You are on page 1of 8

Company name:

Created by:
Phone:

Date: 16/12/2017
Position Qty. Description
1 NB 250-450/445 AS-F1-B-E-BAQE

Product No.: On request

Non-self-priming, single-stage, centrifugal volute pump designed according to ISO 5199 with
dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 10 with dimensions
according to EN 1092-2. The pump has an axial suction port, radial discharge port, horizontal shaft and
a back pull-out design enabling removal of the motor, motor stool, cover and impeller without disturbing
the pump housing or pipework.
The unbalanced rubber bellows seal is according to DIN EN 12756.
The pump is close-coupled to a fan-cooled asynchronous motor.

Liquid:
Pumped liquid: Cold water / cooling water
Liquid temperature range: 0 .. 120 °C
Liquid temperature during operation: 20 °C
Density: 999.9 kg/m³
Kinematic viscosity: 1 mm2/s

Technical:
Speed for pump data: 1490 rpm
Actual calculated flow: 3240 US GPM
Resulting head of the pump: 50 m
Actual impeller diameter: 445 mm
445 mm
Impeller nom: 450 mm
Impeller max: 445 mm
Primary shaft seal: BAQE
Secondary shaft seal: NONE
Curve tolerance: ISO9906:2012 3B
Rated head: 50 m
Rated flow: 3240 US GPM

Materials:
Pump housing: Cast iron
EN-GJL-250
ASTM A48-40 B
Impeller: Bronze
DIN W.-Nr. CuSn10
ASTM B584-C83600
Shaft: Stainless steel
1.4301
304
Rubber: EPDM
Wear ring mat.: High alloy brass(CuZn34Mn3AI2

Installation:
Maximum ambient temperature: 55 °C
Maximum operating pressure: 10 bar
Flange standard: EN 1092-2
Pump inlet: DN 300

Printed from Grundfos Product Centre [2017.08.028] 1/8


Company name:
Created by:
Phone:

Date: 16/12/2017
Position Qty. Description
Pump outlet: DN 250
Pressure rating: PN 10

Electrical data:
Motor type: SIEMENS
IE Efficiency class: IE3
Rated power - P2: 160 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y V
Rated current: 285-265/166-154 A
Starting current: 730-730 %
Cos phi - power factor: 0,9
Rated speed: 1490 rpm
Efficiency: IE3 95,8%
Motor efficiency at full load: 95.8-95.8 %
Motor efficiency at 3/4 load: 96.1-96.1 %
Motor efficiency at 1/2 load: 96.1-96.1 %
Number of poles: 4
Enclosure class (IEC 34-5): 55 Dust/Jetting
Insulation class (IEC 85): F
Lubricant type: Grease

Others:
Minimum efficiency index, MEI ≥: 0.70
ErP status: EuP Standalone/Prod.
Net weight: 1610 kg
Gross weight: 1720 kg
Shipping volume: 2.55 m³

Printed from Grundfos Product Centre [2017.08.028] 2/8


Company name:
Created by:
Phone:

Date: 16/12/2017

NB 250-450/445 50 Hz
H NB 250-450/445, 3*400 V, 50Hz eta
[m] [%]
Q = 3240 US GPM
H = 50 m
n = 89 % (44.5Hz)
75 Pumped liquid = Cold water / cooling water
Liquid temperature during operation = 20 °C
Density = 999.9 kg/m³
70
100 %
65

60

55 89 %

50

45

40

35

30

25 100

20 80

15 60

10 40

5 20
Eta pump = 86.7 %
Eta pump+motor+freq.converter = 80.7 %
0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 Q [US GPM]
P NPSH
[kW] [m]

200 20

P1
150 15
P2

100 10

50 5

P1 = 124.3 kW
P2 = 115.7 kW
NPSH = 4.84 m
0 0

Printed from Grundfos Product Centre [2017.08.028] 3/8


Company name:
Created by:
Phone:

Date: 16/12/2017
H NB 250-450/445, 3*400 V, 50Hz eta
Description Value [m] [%]
Q = 3240 US GPM
General information: 75 H = 50 m
Product name: NB 250-450/445 n = 89 % (44.5Hz)
70 Pumped
AS-F1-B-E-BAQE 100 liquid
% = Cold water / cooling water
Liquid temperature during operation = 20 °C
65
Product No: On request Density = 999.9 kg/m³
60
EAN number: On request
55 89 %
Technical: 50
Speed for pump data: 1490 rpm 45
Actual calculated flow: 3240 US GPM 40
Resulting head of the pump: 50 m
35
Actual impeller diameter: 445 mm
30
445 mm
25 100
Impeller nom: 450 mm
20 80
Impeller max: 445 mm
Primary shaft seal: BAQE 15 60

Secondary shaft seal: NONE 10 40

Shaft diameter: 60 mm 5 Eta pump = 86.7 % 20


Eta pump+motor+freq.converter = 80.7 %
Curve tolerance: ISO9906:2012 3B 0 0
0 1,000 2,000 3,000 4,000 Q [US GPM]
Pump version: AS
P NPSH
Rated head: 50 m [kW] [m]
Rated flow: 3240 US GPM 200 20

P1
Materials: 150 15
Pump housing: Cast iron P2

EN-GJL-250 100 10
ASTM A48-40 B
Impeller: Bronze 50 P1 = 124.3 kW 5
DIN W.-Nr. CuSn10 P2 = 115.7 kW
NPSH = 4.84 m
ASTM B584-C83600 12 x 23

12 x 23
216
299

150
508

625
563
374

20
125
28
200
0 0
250 180
165
1077
568

Shaft: Stainless steel


568 1077 180
1.4301 165 250

304
12 x 23
515

Material code: B
500
300

Rubber: EPDM
315

450
450

Code for rubber: E


200 28 20 125
Wear ring mat.: High alloy 625

brass(CuZn34Mn3AI2 374 563

150

508
Installation:
660

Maximum ambient temperature: 55 °C


500

508
374

12 x 23
Maximum operating pressure: 10 bar
Flange standard: EN 1092-2 299
216

Connect code: F1
Pump inlet: DN 300
Pump outlet: DN 250
Pressure rating: PN 10
Wear ring(s): neckring(s)
+T +T +T

Liquid:
Pumped liquid: Cold water / cooling water
Liquid temperature range: 0 .. 120 °C
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

Liquid temperature during operation: 20 °C TO AMPLIFIER


RELAY
L1 L2 L3

Density: 999.9 kg/m³


THERMISTORS PTC ACCORDING TO DIN 44082

Kinematic viscosity: 1 mm2/s


+T +T +T

Electrical data:
Motor type: SIEMENS
IE Efficiency class: IE3 TO AMPLIFIER
RELAY

Rated power - P2: 160 kW L1 L2 L3

Printed from Grundfos Product Centre [2017.08.028] 4/8


Company name:
Created by:
Phone:

Date: 16/12/2017
Description Value
Mains frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y V
Rated current: 285-265/166-154 A
Starting current: 730-730 %
Cos phi - power factor: 0,9
Rated speed: 1490 rpm
Efficiency: IE3 95,8%
Motor efficiency at full load: 95.8-95.8 %
Motor efficiency at 3/4 load: 96.1-96.1 %
Motor efficiency at 1/2 load: 96.1-96.1 %
Number of poles: 4
Enclosure class (IEC 34-5): 55 Dust/Jetting
Insulation class (IEC 85): F
Motor protec: PTC
Motor No: 83V15448
Mount. design. acc. IEC 34-7: IM B35
Lubricant type: Grease

Others:
Minimum efficiency index, MEI ≥: 0.70
ErP status: EuP Standalone/Prod.
Net weight: 1610 kg
Gross weight: 1720 kg
Shipping volume: 2.55 m³

Printed from Grundfos Product Centre [2017.08.028] 5/8


Company name:
Created by:
Phone:

Date: 16/12/2017

NB 250-450/445 50 Hz

508

500 450 508

216
250

563
125
625

150
20

374
12 x 23

500

450

515 315
374
180

28
1077

299

660
568

200
165

300
12 x 23

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos Product Centre [2017.08.028] 6/8


Company name:
Created by:
Phone:

Date: 16/12/2017

NB 250-450/445 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082

+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

Note! All units are in [mm] unless others are stated.

Printed from Grundfos Product Centre [2017.08.028] 7/8


Company name:
Created by:
Phone:

Date: 16/12/2017

NB 250-450/445 50 Hz
Input Sizing result
General Type NB 250-450/445
Application Air-conditioning Quantity 1
Application area Commercial Motor 160 kW
buildings Flow 3240 US GPM
Installation type Primary system only Head 50.01 m
Power P1 124.3 kW
Installation One chiller Power P2 required in the duty 115.7 kW
Flow (Q) 3240 US GPM point
Head (H) 50 m Eta pump 86.7 %
Prefer fast delivery No Eta motor 96.0 %
Your requirements Eta pump+motor 80.7 % =Eta pump * Eta
Pumped liquid Cold water / cooling motor
water Eta total 80.7 % =Eta relative to
Min. liquid temperature 6 °C the duty point
Max. liquid temperature 40 °C Energy consumption 253770 kWh/Year
Max. operation pressure 10 bar CO2 emission 236000 kg/Year
Allowed flow undersize 10 % Price On request
Min. inlet pressure 1.5 bar Price + energy costs On request /15Years
Life cycle cost /15Years
Control mode
Control mode Constant flow Controller is not included and must be appended to meet the
Enclosure class IP20 required input.

Edit load profile


H NB 250-450/445, 3*400 V, 50Hz eta
Yearly operation time 100 days [m] [%]
Q = 3240 US GPM
Load profile Standard profile H = 50 m
75
n = 89 % (44.5Hz)
Configuration 70 Pumped liquid = Cold water / cooling water
100 % Liquid temperature during operation = 20 °C
Select type of hydraulic Parallel 65 Density = 999.9 kg/m³
Total number of pumps 1
60
Operational conditions 55 89 %
Frequency 50 Hz
50
Phase 1 or 3
45
Min. power limit for SD start 5.5 kW
Voltage 1 x 230 or 3 x 400 V 40

35
Ambient temperature 20 °C 30

Hit list settings 25 100

Energy price 4.94 INR/kWh 20 80


Increase of energy price 6% 15 60
Calculation period 15 years
10 40

5 Eta pump = 86.7 % 20


Load Profile Eta pump+motor+freq.converter = 80.7 %
0 0
1 2 3 0 1,000 2,000 3,000 4,000 Q [US GPM]
Flow 100 100 100 % P NPSH
[kW] [m]
Head 100 85 70 %
P1 124.3 105.5 87.46 kW
Eta total 80.7 80.8 80.2 % 200 20
Time 800 800 800 h/a P1
Energy consumption 99417 84388 69967 kWh/Year P2
Quantity 1 1 1
100 10

P1 = 124.3 kW
P2 = 115.7 kW
NPSH = 4.84 m
0 0

Printed from Grundfos Product Centre [2017.08.028] 8/8

You might also like