Client : YERP 3146 Document No. : VE-507247 Location : Saudi Arabia 3425 Job No : 24-05100-0001 Unit : 179 11861 Supplier : Tag No. : V93-S9-PZV-0212 (Benzene Surge Valve) B Valve Type : Nitrogen Loaded PRV (Surge Valve)
KBR | Supplier Model No. :
Code : ASME SECTION VIII P&ID : NA-F42516 Sheet 017 Rev.D B Nominal Size Inlet | Outlet : By vendor in | By vendor in Rating/Facing Inlet | Outlet : 150 / RF | 150 / RF Connection Type Inlet | Outlet RF RF Material Body | Bonnet : Carbon Steel | Carbon Steel Trim | Bellows : Manufacturer Standard | Spring | Pilot : | Resilient Seat Seal : None Ctr Cause of Over Pressure : Surge due to sudden closing of a valve Fluid | State : Benzene | Liquid Required Flowrate Vap | Liq : | 441,000 kg/h B Mol Wt | Sp Gr @ Flowing Temp : | 0.882 Visc @ Flowing Temp Vap | Liq | 0.5 cP Oper Pressure | Set Pressure : 4 barg | 16.5 barg B Oper Temp | Design Temp : 43 C | 71 C Flowing Temp Max | Min : 43 C | 43 C Back Press Constant | Total : 0. barg | 1.3 barg Over Pressure % : Barometric Pressure : 1.014 bara Compressibility Factor : Ratio of Specific Heats : Coef of Discharge Vap | Liq : | Back Press Cap. Corr. Vap | Liq N/A | 1 Rupture disk tag | Supht Correction (steam) : | N/A Combined Capacity Correction : N/A Calculated Area : Note 1 sqcm Selected Area | Letter Designation : sqcm | Lever | Test Gag : | Pilot supply Filter| BackFlow Preventer : | Manual Blowdown : Notes: 1. Surge Relief Valve to be sized by the vendor. CERTIFIED FINAL 2. Supplier to specify ASME rated capacity based on relieving fluid. Revision A B Date 30-Nov-10 15-Jun-11 By AK TS/LS Check NP AA/NP Approved DC DC