TCEA Pitot Calculation Sheet V07

This document contains a TCEA pitot calculation sheet from a measurement done on May 15, 2018 at 2:40pm at the ONIGBOLO plant. Pitot tube measurements were taken at the inlet and outlet of Filter U1P11 to calculate gas flow properties including velocity, flow rate, and dust concentration. Key measurements and calculations include the average dynamic pressure, gas density with and without dust, velocity of 15.08 m/s at the inlet and 14.74 m/s at the outlet, and a dust concentration of 30.0 g/m3 or 0.03 kg/Nm3.

Uploaded by

Sanchaise
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views4 pages

TCEA Pitot Calculation Sheet V07

This document contains a TCEA pitot calculation sheet from a measurement done on May 15, 2018 at 2:40pm at the ONIGBOLO plant. Pitot tube measurements were taken at the inlet and outlet of Filter U1P11 to calculate gas flow properties including velocity, flow rate, and dust concentration. Key measurements and calculations include the average dynamic pressure, gas density with and without dust, velocity of 15.08 m/s at the inlet and 14.74 m/s at the outlet, and a dust concentration of 30.0 g/m3 or 0.03 kg/Nm3.

Uploaded by

Sanchaise
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

TCEA PITOT CALCULATION SHEET - V07 Use of the calculation sheet

plant : ONIGBOLO Date : 15-mai-18 Time : 14h40


workshop : Origin of the source : Entrée Filtre U1P11 Registre
Condition of the test : Measurement point : Entrée Filtre U1P11

DUCT minimum of measurement points 4 14 Aeraulic surface 0.17 m2


Circular : DIAMETER 0.46 m Dynamic Pressure mbar pos° pitot Avg. Dyn. Pressure 175.66 Pa
Tapping 0.00 m 1 1.57 0.008 m RHO w/o dust (wet) 1.137 kg/m3
2 1.98 0.026 m RHO with dust (wet) 1.167 kg/m3
Rectangular : WIDHT 3 1.94 0.046 m
Rectangular : HEIGHT 4 1.78 0.067 m Velocity 15.08 m/s
5 1.68 0.092 m Flow (wet) 2.51 m3/s
Temperature 30 °C 6 1.61 0.124 m Flow (wet) 2.20 Nm3/s
Static Pressure -0.23 mbar 7 0.168 m Flow (wet) 9,021 m3/h
8 0.292 m Flow (wet) 7,932 Nm3/h
Pitot Tube Ratio 0.869 9 0.336 m
10 0.368 m P°&T° correction 0.8793
Dust concentration 30.0 g/m3 11 0.393 m
Dust concentration 0.03 kg/Nm3 12 0.414 m
13 0.434 m
Calculation of gas flow at reference conditions
Dust flow (t/h) 0.271 14 0.452 m
15 % H2O ref 0.00
16 Flow (H2O ref) 7,932 Nm3/h
Barometric Pressure 98,900.0 Pa 17

Atmospheric Pressure Ratio or 18 % O2 ref 10.00


0.976 19 Flow (H2Oref @ %O2ref) 0,000 Nm3/h
Elevation "h" 70 m 20 Flow (H2Oref @ %O2ref) 0.00 Nm3/s
Atm. Pressure @ "h" 10,245.8 mmWG NB VAL : 6
Atm. Pressure @ "h" 100440.98 Pa VAL maxi : 1.98

75% Rule : correct dynamic pressure data distribution

GAS COMPOSITION dry humid


M : Gas Molecular Weight (Wet) M : Gas Molecular Weight (dry) % H2O 0.00 Gas Density (wet) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
28.963 g/mole 28.963 g/mole % CO dry 0.00 0.00 (wet)
1.137 kg/m3

Standard Atmospheric Composition 0.03% % CO2 dry 0.03 0.03


20.93% % O2 dry 20.93 20.93 Gas Density (H2O ref) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
0.93% %Ar dry 0.93 0.93 (H2O ref) 1.137 kg/m3

78.10% %N2 dry 78.11

[Link] Printed 06/16/2020


TCEA PITOT CALCULATION SHEET - V07 Use of the calculation sheet

plant : ONIGBOLO Date : 15-mai-18 Time : 14h30


workshop : Origin of the source : Sortie Filtre U1P11 Registre
Condition of the test : Measurement point : Sortie Filtre U1P11

DUCT minimum of measurement points 4 14 Aeraulic surface 0.28 m2


Circular : DIAMETER 0.60 m Dynamic Pressure mbar pos° pitot Avg. Dyn. Pressure 167.23 Pa
Tapping 0.00 m 1 1.56 0.011 m RHO w/o dust (wet) 1.132 kg/m3
2 1.88 0.034 m RHO with dust (wet) 1.162 kg/m3
Rectangular : WIDHT 3 1.71 0.059 m
Rectangular : HEIGHT 4 1.73 0.088 m Velocity 14.74 m/s
5 1.71 0.121 m Flow (wet) 4.17 m3/s
Temperature 30 °C 6 1.46 0.161 m Flow (wet) 3.65 Nm3/s
Static Pressure -4.12 mbar 7 0.220 m Flow (wet) 15,004 m3/h
8 0.380 m Flow (wet) 13,141 Nm3/h
Pitot Tube Ratio 0.869 9 0.439 m
10 0.479 m P°&T° correction 0.8758
Dust concentration 30.0 g/m3 11 0.512 m
Dust concentration 0.03 kg/Nm3 12 0.541 m
13 0.566 m
Calculation of gas flow at reference conditions
Dust flow (t/h) 0.450 14 0.589 m
15 % H2O ref 0.00
16 Flow (H2O ref) 13,141 Nm3/h
Barometric Pressure 98,900.0 Pa 17

Atmospheric Pressure Ratio or 18 % O2 ref 10.00


0.976 19 Flow (H2Oref @ %O2ref) 0,000 Nm3/h
Elevation "h" 70 m 20 Flow (H2Oref @ %O2ref) 0.00 Nm3/s
Atm. Pressure @ "h" 10,245.8 mmWG NB VAL : 6
Atm. Pressure @ "h" 100440.98 Pa VAL maxi : 1.88

75% Rule : correct dynamic pressure data distribution

GAS COMPOSITION dry humid


M : Gas Molecular Weight (Wet) M : Gas Molecular Weight (dry) % H2O 0.00 Gas Density (wet) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
28.963 g/mole 28.963 g/mole % CO dry 0.00 0.00 (wet)
1.132 kg/m3

Standard Atmospheric Composition 0.03% % CO2 dry 0.03 0.03


20.93% % O2 dry 20.93 20.93 Gas Density (H2O ref) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
0.93% %Ar dry 0.93 0.93 (H2O ref) 1.132 kg/m3

78.10% %N2 dry 78.11

[Link] Printed 06/16/2020


TCEA PITOT CALCULATION SHEET - V07 Use of the calculation sheet

plant : ONIGBOLO Date : 15-mai-18 Time : 15h00


workshop : Origin of the source : Entrée Filtre U1P21 Registre
Condition of the test : Measurement point : Entrée Filtre U1P21

DUCT minimum of measurement points 4 14 Aeraulic surface 0.28 m2


Circular : DIAMETER 0.60 m Dynamic Pressure mbar pos° pitot Avg. Dyn. Pressure 30.08 Pa
Tapping 0.00 m 1 0.19 0.011 m RHO w/o dust (wet) 1.126 kg/m3
2 0.21 0.034 m RHO with dust (wet) 1.156 kg/m3
Rectangular : WIDHT 3 0.27 0.059 m
Rectangular : HEIGHT 4 0.31 0.088 m Velocity 6.27 m/s
5 0.33 0.121 m Flow (wet) 1.77 m3/s
Temperature 30 °C 6 0.35 0.161 m Flow (wet) 1.54 Nm3/s
Static Pressure -10.03 mbar 7 0.34 0.220 m Flow (wet) 6,382 m3/h
8 0.32 0.380 m Flow (wet) 5,556 Nm3/h
Pitot Tube Ratio 0.869 9 0.33 0.439 m
10 0.39 0.479 m P°&T° correction 0.8706
Dust concentration 30.0 g/m3 11 0.512 m
Dust concentration 0.03 kg/Nm3 12 0.541 m
13 0.566 m
Calculation of gas flow at reference conditions
Dust flow (t/h) 0.191 14 0.589 m
15 % H2O ref 0.00
16 Flow (H2O ref) 5,556 Nm3/h
Barometric Pressure 98,900.0 Pa 17

Atmospheric Pressure Ratio or 18 % O2 ref 10.00


0.976 19 Flow (H2Oref @ %O2ref) 0,000 Nm3/h
Elevation "h" 70 m 20 Flow (H2Oref @ %O2ref) 0.00 Nm3/s
Atm. Pressure @ "h" 10,245.8 mmWG NB VAL : 10
Atm. Pressure @ "h" 100440.98 Pa VAL maxi : 0.39

75% Rule : correct dynamic pressure data distribution

GAS COMPOSITION dry humid


M : Gas Molecular Weight (Wet) M : Gas Molecular Weight (dry) % H2O 0.00 Gas Density (wet) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
28.963 g/mole 28.963 g/mole % CO dry 0.00 0.00 (wet)
1.126 kg/m3

Standard Atmospheric Composition 0.03% % CO2 dry 0.03 0.03


20.93% % O2 dry 20.93 20.93 Gas Density (H2O ref) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
0.93% %Ar dry 0.93 0.93 (H2O ref) 1.126 kg/m3

78.10% %N2 dry 78.11

[Link] Printed 06/16/2020


TCEA PITOT CALCULATION SHEET - V07 Use of the calculation sheet

plant : ONIGBOLO Date : 15-mai-18 Time : 14h49


workshop : Origin of the source : sortie du ventilateur Registre
Condition of the test : Measurement point : sortie du ventilateur

DUCT minimum of measurement points 0 14 Aeraulic surface 0.07 m2


Circular : DIAMETER 0.30 m Dynamic Pressure mbar pos° pitot Avg. Dyn. Pressure 101.49 Pa
Tapping 0.00 m 1 0.98 0.005 m RHO w/o dust (wet) 1.066 kg/m3
2 1.00 0.017 m RHO with dust (wet) 1.096 kg/m3
Rectangular : WIDHT 3 1.02 0.030 m
Rectangular : HEIGHT 4 1.04 0.044 m Velocity 18,4 m/s
5 1.02 0.060 m Flow (wet) #VALUE!
Temperature 40 °C 6 1.03 0.081 m Flow (wet) #VALUE!
Static Pressure -31.01 mbar 7 0.110 m Flow (wet) #VALUE!
8 0.190 m Flow (wet) #VALUE!
Pitot Tube Ratio 1.100 9 0.219 m
10 0.240 m P°&T° correction 0.8247
Dust concentration 30.0 g/m3 11 0.256 m
Dust concentration 0.04 kg/Nm3 12 0.270 m
13 0.283 m
Calculation of gas flow at reference conditions
Dust flow (t/h) #VALUE! 14 0.295 m
15 % H2O ref 0.00
16 Flow (H2O ref) #VALUE!
Barometric Pressure 98,900.0 Pa 17

Atmospheric Pressure Ratio or 18 % O2 ref 10.00


0.976 19 Flow (H2Oref @ %O2ref) #VALUE!
Elevation "h" 70 m 20 Flow (H2Oref @ %O2ref) #VALUE!
Atm. Pressure @ "h" 10,245.8 mmWG NB VAL : 6
Atm. Pressure @ "h" 100440.98 Pa VAL maxi : 1.04

75% Rule : correct dynamic pressure data distribution

GAS COMPOSITION dry humid


M : Gas Molecular Weight (Wet) M : Gas Molecular Weight (dry) % H2O 0.00 Gas Density (wet) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
28.963 g/mole 28.963 g/mole % CO dry 0.00 0.00 (wet)
1.066 kg/m3

Standard Atmospheric Composition 0.03% % CO2 dry 0.03 0.03


20.93% % O2 dry 20.93 20.93 Gas Density (H2O ref) 1.293 kg/Nm3
P°&T° RHO corr°. w/o dust
0.93% %Ar dry 0.93 0.93 (H2O ref) 1.066 kg/m3

78.10% %N2 dry 78.11

[Link] Printed 06/16/2020

You might also like