SPECIFICATION FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS (ACI 1 1 7M-1 0) AND COMM ENTARY 31

SECT ION 4-CA ST-IN-PLA CE CONCRETE FOR BUILDINGS

SPECIFICATION COMMENTARY

4.1-Deviation from plumb R4.1-Deviation from plumb

4.1 .1 For heights less than or equal to 25.4 m R4.1.1 The tolerance for plumb varies with the height above
the top of foundation or the lowest support level of the
For lines, surfaces, corners, and arrises: the lesser of structure. B etween the top of foundation and a height of
0.3% times the height above the top of foundations or 25.4 m, the tolerance is 0.3% of the height until a maximum
lowest s u pport l evel as shown on P roject Drawings dimension of 25 mm is reached. Refer to Fig. R4. 1 . l (a)
o r ±25 m m This section shall not be used to evaluate and (b). The tolerance for the outside corner of exposed
local departure from a specified plane or form irregu lari­ corner columns and for contraction joint grooves in exposed
ties. Refer to Section 4 . 8 . 2 and 4.8.3, respectively. concrete is more stringent.

For the outside corner of an exposed corner column


and grooves in exposed concrete: the lesser of 0.2%
Tolerance
times the height above the top of foundations or lowest
support level as shown on Project Drawings or ±1 3 mm
This section shall not be used to evaluate local depar­
ture from a specified plane or form irregularities. Refer
to Section 4.8.2 and 4.8.3, respectively.

Height above foundation

! 11
or lowest support level

II
'
.
+
_ _ Top of foundation or
- · - · · -
lowest support level

(a)

PLAN
VIEW

Tolerance

(b)

Fig. R4. 1. 1-Deviationfrom plumb.