You are on page 1of 29

Non-Destructive Testing Services for

HRSGs Provided by TesTex

Shawn Gowatski
TesTex, Inc.
412-798-8990
s.gowatski@testex-ndt.com
INSPECTION OF FINNED
TUBES FROM THE OUTSIDE
SURFACE

INSPECTION OF TUBE TO
HEADER WELDS
INSPECTION OF HRSG TUBES USING THE LOW
FREQUENCY ELECTROMAGNETIC TECHNIQUE
LOW FREQUENCY ELECTROMAGNETIC TECHNIQUE
Smashed fins on a HRSG Tube
Removed fins on a HRSG Tube
SMASHED REMOVED
FINS FINS
LFET CAN DETECT PITTING

LFET CAN DETECT GENERAL


WALL LOSSES

SIZING OF DEFECTS POSSIBLE


THROUGH PROPER
CALIBRATION STANDARDS
INSPECTION OF TUBE TO HEADER WELDS
PP&L donated a HRSG Header to TesTex
Tube to Header Mock-ups for project
Tube to Header Mock-ups for project
Section of PP&L header for modeling system
Tube to Header Weld Inspection Tool
Tube to Header Weld Inspection Tool
Tube to Header Weld Inspection Tool
BALANCED FIELD ELECTROMAGNETIC
TECHNIQUE (BFET)
BFET PROBE
Hawkeye Probe Diagram

Cable to
Electronics Box
Angle Hawkeye Probe

Test Piece
Driver Coil
Weld Detecting Coil

Electromagnetic coils are placed in a balanced state. The driver coil is placed
in the “x” geometry and the detecting coil is placed in the “z” geometry. This
geometry produces an unbalanced state when a defect is encountered.
Typical BFET Waveform

Waveform showing flaw indications on a Calibration Plate.


FUTURE HRSG PROJECT
WHAT ARE YOUR HRSG
INSPECTION NEEDS?