You are on page 1of 113

BAR SCHEDULE

ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

Footings
F1 14 2.60 24 5 312 312
8 1.40 4 5 28 28
F2 14 2.25 20 18 810 810
8 1.25 4 18 90 90
F3 12 1.90 18 23 786.6 786.6
8 1.10 4 23 101.2 101.2

F4 12 1.60 14 7 156.8 156.8


8 0.90 4 7 25.2 25.2

Foundation column
C1 20 4.75 10 2 95
8 1.30 17 2 44.2 44.2
C2 16 4.59 8 1 36.72 36.72
8 1.20 17 1 20.4 20.4
C3 20 4.75 12 1 57
8 1.10 17 1 18.7 18.7
C4 20 4.75 8 2 76
8 1.30 17 2 44.2 44.2
C5 20 4.75 12 18 1026
8 1.10 17 18 336.6 336.6

C5' 20 4.75 12 4 228


BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

8 1.10 17 4 74.8 74.8


C6 16 4.59 8 4 146.88 146.88
8 1.00 17 4 68 68
C7 20 4.75 8 11 418
8 1.10 17 11 205.7 205.7
C8 16 4.59 8 6 220.32 220.32
8 1.10 17 6 112.2 112.2
C9 20 4.75 8 2 76
8 1.10 17 2 37.4 37.4
C10 14 4.51 6 2 54.12 54.12
8 0.89 17 2 30.26 30.26
Grade Beams
GB1 14 38.97 2 1 77.94 77.94
12 38.37 2 1 76.74 76.74
8 1.20 190 1 228 228
GB2 14 44.17 2 1 88.34 88.34
12 43.57 2 1 87.14 87.14
8 1.20 215 1 258 258
GB3 14 48.85 2 1 97.7 97.7
12 48.25 239 1 11531.75 11531.8
8 1.20 239 1 286.8 286.8
GB4 14 47.27 2 1 94.54 94.54
12 46.77 2 1 93.54 93.54
8 1.20 232 1 278.4 278.4
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
GB5 14 4.25 2 1 8.5 8.5
12 3.75 2 1 7.5 7.5
8 1.20 18 1 21.6 21.6
GB6 14 4.05 2 1 8.1 8.1
12 3.55 2 1 7.1 7.1
8 1.20 17 7 142.8 142.8
GB7 14 6.20 2 1 12.4 12.4
12 5.70 2 1 11.4 11.4
8 1.20 27 1 32.4 32.4
GB8 14 6.90 2 1 13.8 13.8
12 6.40 2 1 12.8 12.8
8 1.20 31 1 37.2 37.2
GB9 14 14.55 2 1 29.1 29.1
12 14.05 2 1 28.1 28.1
GB10 14 16.00 2 1 32 32
12 15.50 2 1 31 31
8 1.20 75 1 90 90
GB11 14 18.85 2 1 37.7 37.7
12 17.75 2 1 35.5 35.5
8 1.20 87 1 104.4 104.4
GB12 14 16.64 2 1 33.28 33.28
12 16.14 2 1 32.28 32.28
8 1.20 80 1 96 96
GB13 14 2.35 2 1 4.7 4.7
12 1.85 2 1 3.7 3.7
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 1.20 8 1 9.6 9.6
Ground Floor slab mesh
B/n axis 1-2 & B-N 8 36.42 7 1 254.94 254.94
8 1.15 153 1 175.95 175.95
b/n axis 2-3 & B-O 8 35.57 20 1 711.4 711.4
8 4.70 175 1 822.5 822.5
B/n axis 3-4 & A-O 8 40.37 8 1 322.96 322.96
8 1.75 188 1 329 329
b/n axis 4-5 & A-O 8 40.37 24 1 968.88 968.88
8 5.70 188 1 1071.6 1071.6
b/n axis 5-6' & G-J 8 4.67 9 1 42.03 42.03
8 1.88 20 1 37.6 37.6
TOTAL LENGTH (m) 0 7558.92 0 12902 1714.22 403.92
UNIT WEIGHT (kg/m) 0.222 0.395 0.617 0.889 1.210 1.580
TOTAL WEIGHT (kg) 0 2986 0 11469.8 2074.21 638.19

SUPER STRUCTURE
Elevation Columns
Ground Floor
C1 20 4.20 10 2 84
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 1.30 18 2 46.8 46.8
C2 16 4.04 8 1 32.32 32.32
8 1.20 18 1 21.6 21.6
C3 20 4.20 12 1 50.4
8 1.10 18 1 19.8 19.8
C4 20 4.20 8 2 67.2
8 1.20 18 2 43.2 43.2

C5 20 4.20 12 18 907.2
8 1.10 18 18 356.4 356.4

C5' 20 4.20 12 4 201.6


8 1.10 18 4 79.2 79.2

C6 16 4.04 8 4 129.28 129.28


8 1.00 18 4 72 72

C7 20 4.20 8 11 369.6
8 1.10 18 11 217.8 217.8

C8 16 4.04 8 6 193.92 193.92


8 1.10 18 6 118.8 118.8

C9 20 4.20 8 2 67.2
8 1.10 18 2 39.6 39.6
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

C10 14 3.63 6 2 43.56 43.56


8 0.89 18 2 32.04 32.04
First Floor
C1 20 4.20 10 2 84
8 1.30 18 2 46.8 46.8
C2 14 3.96 8 1 31.68 31.68
8 1.20 22 1 26.4 26.4
C3 20 4.20 8 1 33.6
8 1.10 18 1 19.8 19.8
C4 20 4.20 8 2 67.2
8 1.30 18 2 46.8 46.8

C5 20 4.20 8 18 604.8
8 1.10 18 18 356.4 356.4

C5' 20 4.20 8 4 134.4


8 1.10 18 4 79.2 79.2

C6 16 4.04 8 4 129.28 129.28


8 1.10 18 4 79.2 79.2

C7 16 4.04 8 11 355.52 355.52


8 1.10 18 11 217.8 217.8
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

C8 14 3.96 8 6 190.08 190.08


8 1.10 22 6 145.2 145.2

C9 20 4.20 8 2 67.2
8 1.10 18 2 39.6 39.6
Second Floor
C1 20 4.20 10 2 84
8 1.30 18 2 46.8 46.8
C2 14 3.96 8 1 31.68 31.68
8 1.20 22 1 26.4 26.4
C3 16 4.04 8 1 32.32 32.32
8 1.10 18 1 19.8 19.8
C4 16 4.04 8 2 64.64 64.64
8 1.30 18 2 46.8 46.8

C5 16 4.04 8 18 581.76 581.76


8 1.10 18 18 356.4 356.4

C5' 16 4.04 8 4 129.28 129.28


8 1.10 18 4 79.2 79.2

C6 14 3.96 8 4 126.72 126.72


8 1.00 22 4 88 88
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

C7 14 3.96 8 11 348.48 348.48


8 1.10 18 11 217.8 217.8

C8 14 3.96 8 6 190.08 190.08


8 1.10 22 6 145.2 145.2

C9 16 4.04 8 2 64.64 64.64


8 1.10 18 2 39.6 39.6
Third Floor
C1 20 4.20 8 2 67.2
8 1.30 18 2 46.8 46.8
C2 14 3.96 6 1 23.76 23.76
8 1.20 22 1 26.4 26.4
C3 14 3.96 8 1 31.68 31.68
8 1.10 22 1 24.2 24.2
C4 16 4.04 8 2 64.64 64.64
8 1.30 18 2 46.8 46.8

C5 14 3.96 8 18 570.24 570.24


8 1.10 22 18 435.6 435.6

C5' 14 3.96 8 4 126.72 126.72


8 1.10 22 4 96.8 96.8
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

C6 14 3.96 8 4 126.72 126.72


8 1.00 22 4 88 88

C7 14 3.96 8 11 348.48 348.48


8 1.10 18 11 217.8 217.8

C8 14 3.96 8 6 190.08 190.08


8 1.10 22 6 145.2 145.2

C9 16 3.63 4 2 29.04 29.04


8 0.89 18 2 32.04 32.04
Fourth Floor
C1 16 4.04 8 2 64.64 64.64
8 1.30 18 2 46.8 46.8
C2 14 3.96 6 1 23.76 23.76
8 1.10 22 1 24.2 24.2
C3 14 3.96 8 1 31.68 31.68
8 1.10 22 1 24.2 24.2
C4 16 3.63 8 2 58.08 58.08
8 1.30 18 2 46.8 46.8

C5 14 3.63 8 18 522.72 522.72


8 1.10 22 18 435.6 435.6
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE

C5' 14 6.00 8 4 192 192


8 1.10 27 4 118.8 118.8

C6 14 3.58 8 4 114.56 114.56


8 1.00 22 4 88 88

C7 14 3.63 8 11 319.44 319.44


8 1.10 22 11 266.2 266.2

C8 14 3.63 8 6 174.24 174.24


8 1.10 22 6 145.2 145.2

C11 14 6.00 4 2 48 48
8 0.90 22 2 39.6 39.6
Roof Top
C1 14 3.38 8 2 54.08 54.08
8 1.30 20 2 52 52
C2 14 3.48 6 1 20.88 20.88
8 1.10 22 1 24.2 24.2
C3 14 3.38 8 1 27.04 27.04
8 1.10 22 1 24.2 24.2

Floor Beams
FB1 @ level 3.4m 12 5.87 2 1 11.74 11.74
12 5.37 2 1 10.74 10.74
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 1.10 28 1 30.8 30.8

FB2 @ level 3.4,6.8,10.2 &13.6m 14 19.30 2 4 154.4 154.4


14 6.11 1 4 24.44 24.44
16 2.40 1 4 9.6 9.6
8 1.10 99 4 435.6 435.6

FB3 @ level 3.4,6.8,10.2 &13.6m 14 19.65 2 4 157.2 157.2


14 4.71 1 4 18.84 18.84
14 19.15 2 4 153.2 153.2

8 1.10 105 4 462 462


FB4 @ level 3.4m 14 5.87 2 1 11.74 11.74
14 5.37 2 1 10.74 10.74
8 1.10 29 1 31.9 31.9
FB5 @ level 3.4,6.8,10.2 &13.6m 16 48.82 2 4 390.56 390.56
12 48.32 2 4 386.56 386.56
8 1.10 256 4 1126.4 1126.4
FB6 @ level 3.4,6.8,10.2 &13.6m 16 47.27 2 4 378.16 378.16
14 5.45 1 4 21.8 21.8
14 36.47 2 4 291.76 291.76
12 10.30 2 4 82.4 82.4
8 1.10 256 4 1126.4 1126.4
FB7 @ level 3.4,6.8,10.2 &13.6m 16 4.35 4 4 69.6 69.6
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
16 3.65 4 4 58.4 58.4
8 1.10 19 4 83.6 83.6
FB8 @ level 3.4,6.8,10.2 &13.6m 16 4.20 4 4 67.2 67.2
16 3.50 4 4 56 56
8 1.10 256 4 1126.4 1126.4
FB9 @ level 3.4,6.8,10.2 &13.6m 16 19.02 2 4 152.16 152.16
12 18.55 2 4 148.4 148.4
8 1.10 102 4 448.8 448.8
FB10 @ level 3.4,6.8,10.2 &13.6m 16 22.17 2 4 177.36 177.36
16 2.68 2 4 21.44 21.44
16 21.67 2 4 173.36 173.36
8 1.10 116 4 510.4 510.4
FB11 @ level 3.4,6.8,10.2 &13.6m 16 6.19 2 4 49.52 49.52
16 5.69 2 4 45.52 45.52
8 1.10 30 4 132 132
FB12 @ level 3.4,6.8,10.2 &13.6m 16 6.90 2 4 55.2 55.2
16 3.43 2 4 27.44 27.44
16 2.48 2 4 19.84 19.84
14 5.04 1 4 20.16 20.16
14 6.40 2 4 51.2 51.2
8 1.10 34 4 149.6 149.6
FB13 @ level 3.4,6.8 & 10.2m 16 14.55 2 3 87.3 87.3
16 14.05 2 3 84.3 84.3
16 6.91 2 3 41.46 41.46
20 5.52 2 3 33.12
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 1.10 85 3 280.5 280.5
FB14 @ level 3.4,6.8 , 10.2 & 13.6m 20 15.66 2 4 125.28
14 3.29 2 4 26.32 26.32
20 5.52 2 4 44.16
20 2.48 2 1 4.96
16 4.62 1 4 18.48 18.48
16 14.05 2 4 112.4 112.4
8 1.10 93 4 409.2 409.2
FB15 @ level 3.4,6.8 , 10.2 &13.6m 20 14.55 2 4 116.4
14 2.29 1 4 9.16 9.16
20 5.52 2 4 44.16
14 4.62 2 4 36.96 36.96
16 14.05 2 4 112.4 112.4
8 1.10 115 4 506 506
FB16 @ level 3.4,6.8 , 10.2 &13.6m 20 16.53 2 4 132.24
20 5.52 1 4 22.08
16 4.20 1 4 16.8 16.8
16 15.43 2 4 123.44 123.44
8 1.10 92 4 404.8 404.8
FB17 @ level 3.4,6.8 , 10.2 &13.6m 16 18.85 2 4 150.8 150.8
20 3.09 2 4 24.72
16 3.50 1 4 14 14
16 5.52 2 4 44.16 44.16
14 4.20 1 4 16.8 16.8
8 1.10 174 4 765.6 765.6
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
FB18 @ level 3.4m 16 16.64 2 1 33.28 33.28
16 7.70 1 1 7.7 7.7
20 8.13 2 1 16.26
16 16.14 2 1 32.28 32.28
8 1.10 124 1 136.4 136.4
FB19 @ level 3.4,6.8 , 10.2 &13.6m 16 14.55 2 4 116.4 116.4
16 8.47 1 4 33.88 33.88
20 5.52 2 4 44.16
16 14.05 2 4 112.4 112.4
8 1.10 98 4 431.2 431.2
FB20 @ level 6.8 , 10.2 &13.6m 16 17.40 2 3 104.4 104.4
20 2.14 2 3 12.84
16 3.85 1 3 11.55 11.55
14 4.20 1 3 12.6 12.6
16 5.52 2 3 33.12 33.12
16 16.30 2 3 97.8 97.8
8 1.10 96 3 316.8 316.8
FB21 @ level 6.8 , 10.2 &13.6m 16 15.19 2 3 91.14 91.14
16 8.05 1 3 24.15 24.15
20 8.13 2 3 48.78
16 14.69 2 3 88.14 88.14
8 1.10 106 3 349.8 349.8
FB21 @ level 6.8 , 10.2 &13.6m 16 15.19 2 3 91.14 91.14
16 8.05 1 3 24.15 24.15
20 8.13 2 3 48.78
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
16 14.69 2 3 88.14 88.14
8 1.10 106 3 349.8 349.8
FB22 @ level 13.6m 16 16.13 2 1 32.26 32.26
16 6.49 1 1 6.49 6.49
20 9.37 2 1 18.74
16 15.43 2 1 30.86 30.86
8 1.10 110 1 121 121
FB23 @ level 13.6m 20 17.61 2 1 35.22
14 3.29 1 1 3.29 3.29
20 9.37 2 1 18.74
16 4.20 1 1 4.2 4.2
16 15.43 2 1 30.86 30.86
8 1.10 124 1 136.4 136.4
FB24 @ level 17.00m 14 12.00 2 1 24 24
14 11.50 2 1 23 23
8 1.10 65 1 71.5 71.5
Roof Beams
RB1 @ Level 17.00m 14 19.30 2 1 38.6 38.6
14 2.40 1 1 2.4 2.4
12 18.80 2 1 37.6 37.6
8 1.10 103 1 113.3 113.3
RB2 @ Level 17.00m 14 19.65 2 1 39.3 39.3
14 5.34 1 1 5.34 5.34
12 19.15 2 1 38.3 38.3
8 1.10 105 1 115.5 115.5
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
RB3 @ Level 17.00m 12 5.87 2 1 11.74 11.74
12 5.37 2 1 10.74 10.74
8 1.10 29 1 31.9 31.9
RB4 @ Level 17.00m 14 48.82 2 1 97.64 97.64
12 46.96 2 1 93.92 93.92
8 1.10 264 1 290.4 290.4
RB5 @ Level 17.00m 14 47.27 2 1 94.54 94.54
14 5.45 1 1 5.45 5.45
12 46.77 1 1 46.77 46.77
8 1.10 256 1 281.6 281.6
RB6 @ Level 17.00m 16 7.35 2 1 14.7 14.7
16 6.85 2 1 13.7 13.7
8 1.10 38 7 292.6 292.6
RB7 @ Level 17.00m 12 12.00 2 1 24 24
12 11.50 2 1 23 23
8 1.10 65 1 71.5 71.5
RB8 @ Level 17.00m 14 25.27 2 1 50.54 50.54
12 24.77 2 1 49.54 49.54
8 1.10 134 1 147.4 147.4
RB9 @ Level 17.00m 14 6.19 2 1 12.38 12.38
14 5.69 2 1 11.38 11.38
8 1.10 30 1 33 33
RB10 @ Level 17.00m 14 8.28 2 1 16.56 16.56
12 7.78 75 1 583.5 583.5
8 1.10 43 1 47.3 47.3
RB11 @ Level 17.00m 14 8.00 2 1 16 16
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
12 7.50 2 1 15 15
8 1.10 41 1 45.1 45.1
RB12 @ Level 17.00m 16 8.76 2 1 17.52 17.52
14 7.50 2 1 15 15
8 1.10 41 1 45.1 45.1
RB13@ Level 17.00m 14 15.93 2 2 63.72 63.72
14 5.52 1 2 11.04 11.04
16 3.85 1 2 7.7 7.7
16 15.43 2 2 61.72 61.72
8 1.10 93 2 204.6 204.6
RB14@ Level 17.00m 16 15.66 2 1 31.32 31.32
14 10.14 1 1 10.14 10.14
14 14.05 2 1 28.1 28.1
8 1.10 75 1 82.5 82.5
RB15 @ Level 17.00m 16 16.80 2 1 33.6 33.6
20 5.52 2 1 11.04
16 8.43 1 1 8.43 8.43
16 16.30 2 1 32.6 32.6
8 1.10 51 1 56.1 56.1
RB16 @ Level 17.00m 16 15.19 2 1 30.38 30.38
16 5.52 1 1 5.52 5.52
14 4.20 1 1 4.2 4.2
16 14.69 2 1 29.38 29.38
8 1.10 80 1 88 88
RB17 @ Level 17.00m 16 14.55 2 4 116.4 116.4
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
16 5.52 1 4 22.08 22.08
14 4.62 1 4 18.48 18.48
14 14.05 2 4 112.4 112.4
8 1.10 75 4 330 330
RB18 @ Level 17.00m 12 6.20 2 3 37.2 37.2
14 5.70 2 3 34.2 34.2
8 1.10 19 3 62.7 62.7
RB19 @ Level 17.00m 16 8.28 2 1 16.56 16.56
16 7.78 2 1 15.56 15.56
8 1.10 43 1 47.3 47.3
RB20 @ Level 19.00m 14 8.28 2 1 16.56 16.56
14 2.43 2 1 4.86 4.86
16 3.85 1 1 3.85 3.85
16 7.74 2 1 15.48 15.48
8 1.10 43 1 47.3 47.3
RB21 (Inclined beam at axis 4 (A-D) & 6(A-D 12 12.68 2 2 50.72 50.72
12 11.50 2 2 46 46
8 1.10 65 2 143 143
Solid slab
First Floor slab
Canteliver to FB2 and FB3 at axis 2 8 6.15 8 1 49.2 49.2
8 4.55 8 1 36.4 36.4
8 1.45 5 1 7.25 7.25
8 2.15 5 1 10.75 10.75
8 5.15 9 1 46.35 46.35
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 2.15 5 1 10.75 10.75
B/n axis 2-3 & B-O
Main Bars 10 5.17 11 1 56.87 56.87
10 6.69 8 1 53.52 53.52
10 6.02 25 1 150.5 150.5
8 11.06 16 1 176.96 176.96
8 8.58 20 1 171.6 171.6
8 9.41 25 1 235.25 235.25
8 10.80 25 1 270 270
8 8.08 15 1 121.2 121.2
8 8.58 20 1 171.6 171.6
8 4.20 25 1 105 105
10 8.28 25 1 207 207
8 9.89 16 1 158.24 158.24
Negative Bars 10 2.89 25 1 72.25 72.25
10 3.03 40 1 121.2 121.2
10 4.89 40 1 195.6 195.6
10 2.62 25 1 65.5 65.5
10 2.35 25 1 58.75 58.75
10 3.35 32 1 107.2 107.2
10 2.76 52 1 143.52 143.52
10 2.30 27 1 62.1 62.1
10 3.00 14 1 42 42
10 4.35 32 1 139.2 139.2
10 2.90 11 1 31.9 31.9
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
10 2.30 24 1 55.2 55.2
10 2.56 25 1 64 64
10 2.89 50 1 144.5 144.5
10 3.03 65 1 196.95 196.95
10 2.53 20 1 50.6 50.6
10 2.64 25 1 66 66
B/n axis 3-4 & A-O
Main Bars 10 7.83 10 1 78.3 78.3
8 10.10 10 1 101 101
8 8.52 10 1 85.2 85.2
8 11.20 10 1 112 112
8 8.28 10 1 82.8 82.8
Negative bars 10 2.00 110 1 220 220
10 5.06 16 1 80.96 80.96
10 4.35 32 1 139.2 139.2
10 4.42 17 1 75.14 75.14
10 3.97 25 1 99.25 99.25
10 4.22 15 1 63.3 63.3
10 4.89 60 1 293.4 293.4
B/n axis 4-5 & A-O
Main Bars 10 10.04 16 1 160.64 160.64
10 8.44 30 1 253.2 253.2
8 7.40 60 1 444 444
8 10.60 46 1 487.6 487.6
8 7.34 47 1 344.98 344.98
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 3.50 13 1 45.5 45.5
8 10.54 38 1 400.52 400.52
8 8.22 46 1 378.12 378.12
8 7.34 23 1 168.82 168.82
8 7.40 90 1 666 666
8 8.20 46 1 377.2 377.2
8 5.35 30 1 160.5 160.5
Negative bars 10 2.04 16 1 32.64 32.64
10 2.64 40 1 105.6 105.6
10 2.89 30 1 86.7 86.7
10 2.62 30 1 78.6 78.6
10 2.35 40 1 94 94
12 6.24 17 1 106.08 106.08
10 2.90 40 1 116 116
10 2.56 34 1 87.04 87.04
10 2.89 68 1 196.52 196.52
10 4.20 25 1 105 105
Second and Third Typical Floor slab
Canteliver to FB2 and FB3 at axis 2 8 6.15 8 2 98.4 98.4
8 4.55 8 2 72.8 72.8
8 1.45 4 2 11.6 11.6
8 2.15 4 2 17.2 17.2
8 5.15 8 2 82.4 82.4
8 2.15 4 2 17.2 17.2
B/n axis 2-3 & B-O
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
Main Bars 8 8.58 72 2 1235.52 1235.52
10 9.41 25 2 470.5 470.5
8 10.86 25 2 543 543
8 11.06 17 2 376.04 376.04
8 8.08 35 2 565.6 565.6
8 8.58 40 2 686.4 686.4
8 8.16 25 2 408 408
8 4.20 25 2 210 210
10 8.44 25 2 422 422
8 9.99 16 2 319.68 319.68
Negative bars 10 3.03 66 2 399.96 399.96
10 2.89 25 2 144.5 144.5
10 2.62 25 2 131 131
10 2.35 25 2 117.5 117.5
10 2.76 52 2 287.04 287.04
10 2.39 25 2 119.5 119.5
10 2.30 51 2 234.6 234.6
10 2.56 25 2 128 128
10 2.89 50 2 289 289
10 3.03 50 2 303 303
10 2.53 33 2 166.98 166.98
10 2.64 25 2 132 132
B/n axis 3-4 & A-O
Main Bars 10 7.83 10 2 156.6 156.6
10 10.04 16 2 321.28 321.28
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 10.60 10 2 212 212
8 8.52 10 2 170.4 170.4
8 11.20 10 2 224 224
8 8.44 10 2 168.8 168.8
Negative Bars 10 2.00 110 2 440 440
10 4.89 100 2 978 978
10 4.35 32 2 278.4 278.4
10 4.42 17 2 150.28 150.28
10 3.97 25 2 198.5 198.5
10 4.22 15 2 126.6 126.6
10 5.06 16 2 161.92 161.92
B/n axis 4-5 & A-O
Main Bars 10 8.44 46 2 776.48 776.48
8 7.40 150 2 2220 2220
8 10.60 46 2 975.2 975.2
8 7.34 48 2 704.64 704.64
8 3.50 13 2 91 91
8 10.19 38 2 774.44 774.44
8 8.22 46 2 756.24 756.24
8 7.34 22 2 322.96 322.96
8 8.20 46 2 754.4 754.4
10 5.35 30 2 321 321
Negative Bars 10 2.64 40 2 211.2 211.2
10 2.89 65 2 375.7 375.7
10 2.62 30 2 157.2 157.2
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
10 2.35 40 2 188 188
12 6.24 17 2 212.16 212.16
10 2.90 30 2 174 174
10 2.56 34 2 174.08 174.08
12 4.78 7 2 66.92 66.92
Fourth Floor slab
Canteliver to FB2 and FB3 at axis 2 8 6.15 8 1 49.2 49.2
8 4.55 8 1 36.4 36.4
8 1.45 5 1 7.25 7.25
8 2.15 5 1 10.75 10.75
8 5.15 9 1 46.35 46.35
8 2.15 5 1 10.75 10.75
B/n axis 2-3 & B-O
Main Bars 8 8.58 72 1 617.76 617.76
10 9.41 25 1 235.25 235.25
8 10.86 25 1 271.5 271.5
8 11.06 17 1 188.02 188.02
8 8.08 35 1 282.8 282.8
8 8.58 40 1 343.2 343.2
8 8.16 25 1 204 204
8 4.20 25 1 105 105
10 8.44 25 1 211 211
8 9.99 16 1 159.84 159.84
Negative bars 10 3.03 66 1 199.98 199.98
10 2.89 25 1 72.25 72.25
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
10 2.62 25 1 65.5 65.5
10 2.35 25 1 58.75 58.75
10 2.76 52 1 143.52 143.52
10 2.39 25 1 59.75 59.75
10 2.30 51 1 117.3 117.3
10 2.56 25 1 64 64
10 2.89 50 1 144.5 144.5
10 3.03 50 1 151.5 151.5
10 2.53 33 1 83.49 83.49
10 2.64 25 1 66 66
B/n axis 3-4 & A-O
Main Bars 10 7.83 10 1 78.3 78.3
10 10.04 16 1 160.64 160.64
8 10.60 10 1 106 106
8 8.52 10 1 85.2 85.2
8 11.20 10 1 112 112
8 8.44 10 1 84.4 84.4
Negative Bars 10 2.00 110 1 220 220
10 4.89 100 1 489 489
10 4.35 32 1 139.2 139.2
10 4.42 17 1 75.14 75.14
10 3.97 25 1 99.25 99.25
10 4.22 15 1 63.3 63.3
10 5.06 16 1 80.96 80.96
B/n axis 4-5 & A-O
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
Main Bars 10 8.44 46 1 388.24 388.24
10 7.60 150 1 1140 1140
8 10.60 46 1 487.6 487.6
8 7.34 48 1 352.32 352.32
8 3.50 13 1 45.5 45.5
8 10.19 38 1 387.22 387.22
8 8.22 46 1 378.12 378.12
8 7.34 22 1 161.48 161.48
8 8.20 46 1 377.2 377.2
10 5.35 30 1 160.5 160.5
Negative Bars 10 2.64 40 1 105.6 105.6
10 2.89 65 1 187.85 187.85
10 2.62 30 1 78.6 78.6
10 2.35 40 1 94 94
12 6.24 17 1 106.08 106.08
10 2.90 30 1 87 87
10 2.56 34 1 87.04 87.04
12 4.78 7 1 33.46 33.46
B/n axis 5-6 & A-D
Negative Bars 10 2.81 59 1 165.79 165.79
Roof slab
Canteliver to RB1 and RB2 at axis 2 8 6.15 8 1 49.2 49.2
8 4.55 8 1 36.4 36.4
8 1.45 5 1 7.25 7.25
8 2.15 5 1 10.75 10.75
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
8 5.15 9 1 46.35 46.35
8 2.15 5 1 10.75 10.75
B/n axis 2-3 & B-O
Main Bars 8 8.55 61 1 521.55 521.55
8 9.41 25 1 235.25 235.25
8 8.58 72 1 617.76 617.76
8 9.90 25 1 247.5 247.5
8 11.06 16 1 176.96 176.96
8 5.22 14 1 73.08 73.08
10 10.09 25 1 252.25 252.25
8 8.08 35 1 282.8 282.8
8 11.20 26 1 291.2 291.2
8 8.44 26 1 219.44 219.44
8 9.99 26 1 259.74 259.74
Negative bars 10 3.03 102 1 309.06 309.06
10 2.89 27 1 78.03 78.03
10 2.62 25 1 65.5 65.5
10 2.35 25 1 58.75 58.75
10 2.39 25 1 59.75 59.75
10 3.00 12 1 36 36
10 2.76 42 1 115.92 115.92
10 2.30 32 1 73.6 73.6
10 2.90 12 1 34.8 34.8
10 2.55 25 1 63.75 63.75
10 2.64 25 1 66 66
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
10 2.53 26 1 65.78 65.78
B/n axis 3-4 & A-O
Main Bars 8 3.56 16 1 56.96 56.96
8 7.83 10 1 78.3 78.3
8 10.60 10 1 106 106
8 8.52 10 1 85.2 85.2
8 11.20 10 1 112 112
8 8.44 10 1 84.4 84.4
Negative Bars 10 2.00 110 1 220 220
10 4.89 60 1 293.4 293.4
10 3.63 40 1 145.2 145.2
10 4.35 60 1 261 261
10 4.42 17 1 75.14 75.14
10 5.57 25 1 139.25 139.25
10 4.22 15 1 63.3 63.3
10 2.29 16 1 36.64 36.64
B/n axis 4-5 & D-O
Main Bars 8 9.88 30 1 296.4 296.4
8 7.34 94 1 689.96 689.96
8 8.22 40 1 328.8 328.8
8 8.20 30 1 246 246
8 8.44 30 1 253.2 253.2
8 7.40 79 1 584.6 584.6
8 8.47 25 1 211.75 211.75
Negative bars 10 2.35 30 1 70.5 70.5
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
12 6.24 17 1 106.08 106.08
10 4.25 25 1 106.25 106.25
10 2.90 30 1 87 87
10 2.56 30 1 76.8 76.8
10 2.89 60 1 173.4 173.4
10 2.64 30 1 79.2 79.2
Tanker slab
Main Bars 12 5.42 49 1 265.58 265.58
10 8.57 22 1 188.54 188.54
Negative bars 10 3.72 22 1 81.84 81.84
Staircases
Staircase 1
Thread and riser 8 0.89 140 4 498.4 498.4
14 1.12 11 4 49.28 49.28
14 1.68 11 4 73.92 73.92
14 4.80 11 4 211.2 211.2
14 1.91 11 4 84.04 84.04
14 2.71 11 4 119.24 119.24
14 2.60 11 4 114.4 114.4
14 1.80 11 4 79.2 79.2
14 5.73 11 4 252.12 252.12
14 1.20 11 4 52.8 52.8
14 1.55 11 4 68.2 68.2
14 2.04 11 4 89.76 89.76
14 1.80 11 4 79.2 79.2
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
14 4.27 11 4 187.88 187.88
14 1.91 11 4 84.04 84.04
14 2.71 11 4 119.24 119.24
8 1.46 36 4 210.24 210.24
Landing 8 3.06 16 4 195.84 195.84
LB1 @ level +1.7,5.1,8.5,11.9 & 15.3m 14 4.10 2 5 41 41
14 3.60 2 5 36 36
8 1.10 17 5 93.5 93.5
LB2 (2pcs) @ level +1.7,5.1,8.5,11.9 & 15.3 16 2.33 3 10 69.9 69.9
12 1.83 2 10 36.6 36.6
8 1.10 9 10 99 99
Staircase 2
Thread and riser 8 0.89 140 3 373.8 373.8
14 1.07 10 1 10.7 10.7
14 3.46 10 1 34.6 34.6
14 5.85 10 1 58.5 58.5
14 1.79 10 1 17.9 17.9
14 2.59 10 1 25.9 25.9
14 2.48 10 3 74.4 74.4
14 1.80 10 3 54 54
14 5.61 10 3 168.3 168.3
14 2.05 10 3 61.5 61.5
14 2.85 10 3 85.5 85.5
14 2.74 10 3 82.2 82.2
14 1.80 10 3 54 54
BAR SCHEDULE
ITE
M DESCRIPTION DIA LENGTH NO OF TOTAL NO
NO MEMBERS 6 8 10 12 14 16
METER BARS BARS
SUB STRUCTURE
14 5.86 10 3 175.8 175.8
14 1.91 10 3 57.3 57.3
14 2.71 10 3 81.3 81.3
8 1.36 36 3 146.88 146.88
Landing 8 2.86 16 3 137.28 137.28
LB3 @ level +1.7,5.1,8.5 &11.9m 14 4.00 2 4 32 32
14 3.50 2 4 28 28
8 1.10 13 3 42.9 42.9
TOTAL LENGTH (m) 0 48554.9 21935 2640.83 8528.22 6127
UNIT WEIGHT (kg/m) 0.222 0.395 0.617 0.889 1.210 1.580
TOTAL WEIGHT (kg) 0 19179 13534 2347.70 10319.1 9680.7
20 24

95

57

76

1026

228
20 24

418

76
20 24
20 24

1976 0 0 0 0 0
2.469 3.556 4.173 4.840 5.556 6.321
4878.7 0 0 0 0 0

84
20 24

50.4

67.2

907.2

201.6

369.6

67.2
20 24

84

33.6

67.2

604.8

134.4
20 24

67.2

84
20 24

67.2
20 24
20 24
20 24
20 24

33.12
20 24

125.28

44.16
4.96

116.4

44.16

132.24
22.08

24.72
20 24

16.26

44.16

12.84

48.78

48.78
20 24

18.74

35.22

18.74
20 24
20 24

11.04
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24
20 24

3691.3 0 0 0 0 0
2.469 3.556 4.173 4.840 5.556 6.321
9113.8 0 0 0 0 0
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
1 22.23 EGA Roof
12 266.76
266.76 m2 34.3
1 12 12 3.2 Gutter (97cm development length)
12 ml

3.3 Gutter (87cm development length)


2 12 24 24 ml

3.4. Down Pipe


6 5 30 30 ml
3.5. Ridge Cover
2 8.35 16.7 16.7 ml
1 21.10 Armstrong ceiling
11.8 248.98
248.98 m2

RHS truss
31 7.41 229.71 Truss upper chord (60x60x3mm)
28.26 kg/m
6491.6 kg
31 8 248 truss lower chord (70x50x3mm)
27.475 kg/m
6813.8 kg
31 11.114 344.534 Truss vertical and diagonal members (40x40x3mm)
12.56 kg/m
4327.35 kg
28 11.8 330.4 purlin (40x40x3mm)
12.56 kg/m
4149.82 kg
Aluminium Plate
2 65.84 For External Walls
3.30
434.54
10 3.38 ddt (W1)
2.10
-70.98
2 5.4 ddt (W2)
2.10
-22.68
2 6.05 ddt (W3)
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
2.10
-25.41
1 1.2 ddt (WD1)
3.30
-3.96
1 2.1 ddt (WD1)
1.29
-2.71
1 3.3 ddt (WD2)
1.80
-5.94
1 2.1 ddt (WD2)
4.20
-8.82
294.04 m2 Total
2 24.78 For Internal walls
3.30
163.55
163.55 m2 Total
2 65.84 For decoration wall at the top
0.60
79.01
373.05 m2Total External sum
536.60 m2 Total Internal and External

Steel structural work


RHS Stair
1 21.6 21.6 m Step (20x40x3mm)
6.28 kg/m
135.648 kg
RHS (20x40x2mm)
263 3.42 899.46 vertical member for external walls
14 65.84 921.76 horizontal member for external walls
100 3.42 342 vertical member for internal walls
14 25 350 horizontal member for internal walls
2 65.84 131.68 for decoration aluminium wall.
1 134 134
6.28 Kg/m
17451.5 Kg
10 1.1 11 RHS landing (30x40x3mm)
9.42 Kg/m
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
103.62 Kg
4 1.1 4.4 RHS landing (40x50x3mm)
15.7 Kg/m
69.08 Kg
1 8 8 RHS landing (60x60x3mm)
28.26 Kg/m
226.08 Kg

1 43.2 43.2 Step (40x40x3mm)


1 38 38 Vertical pos(40x40x3mm)
12.56 Kg/m
1019.87 Kg
1 27 27 Handrail (50x50x3mm)
19.625 Kg/m
529.875 Kg
31 m RHS column post (80x80x3mm) for stair
18 3.42 61.56 for beams
50.24 Kg/m
4650.21 Kg
1 18 18 Diagonal stair member (70x50x3mm)
1 65.84 65.84 Beam
27.475 Kg/m
2303.5 Kg
1 pcs 1100x1100x3mm galvanized steel chekered Plate
18 pcs 1200x300x3mm galvanized steel chekered plate
1 pcs 3000x1100x3mm galvanized steel chekered plate
4 28 112 pcs 200x200x3mm metal plate anchored to J and normal bolt
4 28 112 pcs M-14 diameter 49mm grade 8.8 L=165mm J- bolt
4 28 112 pcs M-12 diameter 49mm grade 8.8 bolt
1 62 62 pcs 70x100x3mm connecting plate
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION

chs 51.85
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
TAKEOFF SHEET
TIM DIMEN QTY TOTAL
SING SION QTY DESCRIPTION
17.15

embers (40x40x3mm)
m) for stair

teel chekered Plate


eel chekered plate
teel chekered plate
hored to J and normal bolt
8 L=165mm J- bolt
SUMMARY OF BILL OF QUANTITIES

CENTRAL COMMAND

A-SUB STRUCTURE

1 EXCAVATION & EARTH WORK ETH.BIRR #REF!

2 CONCRETE WORK ,, ,, #REF!

3 MASONRY WORK ,, ,, #REF!

TOTAL A ,, ,, #REF!

B. SUPER STRUCTURE

1 CONCRETE WORK ........................................................................ ETH.BIRR #REF!


2 BLOCK WORK ............................................................................. ,, ,, #REF!

3 ROOFING.............................................................................. ,, ,, 181,559.52

4 CARPENTERY & JONERY ........................................................ ,, ,, #REF!

5 METAL WORK ................................................................... ,, ,, #REF!

6 FINISHING WORK ............................................................... ,, ,, #REF!

7 PANITING WORK ......................................................................... ,, ,, #REF!

8 GLAZING .............................................................................. ,, ,, #REF!

9 ELECTRICAL INSTALLATION ....................................................... ,, ,, 406,612.11

10 SANITARY INSTALLATION .......................................................... ,, ,, 631,621.22

TOTAL B ,, ,, #REF!

TOTAL A + B ,, ,, #REF!

15% VAT ,, ,, #REF!

CONTIGENCY (8%) ,, ,, #REF!

GRAND TOTAL ,, ,, #REF!


PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

A-SUB STRUCTURE
1. EXCAVATION & EARTH WORK
1.1 Clear and remove top soil to an average depth of 200mm. M2 #REF! 13.72 #REF!

1.2 Bulk excavation in ordinary soil from the natural ground


level to a depth not exceeding 50 cm.

A) In ordinary soil
M3 #REF! 78.34 #REF!
B) In soft rock M3 1.00 95.37 95.37
C) In hard rock M3
1.00 591.21 591.21
D) In boulder M3 1.00 465.40 465.40

1.3 Trench excavation for masonary wall from reduced level


to a depth of not exceeding 1m .

A) In ordinary soil M3 #REF! 230.28 #REF!


B) In soft rock M3
1.00 240.76 240.76
C) In hard rock M3
1.00 602.93 602.93
D) In boulder M3 1.00 510.80 510.80
1.4 Excavation for isolated footing to a depth not exceeding
150 cm from reduce level .
A) In ordinary soil M3 #REF! 230.28 #REF!
B) In soft rock M3 1.00 240.76 240.76
C) In hard rock M3 1.00 602.93 602.93
D) In boulder M3 1.00 510.80 510.80
1.5 Ditto item 1.4 but exceeding 150cm but not exceeding
300cm
A) In ordinary soil M3 #REF! 316.21 #REF!
B) In soft rock M3 1.00 353.11 353.11
C) In hard rock M3 1.00 680.72 680.72
D) In boulder M3 1.00 523.58 523.58
1.6 Fill around footings and foundation column to maintain
the desired level with selected borrowed non expansive
material and compact in layers not exceeding 20cm.
M3 #REF! 469.53 #REF!

1.7 Fill around stone masonry to maintain the desired level


with selected borrowed non expansive material and
compact in layers not exceeding 200mm.
M3 #REF! 469.53 #REF!

1.8 Backfill under hard core with non-expansive selected


material from out side and compact in layers not
exceeding 20cm.
M3 #REF! 469.53 #REF!
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

1.9 Cart away surplus excavated material to a distance not


exceeding 10kms away from site.
M3 #REF! 68.02 #REF!
1.10 Diito item 1.9 but cart away boulder M3
1.00 158.46 158.46
1.11
25cm thick sound basaltic or equivalent stone hard-core
finished and blinded with crushed stone.
M2 #REF! 137.59 #REF!
Total carried to summary Birr #REF!
2. CONCRETE WORK
2.1 Provide and form 5 cm thick lean concrete class C-5, with
a minimum cement content of 150 kg cement/M3 under :-

a) Footings M2 #REF! 65.25 #REF!


b) Grade beam M2
#REF! 65.25 #REF!
c) Masonry wall M2
#REF! 65.25 #REF!
d) 100mm thick ground floor slab. M2 #REF! 65.25 #REF!
2.2 Provide and form Reinforced concrete C-25, with a
minimum cement content of 360kg cement/M3 filled into
form work and vibrated around reinforcement bar. Steel
and formwork measured separately:-

a) In footings M3 #REF! 2,512.35 #REF!


b) In foundation columns M3
#REF! 2,641.41 #REF!
c) In grade beams M3 #REF! 2,512.35 #REF!
d) In 100mm thick Grand floor slab. M2
#REF! 251.24 #REF!
2.3
Provide, cut and fix sawn zigba wooden or
equivalent steel formwork that should be strong
enough to resist the pressure of fresh concrete and
painted with approved type mould oil before any
placement of concrete is carried. -

a) To footings M2 #REF! 345.20 #REF!

b) To foundation columns M2 #REF! 345.20 #REF!

c) To Grade beams M2 #REF! 345.20 #REF!


2.4 Steel reinforcement according to structural drawing. Price
includes cutting, bending, placing in position bar spacer
and tying wires.

a) Dia 8 mm deformed bar Kg #REF! 37.10 #REF!


b) Dia 12 mm deformed bar Kg #REF! 37.23 #REF!
c) Dia 14 mm deformed bar Kg #REF! 37.23 #REF!
d) Dia 16 mm deformed bar Kg #REF! 37.23 #REF!
e) Dia 20 mm deformed bar Kg #REF! 37.23 #REF!
Total carried to summary Birr #REF!
3. MASONRY WORK
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

3.1 500mm thick hard trachytic roughly dressed stone


masonry foundation wall below ground level bedded in
cement mortar mix ratio (1:3)
M3 #REF! 1,170.42 #REF!
3.2
500mm thick traichytic or equivalent well dressed
stone masonry above natural ground level bedded
in cement mortar (1:3) in full joints. Price shall
include pointing. M3 #REF! 1,457.96 #REF!
Total carried to summary Birr #REF!
Sub Total (A) Carried To Summary Eth. Birr #REF!
B-SUPER STRUCTURE
1. CONCRETE WORK
1.1 Reinforced concrete in C-25, with a minimum cement
content of 360kg cement/M3 filled into form work and
vibrated around reinforcement bar. Steel and formwork
measured separaterly:-

a) In Elevation columns M3 #REF! 2,839.47 #REF!


b) In intermediate and top tie beams M3 #REF! 2,710.64 #REF!
c) In stair case & landing M3 #REF! 2,710.64 #REF!
d) In suspended solid slab M3
#REF! 2,710.64 #REF!
e) In roof slab M3
#REF! 2,710.64 #REF!
1.2 Provide, cut and fix in position sawn structural wood or
steel formwork which ever is appropriate.

a) In Elevation columns M2 #REF! 345.20 #REF!


b) In intermediate and top tie beams M2 #REF! 345.20 #REF!
c) In stair case & landing M2 #REF! 345.20 #REF!
d) In suspended solid slab M2
#REF! 345.20 #REF!
e) In roof slab M2
#REF! 345.20 #REF!
1.3 Steel reinforcement according to structural drawing. Price
includes cutting, bending, placing in postion bar spacer
and tying wires.

a) Dia 8 mm deformed bar Kg #REF! 37.70 #REF!


b) Dia 10 mm deformed bar Kg #REF! 37.23 #REF!
c) Dia 12 mm deformed bar Kg #REF! 37.23 #REF!
d) Dia 14 mm deformed bar Kg #REF! 37.23 #REF!
e) Dia 16 mm deformed bar Kg #REF! 37.23 #REF!
f) Dia 20 mm deformed bar Kg #REF! 37.23 #REF!
Total carried to summary Birr #REF!

2. BLOCK WORK
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

2.1 20cm thick hollow concrete block wall of type Class-


C with 28 days minimum crushing strength of
18kg/cm2, bedded in cement mortar (1:3) mix, both
sides left for plastering. M2 #REF! 438.85 #REF!

2.2 Ditto, as item 2.1 but 15 cm thick class c M2 #REF! 405.46 #REF!

2.3 Ditto, as item 2.1 but 10 cm thick class c M2 #REF! 214.94 #REF!
Total carried to summary Birr #REF!
3. ROOFING
3.1 Apply light weight concrete over roof slab with 2% slope
towards down pipe openings and make ready for water
proofing works (price includes chiseling the surface ).
M2 266.76 112.90 30,117.20
3.2 Spread and level 3cm thick cement sand screed(1:3) on top
of light weight concrete to receive water proofing
M2 266.76 167.71 44,738.32
material.
3.3 Supply and lay a single Plyhertalan or equivalent water-
proofing system (membrane type), manufactured from a
special HERTLAN (EPDM ) rubber compound, shall be
used on the terrace roof. The water-proofing EPDM-
system shall include contact and bonding adhesives,
Sealant roof drain connection and all other necessary
accessories needed to complete the work. The entire work
shall be executed based on details provided by the
manufacturer and approval of the engineer.

M2 266.76 400.00 106,704.00

Total Carried to Summary 181,559.52


4. CARPENTARY & JOINERY
4.1 Supply and fix flush wooden doors covered with 4mm
Kerrero plywood free from knots, scratches and defects.
Door frames shall be 40mm thick in soild Zigba wood,
width of framed shall be as per wall thickness. Provide
cylinderical locks to be approved by the consultant. price
includes all necessary accessaries. Sample door has to be
inspected by the consultant before mass production.

a) D1 Size:- (80 x 210)cm No #REF! 7,892.10 #REF!


b) D2 Size:- (120 x 270)cm No #REF! 6,138.30 #REF!
Total carried to summary Birr #REF!

5. METAL AND ALUMINIUM WORK

5.1 METAL WORK


PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

5.1 Supply and fix 38mm*38mm black iron LTZ section steel
profile frame metal doors including all the necessary
accessories. Unit price includes best quality cylindrical
door lock, one coat of anti-rust and two coats of synthetic
enamel paint all according to the detail drawing:

5.1.1 a) D1 Size: - 70 x 210cm pcs #REF! 4,550.25 #REF!


5.2

Supply & fix in position RHS 50×50×2.5mm,


30×30×2.5mm, 20×20×1.5mm railing for tanker slab in
accordance with drawing & technical specifications. Price
shall include & all necessary fixing accessories including
but not limited to : brackets, flanges, anchors, fasteners,
grouting and anchoring cement. (Height= 80cm) Ml #REF! 2,736.96 #REF!
5.3 ALUMINIUM WORK
All window doors & windows are manufactured from
aluminum profile frames. All works should be cut and
assembled to sizes and shapes of the window and door
schedule upon submitting workshop drawing by the
contractor. Unit price includes 5mm clear glass, anchored
bolts 2mm thick aluminum cover plates, cylindrical key,
door stoppers and other necessary accessories for
completing the work. All according to window door
schedule and as specified.

WINDOW DOORS
a) WD1 Size: - 130*225cm pcs 2.00 -
b) WD2 Size: - 220*200cm pcs 4.00 -
c) WD3 Size: - 235*195cm pcs 1.00 -
d) WD4 Size: - 284*285cm pcs 4.00 -
e) WD5 Size: - 300*295cm pcs 2.00 -
f) WD6 Size: - 320*270cm pcs 1.00 -
WINDOWS
a) W1 Size: - 40*240cm pcs #REF! #REF!
b) W2 Size: - 45*240cm pcs #REF! #REF!
c) W3 Size: - 50*120cm pcs #REF! #REF!
d) W4 Size: - 50*140cm pcs #REF! #REF!
e) W5 Size: - 50*160cm pcs #REF! #REF!
f) W6 Size: - 50*180cm pcs #REF! #REF!
g) W7 Size: - 50*200cm pcs #REF! #REF!
h) W8 Size: - 50*220cm pcs #REF! #REF!
i) W9 Size: - 90*95cm pcs #REF! #REF!
j) W10 Size: - 120*180cm pcs #REF! #REF!
k) W11 Size: - 120*185cm pcs #REF! #REF!
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

l) W12 Size: - 120*190cm pcs #REF! #REF!


m) W13 Size: - 135*175cm pcs #REF! #REF!
n) W14 Size: - 190*180cm pcs #REF! #REF!
o) W15 Size: - 200*175cm pcs #REF! #REF!
p) W16 Size: - 220*175cm pcs #REF! #REF!
q) W17 Size: - 260*175cm pcs #REF! #REF!
r) W18 Size: - 285*75cm pcs #REF! #REF!
s) W19 Size: - 375*120cm pcs #REF! #REF!
t) W20 Size: - 375*167cm pcs #REF! #REF!
DOORS
a) D1 Size: - 90*270cm pcs 16 -
b) D2 Size: - 90*285cm pcs 3 -
c) D3 Size: - 120*270cm pcs 2 -
5.4
Supply & fix in position Aluminum railing for stair case
and balconies in accordance with drawing & technical
specifications. Price shall include & all necessary fixing
accessories including but not limited to : brackets, flanges,
anchors, fasteners, grouting and anchoring cement.
(Height= 80cm) Ml #REF! 750.00 #REF!
TOTAL CARRIED TO SUMMARY ...... #REF!

6. FINISHING
Finishing work shall include all surface pre-cleaning,
Preparation and application of the finish, polishing and
cleaning at the end of finished work.

6.1 Apply three coats of plaster in cement sand mortar ratio


of (1:3) to internal HCB wall . Price includes exposed
concrete beams & columns with edge works and which
quality approved with engineer.
M2 #REF! 308.98 #REF!

6.2 Ditto item 6.1 to but for concrete ceiling , stair & landing
soffit . M2 #REF! 308.98 #REF!

6.3 Apply three coats of plaster in cement sand mortar ratio


of (1:3) to external HCB wall . Price includes edge works
and which quality approved with engineer.
M2 #REF! 343.15 #REF!
6.4 Apply two coats plastering with cement and mortar Mix
1:3) to receive glazed ceramic wall tile.
M2 #REF! 237.06 #REF!
6.5 Apply 48 mm thick Cement screed floor finish in cement
sand mortar (Mix 1:3) to receive PVC floor tile. M2 #REF! #REF!
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

6.6 Supply and lay 30 x 30 x 0.2 cm thick PVC tile floor


bedded with approved type glue on top of cement sand
screed .
M2 #REF! #REF!

6.7 30x30x0.6cm thick Non- Slippery Ceramic tile flooring for


toilets and corridor bedded and jointed in cement mortar
(1:3 mix).
M2 #REF! 661.67 #REF!

6.8 Supply and fix polished granite tile bedded on cement


sand mortar (1:3) mix and grouting joints for stair case.
M2 #REF! #REF!
6.9 Supply and lay 30 x30 x 0.4 cm white glazed ceramic wall
tile bedded in cement sand mortar of (1:3) mix ratio to a
full hight for toilet ,kitchen and shower. Price includes
Joint shall be grouted in white cement.
M2 #REF! 556.19 #REF!
6.10 Supply and fix 10 cm hight PVC skirting to wall with
approved type material bedded with glue.
Ml #REF! #REF!
6.11 Supply and fix in place 10 cm high non-slippery ceramic
skirting to wall bedded in cement sand mortar (mix 1:3)
Ml #REF! 150.64 #REF!
6.12 Supply and fix 10cm high glazed porcelain skirting.
Ml #REF! #REF!
6.13 270x20mm throated and bullnosed White marble window
sill bedded in cement mortar (1:3) mix. It shall be
chamfered at the edge, provide water drip at bottom face
of cill and 2% slope towards outside. All according to the
detailed drawing.
Ml #REF! #REF!
6.14 Supply and fix polished granite for stair case bedded on
3cm thick cement sand mortar (1:3) mix and grouting
joints for stair case.

a) Tread 30x340mm Ml #REF! 750.00 #REF!


b) Risers 20x140mm Ml #REF! 650.00 #REF!
6.15 Apply 4.2cm thick cement screed (1:3) mix ratio to receive
Porcelain floor tile. M2 #REF! #REF!
6.16 Supply and fix 50x50x0.8cm unglazed and non-slipery
Porcelain floor tile stuck to screed, price shall include
good quality adhesive.
M2 #REF! #REF!
6.17 250x30mm throated and weathered marble door threshold
bedded in cement mortar (1:3) mix.
Ml #REF! #REF!
Total carried to summary Birr #REF!
7. PAINTING
7.1 Apply three coats of plastic paint to internal plastered
wall surfaces, columns and beams. M2 #REF! 64.17 #REF!
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

7.2 Ditto item 8.1 but, to R.C slab,stair case ,landing, soffit. M2 #REF! 72.81 #REF!
-
7.3 Apply approved type quartz paint to all external
plastered HCB & structure surfaces as located in the
drawing. Price shall one coat of prime.
M2 #REF! 26.00 #REF!
Total carried to summary Birr #REF!
8. GLAZING
8.1
4mm thick clear glass glazed to metal beads & including
good quality putty. (At the top of flush wooden doors). M2 #REF! 490.35 #REF!
Total carried to summary Birr #REF!

9. ELECTRICAL INSTALLATION
9.1 All distribution boards , breakers , switches, accessories
etc should be genuine Legrand , ABB, Siemens or
approved equivalents complying with IEC standards.
Distribution boards should be made of sheet metal and
have separate neutral and ground busbars/phase bars.All
units in the distribution boards should should be labled to
give the reference and duty of the unit.

9.1.1 Semi Flush mounted main distribution board GFMDB


with lockable door, bus-bars rating of 125A/3ph and
with all its accessories consisting of :-

1pcs MCCB of 100A/3ph Icu=16ka


1pcs MCB. of 40A/3ph Icu=10ka
1pcs MCB. of 32A/3ph Icu=10ka
10 pcs MCB. of 16A/1ph Icu=6ka
9 pc s MCB.of 10A/1ph Icu=6ka
1 pcs MCB. of 10A/3ph Icu=10ka
and with 20% reserve space.
No 1 7,618.78 7,618.78
9.1.2 Flush mounted sub distribution board 1FSDB with
lockable door, phase-bar rating of 40/3ph and with all its
accessories consisting of :-

1 pcs MCB. of 32A/3ph Icu=10ka


10 pcs MCB. of 16A/1ph Icu=6ka
9 pcs MCB. of 10A/1ph Icu=6ka
and with 20% reserve space. No 1 3,133.85 3,133.85
9.1.3 Flush mounted sub distribution board 2FSDB with
lockable door, phase-bar rating of 50A/3ph and with all
its accessories consisting of :-

1 pcs MCB. of 40A/3ph Icu=10ka


1 pcs MCB of 25A/1ph Icu=6ka
12pcs MCB. of 16A/1ph Icu=6ka
8 pcs MCB. of 10A/1ph Icu=6ka
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

and with 20% reserve space. No 1 4,641.53 4,641.53


9.2 Light point fed through PVC insulated copper conductors
of 2x2.5 sq.mm in thermoplastic conduit of minimum
diameter 13 mm in/or under surface including junction
box with cover and screw type insulating connectors

No 251 205.00 51,455.00


9.3 Type of flush mounted switches
9.3.1 Single pole switch suno type or equivalent
No 23 56.07 1,289.61
9.3.2 Double pole switch suno type or equivalent No 56 80.07 4,483.92
9.3.3 Two way switch suno type or equivalent No 18 67.01 1,206.18
9.3.4 intermidate switch suno type or equivalent No 5 91.07 455.35
9.4 Type of Light Fittings or Approved Equivalents
9.4.1 PHILIPS TCS 098/236 IC C3 with 2x'TL' D 36W/830
lamps.or equivalent No 135 1,152.78 155,625.30
9.4.2 PHILIPS TCS 098/136 IC C3 with 1x'TL' D 36W/830
lamp.or equivalent No 67 910.28 60,988.76
9.4.3 PHILIPS TCS 098/4x18 with 4x'TL' D 18W/ 830 lamp.or
equivalent
No 7 1,142.78 7,999.46
9.4.4 PHILIPS TCS 098/2x18 with 2x'TL' D 18W/ 830 lamp.or
equivalent No 1 500.00 500.00
9.4.5 RZB55152 with 1x60W clear standard incandescent
lampor equivalent
No 29 224.02 6,496.58
9.4.6 RZB55154 with 1x60W clear standard incandescent
lamp.or equivalent
No 12 224.02 2,688.24
9.5 Flush mounted socket outlets of 10A/1ph fed through
PVC conductors of 3x2.5 sq.mm in thermoplastic conduit
of minimum f 16mm in/under surface including junction
box with cover and screw type insulating connectors.
No 108 280.00 30,240.00
9.5.1 Ditto as item No 6 but 16A/1ph for hand drayer No 6 280.00 1,680.00
9.5.2 Ditto as item No 6 but 16A/1ph for soap despenser No 6 280.00 1,680.00
9.5.3 Ditto as item No but of 16A/1ph with switch and pilot
lamp indicator for water heater.
No 3 365.31 1,095.93
9.6 Ditto as item No 1.11 but of 20A/1ph fed through PVC
conductors of 3x6 sq.mm in thermoplastic conduit of
minimum diameter 21mm with on/off switch Coffee
machine
No 1 1,045.97 1,045.97
9.7 Telephone points with wire pulling cord in thermoplastic
conduits of minimum f 29mm with Telephone socket out
let
No 35 218.10 7,633.50
9.8 Tele riser with wire pulling cord in thermo plastic
conduit minimum diameter 32mm tentatively
ML 15 15.47 232.05
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

9.9 lay pvc pipe diameter 50mm for tele entry in/under
surface tentatively
ML 8 25.17 201.36
9.1 Supply power from GFMDB-T0-1FSDB through PVC
insulated copper cable of 4x10+10 sq.mm in PVC PIPE
minimum diameter 40mm in/under surface tentatively
ML 18 162.17 2,919.06
9.11 Supply power from GFMDB -to-2FSDBthrough PVC
insulated copper cable of 4x16+16 sq.mm in thermoplastic
conduit of minimum f 40mmIn/under surface tentatively
ML 6 228.42 1,370.52
8.12 Earthing electrode1500x16mmtype furse RB210 complete
with coupling driven stud
No 3 466.79 1,400.37
9.13 Lay pvc insulated copper conductor of 1x16mm2
in/under surface in thermoplastic conduit 25mm
in/under surface form GFMDB to earth electrode
tentatively
ML 16 66.60 1,065.60
9.14 Tele terminal box 30x20x7cm made of plastic junction box
No 3 110.00 330.00
Lighting prevent or type pulsar or equivalent p3 H[m]=4
9.15 Rp(M)=87 No 1 25,980.50 25,980.50
9.16 Copper tape 25x3mm with clips to fix on the wall.and
with adesive tape on the roof tentatively

ML 65 251.07 16,319.55
9.17 Test point
No 2 251.07 502.14
9.18 Bare copper stranded wire 1 x 70mm2 tentatively
ML 6 175.50 1,053.00
9.19 MAN HOLES
Construct manholes with HCB wall 200mm thick on mass
concrete bed of 100mm, with inside walls to be plastered
in two coats of cement mortar, with reinforced concrete
slab cover of 60mm thick , steel bar handle and having
internal dimensions of :- 60x60x50cms

No 1 800.00 800.00
9.19.1 Construct manholes with brick wall 250mm thick on mass
concrete bed of 100mm, with inside walls to be plastered
in two coats of cement mortar, with reinforced concrete
slab cover of 60mm thick , steel bar handle and having
internal dimensions of :- 60x60x50cms.

1 1,000.00 1,000.00
9.20 Lay cement pipeф 10cm for power entry tentatively
ML 10 70.00 700.00
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

9.21 supply and lay pvc insulated copper conductor 4x1.5mm2


inthermoplastic conduit minimum diameter 25mm to
pump house in/under floor tentatively

ML 20 39.00 780.00
Total carried to summary Eth birr 406,612.11
10. SANITARY INSTALLATION
10.1 SANITARY FIXTURES
All fixtures and pipes which are specified below shall
subject to the Consultants or Owner's approval based
on samples, brochures and catalogues presented by
the contractor. Unit Price shall include all the
necessary fixing brackets or hooks and all assistnace
civil works such as chiselling of walls, floors, beams
etc…
10.1.1 Supply and fix AQUA Hand Wash Basin made of
white vitreous China with chrome plated. The fixture
shall conform to BS5506-3 or equivalent institution.
The taps, chrome plated brass p-trap, waste fittings,
connecting pieces, fixing & supporting elements and
other accessories which complete the set shall comply
with the relevant clauses of BS standard or equivalent
institution.

Type AQUA Ceramics or equivalent


a) 505 x 405mm normal No 27 2963.07 80,002.89
10.1.2 Supply and fix AQUA or equivalentWater Closet
(WC) of wash down action,floor mounted (S-Trap),
close coupled, made of white vitreous China The
fixture shall conform to BS5503-2 or equivalent
institution. The plastic seat cover, low flush cistern,
waste fittings, connecting pieces, fixing & supporting
element and other accessories which complete the set
shall comply with the relevant clauses of BS standard
or equivalent institution.

a) Size 670 x 365mm No 30 2963.07 88,892.10


10.1.3 Supply and fix AQUA Toilet Paper Holder made
of white vitrous china (BS3402), of approved quality
complete with all the necessary accessories.
a)Size 185 x 115mm No 30 379.37 11,381.10
10.1.4 Supply and fix approved quality swing pattern
Towel Hanger made of chrome plated copper alloys,
single tubular, surface mounted,bar length of 600mm
with 3mm minimum thickness near shower
complete with fastening screws white vitreous china
ceramic support and other accessories. No 2 379.37 758.74
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

10.1.5 Supply and fix AQUA Soap Holder , approved


quality made of white vitrous china (BS3402), for
shower units complete with all the necessary
accessories.
Size 225 x 110mm No 2 379.37 758.74
10.1.6 Supply and fix stylish framed crystal glass mirrors
for hand wash basins with copper back protection,
including chrome plated brass mirror clips with
chrome plated screws & etc.Price shall also include
approved quality shelves.
a) 500 x 400mm No 27 855.37 23,094.99
10.1.7 Supply,fix ,test and commission Bath Tub unit made
of enamelled cast iron,with slip resistant base
including chrome plated mixing faucet togther with
telephone type shower head,Smell-trap with proper
water seal and all required accessories there to
a) Bath Tab
Approximate Size 1800 x 800mm
Color: As per the Architect's preference or equivalent
approved by the engineer No 2 -
10.1.8 Supply and fix ARISTON OR Equivalent Electric
Water Heater with a capacity given below.Complete
with all water proofing, mounting and fastening
material, safety, one-way valve, approved quality coil
and gate valve and with all the accessories.Heat
preservation hot water tank in gallbladder,thickness
1.0mm, outer covering thickness 0.6mm,foam
polyurethane 50mm thick, outside protective layer:
stainless steel.

50 Litre capacity No 2 6801.54 13,603.08


10.1.9 Supply and mount 6kg Fire Extinguishers of carbon
dioxide type on accessible locations complete with
brackets and all approved standards (exceptionally
effective on class B & E fire).Unit price shall include
all the necessary assistance work. No 5 1461.45 7,307.25
10.2 WATER SUPPLY PIPES AND VALVES
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

10.2.1 Supply, lay install and commission approved quality


RAK TERM PPR pressure pipes (PN20), for hot &
cold water distribution system to sanitary fixtures.
The pipes shall be complete with all the necessary
connecting pieces such as bends,Ys, Ts, reducers,
nipples, unions, hangers & supported with
compatible clips all as per manufacturer's
recommendation to the walls, floors, slabs,beams,
ceilings, etc…Unit price shall include, disinfection of
the pipes with Chlorine and all the necessary
assistance to the installation works. The installation
shall be tested at a pressure of 10kg/cm2 at the
expense of the contractor. The pipes and fittings shall
conform to BS3505/DIN8062 or equivalent
institution.The PPR pipe shall be UV resistant at the
exposed areas. Pipe sizes are external.

Dia 20 mm ml 60.0 282.68 16,960.80


" 25 " ml 7 370.00 2,590.00
" 32 " ml 32 489.39 15,660.48
10.2.2 Supply and fix RAK PPR ball Valves of approved
standard,on water supply distribution lines where
shown on the drawing The valves shall be
compatable with PPR pipes and complete with
adaptors,unions, elastic water proofing , hand wheels
of normal quality and all other necessary accessories.
Diameter 20mm No 27 1046.21 28,247.67
10.2.3 Supply and fix RAK Pressure Reducing Valve of
approved standard,on water supply riser lines where
shown on the drawing The valves shall be
compatable with PPR pipes and complete with a all
necessary accessories.
Diameter 50 mm No 2 2017.81 4,035.62
10.2.4 Supply and fix 20mm dia, PN 20 chrome plated brass
RAK quarter turn angle valves with chrome plated
copper connecting pipe, union nut and chrome
plated brass wall flanges, and accessories complete in
all respects. The Angle valve should be capable
resisting of PN-20 before hand washbasins, water
closets, sinks and other fixtures. No 27 526.75 14,222.25
10.3 WASTEWATER PIPES AND ACCESSORIES
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

All domestic waste, vent and storm water pipe lines


shall be uPVC pipes and shall be provided with a
minimum slope as indicated on the drawing towards
the outlet unless specified. All uPVC pipes and
necessary fittings shall be standard quality and be
free from damage during storage, transportation,
construction etc. Unit price shall include all the
necessary assistance civil works, such as excavation
cartaway, fixing or hanging to walls, beams or slabs.
etc., necessary fittings such as bends, Y, T, etc. Storm
water PVC pipes shall resist the external temperature
and the quality shall meet the purpose.

10.3.1 Providing, laying ,cladding and jointing of internal


and external uPVC PN-6 waste pipes with all uPVC
pipe fittings including jointing with solvent cement
joints and testing of joints etc. according to where
shown on the drawings. Complete with all the
necessary fittings. Provide cleaning detail for all
waste water riser pipes as per the detail drawing.
a) Diameter 50 mm ml 44 403.89 17,771.16
b) Diameter 110 mm ml 192 576.87 110,759.04
10.3.2
Supply and fix EQUIVALENT floor drains made of
polished steel of approved quality, complete with P-
smell trap and all other necessary fittings and
accessories. Type & model shall be approved by the
consultant prior to installation.
Size:- Dia. 50 mm No 12 509.73 6,116.76
10.3.3 Supply and install vent caps made of rigid uPVC to
be connected to the roof terminal of vent pipe. Unit
price shall include flushing works to prevent roof
leakage: - No 4 185.86 743.44
a) Size: - Dia.50mm
10.4 ROOF RUNOFF DRAINAGE SYSTEM
10.4.1 Supply and fix uPVC(PN 6) Downpipes min. wall
thickness 3.2mm,with mass concrete support at
ground level and complete with basket strainer at
inlet, galvanized clips at every elbows,joints and at
every 1m interval complete with all accessories.The
pipes, accessories, fittings & method of welding shall
comply with the requirement of BS 4514or equivalent
Institution. Unit price shall include all the necessary
assistances to the installation works.

a) Size: - Dia.110mm ml 142 622.38 88,377.96


10.5 ROOF WATER TANK
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

10.5.1 Supply, lay & connect HDPE Pipes (PN -20) for
water supply, as shown on the drawing. Complete
with all the necessary connecting pieces such as
elbow, Tee, unions, etc The installation shall be tested
at a pressure of 10kg /cm² at the expense of the
contractor. The pipe shall comply with DIN-8074,
DIN-8075 or related international quality standards
a) Ø32mm ml 47.0 -
a) Ø40mm ml 17.0 -
b) Ø50mm ml 33.0 602.58 19,885.14
10.5.2 Supply, fix, test and commission EQUIVALENT
Bronze Gate valves, PN 20, of approved Standards &
quality, and the same brand of the pipe, on the water
supply Riser Branch lines to rooms with sanitary
provissions, as where shown on the drawings.
Complete with all required fittings and accesseries
there to.
Diameter 32mm No 4 -
Diameter 40mm No 1 -
Diameter 50mm No 3 2267.01 6,801.03
10.6 FIBER GLASS WATER TANK
10.6.1 Supply and place properly (fix) 3m3 SUPER water
tank where as shown on the sanitary site plan, made
of 5 mm thick fiber glass including all the necessary
connecting fittings and pipes such as outlet pipe with
gate valve, inlet pipe with gate valve, drain pipe with
gate valve, over flow pipe, vent pipe including
manhole cover and vent cape.Provide manhole with
a strong ,lockable and easily openable cover (lid) just
above the inlet pipe.Complete with :-

-Diameter 50mm inlet HDPE pipe (PN20) with


bronze gate valve and float valve.
-Diameter32mm, 40mm & 50mmoutlet pipe HDPE
(PN20) with bronze gate valve
-Diameter 32mm drain pipe with gate valve ( 16
bar )
-Diameter 40mm over flow pipe
-Diameter 40mm uPVC vent pipe with mesh cover
and cape.
-70cm*70cm manhole cover
•Sufficient free board and sludge zone for air
circulation, proper functioning of the float valve
(ball) and accumulation of the accidentally
entering solid particles respectively.
•Strong solid supporting legs ( no space for
water to be retained inside).
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT
•Prior to the approval of the material submittal of the
detail drawings of the tank is mandatory.
complete with all accessories.
•The fiber glass shall be warranted by the supplier
against all defects and malfunction of materials and
workmanship for a period of Ten years from the
date of completion of works. If problems
arise with the system during the warranty period,all
necessary repairs or replacement shall be made by
the contractor in an expendient manner at no
additional cost pcs 1.00 19828.30 19,828.30
10.6.2 FIBER GLASS GROUND WATER TANK
Supply and place properly (fix) 5m3 water tank
where as shown on the sanitary site plan, made of 5
mm thick fiber glass including all the necessary
connecting fittings and pipes such as outlet pipe with
gate valve, inlet pipe with gate valve, drain pipe with
gate valve, over flow pipe, vent pipe including
manhole cover and vent cape.Provide manhole with
a strong ,lockable and easily openable cover (lid) just
above the inlet pipe.Complete with :-

-Diameter 50mm inlet pipe HDPE (PN20) with


bronze gate valve and float valve.
-Diameter 50mm outlet pipe HDPE (PN20) with
bronze gate valve
-Diameter 32mm drain pipe with gate valve ( 16
bar )
-Diameter 40mm over flow pipe
-Diameter 40mm uPVC vent pipe with mesh cover
and cape.
-70cm*70cm manhole cover
•Sufficient free board and sludge zone for air
circulation, proper functioning of the float valve
(ball) and accumulation of the accidentally
entering solid particles respectively.
•Strong solid supporting legs ( no space for
water to be retained inside).
•Prior to the approval of the material submittal of the
detail drawings of the tank is mandatory.
complete with all accessories.
•The fiber glass shall be warranted by the supplier
against all defects and malfunction of materials and
workmanship for a period of Ten years from the
date of completion of works. If problems
PROJECT :- ARMY FOUNDATION

BLOCK :- CENTRAL COMMAND

LOCATION :- SHIRE
No DESCRIPTION UNIT QTY RATE AMOUNT

arise with the system during the warranty period,all


necessary repairs or replacement shall be made by
the contractor in an expendient manner at no
additional cost pcs 1.00 19828.30 19,828.30
10.7 WATER PROOF & LIGHT WEIGHT CONCRETE WORK
10.7.1 Apply cementious water proofing material for toilet
room floors & to a height of 300mm on walls and
columns as per the manufacturer's instruction. The
cost shall include cleaning of all dirts, trace of grease,
oil and loose particles. The work shall be done on
subcontractual bases with the supplier of the material
which will give material & construction gurantee to
the client.
m
2 87 390.74 33,994.38
Total carried to summary birr-------------- 631,621.22
SUMMARY OF BILL OF QUANTITIES

CALIBRATION CENTER OFFICE WORK


A. SUPER STRUCTURE

1 STRUCTURAL STEEL WORK........................................ ETH. BIRR -


2 ROOFING .............................................................. ,, ,, -

3 METAL AND ALUMINIUM WORK ..............................,, ,, -


4 GLAZING………………………………………… ,, ,, -
TOTAL A ,, ,, -
15% VAT ,, ,, -

CONTIGENCY (8%) ,, ,, -

GRAND TOTAL ,, ,, -

1
PROJECT :- CALIBRATION CENTER OFFICE WORK
CONSULTANT:- DCDE
LOCATION :- ADDIS ABABA
ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.
1. STRUCTURAL STEEL WORKS
Supply and erect steel structure all as shown on
the detail drawing. Apply two coats of antirust
paint. Price includes all necessary preparation
work such as cleaning, wire brushing and finally
two coats of anti-rust paint.

1.1 RHS size of 20x40x2mm kg 17,451.49 -


1.2 RHS size of 20x40x3mm kg 135.65 -
1.3 RHS size of 30x40x3mm kg 103.62 -
1.4 SHS size of 40x40x3mm kg 1,019.87 -
1.5 RHS size of 40x50x3mm kg 69.08 -
1.6 SHS size of 50x50x3mm kg 529.88 -
1.7 SHS size of 60x60x3mm kg 226.08 -
1.8 RHS size of 70x50x3mm kg 2,303.50 -
1.9 SHS size of 80x80x3mm kg 4,650.21 -
1.10 1100x1100x3mm galvanized steel chekered
plate welded to RHS as shown on drawing. No 1 -
1.11 1200x300x3mm galvanized steel chekered
plate welded to RHS as shown on drawing. No 18 -
1.12 3000 X 1100 X 3mm galvanized steel chekered
plate welded to RHS as shown on drawing. No 1 -
1.13 200x200x8mm steel plate welded RHS and
fixed to anchor bolt as shown on drawing. No 112 -
1.14 100x70x3mm connecting steel plate. No 62 -
1.15 Threaded J-shaped ancorage M-14 bolt of dia.
49mm grade 8.8 L=165mm. No 112 -
1.16 Grade 8.8 M12 threaded anchor bolt of
diameter- 49mm connecting RHS beam and No 112 -
column.
TOTAL CARRIED TO SUMMARY ....... -

2
PROJECT :- CALIBRATION CENTER OFFICE WORK
CONSULTANT:- DCDE
LOCATION :- ADDIS ABABA
ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.
2. ROOFING
2.1 Supply cut and fix in position EGA-500
0.35mm thick sheet metal in roof cover all as
shown on structural drawings and as
specified in the technical specifications. metal
sheet shall be Carbon Steel complying with
the requirements of BS 4360 or ASTM A 36M.
Headed Bolts shall be ASTM A 307, grade A
or ASTM F 568, Property Class 4.6. Welded
connections shall comply with AWS D1.1 for
procedures, appearance and quality of welds,
& methods used in correcting welding works.
Price shall include one coat of fast curing, rust
inhibiting, non-asphaltic, lead and chromate-
free, universal modified-alkyd primer with
performance complying with the
requirements of FS TT-P-664, two coats of
synthetic enamel paint and paint thinner.
m2 266.76 -
2.2 Supply and erect steel roof truss and purlin all
as shown on the detail drawing. Apply two
coats of antirust paint. Price includes all
necessary preparation work such as cleaning,
wire brushing and finally two coats of anti-
rust paint.
Upper, lower, vertical & diagonal member as
specified on the drawing.
a) SHS size of 60x60x3mm Upper chord kg 6,491.60 -
b) RHS size of 70x50x3mm Lower chord kg 6,813.80 -
c) SHS size of 40x40x3mm vertical and
diagonal members. kg 4,327.35 -
d) SHS size of 40x40x3mm purlin. kg 4,149.82 -
2.3 Supply and fix G-28 galvanized metal sheet gutter
of development length 97cm spliced at joints.
ml 12 -
2.4 Ditto item 3.2 but 87cm development length. ml 24 -
2.5 Supply and fix diameter 110mm galvanized
sheet metal downpipe secured to wall with
metal straps spaced every 800mm price shall
include two coats of anti rust paint
ml 30 -
2.6 Supply and fix 600mmx600mm size
"Armstrong" or equivalent approved type of
ceiling in dunma complete with suspention
system and accessories as per manifacturer.
Price shall include all accessories to complete
the work.
m2 248.98 -
TOTAL CARRIED TO SUMMARY .......
-

3
PROJECT :- CALIBRATION CENTER OFFICE WORK
CONSULTANT:- DCDE
LOCATION :- ADDIS ABABA
ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.
3. METAL AND ALUMINIUM WORK
3.1 METAL WORK
3.1.1 Supply and fix stainless steel guardrail (CHS
Ø50mm and 1.2mm thick for handrail , RHS
35x25x1.2mm c/c 1m vertical member
and.Ø19mm and 1mm thick c/c 180mm
horizontal member). Price includes all
necessary fixing accessories.
ml 60.00 -
3.2 ALUMINIUM WORK
3.2.1 Supply, fabricate and fix 2mm thick anodized
aluminium window with 5mm thinted glass.
The anodization thickness should not be less
than 0.5µm. Price includes best quality hinges,
hardwares to complete the work as per
window schedule.

WINDOWS 0.00
a) W1 Size: - 338×210cm pcs 10 -
b) W2 Size: - 540×210cm pcs 2 -
c) W3 Size: - 605×210cm pcs 1 -
d) W4 Size: - 219×210cm pcs 1 -
e) W5 Size: - 420×210cm pcs 1 -
3.2.2 Provide and fix Aluminium Doors made of
2mm thick anodized aluminium profile with
5mm thick thinted glass including hinges,
handles and all accessories, cylinder lock and
hardware all to be high quality and approved.
The anodization thickness should not be less
than 0.5µm. Price shall include 4mm thick
aluminium composite and all the necessary
accessories as per detail drawings.

DOORS 0.00 0.00


a) D1 Size: - 90×210cm pcs 1 -
3.2.3 Supply, fabricate and fix 4mm thick
aluminium composite material wall cladding.
The aluminium sheet should not be less than
0.5mm in thickness for both sides.

a) For external wall cladding.


M2 373.05 -
b) For internal wall cladding.
M2 163.55 -
TOTAL CARRIED TO SUMMARY .......... -
4.GLAZING
4.1 Supply and fix approved type of frosted vinyl
film sticker with self adhesive or equivalent
for glass wall cladding at ground floor. M2 110.00 -
TOTAL CARRIED TO SUMMARY ..........
-

4
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

A. SUB-STRUCTURE
1.EXCAVATION & EARTH WORKS
1.1 Site clearing and removing of the top soil with an
average depth of 200mm. . m2 #REF! 13.72 #REF!
1.2 Bulk excavation in ordinary soil to reduce level to
an average depth 400mm from natural ground
level.
A) In ordinary soil m3 #REF! 78.34 #REF!
B) In soft rock m 3
1.00 95.37 95.37
C) In hard rock m3 1.00 591.21 591.21
D) In boulder m 3
1.00 465.40 465.40
-
1.3 Excavate in ordinary soil for trench masonary to a
depth not exceeding 1500mm from stripped level.
A) In ordinary soil m3 #REF! 230.28 #REF!
B) In soft rock m3 1.00 240.76 240.76
C) In hard rock m3 1.00 602.93 602.93
D) In boulder m3 1.00 510.80 510.80
-
1.4 Excavate in ordinary soil for isolated footing to a
depth not exceeding 1500mm from stripped level.
A) In ordinary soil m3 #REF! 230.28 #REF!
B) In soft rock m3 1.00 240.76 240.76
C) In hard rock m3 1.00 602.93 602.93
D) In boulder m3 1.00 510.80 510.80
-
1.5 Ditto item 1.3 but exceeding 1500mm and not
exceeding 3000mm .
A) In ordinary soil m3 #REF! 316.21 #REF!
B) In soft rock m3 1.00 353.11 353.11
C) In hard rock m3 1.00 680.72 680.72
D) In boulder m3 1.00 523.58 523.58

1.6 `
Backfill with selected borrowed granular non
expansive material from quarry, around footings
and foundation column to maintain the desired
level and compact in layers not exceeding 200mm. m3 #REF! 469.53 #REF!
1.7 Backfill with selected borrowed granular non
expansive material from quarry, around stone
masonary to maintain the desired level and
compact in layers not exceeding 200mm.
m3 #REF! 469.53 #REF!
1.8 Backfill with selected borrowed granular non
expansive material from quarry, under hard core to
maintain the desired level and compact in layers
not exceeding 200mm. m3 #REF! 469.53 #REF!
-

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

1.9 Load and cart away surplus excavated material to


an appropriate pit not less 10km away from site and
spread it at the disposal site. m3 #REF! 68.02 #REF!
1.20 Ditto item 1.9 but cart away boulder. m 3
1.00 158.46 158.46
1.21 250mm thick sound basaltic or equivalent stone
hard-core well rammed, consolidated and blinded
with crushed stone. m2 #REF! 137.59 #REF!
TOTAL CARRIED TO SUMMARY ....... #REF!
2.CONCRETE WORKS
2.1 50mm thick lean concrete in C-5 with minimum
cement content of 150kg/m3 of concrete under:

a) Footing m2 85.73 90.68 7,774.00


-
-
b) Grade Beam m2 92.57 90.68 8,394.25
--
c) Stone masonry m2 72.14 90.68 6,541.66
-
d) 100mm thick Ground floor slab m2 539.57 90.68 48,928.21
-
2.2 Reinforced concrete in class C-25 (28-day 150mm
cube crushing strength of 25MPa) with minimum
cement content of 360kg/m3 and maximum
aggregate size of 30mm for footings and 20mm for
columns, beams & slabs; cast into formworks and
vibrated around rod reinforcement bars.( formwork
& reinforcement bars are measured
separately)."Type of cement to be ordinary portland
cement (OPC)" in: -
-
a) Footing m3 47.34 2,329.88 110,296.52
-
b) Foundation column m3 16.89 2,329.88 39,351.67
-
c) ground floor beam m3 40.40 2,329.88 94,127.15
-
d)100mm thick Gound floor slab m2 539.57 232.99 125,714.41
-
e) entrance staircase m3 0.98 2,329.88 2,283.28
-
2.3 Provide, cut and fix sawn zigba wooden or
equivalent formwork that should be strong enough
to resist the pressure of fresh concrete and painted
with approved type mould oil before any placement
of concrete is carried.

a) Footing m2 147.12 185.00 27,217.20


-
b) Foundation column m2 222.39 185.00 41,142.15
-
c) ground floor beam m2 326.60 185.00 60,421.00
-

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

d) entrance stair case m2 2.71 185.00 501.35

2.4 Mild steel reinforcement bar according to structural


drawings. Price includes cutting, bending, placing
in position and tying wire. Bars should be free from
such coatings such as oil and mortar before which
are placed -
-
a) dia. 8mm deformed bar kg 3,685.00 37.45 138,003.25

b) dia. 10mm deformed bar kg 0.00 37.45 -


-
c) dia. 12mm deformed bar kg 1,805.00 35.69 64,420.45
-
d) dia. 14mm deformed bar kg 2,699.00 35.69 96,327.31

e) dia. 16 mm deformed bar kg 714.00 35.69 25,482.66

f) dia. 20 mm deformed bar kg 5,271.00 35.69 188,121.99

g) dia. 24 mm deformed bar kg 0.00 35.69 -

TOTAL CARRIED TO SUMMARY ....... 1,085,048.51


3. MASONRY WORKS

3.1 500mm thick stone masonry foundation wall below


ground level bedded in cement mortar (1:3) in full
joints. m3 90.18 1,286.61 116,026.49
-
3.2 500mm thick traichytic or equivalent well dressed
stone masonry above natural ground level bedded
in cement mortar (1:3) in full joints. Price shall
include pointing. m3 30.10 1,680.90 50,595.09
-
TOTAL CARRIED TO SUMMARY ....... 166,621.58

B. SUPER-STRUCTURE

1. CONCRETE WORKS
1.1 Reinforced concrete in class C-25 (28-day 150mm
cube crushing strength of 25MPa) with minimum
cement content of 360kg/m3 and maximum
aggregate size of 30mm for footings and 20mm for
columns, beams & slabs; cast into formworks and
vibrated around rod reinforcement bars.( formwork
& reinforcement bars are measured
separately)."Type of cement to be ordinary portland
cement (OPC)" in:

a) Elevation column m3 81.37 2,329.88 189,582.34


-
b) Intermediate & top tie beams m3 142.56 2,329.88 332,147.70
-

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

c) 150mm thick suspended solid floor slab m2 2,146.57 349.48 750,183.29


-
d)150mm thick conceret roof slab m3 552.52 349.48 193,094.69
-
e) stair case m3 30.91 2,329.88 72,016.60
-
1.2 Provide, cut and fix sawn zigba wooden or
equivalent formwork that should be strong enough
to resist the pressure of fresh concrete and painted
with approved type mould oil before any placement
of concrete is carried.
-
-
a) Elevation column m2 1,069.75 185.60 198,545.60
-
b) Floor & top tie beams m2 1,295.48 254.58 329,803.30
-
c) 150mm thick suspended solid floor slab m2 2,146.57 254.58 546,473.80
-
d) 150mm thick concerete roof slab m2 552.52 254.58 140,660.55
-
e) stair case m2 257.00 254.58 65,427.06
-
1.3 Reinforcement steel bars according to structural
drawing. Price includes cutting, bending, placing in
position and tying wires. -
-
a) dia. 6mm plain bar kg 0.00 37.45 -
-
b) dia. 8mm deformed bar kg 21,234.00 37.45 795,213.30
-
c) dia. 10mm deformed bar kg 15,041.00 37.45 563,285.45
-
d) dia. 12mm deformed bar kg 2,004.00 35.69 71,522.76
-
e) dia. 14mm deformed bar kg 10,626.00 35.69 379,241.94
-
f) dia. 16mm deformed bar kg 11,199.00 35.69 399,692.31
-
g) dia. 20mm deformed bar kg 11,710.00 35.69 417,929.90
-
h) dia. 24mm deformed bar kg 0.00 35.69 -
-
TOTAL CARRIED TO SUMMARY ....... 5,444,820.59

2. BLOCK WORK
2.1 200mm thick hollow concrete block wall of type
Class-C with 28 days minimum crushing strength
of 18kg/cm2, bedded in cement mortar (1:3) mix,
both sides left for plastering. m2 2,228.00 227.76 507,449.28
-
2.2 Ditto but to 150mm thick HCB walls. m2 919.50 214.94 197,637.33
-
TOTAL CARRIED TO SUMMARY ....... 705,086.61

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

3. ROOFING

3.1 Supply cut and fix in position EGA-40 sheet metal


in roof cover all as shown on structural drawings
and as specified in the technical specifications.
metal sheet shall be Carbon Steel complying with
the requirements of BS 4360 or ASTM A 36M.
Headed Bolts shall be ASTM A 307, grade A or
ASTM F 568, Property Class 4.6. Welded
connections shall comply with AWS D1.1 for
procedures, appearance and quality of welds, &
methods used in correcting welding works. Price
shall include one coat of fast curing, rust inhibiting,
non-asphaltic, lead and chromate-free, universal
modified-alkyd primer with performance
complying with the requirements of FS TT-P-664,
two coats of synthetic enamel paint and paint
thinner. m2 82.10 650.00 53,365.00
-
3.2 Apply light weight concrete over roof slab with 2%
slope towards down pipe openings and make ready
for water proofing works (price includes chiseling
the surface ). m2 539.90 280.00 151,172.00
-
3.3 Spread and level 3cm thick cement sand screed(1:3)
on top of light weight concrete to receive water
proofing material. m2 539.90 120.00 64,788.00
-
3.4 HERTLAN (E.P.D.M.) water proofing roofing
system according to manufacturers instruction.(or
similar product approved by the Architect) m2 539.90 450.00 242,955.00
-
3.5 Ditto but copping with a development length of
500mm. m 122.00 93.00 11,346.00
-
3.6 Ditto but flashing with development length of
660mm. m 43.20 135.00 5,832.00
-
TOTAL CARRIED TO SUMMARY ....... 529,458.00

4. CARPENTRY & JOINERY

All timber shall be well seasoned and free from


harmful defects.

Supply and fix 40mm thick best quality internal


flush type wooden doors in hard wood frame both
sides covered with 4mm thick weira ply wood.
Price shall include safety locks, hinges, door stoper
and other necessary accessories and three coats of -
varnish paint. -
4.1 WD1 size 800x2100mm No 89.00 4,200.00 373,800.00
-
4.2 WD2 size 1200x2100mm No 2.00 6,300.00 12,600.00
-

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

TOTAL CARRIED TO SUMMARY ....... 386,400.00

5, ALUMINIUM AND METALWORK

5.1 ALUMINIUM WORK


All doors & windows are manufactured from
aluminum profile frames. All works should be cut
and assembled to sizes and shapes of the window
and door schedule upon submitting workshop
drawing by the contractor. Unit price includes 5mm
clear glass, anchored bolts 2mm thick aluminum
cover plates, cylindrical key, door stoppers and
other necessary accessories for completing the
work. All according to window schedule and as
specified.

WINDOW DOORS
5.1.1 AWD-1 size3200x2700mm No 1.00 21,600.00 21,600.00
-
5.1.2 AWD-2 size (1900x1800)+(900X2100)mm No 1.00 13,275.00 13,275.00
-
5.1.3 AWD-3 size (1200x1900)+(900X2100)mm No 1.00 10,425.00 10,425.00

5.1.4 AWD-4 size (1200x1800)+(900X2100)mm No 1.00 10,125.00 10,125.00

5.1.5 AWD-5 size1200X2700mm No 1.00 8,100.00 8,100.00


WINDOWS 0.00 -
5.1.5 AW-1 size2200X1750mm No 21.00 9,625.00 202,125.00
-
5.1.6 AW-2 size2600X1750mm No 2.00 11,375.00 22,750.00
-
5.1.8 AW-3 size2800X2800mm No 38.00 19,600.00 744,800.00
-
5.1.9 AW-4 size13500X1750mm No 2.00 5,907.00 11,814.00
-
5.1.10 AW-5 size1200X1850mm No 12.00 5,550.00 66,600.00
-
5.1.11 AW-6 size900X800mm No 28.00 1,800.00 50,400.00

5.1.12 AW-7 size3750X1600mm No 2.00 15,000.00 30,000.00


-
5.1.13 AW- 8size3750X1200mm No 2.00 11,250.00 22,500.00

5.1.14 AW- 9size2850X750mm No 2.00 5,344.00 10,688.00


-
5.1.15 Supply & fix in position Aluminum railing for stair
case in accordance with drawing & technical
specifications. Price shall include & all necessary
fixing accessories including but not limited to :
brackets, flanges, anchors, fasteners, grouting and
anchoring cement.
ml 30.00 750.00 22,500.00
-
5.2 METAL WORK

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

All doors & windows are manufactured from


38x1.5mm LTZ profile frames and 0.8mm thick
ribbed sheet . All works should be cut and
assembled to sizes and shapes of the window and
door schedule upon submitting workshop drawing
by the contractor and approved by the engineer.
Unit price shall includes 6mm thick glass for
louvers ,louver blade NACO louver holders, two
coats of antirust and three coats of synthetic enamel
paint ,approved quality cylindrical lock, door
stoppers and all the necessary accessories for
completing the work. All according to window
schedule and as specified.

-
5.2.1 MD-1 size700x2100mm No 16.00 1,470.00 23,520.00

TOTAL CARRIED TO SUMMARY ....... 1,271,222.00

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

6. FINISHING WORKS
Finishing work shall include all surface pre-
cleaning, Preparation and application of the finish,
polishing and cleaning at the end of finished work.

6.1 Apply three coats of plaster in cement mortar (1:3)


to external surfaces of wall, columns & beams. m² 1,700.60 150.00 255,090.00
-
6.2 Apply two coats of plaster in cement mortar (1:3)
and final gypsum coating to all internal wall
surface, columns & beams. m² 6,078.40 120.00 729,408.00
-
6.3 Ditto above but to RC ceiling, stair case soffit and
sides. m² 2,836.30 120.00 340,356.00
-
6.4 Apply two coats of plaster in cement mortar (1:3 to
receive ceramic wall tile. m² 347.30 120.00 41,676.00
6.5 Supply & fix 6mm thick good quality non slippery
ceramic flooring tiles on and including 44mm thick
cement sand screed (1:3)mix and joints pointed in
white cement mortar(1:3) mix. Architect to approve m2 759.80 560.00 425,488.00
6.6 sample.
Supply and fix 2mm thick good quality PVC
flooring on 48mm thick cement screed bedding
including adhesive glue. The price shall include m2 1,318.60 350.00 461,510.00
6.7 48mm cement
Supply and fixsand
goodscreed.
quality ceramic wall tiles
stuck to the wall as shown on the drawings and
pointed with white cement. m2 347.30 600.00 208,380.00
6.8 Supply and fix 10mm high PVC skirting stuck to
wall with proper adhesive.. ml 684.89 70.00 47,942.30
6.9 100mm high ceramic tile skirting stuck to wall with
cement mortar (1:3)mix. ml 504.14 95.00 47,893.30
6.10 Supply and fix polished granite for stair case
bedded on cement sand mortar mix and grouting
joints for stair case. -
a) Tread 30x340mm ml 145.00 750.00 108,750.00
b) Risers 20x140mm ml 145.00 650.00 94,250.00
6.11 Supply and fix 30 mm thick granite window sill,
price shall include cement and sand mortar ml 249.75 110.00 27,472.50
-
bedding.
6.12 Supply and fix 30 mm thick granite door
sill(Threshold) , price shall include cement and sand
mortar bedding. ml 95.60 100.00 9,560.00

TOTAL CARRIED TO SUMMARY ....... 2,797,776.10

113
CENTRAL COMMAND
SPECIFICATION AND
CENTRAL COMMAND HEADQUARTER OFFICE BUILDING
BILL OF QUANTITY
AT SHIRE

ITEM DESCRIPTION UNIT QTY U.PRICE TOTAL PRICE.

7 .PAINTING
7.1 Apply three coats of plastic emulsion paint to
internal plastered wall, beam and column surfaces. m2 6,078.40 26.00 158,038.40
-
7.2 Ditto but to RC ceiling, stair case soffit and sides.
m2 2,836.30 29.00 82,252.70
-
7.3 Apply approved type quartz paint to all external
plastered HCB & structure surfaces as located in the
drawing. Price shall one coat of prime. m2 #REF! 26.00 #REF!
-
TOTAL CARRIED TO SUMMARY ....... #REF!

113
BAR SCHEDULE
ITEM NO DESCRIPTION DIA LENGTH NO OF MEMBERS TOTAL NO BARS
METER BARS
Staircase and landing (ground floor)
0
14 4.17 21 1 350.28
14 3.02 21 1 253.68
14 1.695 21 1 142.38
14 1.88 21 1 157.92
14 1.78 21 1 149.52
riser 8 0.866 160 1 554.24
landing 8 2.95 21 1 247.8
landing 8 1.88 32 1 240.64
14 5.38 21 1 451.92
14 2.412 21 1 202.608
14 2.56 21 1 215.04
14 1.6 21 1 134.4
14 3.45 21 1 289.8
Staircase and landing (first to ninth floor) 0
14 7.04 21 9 5322.24
14 3.02 21 9 2283.12
14 1.855 21 9 1402.38
14 1.88 21 9 1421.28
14 1.695 21 9 1281.42
riser 8 0.866 160 9 4988.16
landing 8 2.95 21 9 2230.2
landing 8 1.88 32 9 2165.76
14 5.38 21 9 4067.28
14 2.412 21 9 1823.472
14 2.56 21 9 1935.36
14 1.6 21 9 1209.6
14 3.45 21 9 2608.2
anchored in to beams bars(+33.00) 6 0.45 60 1 27
0
TOTAL LENGTH (m)
UNIT WEIGHT (kg/m)
TOTAL WEIGHT (kg)
6 8 10 12 14 16 20 24 26 28 30 32 REMARK

350.28
253.68
142.38
157.92
149.52
554.24
247.8
240.64
451.92
202.61
215.04
134.4
289.8

5322.2
2283.1
1402.4
1421.3
1281.4
4988
2230.2
2166
4067.3
1823.5
1935.4
1209.6
2608.2
27

27 10427 0 0 25702 0 0 0 0 0 0 0