Fires grow incredibly fast. A small spark can turn into a large
fire in seconds, and into a blaze in minutes. And a blazing fire
gives off massive amounts of heat and smoke, making it very
dangerous, if not impossible, to approach it.
Which means that even with the right extinguisher, a fire fighter
cannot get close enough to the flames to cover them effectively
with the extinguishing agent. Or, if he does get closer, he risks
serious injury from burns.
1 . E N G I N E E R E D FROM I N SI D E OUT.
< Flame retardant properties diluted < No dilution by washing and wearing.
by washing and wearing < Doesn't generate toxic gases and fumes.
< Generates toxic gases when exposed to fire < Does not burn, melt or drip
2 . FOUR LAYERS BETWEEN YOU AND DANGER.
Ceasefire Fire Suits are made out of not one but four protective layers, to
Flame Protection
L AYE R 1 L AYE R 2
This is the most important layer, with the A moisture barrier membrane, to protect
greatest exposure to heat and flames. against the intrusion of water, chemicals and
The quality of this outer shell decides how viral agents, allow metabolic heat to escape
close the fire fighter can go to the fire. and reduce overall heat stress during strenuous
Ceasefire Fire Suits always use molecular- activities. In our case, this layer is made up of
engineered fire resistant fabrics like Nomex, fire retardant knitted fabric with a PU
L AYE R 4
A final, inner protective lining which is designed to provide optimum comfort to the fire fighter by reducing surface friction and improving overal
L AYE R 3
E UROP E AN QUAL I TY
Manufactured by
Dupont Certified -
Reflective Tapes Latest Design
"Nomex ® Quality
manufactured by and safety
Partner Program"
Manufactured by Dual Mirror 3M and precautions for
and Licenced PBI®
ISO 9001 Technology used in “3M Scotchlite®” serious fire
Garment producer.
certified company. Aluminized Suits. labelled fighting.
Manufactured in
accordance with
latest EN standards: EN 531 EN 469:2005 Level 2 EN 1486
EN470-1 EN 1149-3
Application for people working in Hazardous areas like Refineries, Oil & Gas, Chemical & Petrochemical
Plants, Electrical Utilities, Iron & Steel and other Industrial Application.
World’s lightest Aluminized Suits for fire fighting, at only 6 kg (Without SCBA, Boots and Carrying Case) and
9 kg (Without SCBA and Carrying Case)
In addition to these international quality standards, Ceasefire Fire Suits boast the following features:
1. High Heat Resistance (as per ISO 17493) 5. Residual Strength (tensile strength after exposure to
0
Can withstand a heat level of 180 C for 5 minutes flames) of 450N (as per ISO 6942)
without any burning or melting and less than
6. 25N Tear strength (as per ISO 4674-1:2003 and
5% shrinkage
ISO1397-2:2000)
2. Limited inflammability (as per ISO 15025)
7. The suits are marked with fluorescent,
3. Tensile strength of 450N (as per ISO 13934-1) reflective tapes at strategic places as per EN standards.
4. Seam tensile strength of 450N (as per ISO 1421:1998) 8. Lowest Burn Ratio in Mannequin Tests.
NO ME X , KEVLAR AND PBI GO LD:
THE HEAR T OF C E A S E F I R E FIRE S UI T S .
KEVLAR
Amide Links
Also developed by DuPont, Kevlar is the registered
Aromatic Rings
trademark for a Para-Aramid synthetic fiber.
)n
NH O
NH C
O C
Extremely tough but light, Kevlar has a very high
tensile strength-to-weight ratio. Because Kevlar is
stiff rather than flexible, it is best used in
A registered trademark for a flame resistant fiber,
combination with Nomex, in a mixture known as
Nomex is a polymer developed by world-leader
Nomex III.
Dupont. Its manufacturing is a highly complex process,
in which the polymer Meta aramid isophtalamide is
poured through a sieve and emerges as a filament or
strand. This is then converted into a yarn through
spinning, and the yarn is used to weave the fabric.
Industrial Suits
Flame Protection
GARMENTLAYERS
Outer shell NOMEX III
Moisture Barrier FR knitted fabric with
PU membrane
Heat Barrier Aramid felt
Inner lining Aramid / Viscose FR
Sewing thread 100% NOMEX
ECOSTAR J ACKET
ECOSTAR T RO U SE R
Anti-wicking strips at
the leg hems 3M Scotchlite 8987 Leg hems at least 26 cm 5 cm width yellow fluorescent
and reflective tapes
Elastic belts on both the right 25 cm Front opening with Elastic and adjustable braces
and left sides of the waist a FR Velcro and single stud
ECOSTAR HELMET
The Ecostar Helmet is designed to protect the head from injury during drills, rescue-fire fighting missions,
or any other actions performed by fire-fighters.
TE S T I N G P A R A M E T E R S
0
Combustibility test at flames of temperature 950 C Test on resistance to penetration of elevated
0
(±50 C) after being heated at a temperature of 900 C
0
parameters; energy 24, 50 J, in temperature of
0 0
for 15 minutes -30 C and 50 C
Test on resistance to molten iron spill
Test on stroke-absorption directly after being
Test on resistance of the sight to chemicals, 2
irradiated by heat flux intensity of 14kW/m at
including hydrochloric acid, sodium hydroxide,
exposure time of 480s
Pxylene, n-heptane and butane
Test on resistance to heat flux intensity of
2
Test on resistance to hot solids
14kW/m at an exposure time of 480s 0
(steel ball of temperature of 900 C)
CHARACTERISTICS
0
Washable at 30 C
ECOSTAR BOOTS
Rugged build for protection and grip. Lightweight for complete manoeuvrability.
UPPER CONSTRUCTION:
< Flame retardant upper with heat insulation
Level 3 capabilities
MIDDLE CONSTRUCTION:
< One-piece stainless steel which exceeds
EN ISO 20345 sole penetration and flexing
test requirements
< Slip resistant vulcanized rubber sole conforms Chemical Resistant: Sole & Upper – Resistant
to EN 13287. towards mild acids and alkalis
< Excellent abrasion resistant for extra durability. Finishing: Hypalon lacquer coating for weather
protection.
< Tested to withstand 18kV of life current
(dry condition).
TY P E O F C O N S T R U C T I O N :
< Heel energy absorption design to minimize the VULCANIZEDRUBBERUPPERANDSOLE
impact to your heel.
European Standard CE Approved EN
< Centered to enter high temperature with 15090: 2006 (F2 IS H13 P T CI) EN
HRO performance.
20345: 2004 (SB P E CI SRA) CSA
< Multitasking performance with cold Z195-02 / ASTM F 2413 – 05
insulation protection. Lining Material: Extra comfort woven cotton canvas
PROSTAR
The ProStar is a further upgrade from the
Flame Protection
GARMENTLAYERS
Outer shell NOMEX - TOUGH
Moisture Barrier FR knitted fabric with
PU membrane
Heat Barrier Aramid felt
Inner lining Aramid / Viscose FR
Sewing thread 100% NOMEX
PROSTAR J ACKET
Radio Pocket
Pockets on front right and left with
closing by FR Velcro fasteners.
PROSTAR TROUSER
25 cm Front opening with a 5 cm width yellow silver yellow Elastic belts on both the right
FR Velcro and single stud reflective tapes with Aramid backing and left sides of the waist
3M Scotchlite 8987
Elastic and Anti wicking strips Leg hems at least
adjustable braces at the leg hems of 26 cm
the trousers
PROSTAR HELMET
The Prostar Helmet is designed to protect the head from injury during drills, rescue-fire fighting missions,
or any other actions performed by fire-fighters.
TE S T I N G P A R A M E T E R S
0
Combustibility test at flames of temperature 950 C Test on resistance to penetration of elevated
0
(±50 C) after being heated at a temperature of parameters; energy 24, 50 J, in temperature of
0 0 0
900 C for 15 minutes -30 C and 50 C
Test on resistance to molten iron spill Test on stroke-absorption directly after being
irradiated by heat flux intensity at 30°C; 50°C;
Test on resistance of the sight to chemicals, 100°C in water and after thermal radiation
including hydrochloric acid, sodium hydroxide,
Pxylene, n-heptane and butane Test on resistance to hot solids
0
(steel ball of temperature of 900 C)
Test on resistance to heat flux intensity of
2
14kW/m at an exposure time of 480s Test on retention system effectiveness
PROSTAR GLOVES
CHARACTERISTICS
PROSTAR BOOTS
Rugged build for protection and grip. Lightweight for complete manoeuvrability.
UPPER CONSTRUCTION:
< Flame retardant upper with heat insulation
Level 3 capabilities
MIDDLE CONSTROCTION
< One piece stainless steel which exceeds
EN ISO 20345 sole penetration and flexing
test requirements
< Slip resistant vulcanized rubber sole conforms Chemical Resistant: Sole & Upper – Resistant
to EN 13287. towards mild acids and alkalis
< Excellent abrasion resistant for extra durability. Finishing: Hypalon lacquer coating for weather
protection.
< Tested to withstand 18kV of life current
(dry condition).
TY P E O F C O N S T R U C T I O N :
< Heel energy absorption design to minimize the VULCANIZEDRUBBERUPPERANDSOLE
impact to your heel.
European Standard CE Approved EN
< Centered to enter high temperature with 15090: 2006 (F2 IS H13 P T CI) EN
HRO performance.
20345: 2004 (SB P E CI SRA) CSA
< Multitasking performance with cold Z195-02 / ASTM F 2413 – 05
insulation protection. Lining Material: Extra comfort woven cotton canvas
GOLDSTAR
The Goldstar is a high-end range of protective suits
Flame Protection
GARMENTLAYERS
Outer shell PBI Gold
Moisture Barrier FR nonwoven
with PU membrane
Heat Barrier 2 layers of FR nonwoven
Inner lining Aramid / Viscose FR
Sewing thread 100% ARAMID
GOLDSTAR J ACKET
Radio Pocket
Pockets on front right and left with
closing by FR Velcro fasteners.
GOLDSTAR TROUSER
25 cm Front opening Leg hems at least Elastic belts on both Anti wicking strips
with a FR Velcro 26 cm the right and left at the leg hems of
and single stud sides of the waist the trousers
Flame Protection
Outer Shell
Moisture Barrier
Heat Barrier
Elastic and Two rows of 3M scotchlite 9687, 5 Garment layers Inner Lining
The Goldstar Helmet is designed to protect the head from injury during drills, rescue-fire fighting missions,
or any other actions performed by fire-fighters.
TE S T I N G P A R A M E T E R S
0
Combustibility test at flames of temperature 950 C Test on resistance to penetration of elevated
0
(±50 C) after being heated at a temperature of parameters; energy 24, 50 J, in temperature of
0 0 0
900 C for 15 minutes -30 C and 50 C
Test on resistance to molten iron spill Test on stroke-absorption directly after being
irradiated by heat flux intensity at 30°C; 50°C;
Test on resistance of the sight to chemicals, 100°C in water and after thermal radiation
including hydrochloric acid, sodium hydroxide,
Pxylene, n-heptane and butane Test on resistance to hot solids
0
(steel ball of temperature of 900 C)
Test on resistance to heat flux intensity of
2
14kW/m at an exposure time of 480s Test on retention system effectiveness
GOLDSTAR GLOVES
CHARACTERISTICS
GOLDSTAR BOOTS
Rugged build for protection and grip. Lightweight for complete manoeuvrability.
UPPER CONSTRUCTION:
< Flame retardant upper with heat insulation
Level 3 capabilities
STEEL MIDSOLE
< One piece stainless steel which exceeds
EN ISO 20345 sole penetration and flexing
test requirements
< Slip resistant vulcanized rubber sole conforms Chemical Resistant: Sole & Upper – Resistant
to EN 13287. towards mild acids and alkalis
< Excellent abrasion resistant for extra durability. Finishing: Hypalon lacquer coating for weather
protection.
< Tested to withstand 18kV of life current
(dry condition).
TY P E O F C O N S T R U C T I O N :
< Heel energy absorption design to minimize the VULCANIZEDRUBBERUPPERANDSOLE
impact to your heel.
European Standard CE Approved EN
< Centered to enter high temperature with 15090: 2006 (F2 IS H13 P T CI) EN
HRO performance.
20345: 2004 (SB P E CI SRA) CSA
< Multitasking performance with cold Z195-02 / ASTM F 2413 – 05
insulation protection. Lining Material: Extra comfort woven cotton canvas
FIRE
ENTRY
SUITS
Fire entry suits are designed for the purpose of
for the breathing apparatus, pants, a hood, boots and
safely extinguishing fires that occur during
gloves, all constructed with multiple layers. The
hazardous situations.
garments that make up the fire entry suit are all
They comprise numerous layers and some of them stitched using superior quality DuPont 4-ply Kevlar
With a capacity to handle fires of up to 1093°C protection to the eyes, the fibre glass helmet
temperature they are primarily meant for entry inside has tempered glass and two gold plated lenses.
the fire affected area and for firefighting operations. The boots that accompany the suit are fitted with
Flame Protection
Garment layers
Outer Shell
Moisture Barrier
Heat Barrier
Inner Lining
GARMENTLAYERS
Ceasefire has introduced two kinds of Industrial Fire Suits for industrial worker protection:
manufacturing plants
METALSTAR
Everyday, welders and iron workers are exposed
damage on contact.
1) Test against flame exposure: Time taken for 3) Test against Molten Aluminium: Quantity of
nd
2 degree burns through flames exposure. molten aluminium poured & withstood by the
degree burns when exposed to a radiant heat of 4) Test against Molten Steel: Quantity of
that 8 minutes, thus meeting the C1 standard In the case of Ceasefire Metalstar it is
THREAT
10 ft.
SALIENTFEATURES
Provides permanent flame resistance
APPLICATIONS
Automotive Industry
Electrical Utilities
Engineering
Railways
Power Distribution
Ship Building
Think safety, think Ceasefire. Ceasefire's range of products
For years now, we have been India's No.1 fire safety brand.
1800-11-3473
1800-180-7233
0120-422-3473
BRANCH OFFICES
Delhi Noida Gurgaon Lucknow Kanpur Agra Jaipur Ludhiana Jalandhar Jammu Chandigarh Dehradun Haridwar
Ghaziabad Faridabad Panipat Bareilly Amritsar Meerut Patna Mumbai Nagpur Thane Belapur Pune Indore
Bhopal Ahmedabad Surat Baroda Bangalore Chennai Coimbatore Madurai Salem Hyderabad Vishakhapatanam Vijayawada
Cochin Mangalore Trivandrum Tirupati Hubli Tirupur Kolkata Bhubaneshwar Guwahati Jamshedpur Siliguri Raipur
Ceasefire Industries Pvt. Ltd. Plot No. - 4, Sector - 135, Noida - Greater Noida Expressway, Noida - 201301, Uttar Pradesh (India).