Technical Information

HXV - HRV
Ventilation

General description
Technical data
Accessories
V E N T I L AT I O N

HXV 5

1 General description 1.01 - 1.02

2 Technical data 2.01 - 2.02

3 Accessories 3.01 - 3.03

HRV 5

4 General description 4.01 - 4.02

5 Technical data 5.01 - 5.02

6 Accessories 6.01 - 6.01

With reservation for changes and misprints.


1 G E N E R A L D E S C R I PT I O N

General description
HXV 5
FUNCTION
HXV 5 is the perfect ventilation solution to create and maintain a healthy living
environment.
The unit is supplied as standard with a user-friendly control panel in a modern
design.

APPLICATION
HXV 5 is particularly suitable for apartments and 1 or 2 bedroom residential homes
of between 80 and 200 m2 where an air change rate of 0.5 / hour is required.

INSTALLATION
The HXV 5 compact dimensions and light weight ensure that it can be placed
instead of a standard 60 cm wide wall unit closet.

The HXV 5 flexible configuration means that it can easily be converted to left or
right hand installation.

The HXV 5 unit can be installed in a utility room with the control panel remotely
located to suit the homeowner.

CHARACTERISTICS
• Easy to operate and service
• Compact dimensions
• Variable air volume
• Built-in electric heater for supply air
• Heat exchanger frost protection
• Filter change timer with audible alarm
• Summer ambient cooling using adjustable by-pass damper
• Configurable for left or right hand installation

2 3 1 4

ILLUSTRATION OF AIR FLOW IN HXV 5


1 Fresh air intake
2 Supply air
3 Return air
4 Exhaust air

1.01
A CC E SS O R I E S 1
CONTROL PANEL
Operation of the HXV 5 is extremely user-friendly using the standard control panel.
Simply select the required air volume from one of 4 pre-sets. In addition there are
two LED’s to indicate when the unit and heating element are in operation and an
audible alarm for the filter guard. The control panel is connected to the unit using
a 12 metre RJ45 cable.

Additional functions are offered with the high end user panel which can be select-
ed as an optional accessory.

Air volume setting

ON/OFF LED for electric heating


element
ON/OFF LED for unit operation
Filter guard
(audible alarm)

PART NUMBERS

Standard model
HXV 5 unit plus standard control panel. Dantherm No. 031366

1.02
2 T EC H N I C A L D ATA

Te c h n i c a l d a t a

Heat exchanger type Cross flow heat exchanger


Efficiency % up to 70%
Max. air volume m3/h 360m3/h at 150 Pa
Power supply V/Hz 230 V/50Hz
Operating temperature range °C -20 to +50
Max power consumption with
and without electric heating element Watt 874/374
Sound level (1 meter from the cabinet) dB(A) 44*
Weight kg 36,5
Colour (cabinet and panel) RAL 9016
Protection class IP 44
Duct connection mm Ø125
Filter types F/G G3 exhaust air and G3 plus F7 supply air
Material, cabinet Hot galvanized steel
Material, control panel Polystyrene

* at max. fan speed

DIMENSIONS

All dimensions are in mm.

2.01
T EC H N I C A L D ATA 2
PERFORMANCE CURVES

Air Volume Performance Curves of HXV 5


350

300
Available Pressure Pa

250

200

150

100

50

0
0 50 100 150 200 250 300 350 400
Air Volume m3/h
E4
S4
E4=exhaust 100% air volume S4=supply 100% air volume E3
E4=exhaust 70% air volume S4=supply 70% air volume S3
E4=exhaust 50% air volume S4=supply 50% air volume E2
S2
E1=exhaust 25% air volume S1=supply 25% air volume E1
S1
Please note:
HXV 5 has four different settings for air volume, where each setting can be set between 25 and 100%.
The performance curves for max. air volume (E4; S4) shown are not the factory setting. The factory setting corresponds to approx.
70% of the stated max. air volume (E3; S3).
The performance curves E2; S2 (= 50% air volume) and E1; S1 (= 25% air volume) correspond to the factory setting for these two
air volumes.

TEMPERATURE EFFICIENCY
Supply Air Heat Recovery Efficiency of HXV 5
100

90

80

70

60
Efficiency %

50

40

30

20

10

0
0 50 100 150 200 250 300 350 400
Exhaust Air Volume m3/h

Conditions: t fresh air = 4°C, t return air = 20°C and RH return air = 50%.

2.02
3 A CC E SS O R I E S

Accessories
HIGH END CONTROL PANEL
The high end panel has the following key functions:
• 4 Variable fan speed settings
• Control of relative humidity (RH)
• Fire place function
• Ability to connect up to 5 high end panels to the unit in series
• Control of air quality (AQ) Dantherm No. 036418

FIRE PLACE FUNCTION


The fire place function is a help when e.g. the wood burning stove, fireplace or the
like is to be lit.

The function disables the exhaust air fan for 15 minutes by which the inlet fan esta-
blished an overpressure in the house.

AIR QUALITY (AQ)


The high-end control panel provides the user with the option to control both the rel-
ative humidity and air quality levels.

Air quality is maintained by entering a value of between 0 and 100 into the control
panel. An air quality value of 30-40 (100 is perfect air quality) is normally consid-
ered as a good and healthy level but it is recommended that the user establish
their own personal comfort level by monitoring and adjusting the levels over a peri-
od of time.

Once a value is entered, the HXV 5 continually automatically adjusts the air volume
to maintain the air quality to the specified value. This ensures that the unit is con-
stantly operating at the optimum level to maintain the conditions and as a result
considerable operating cost savings can be achieved when compared to the stan-
dard control panel.

LPHW HEATING COIL


A LPHW coil can be connected within the unit. This operates not via the controller,
but uses its own thermostat in conjunction with a remote sensor.
Dantherm No. 035579

3.01
A CC E SS O R I E S 3
Calculation of heat emission from the LPHW heating coil and ⌬ t

Water flow l/s


0,05
0,03
1,2 70 l/s
Air flow

1 50 l/s

0,8

Heat output (kW)


30 l/s

0,6 20 l/s

55°C
0,4
45°C

0,2 35°C
25°C
0
10 15 20 25 30 35
Temperature of air leaving the LPHW heating coil °C

Assumption: Temperature of air coming to the LPHW is 12°C.

Example:
t water, flow = 55°C, Q water = 0,05 l/s
Qair = 70 l/s
¡ ⌽ = 1 kW & tair, return = 24°C
¡ ⌬tair = 12°C

Water flow l/s


0,05
0,03
1,2

0,8
Heat output (kW)

0,6

0,4

0,2

0
0 2 4 6 8
⌬t water °C
Example:
⌽ = 1 kW
¡ ⌬twater = 5°C
¡ twater, return = 55-5 = 50°C

3.02
3 A CC E SS O R I E S

HUMIDITY CONTROLLER
A humidity sensor can be connected to the standard control panel which will switch
the unit to maximum speed when the relative humidity is above the desired level.
Dantherm No. 016361

RJ 45 CABLE
RJ45 cable, white, 12 metres, male plugs both ends, straight connection.
Dantherm No. 032985

CONDENSATION PREVENTING PLATE - WALL SUSPENSION


Prevents condensation/moisture entering the ceiling construction via ducting
holes. Dantherm No. 035484

CEILING SUSPENSION AND CONDENSATION PREVENTING PLATE


The condensation preventing plate prevents moisture from entering the ceiling
construction via ducting holes. Dantherm No. 036422

PANEL FILTER PACK 3X3


To ensure optimal performance of the unit filters should be changed regulary. The
filter pack contains nine filters (three pos. F7 and six pos. G3).
Dantherm No. 032798

3.03
G E N E R A L D E S C R I PT I O N 4
General description
HRV 5
FUNCTION
HRV 5 is the perfect ventilation solution to create and maintain a healthy living
environment.

The HRV 5 unit is supplied as standard with a user-friendly wireless remote control
in a modern design.

APPLICATION
HRV 5 is particularly suitable for apartments and 1 or 2 bedroom homes of betwe-
en 80 and 200 m2 where an air change rate of 0.5/hour is required.

INSTALLATION
The HRV 5 compact dimensions ensure that it can be placed instead of a standard
60 cm wide wall unit closet.

The HRV 5 can be installed in a utility room or cupboard and controlled anywhere
in the home using the wireless remote.

CHARACTERISTICS
• Wireless remote control
• High efficiency of up to 80%
• Variable air volume with 3 speed settings
• Week programmer
• Summer mode

WIRELESS REMOTE CONTROL


The wireless remote control communicates via an antenna signal and has an oper-
ating range of approx. 100m (free field).

The remote control enables the user access to the following key functions:
• Week programmer – set different air volumes for different time periods
• 3 speed fan speed / air volume settings
• Summer mode
• Filter change timer with alarm
• Running data readout

4.01
4 G E N E R A L D E S C R I PT I O N

OPTIONAL HYGROSTAT
If an optional hygrostat (see accessories) is connected, the unit will increase to fan
speed 3 when the set relative humidity value is exceeded. The unit will return to the
original fan speed when the humidity level has been reduced.

2 3 1 4

ILLUSTRATION OF AIR FLOW IN HRV 5


1 Fresh air intake
2 Supply air
3 Return air
4 Exhaust air

ROTARY HEAT EXCHANGER


The HRV 5 is fitted with a rotary heat exchanger. In a rotary heat exchanger heat is
transferred from the extract air to the metallic surface of the rotor, which finally
transfers the heat to the supply air.

The rotary heat exchanger is a particularly good solution at temperatures below 0°C
as unlike traditional crossflow and counterflow heat exchangers, there is no risk of
ice formation. As a result no preheating is required which makes the rotary heat
exchanger an energy-friendly solution with very low running costs.

The rotary wheel is stopped in summer mode to provide fresh air cooling during the
night. This is automatically activated when the outdoor temperature exceeds a pre-
set value and therefore heat recovery is not required.

PART NUMBERS
Standard model
HRV 5 unit plus remote controller Dantherm nr. 026836

4.02
T EC H N I C A L D ATA 5
Te c h n i c a l d a t a

Heat exchanger type Rotary heat exchanger


Efficiency % Up to 80%
Max. air volume m3/h 340m3/h at 150 Pa
Power supply V/Hz 230 V/50Hz
Operating temperature range °C -20 to +50
Max. power consumption with and
without electric heating element* Watt 900/270
Sound level (1 meter from the cabinet)
- at 1000 r.p.m. dB(A) 43,6
- at 1500 r.p.m. dB(A) 45,7
- at 2000 r.p.m. dB(A) 49,8
Weight kg 55
Colour RAL 9016
Protection class IP 44
Duct connection mm Ø160
Filter type F/G G4 extract and F7 supply air
Material, cabinet Powder painted hot galvanized steel
Material, remote control ABS plastic

*incl. rotor motor

DIMENSIONS
612,1 592,6
821,4

481,9
281,9
251,9
131,2

101,9
356,2

17
476,2

160

56
Ø1
60

All dimensions are in mm.

5.01
5 T EC H N I C A L D ATA

PERFORMANCE CURVES
Air Volume Performance Curves of HRV 5
300

250
Available Pressure Pa

200

150

100

50
SFP = 1200 J/m3
0
0 50 100 150 200 250 300 350 400 450 500
Air Volume m3/h
E4
E4=exhaust 100% air volume S4=supply 100% air volume S4
E3
E3=exhaust 70% air volume S3=supply 70% air volume
S3
E2=exhaust 50% air volume S2=supply 50% air volume E2
E1=exhaust 25% air volume S1=supply 25% air volume S2
E1
S1
Please note:
HRV 5 has three different settings for air volume, where each setting can be set between 25 and 100%.
The performance curves for max. air volume (E4; S4) shown are not the factory setting. The factory setting corresponds to approx.
70% of the stated max. air volume (E3; S3).
The performance curves E2; S2 (= 50% air volume) and E1; S1 (= 25% air volume) correspond to the factory setting for these two
air volumes.

TEMPERATURE EFFICIENCY

Supply Air Heat Recovery Efficiency of HRV 5


100

90

80

70
Efficiency %

60

50

40

30

20

10

0
0 50 100 150 200 250 300 350 400
Exhaust Air Volume m3/h

Conditions: t fresh air = 4°C, t return air = 20°C and RH return air = 50%.

5.02
A CC E SS O R I E S 6
ELECTRIC HEATING ELEMENT, 630W
With an electrical heating element installed, the supply air temperature can be
increased by approx. 7-8°C (at 200 m3/h). The heater capacity is modulating from
63 to 630W to provide stable supply air temperatures.
When the heating element is active it will be indicated on the remote control.
Dantherm No. 041711

ADDITIONAL REMOTE CONTROL


The unit can be paired with additional remote controls to give flexibility.
Dantherm No. 041709

NHYGROSTAT
M
REHTN
A
D (INCL. 3 M CABLE)
The hygrostat can be mounted in bathrooms to provide boost dehumidification
after showering. With this function the unit will run on maximum speed when the
hygrostat detects high RH. Dantherm No. 041704

ALARM CABLE
Used for the optional connection of external light or audible alarms to alert the user
in the event of unit component failures. Alarm accessories are not available from
Dantherm. Cable length 3,5 m, Mini-Fit Jr. connector. Dantherm No. 041708

O
N
0
4
1
7M
REHTN
.FILTERS
A
D
To ensure optimal performance of the unit filters should be changed regularly. The
filter pack contains one F7 supply air filter and one G4 extract air filter.
Dantherm No. 031831

6.01
Since 1958 Dantherm Air Handling has Our core business areas are dehumidifi- Our Head Office is located in Denmark,
developed and produced climate control cation, heating, air conditioning, ventila- and we have companies in Denmark,
and air handling solutions that ensure tion and electronics cooling. Innovative, Norway, Sweden, the United Kingdom,
optimum conditions for people and durable and cost-efficient products the United States and China, with an
sensitive equipment alike. No climate is have secured us a position as a leading extensive European dealer network.
too extreme for us to handle – from the global manufacturer of stationary and
bitter cold at the North and South Poles mobile climate control units. And we are Dantherm Air Handling is part of the
to the searing heat of the Sahara. forever pursuing new techniques that Dantherm A/S group.
will improve our solutions and ultimately
your projects.

HEAD OFFICE COMPANIES

DENMARK NORWAY CHINA


Dantherm Air Handling Holding A/S Dantherm Air Handling A/S Dantherm Air Handling AS Dantherm Air Handling (Suzhou) Co., Ltd.
Marienlystvej 65 Marienlystvej 65 Løkkeåsveien 26 Bldg. # 9, No. 855 Zhu Jiang Rd.
DK-7800 Skive DK-7800 Skive N-3138 Skallestad Suzhou New District, Jiangsu
Denmark Denmark Norway 215219 Suzhou
Tel.: +45 9614 3700 Tel.: +45 9614 3700 Tel: +47 33 35 16 00 China
Fax: +45 9614 3800 Fax: +45 9614 3800 Fax: +47 33 38 51 91 Tel.: +86 512 6667 8500
E-mail: dantherm.dk@dantherm.com E-mail: dantherm.dk@dantherm.com E-mail: dantherm.no@dantherm.com Fax.: +86 512 6667 8501
www.dantherm-air-handling.com www.dantherm-air-handling.com www.dantherm-air-handling.com E-mail: dantherm.cn@dantherm.com
www.dantherm-air-handling.com

ENGLAND USA SWEDEN


Dantherm Air Handling Ltd. Dantherm Air Handling Inc. Kontrollelektronik Dantherm Air Handling AB
12 Windmill Business Park 4260 Orchard Park Blvd, Virkesgatan 5
Windmill Road Spartanburg SE-614 31 Söderköping
Clevedon South Carolina 29303-4400 Sweden
North Somerset BS21 6SR USA Tel.: +46 (0) 121-130 40
United Kingdom Tel.: +1 864 595 9800 Fax: +46 (0) 121-133 70
Tel.: +44 (0) 1275 876851 Fax: +1 864 595 9810 E-mail: info@kontrollelektronik.se
Fax: +44 (0) 1275 343086 E-mail: dantherm.usa@dantherm.com www.kontrollelektronik.se
E-mail: dantherm.co.uk@dantherm.com www.dantherm-air-handling.com
www.dantherm-air-handling.com