1of 1

Shriji Designs & Urmila Info. Solution(JV) SECTION :- BINA-ISARWARA(KM.-986-991) PAGE NO.

Engineers & Contractors KM-987


Pise Complex,IInd Floor,27,Great Nag Road, LOP REF :- SDUI/986-991/LOP-4 01
NAGPUR - 440 003 WIND PRESSURE - 105.0kg/m²
LOCATION NO. 987/1A 987/3A 987/5A 987/7A 987/9A 987/11A 987/13A 987/15A 987/17A 987/19A 987/21A 987/23A 987/25A 987/27A
CHAINAGE (m) 987/34.63 987/106.63 987/176.63 987/244.13 987/316.13 987/388.13 987/460.13 987/532.13 987/604.13 987/676.13 987/748.13 987/817.63 987/880.63 987/943.63
SPAN 72 70 67.5 72 72 72 72 72 72 72 69.5 63 63 58.5
TRACK REFERNCE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE 3RD LINE
IMPLANTAION 2.90 2.90 2.90 2.90 3.10 3.10 3.10 2.90 2.90 2.90 2.90 2.90 2.90 3.10
FDN SIDE (FACING KTE) RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT RIGHT
TYPE OF MAST / LENGTH B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-150/9.50 B-200/9.50 B-150/9.50 B-200/9.50
REV. DEFLECTION +30 +30 +30 +30 +30 +30 +30 +30 +30 +30 +30 +30 +30 +30
TYPE OF SOIL /BEARING PRESSURE(kg/m2) FILLED UP/8000 FILLED UP/8000 FILLED UP/8000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000 BC/11000
FDN CODE / TYPE OF FOUNDATION 147/BG-7 147/BG-7 147/BG-7 147/NBC-126 250/NBC-127 147/NBC-126 250/NBC-127 147/NBC-126 147/NBC-126 147/NBC-126 147/NBC-126 147/NBC-126 147/NBC-126 374/NBC-131
STEP DISTANCE / EMB. LENGTH 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35 0.50/1.35
EXPOSURE OF FOUNDATION - - - - - - - - - - - - - -
SOIL PROFILE AT 3.0/3.5/4.0mtr 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90 0.60/0.75/0.90
VERSINE(mm) - - - - - - - - - - - - - -
CURVE (IN/OUT/TAN) TAN TAN TAN TAN TAN TAN TAN TAN TAN TAN TAN TAN TAN TAN
RADIUS OF CURVATURE(m) - - - - - - - - - - - - - -
SUPER ELEVATION
BLOCK TYPE /FDN - ACA/BCA-2 ACA/BCA-2 BWA/A-3
ANCHOR HEIGHT / SETTING DIS. - 7.06/7.35 7.06/7.35 7.06/7.35
DIRECTION - BINA KTE BINA
CATENARY / CONTACT HT (m)
ENCUMBRANCE
TOP/BOTTOM HEIGHT
BACK DISTANCE (m)
SUPER MAST STYLE
X-ARM
SUSPENSION DISTANCE(m)
CATENARY WIRE
STAGGER
CONTACT WIRE
CANTILEVER STYLE WWCR/9200
A'(m)
ST STYLE
B'(m)
DIMENSIONS
BT STYLE
C'/D'(m)
R.T/R.R.T STYLE
STEADY ARM LENGTH WCR/P/2390
SPS FOR BRACKET MTG. WCR/P/1001
DROPPER WCR/9207
JUMPER WCR/1010
TERMINATION WCR/1005
ANCHOR WCR/1006
GUY ROD ETI/OHE/P/5000
NUMBER PLATE MOUNTING ETI/OHE/G/01701
STRUCTURE BOND ETI/OHE/P/7000
CUT-IN-INSULATOR
SECTION INSULATOR
RC/AC/FEEDER SUSPN.STYLE
ISOLATOR CONNECTION WCR/9210
ISOLATOR MTG.ARRGT ETI/OHE/G/05513 SH-1
STAY INSULATOR MAKE/YEAR
BRACKET INSULATOR MAKE/YEAR
9-TONNE INSULATOR MAKE/YEAR
S.S WIRE ROPE MAKE/YEAR
CATENARY WIRE MAKE/YEAR
CONTACT WIRE MAKE/YEAR

PROJECT APPROVED IN PRINCIPLE


Railway Electrification of MALKHERI TO ISARWARA 3RD LINE
APPROVED AS CSD

FOR Shriji Designs & Urmila Info. Solution (JV) SSE/OHE/CON/WCR/BPL AEE/CON/WCR/BPL DY.CEE/CON/WCR/BPL