You are on page 1of 32

see more at SORInc.

com

Request Quote

Pressure and Vacuum Switches for Process Applications

SOR® pressure switches


are rugged, field-mounted instruments. The
pressure sensing element of the SOR pressure
switch is a force-balance, piston-actuated
assembly. The sensing element is sealed by a
flexible diaphragm and a static o-ring. A wide
selection of wetted parts materials for media
compatibility and containment are available. A
metal diaphragm may be welded to the
pressure port for certain applications, thereby
eliminating the o-ring.
B3
Application Information
The SOR pressure switches in this catalog are
suitable for a variety of process applications.
Basic models with standard wetted parts are
normally suitable for air, oil, water and non-
corrosive processes. See the Quick Selection
Guide on pages 4 and 5. Specific application
requirements can normally be met by selecting
optional components, such as switching
elements, diaphragm systems and pressure
ports. See How to Order on page 3. Certain
applications may require customized specials.
Consult the SOR representative in your area or
the factory. NN
This catalog describes switches that are:
• General Purpose
• Weatherproof
• Conventional Explosion Proof

Other specific types of switches available


through your SOR representative are:
• Hermetically Sealed (for hazardous locations)
• Pivot Seal (for high shock pressures
and cycle rates)
• Differential Pressure
• Temperature (remote and direct mount)
• Electronic and Mechanical Level
• Electronic Pressure LC

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 1/32
Pressure and Vacuum
Switches Features

Complete Product Line Agency Listings/Certification


Features and Benefits


Standard models and customized  Select models with ATEX, IECEx,
specials cover pressure ranges from CSA, FM, GOST R, INMETRO,
30 inches Hg VAC to 4000 psi. Rostechnadzor (RTN), TIIS, UL
 Meets most code and customer
Robust Construction requirements.
 Rugged, high-cycle rate tolerance, long
life, not critical to vibration, high overrange Safety Certified to IEC 61508 (SIL)
and proof pressures, excellent corrosion  SOR products are certified to IEC

resistance to hostile environments. 61508 for non-redundant use in SIL1



Enclosure ratings: NEMA 1, 4, 4X, 7, and SIL2 Safety Instrumented Systems
or 9 available. for most models. For more details or

Ingress protection rating up to IP66. values applicable to a specific product,
see the Safety Integrity Level Quick
Instrument Quality Guide (Form 1528).

High resolution of set points, high
repeatability, narrow dead band, Shock/Vibration
negligible temperature effect.  Select models tested to MIL-S-901D
(Navy) shock test.
Wetted Parts  Select models tested to MIL-S-167

Wide selection materials, process vibration test.
connection configurations and sizes.
Optional “fire-safe” pressure sensor. Built-In Quality
 Rigid quality standards maintained from
Snap-Action Electrical Switching raw material to finished product.

Wide selection UL Listed and CSA
Certified switching elements for AC Delivery
and DC service. Optional “hermetically  Routine shipments 7 to 10 working
sealed” capsule for hazardous and hostile days. Emergency shipments via same
environments. day air.
Field Adjustable
Service

Self-locking adjustment, no special tools
required. No-charge factory calibration.
 Factory sales engineers and area
SOR representatives provide
effective and prompt worldwide
Cost Effective service.
 Simple and fast installation without
special tools, long service life, no required Warranty
periodic service or spare parts.  3 years from date of manufacture.

2/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches How to Order

Model Number System

6NN-K5-M4-C2A-YY
Piston Housing Switching Spring Diaphragm & O-Ring Pressure Port Accessories
Element

Quick Selection Guide


Basic SOR pressure switches with standard wetted parts are normally suitable for air, oil, water and
non-corrosive processes. The Quick Selection Guide on pages 4 and 5 shows these basic SOR
pressure and vacuum switches. Corrosive service and particular customer requirements may require
optional components. Refer to How to Order section below to build a customized model number or
the dedicated page to locate optional components, such as switching elements, diaphragm systems,
pressure ports and accessories. Each position in the model number, except Accessories, must have
a designator.

Design and specifications are subject to change without notice. For latest revision, see sorinc.com.

Applications
SOR pressure switches in this catalog are suitable for a wide variety of continuous pressure
applications. Specific application requirements can normally be met by selecting optional
components, such as, switching elements, diaphragm systems and pressure ports. Certain
applications may require customized specials. Consult the SOR representative in your area or
the factory.

How to Order
Information and data in this catalog are formatted to provide a convenient guide to assist
instrument engineers, plant engineers and end users in selecting pressure switches for their
unique applications.

Steps 1 through 5 are required. Step 6 is optional. Orders must have complete Model Numbers,
i.e., each component must have a designator.

Step 1: Select Piston-Spring adjustable range/set point from Specifications


(pages 7 & 8). Piston-Spring combination determines adjustable range.

Step 2: Select Housing for type of pressure switch and service (page 9).

Step 3: Select electrical Switching Element for electrical service (pages 10 & 11).

Step 4: Select Diaphragm and O-Ring for process compatibility and containment
(pages 12 & 13).

Step 5: Select Pressure Port for process compatibility and connection (page 14).

Step 6: Select Accessories required for service (page 16).

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 3/32
Pressure and Vacuum
Switches Quick Selection Guide - Pressure

Basic SOR pressure switches with standard wetted parts are normally suitable for air, oil, water
and non-corrosive processes. Corrosive service and particular customer requirements may require
optional components. Refer to How to Order on page 3 to locate optional components, such as,
housing, switching elements, diaphragm systems, pressure ports and accessories. Each position in
the model number, except Accessories, must have a designator.

Adjustable Typical
Weatherproof Range Dead Band Explosion Proof
Model Number (increasing pressure) psi Model Number
psi (in. wc.) (in. wc.)
12NN - N66 - N4 - B1A (0.6 to 2.5) (0.4) 12L - N66 - N4 - B1A
12NN - K614 - N4 - B1A (2.5 to 45.0) (0.8) 12L - K614 - N4 - B1A
12NN - K2 - N4 - B1A 0.4 to 2.0 0.1 12L - K2 - N4 - B1A Explosion Proof
Weatherproof 12NN - K4 - N4 - B1A 0.5 to 6.0 0.1 12L - K4 - N4 - B1A
12NN - K5 - N4 - B1A 0.75 to 12 0.1 12L - K5 - N4 - B1A
12NN - K45 - N4 - B1A 1 to 16 0.15 12L - K45 - N4 - B1A
Piston 12 Overrange 200 (psi) Proof 400 (psi)
Adjustable
Typical
Weatherproof Model Range Explosion Proof
Dead Band
Number (increasing pressure) Model Number
psi
psi
4NN - K2 - N4 - B1A 2 to 8 0.2 4L - K2 - N4 - B1A
4NN - K4 - N4 - B1A 2 to 25 0.3 4L - K4 - N4 - B1A
4NN - K5 - N4 - B1A 3 to 50 0.4 4L - K5 - N4 - B1A
Weatherproof 4NN - K45 - N4 - B1A 4 to 75 0.5 4L - K45 - N4 - B1A Explosion Proof
Piston 4 Overrange 750 (psi) Proof 1000 (psi)

Standard Construction Notes


• Housing: NN - aluminum; L - cast iron 1. See balance of catalog for construction options.
• Switching Element: SPDT; N - 10 amps @ 2. Dead band values are expressed as typical
250 VAC; K - 15 amps @ 250 VAC expected at mid-range for a particular model
• Diaphragm & O-ring: N4 - primary (wetted) number. See Dead Band Considerations on page 8.
diaphragm, TCP; o-ring (wetted) Buna-N 3. Design and specifications subject to change
• Pressure Port: 1/4” NPT(F); B1A - aluminum; without notice. For latest revision, see sorinc.com.
F1A - carbon steel

4/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Quick Selection Guide - Pressure

Typical
Adjustable Range
Weatherproof Dead Explosion Proof
(increasing pressure)
Model Number Band Model Number
psi
psi
6NN - K2 - N4 - F1A 7 to 30 0.5 6L - K2 - N4 - F1A
6NN - K3- N4 - F1A 12 to 100 0.9 6L - K3 - N4 - F1A
6NN - K5- N4 - F1A 20 to 180 1.4 6L - K5 - N4 - F1A
Weatherproof 6NN - K45- N4 - F1A 25 to 275 1.9 6L - K45 - N4 - F1A Explosion Proof

5NN - K3- N4 - F1A 25 to 240 2.2 5L - K3 - N4 - F1A


5NN - K5- N4 - F1A 35 to 375 3.1 5L - K5 - N4 - F1A
5NN - K45- N4 - F1A 45 to 550 3.9 5L - K45 - N4 - F1A
9NN - K4- N4 - F1A 100 to 500 5.3 9L - K4 - N4 - F1A
9NN - K5- N4 - F1A 200 to 1000 9.2 9L - K5 - N4 - F1A
9NN - K45- N4 - F1A 200 to 1750 15 9L - K45 - N4 - F1A
1NN - K45- N4 - F1A 500 to 4000 98 1L - K45 - N4 - F1A
Piston 6, 5 Overrange 1500 (psi) Proof 2500 (psi)
9 2500 6000
1 5000 6000
Standard Construction Notes
• Housing: NN - aluminum; L - cast iron 1. See balance of catalog for construction options.
• Switching Element: SPDT; K - 15 amps @ 250 VAC 2. Dead band values are expressed as typical
• Diaphragm & O-ring: N4 - primary (wetted) expected at mid-range for a particular model
diaphragm, TCP; o-ring (wetted) Buna-N number. See Dead Band Considerations on page 8.
• Pressure Port: 1/4” NPT(F); B1A - aluminum; 3. Design and specifications subject to change
F1A - carbon steel without notice. For latest revision, see sorinc.com.

Quick Selection Guide - Vacuum


Typical
Adjustable Range Dead
Weatherproof Explosion Proof
Vacuum-O-Pressure Band
Model Number Model Number
in. Hg (in. wc) in. Hg
(in. wc)
52NN - K116 - M4 - B1A (20 - 0 - 20) (0.8) 52L - K116 - N4 - B1A

Weatherproof 52NN - K117 - M4 - B1A (40 - 0 - 40) (0.9) 52L - K117 - N4 - B1A
Explosion Proof
54NN - K117 - M4 - B1A 15 - 0 - 15 0.4 54L - K117 - N4 - B1A
54NN - K118 - M4 - B1A 30 - 0 0.6 54L - K118 - N4 - B1A
56NN - K216 - M2 - F1A 30 - 0 - 20 0.8 56L - K216 - M2 - F1A
56NN - K316 - M2 - F1A 30 - 0 - 160 1.1 56L - K316 - M2 - F1A
Piston 52 Overrange 200 (psi) Proof 400 (psi)
54 750 1000
56 1500 2500
Standard Construction Notes
• Housing: NN - aluminum; L - cast iron 1. See balance of catalog for construction options.
• Switching Element: SPDT; K - 15 amps @ 250 VAC 2. Dead band values are expressed as typical
• Diaphragm & o-ring: N4 - primary (wetted) expected at mid-range for a particular model
diaphragm, TCP; o-ring (wetted) Buna-N. Piston number. See Dead Band Considerations on page 8.
56 primary (wetted) diaphragm, 316SS. 3. Design and specifications subject to change
• Pressure Port: 1/4” NPT(F); B1A - aluminum; without notice. For latest revision, see sorinc.com.
F1A - carbon steel

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 5/32
Pressure and Vacuum
Switches Glossary of Terms

SOR recognizes that there is no industry convention with respect to terminology and definitions
pertinent to pressure switches. This glossary applies to SOR pressure switches.

Pressure Switch Proof Pressure


A bi-stable electromechanical device that The maximum input pressure that may be
actuates/deactuates one or more electrical continuously applied to the pressure switch
switching element(s) at a predetermined without causing leakage or catastrophic
discrete pressure/vacuum (set point) upon material failure. Permanent change of set
rising or falling pressure/vacuum. points may occur, or the device may be
rendered inoperative.
Adjustable Range
Repeatability
The span of pressure between upper and lower
The ability of a pressure switch to successively
limits within which the pressure switch may be
operate at a set point that is approached from
adjusted to actuate/deactuate. It is expressed
a starting point in the same direction and returns
for increasing pressure.
to the starting point over three consecutive
Set Point cycles to establish a pressure profile.
That discrete pressure at which the pressure Repeatability on SOR switches will be smaller
switch is adjusted to actuate/deactuate on than 1% of full scale per ISA/ANSI S51.1.
rising or falling pressure. It must fall within SPDT Switching Element
the adjustable range and be called out as
Single-Pole, Double Throw (SPDT) has three
increasing or decreasing pressure.
connections: C — Common, NO — Normally
Dead Band Open and NC — Normally Closed, which
The difference in pressure between the allows the switching element to be electrically
increasing set point and the decreasing set connected to the circuit in either NO or
point. It is expressed as typical, which is an NC state.
average with the increasing set point at DPDT Switching Element
mid-range for a pressure switch with the
DPDT is two synchronized SPDT switching
standard K switching element. It is normally
elements which actuate together at increasing
fixed (non-adjustable).
set point and deactuate together at decreasing
Fire-Safe set point. Discrete SPDT switching elements
The ability of a welded seal pressure sensor to allow two independent circuits to be switched;
contain the process at elevated temperatures i.e., one AC and one DC.
up to 1900°F at the rated overrange pressure, The synchronization linkage is factory set, and
unsupported by the body of the pressure switch. is not field adjustable. Synchronization is
Hermetically Sealed verified by connecting test lamps to the
switching elements and observing them go
A welded steel capsule with glass-to-metal,
“On” simultaneously at actuation and “Off”
factory-sealed electrical leads that isolates the
simultaneously at deactuation.
electrical switching element(s) from the
environment.
Overrange
The maximum input pressure that may be
continuously applied to the pressure switch
without causing permanent change of set
point, leakage or material failure.

6/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Step 1: Piston-Spring
6NN-K5-M4-C2A-YY

This table is a listing of piston-spring combinations and the corresponding adjustable ranges, dead bands,
overrange and proof pressures. Adjustable range is expressed for increasing pressure; the set point must be
within the adjustable range. Dead band is expressed as typical. See Dead Band Considerations on page 8.

Adjustable Range4 Typical Dead Band1 Overrange Proof


Piston-Spring
Designators psi bar psi bar
psi bar psi bar
(in. wc) [mbar] (in. wc) [mbar]
12 - 662 (0.6 to 2.5) [1.5 to 6.2] (0.4) [1]
12 - 6143 (2.5 to 45) [6.2 to 110] (0.8) [2]
12 - 2 0.4 to 2.0 [30 to 140] 0.1 [6.9]
200 14 400 28
12 - 4 0.5 to 6.0 [35 to 415] 0.1 [6.9]
12 - 5 0.75 to 12 [50 to 830] 0.1 [6.9]
12 - 45 1 to 16 [70 to 1100] 0.15 [10.3]
4-2 2 to 8 [140 to 550] 0.2 [13.8]
4-4 2 to 25 0.14 to 1.7 0.3 [20.7]
750 50 1000 70
4-5 3 to 50 0.2 to 3.5 0.4 [27.6]
4 - 45 4 to 75 0.3 to 5 0.5 [34.5]
6-2 7 to 30 0.5 to 2 0.5 [34.5]
6-3 12 to 100 0.8 to 7 0.9 [62.1]
6-5 20 to 180 1.4 to 12 1.4 [96.5]
6 - 45 25 to 275 1.7 to 19 1.9 0.13 1500 100 2500 170
5-3 25 to 240 1.7 to 16 2.2 0.15
5-5 35 to 375 2.4 to 26 3.1 0.21
5 - 45 45 to 550 3.1 to 38 3.9 0.27
9 - 46 100 to 500 7 to 35 5.3 0.37
9-5 6
200 to 1000 14 to 70 9.2 0.63 2500 170 6000 410
9 - 45 6
200 to 1750 14 to 120 15 1.03
1 - 456 500 to 4000 35 to 275 98 6.76 5000 340 6000 410

1. Dead band values are expressed as typical 5. Diaphragms may have an additional effect on
expected at mid-range with the standard K dead band. See page 13, Note 9.
switching element assembly installed. When 6. Diaphragm life may be limited by using T or H
optional switching elements are specified, switching elements with Numbers 1 and
corresponding dead band multipliers shown 9 pistons.
on pages 8 and 10 must be applied. 7. Metric bar (mbar) values are practical
2. The 12/66 piston/spring combination is equivalents of the reference English values; not
available with the N switching element only. necessarily exact mathematical conversions.
3. Adjustable range becomes 10 to 45 in. wc This data appears on the product nameplate
whenever switching elements other than K, KA, when metric engineering units are specified.
W, D or M are used. 8. A breather drain (Accessory KK, see page 16)
4. Special ranges may be possible. Consult the should be specified when low pressure
factory or the SOR representative in your area. adjustable ranges are used in environments
with significant ambient temperature changes.
9. Filled isolators attached to the pressure switch
will affect dead band.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 7/32
Pressure and Vacuum
Switches Step 1: Piston-Spring
52NN-K116-M4-C2A-YY

This table is a listing of piston-spring combinations and the corresponding adjustable ranges, dead bands,
overrange and proof pressures. SOR vacuum switches are compound; they will operate in either vacuum or
pressure modes. The adjustable range is expressed from maximum vacuum decreasing to zero gauge and
increasing to maximum pressure. Dead band is expressed as typical. See dead band considerations below.
The set point must be within the adjustable range. A vacuum switch is generally better suited than a pressure
switch for set points very near zero gauge.

Adjustable Range2 Typical Dead Band1


Overrange Proof
(Vacuum - 0 - Pressure) (Vacuum Mode)
Piston-Spring
in. Hg bar in. Hg
mbar psi bar psi bar
(in. wc) [mbar] (in. wc)
52 - 116 (20 - 0 - 20) [50 - 0 - 50] (0.8) 1.99
200 14 400 28
52 - 117 (40 - 0 - 40) [100 - 0 - 100] (0.9) 2.23
54 - 117 15 - 0 - 15 0.5 - 0 - 0.5 0.4 13.5
750 50 1000 70
54 - 118 30 - 0 1.0 - 0 0.6 20.3
56 - 2163 30 - 0 - 20 1.0 - 0 - 0.7 0.8 27.1
1500 100 2500 170
56 - 3163
30 - 0 - 160 1.0 - 0 - 5.4 1.1 37.3

Notes
1. Dead band values are expressed as typical 3. Number 56 piston is not available with a “T”
expected at mid-range with the standard K micro switch
switching element assembly installed. When 4. Diaphragms may have an additional effect
optional switching elements are specified, on dead band. See page 13, Note 9.
the corresponding dead band multipliers shown 5. Metric bar (mbar) values are practical
below must be applied. equivalents of the reference English values;
2. Special ranges may be possible. Consult the not necessarily exact mathematical conversions.
factory or the SOR representative in your area. This data appears on the product nameplate when
metric engineering units are specified.
Dead Band Considerations
1. Dead band values are expressed as typical expected at
mid-adjustable range using the standard K switching element. Switching Element Dead Band
When optional switching elements are specified, corresponding Designators Multiplier
dead band multipliers must be applied. K, KA, N, W 1.0
2. Dead bands are fixed (non-adjustable), except when T or H D, E, J, M, Y 1.5
switching elements are used.
A, B, EF, G, JF 3.0
3. Dead band can be adjustable by selecting T or H switching
element. (Diaphragm life may be limited when used with L, YY 3.5
Numbers 1 and 9 pistons.) AF, CA, EE 4.0
4. Dead band multipliers must be applied to the typical dead band
BD, C, JJ, S 5.0
value shown for piston spring combination in specifications,
pages 7 and 8, whenever optional switching elements other EG, JG 5.5
than K, KA or W are used. AA, BB, GG, KK 6.0
5. Dead band can be widened by selecting an optional switching
LL 6.5
element with a multiplier greater than 1.0.
Example: Model 6NN-G5-M4-C2A-YY AG 8.5
Typical Dead Band 1.4 psi T 2.5 to 6.5
G-Switching Element multiplier = 3 H 1.0 to 3.0
Corrected Typical Dead Band 1.4 x 3 = 4.2 psi
6. See item #9, page 7.

8/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Step 2: Housing
General Purpose NEMA 1 6NN-K5-M4-C2A-YY
Electrical: Exposed contacts
Electrical: 3/4” NPT(F) - Right Electrical: 3/4” NPT(F) - Left, Right Material: Aluminum
Material: Aluminum Material: Aluminum Open bracket with exposed switching
See Agency Listings pages 17 & 18. element-does not meet NEMA 1.
See Switching Element Groups See Switching Element Groups
PP 1, 2, 3 & 4 below. P3 1, 2, 3, & 4 below. H3 See Switching Element Groups 1 &
3 below.

Weatherproof NEMA 4, 4X, IP66

Electrical: 3/4” NPT(F) - Right Electrical: 3/4” NPT(F) - Right


Material: Aluminum Electrical: 3/4” NPT(F) - Left, Right
Material: Aluminum
See Agency Listings pages 17 Material: Aluminum
Cover: Heavy Duty with Viton gasket
& 18. See Agency Listings pages 17 & 18.
See Agency Listings pages 17 & 18.
See Switching Element Groups
NN See Switching Element Groups
N3 1, 2, 3 & 4 below. N4 See Switching Element Groups
1, 2, 3 & 4 below. 1, 2, 3 & 4 below.

Electrical - RN: 3/4” NPT(F) - Right Electrical - RT: 3/4” NPT(F) - Right
Electrical - RM: M20 x 1.5 - Right Electrical - RS: M20 x 1.5 - Right
Electrical: 3/4” NPT(F) - Right Six-place compression type terminal Six-place compression type
Material: Carbon Steel block terminal block
See Switching Element Material: Aluminum Material: 316SS
N6 Group 1 below. RN See Agency Listings pages 17 & 18. RT See Agency Listings pages 17 & 18.
RM See Switching Element Groups RS See Switching Element Groups
1, 2, 3 & 5 below. 1, 2, 3 & 5 below.
Electrical: 3/4” NPT(F) - Right
Manual reset only
Six-place compression type
terminal block
Material: Aluminum
See Agency Listings pages 17 & 18.
RB See Switching Element Group 6 below.

Hazardous Locations - Conventional Explosion Proof NEMA 4, 4X, 7, 9, IP66


UL Listed Class I, Group C & D; UL Listed Class I, Groups C & D; Separate electrical and set point
Class II, Group E, F, & G; Divisions Class II, Groups E, F & G; Divisions 1 adjustment compartments.
1 & 2 as an outlet box only & 2 as an outlet box only Weatherproof
Electrical: 3/4” NPT(F) - Right Electrical: 3/4” NPT(F) - Right Six-place, compression-type
Material: Cast Iron Six-place compression type terminal terminal block.
Weatherproof with Option CG block with Option LL See Agency Listings pages 17 & 18.
See Switching Element Groups 1, Material: Copper-free aluminum
*L 3 below. *LC Weatherproof
See Switching Element Groups 1, 2 &
3 below.

*B3 Electrical: 3/4” NPT(F) - Left, Right


Ul Listed Class I, Group C & D; UL Listed Class I, Groups C & D; Material: Aluminum
Class II, Group E, F, & G; Divisions Class II, Groups E, F & G; Divisions 1
1 & 2 as an outlet box only & 2 as an outlet box only Electrical: M20 x 1.5 - Left, Right
Electrical: 3/4” NPT(F) - Left, Electrical: 3/4” NPT(F)-Right, Left, Top *B4 Material: Aluminum
Right, Top Six-place, compression-type terminal
Material: Cast Iron block with Option LL
Material: Copper-free aluminum *B5 Electrical: M20 x 1.5 - Left, Right
Weatherproof with Option CG Material: Cast Iron
*S See Switching Element Groups 1, *SC Weatherproof
3, 6 below. See Switching Element Groups 1, 2, Electrical: 3/4” NPT(F) - Left, Right
3 & 6 below. *B6 Material: Cast Iron

Class I, Group A, B, C, & D; Class


Explosion Proof IIB - T4. Separate
II, Groups E, F, & G; Divisions 1 & 2
electrical and set point adjustment
as an outlet box only
compartments.
Electrical: 3/4” NPT(F) - Left, Right,
Electrical: PF 3/4”(F) - Right
Top
Six-place, ring-type terminal block. Switching Element Groups 1, 2, 3 & 5 below.
Material (Housing): Aluminum
Material: Aluminum
Material (Cover): Aluminum
*TA See Switching Element Groups 1, 2,
Weatherproof with Option CG. *J4 & 3 below.
See Switching Element Groups
1 & 3 below.
*Not recommended for direct mount where vibration is expected. Housing should be securely mounted to a flat surface (bulkhead or panel rack) or pipe stanchion.

Group 1 Group 2 Group 3 Group 4 Group 5 Group 6


Switching Element A, AA, B, BB,
Group/Housing BD*, C**, CA***, GG, KK, AF, AG, EF,
Compatibility T H D, M
E, EE, G, J, JJ, K, LL, YY EG, JF, JG
KA, L, N, S, W, Y
*BD only available with RN, RT housings.
**C micro switch is not available in L, S and TA housings.
***CA micro switch only available in PP, NN, N3 and N4 housings.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 9/32
Pressure and Vacuum
Switches Step 3: Switching Element
6NN-K5-M4-C2A-YY
Switching Electrical Electrical Dead Band
AC Rating DC Rating Resistive Designator
Element Contact Connection Multiplier
Service Type Type Volts Amps Volts Amps Volts Amps SPDT DPDT SPDT DPDT
Normal

Double Switching Element DPDT - (2) SPDT Synchronized actuation/deactuation at increasing/decreasing set points.
250 15 125 0.4* 30 5.0* 1.0 6.0 K KK
Service AC

All other Switching Elements _ 18” 18 AWG Color-Coded Wire Leads except when terminal blocks are specified.
Low Power 125 1 - - 28 1.0* 1.0 - KA -
Gold Contacts 125 1 - - 30 1.0 1.5 5.0 J JJ
Wide Dead Band AC 250 15 125 0.5 - - 3.0 6.0 G GG
AC or DC 250 11 125 0.5* 30 5.0 3.0 6.0 A AA
Wide Dead Band DC 250 15 125 0.5 30 10* 3.5 6.5 L LL
Narrow Dead
250 5 125 0.5* 30 5.0* 1.5 4.0 E EE
Band DC
Very Wide Dead
250 15 125 0.5 - - 5.0 - C -
Band DC
Very High- 1.5
Capacity DC Minimum
125 10 125 - - 5.0 - S -
Magnetic 10.0
Blow-Out Maximum
250 5 125 0.3 - - 3.0 6.0 B BB
Hi-Ambient
Temperature 250 5 125 0.5* - - 1.5 3.5 Y YY
K, KA, G, L, C, N, S, Y, W Switching Elements - Screw Terminals.

Rating - 400°F
250 5 125 0.3* - - 1.0 - W -
Low Pressure Service
250 10 - - - - 1.0 - N -
12-66 only
Wide Adjustable 2.5 to
250 15 125 0.4* - - - T -
Dead Band 6.5
Narrow Adjustable 1.0 to
250 15 - - - - - H -
Dead Band 3.0
T & H Switching Elements - Consult Factory.
Single Switching Element SPDT - (1) SPDT

Manual Reset -
(Automatic Actuation D -
Increasing Pressure)
250 15 125 0.5 - - 1.5 -
Manual Reset -
(Automatic Actuation M -
Decreasing Pressure)

Hermetically Sealed 250 11 125 0.5* 30 5.0 4.0 8.5 AF AG


Switching Element 250 5.0 125 0.5* 30 5.0* 3.0 5.5 EF EG
Hermetically Sealed
125 1.0 - - 30 1.0 3.0 5.5 JF JG
Gold Contacts
FM-Approved Service
250 22 125 0.5 - - 4.0 - CA -
Only
Explosion Proof EEx
250 7.0 250 0.25 30 7.0 5.0 - BD -
d IIC T6 (SW Only)

Cross reference compatibility chart on page 9 to ensure that switching element will fit in housing.
Review notes on page 11 for more details.

10/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Step 3: Switching Element
6NN-K5-M4-C2A-YY

Notes
1. Double switching elements have wire leads 5. Switching elements W, & Y have Elgiloy springs.
except when supplied in housings RB, RM, 6. Certain switching elements are capable of
RN, RS, RT, B3, B4, B5, B6 and J4. Terminal handling greater voltage and/or amperage.
blocks are standard in these housings. Consult the factory should your requirements
2. Dead band multipliers must be applied to the exceed catalog values. All switching elements
typical dead band figures given in the above except BD are UL Recognized and CSA
specification tables on pages 7 and 8. Certified. The DC current ratings marked with an
3. Switching element ambient temperature limits: asterisk (*) are not UL Listed but have been
verified by testing and/or experience.
-65 to 400oF (-54 to 204oC) B, Y, W 7. Ambient temperature is reduced to 200°F (93°C)
-65 to 250oF (-54 to 120oC) A, E, & J for J, JJ, A, AA, E, EE, B, BB, Y, YY, & W switching
-40 to 167oF (-40 to 75oC) AF, AG, EF, elements when CV accessory is selected.
EG, JF, JG
-13 to 158oF (-25 to 70oC) BD
Caution: The switching element assembly
-65 to 180oF (-54 to 80oC) All others
has been precisely positioned in the housing
4. The hermetically sealed switching element at the factory for optimum performance. Any
capsule is ATEX Approved, UL Listed, CSA inadvertent movement or replacement in the
Certified and TestSafe Approved as an explosion field will degrade performance, could render
proof snap switch according to the following the device inoperative, and can void the
table with conditions and exceptions specified warranty unless factory authorized procedures
in Note 3. are followed.
Hazardous Location
Agency Designator
Conditions
Class I, Groups A, B,
UL Listed C, & D AF, EF, AG,
CSA Certified Class II, Groups E, F EG, JF, JG
& G; Divisions 1 & 2
Ex s IIC T6 IP65
TestSafe AF, EF,
Class I, Zone I DIP
Approved AG, EG
T6 IP65
AF, EF, AG,
ATEX Approved II 2 G EEx m II
EG, JF, JG

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 11/32
Pressure and Vacuum
Switches Step 4: Diaphragm & O-Ring
6NN-K5-M4-C2A-YY
Notes
O-Ring Diaphragm
1. N4 diaphragm system is standard, but requires Designator
(Wetted) (Wetted Primary)
a designator in the model number. It is normally
suitable for air, oil, water and noncorrosive Viton A4
Monel
processes. M2 diaphragm system is standard Kalrez* A6
on Number 56 vacuum switches. (See notes Viton H4
Hastelloy-B
10 & 13.) Kalrez* H6
2. U7 designates a welded flush-type diaphragm. Viton J4
Available only in 1” NPT(M) 316SS on Hastelloy-C
Kalrez* J6
Numbers 5 & 6 pistons with K switching
element. See page 15. Viton L4
Carpenter-20
3. U8 designates the welded fire-safe diaphragm Kalrez* L6
system. 316SS is stocked. Not available on Viton GLT M1
Number 1 piston or vacuum switches. Buna-N M2
Example: U8-C2A is a 316SS fire-safe welded Viton M4
diaphragm system. See page 15.
Neoprene M5
4. U9 designates a welded diaphragm system. 316L SS
Not available on vacuum switches. Kalrez* M7
Example: U9-A1A is a Monel welded Aflas M8
diaphragm system. See page 15. M9
EPR
5. Other diaphragm and o-ring combinations may (See Note 11)

be available. Consult the factory or the SOR Viton


N1
(See Note 13)
representative in your area for more information.
6. Wetted parts have been selected as N3
Buna-N
TCP (See Note 7)
representing the most suitable commercially
Teflon-Coated N4
available material for use in the service intended. Polyimide
Buna-N Standard
However, they do not constitute a guarantee (See Notes 1 & 13)
against corrosion or permeation, since processes N5
vary from plant to plant and concentration of Kalrez*
(See Note 13)
harmful fluids, gases or solids vary from time to Kalrez* Kalrez N6
time in a given process. Empirical experience N7
by users should be the final guide. Alternate EPR TCP (See Note 13)
Teflon-Coated
materials are generally available. Polyimide N8
Aflas
(See Note 13)

P1
Buna-N Buna-N
(See Note 13)

Neoprene Neoprene R1
Viton S1
Viton
(Continued on page 13.) Viton GLT S2
Buna-N W2
Viton Tantalum W4
Neoprene (See Note 10) W5
Kalrez* W6
EPR EPR Y1
U7
None Welded
(See Note 2)

U8
None Fire-Safe Welded
(See Note 3)

U9
None Welded
(See Note 4)

*Kalrez or equivalent Perfluoroelastomer (FFKM) o-rings

12/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Step 4: Diaphragm & O-Ring
6NN-K5-M4-C2A-YY

7. N3 diaphragm system utilizes a durable 9. Dead bands are slightly higher when using
back-up diaphragm for high cycle-rate, high H, J, N3, N6, U or W series diaphragm
shock applications where Buna-N and TCP are options. Consult the factory.
compatible with the process. Consult factory if 10. Diaphragm systems N1, N3, N4, N5, N6, N7,
process temperatures are well below freezing. N8, P1, R1, S1, S2, W2, W4, W5, W6, Y1,
8. This table shows allowable minimum and U8, U9 are not available on vacuum switches
maximum temperatures for o-rings. Consult the with number 52, 54 or 56 pistons.
factory for temperatures down to –65°F on 11. M9 diaphragm system is suggested for steam
fire- safe and welded metal diaphragm applications up to 400°F.
systems. 12. If Kalrez, EPR or Viton is selected for high
temperature process media or ambient
O-Ring Material °F °C temperature requirements, the A, B, E, J, W or
Viton 32 to 400 0 to 204
Y switching elements are suggested with
reference to the table in Note 3, page 11.
Viton GLT -20 to 400 -29 to 204
13. Only diaphragm systems N1, N4, N5, N7, N8
Kalrez* 5 to 400 -15 to 204 and P1 are available on the 12-66 piston
Aflas 25 to 400 -4 to 204 spring combination.
Buna-N
-30 to 200 -34 to 93
Neoprene EPR
Fire-Safe/Welded
-30 to 400 -34 to 204
Diaphragm System
TCP Teflon-Coated
Polyimide -30 to 400 -34 to 204
Diaphragm
*Kalrez or equivalent Perfluoroelastomer (FFKM) o-rings

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 13/32
Pressure and Vacuum
Switches Step 5: Pressure Port
6NN-K5-M4-C2A-YY
6, 5,
12, 4 6, 5, 9 12, 4 6, 5, 9
Piston 9 4, 54 12, 52 12, 52
52, 54 1, 56 52, 54 1, 56
1, 56
2” NPT(F)
Process
1/4” NPT(F) 1/2” NPT(F) 3/4” NPT(M) 1” NPT(M) 1” NPT(F) 1/4” NPT(F)
Connection Size Flushing Port
Aluminum
Series 2000 B1A - B2A - - - - -
Wrought 356 or (Standard)
360 Casting
Carbon Steel
Ledloy Wrought - F1A - F2A F3A - - -
(Standard)
or WCB Casting
316SS/316LSS
Pressure Port Material

Wrought or C1A C2A C3A C4A* C5A C6A


CF-8M Casting
347 Stainless
Steel Wrought or
E1A E2A E3A
CF-8C
Casting
Carpenter 20
Stainless Steel
L1A L2A L3A
Wrought or
CF-7M Casting Consult factory availability of
pressure port material and
Brass (See Note 6) process connection size.
Half Hard Yellow
D1A D2A D3A
Wrought or Silicon
Brass Casting
Hastelloy-B H1A H2A H3A
Hastelloy-C J1A J2A J3A
Monel A1A A2A A3A
*C4A only available with Pistons 5 & 6 when U7 diaphragm is specified. See page 15.
Notes Examples:
1. Select designators for material and connection X2A = PVC pressure port with 1/2” NPT(F)
size. Large bold-face letters denote those items connection.
generally available from stock. Small light-face X1A = Titanium pressure port with 1/4” NPT(F)
letters denote items with limited stock and possible connection.
long delivery. Non-metal pressure ports generally reduce proof
2. 1/4” and 1/2” tapered BSP(F) pressure ports are pressure and may reduce overrange pressure. The
available. Consult factory. pressure port material may limit the process
3. Combinations are possible when a particular temperature. Delivery may be longer than normal.
connection size is not available for the range 5. Raised-face and flat-face flanges to match ASA 150
(piston spring) desired. For example, if 2” NPT(F) and ASA 300 lb. in commercially available materials
is desired for a Number 4 piston, the Number 12 can be supplied on Series 12 and 4 pistons by
pressure port can be supplied. The piston would adding an X suffix to the model numbers and
be designated as Number 124 and the overrange specifying “X - (size) inch (material) (raised- or flat-)
and proof pressures for Number 12 apply. Note: face flange to match ASA (rating) lb.”
124, 125 and 126 are the only available 6. Brass not available on Piston Numbers 9 and 1.
combinations. 7. 1/4” NPT(F) Flushing Port standard on C6A
4. Many other materials such as PVC, Kynar, etc., pressure ports.
are available. Denote materials not shown by
specifying an X followed by the required
connection size, and describe the material.
See next page for presentation of welded diaphragm and FM Approved fire-safe systems.

14/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum Welded Diaphragm
Switches & Fire-Safe Systems

Designator Description

U7
Welded Flush-Type Diaphragm System
A metal diaphragm is welded to the process face of the pressure port, thereby,
Process eliminating the o-ring. This arrangement may be indicated for viscous or slurry
Connection
process where cleanliness is required or where process build-up and clogging is
unacceptable.
The pressure port designator determines the material: Only 1” NPT(M) 316SS is
available.
Example: U7-C4A
U7 = 316SS welded flush-type diaphragm
Process C4A = 1” NPT(M) 316SS pressure port
Face Note: U7 is limited to Numbers 5 and 6 pistons and the K switching element. Not
available on vacuum switches.

U8
Piston Shaft
Fire-Safe Welded Diaphragm System
Factory Mutual System Approved - U.S Patent Number 4,438,305
Tested in flames at 1900oF for periods up to 30 minutes while pressurized to the
Spring
rated overrange pressure.
Stop A metal diaphragm, the cylinder disc and the pressure port are welded as a unit,
thereby, eliminating the o-ring. This arrangement may be indicated for extremely
Cylinder corrosive, hot, harsh or volatile process where o-rings are not suitable. See fire-
Disc safe definition on page 6.
316SS is stocked. Hastelloy B and C, and Monel are available, but may require a
longer lead time. The pressure port designator determines the material.
Diaphragm
Example: U8-C2A
U8 = Fire-safe welded diaphragm system
C2A = 1/2” NPT(F) 316SS pressure port
Note: 1/2” NPT(F) is stocked; 1/4” NPT(F) is not stocked and has a longer lead
Pressure Port time. Not available on Number 1 piston and vacuum switches.

U9 Welded Diaphragm System


Diaphragm A metal diaphragm is welded to the pressure port, thereby, eliminating the o-ring.
This arrangement may be indicated for extremely corrosive, hot or harsh process
where o-rings are not suitable.
316SS is stocked. Hastelloy B and C, and Monel are available, but may require a
longer lead time. The pressure port designator determines the material.
Example: U9 - A2A
U9 = Monel welded diaphragm
A2A = 1/2” NPT(F) Monel pressure port
Pressure
Port Note: Not available on vacuum switches.

C6A
Two-inch Pressure Port
The wide pressure port minimizes the possibility of clogging when the process media is sludgy or
viscous. See page 20 for dimensions. A 2” NPT(F) pressure port with a 1/4” NPT(F) flushing port
can be supplied with a welded diaphragm, or with a conventional diaphragm and o-ring combination.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 15/32
Pressure and Vacuum
Switches Step 6: Accessories
6NN-K5-M4-C2A-YY
Accessory/Option & Description Designator
Wetted parts are cleaned for oxygen service. BB
ATEX/IECEx approved pressure/vacuum switch. See Agency Listings on page 18 for details. CL
CSA Certified pressure/vacuum switch. Available with PP, NN, RB, RN, RT, B3 and B6. Housing has earth (ground) lug. See Agency
CS
Listings on page 17 & 18 for details.
Neoprene cover gasket (o-ring) to make L, S and TA explosion-proof housings weathertight. CG
Canadian Registration Number (CRN) - Process ratings may be affected. Consult the factory for details. CV
Cemented cover gasket on weathertight housings. GC
Sealed electrical lead adapter. Provides protection to housing interior, switching element and dry side of pressure sensing assembly
GG
from condensate in the electrical conduit and corrosive atmospheres. (Protrudes approximately 2” from housing.)
Universal terminal box. Stainless steel, 1/2” NPT(F). ATEX/IECEx Approved Ex db IIC T4, T5, T6 & Gb. HB**
Universal terminal box. Stainless steel, M20 x 1.5(F). ATEX/IECEx Approved Ex db IIC T4, T5, T6 & Gb. HBME**
Universal terminal box. Stainless steel, 1/2” NPT(F). FM Approved and CSA Certified. Explosion Proof Class I, Groups A, B, C, & D;
HT**
Class II, Groups E, F & G; Class III; Divisions 1 & 2 (NEMA 4X IP65)
Crouse Hinds ECD-15 for Hazardous Locations Class I, Groups C & D, Class II, Groups E, F & G; on S or SC housings only.
Breather Drain KK
Sintered metal plug in weathertight housing.
Terminal block. 6-place compression type standard in B and R series housings. Optional in LC and SC housings. 6-place screw type
LL
standard in J4 housing.
Multi-Listed pressure/vacuum switch. ATEX, IECEx, CSA & UL. Available with B3 & B6 housings. See Agency Listings on Pages 17 & 18 for details. ML
Vacuum protector plate. Retains diaphragm in pressure switch if subjected to vacuum greater than 10 in. Hg. If a pressure switch is
subjected to continuous, rapid changes of vacuum, other protection may be available (consult factory). Material matches or exceeds MM
pressure port material. N/A on Pistons 52, 54, or 56.
Compliance to NACE Certification MR0175/ISO 15156. NC*
INMETRO approved pressure/vacuum switch. See Agency Listings on page 18 for details. NM
Carbon steel body with stainless steel adjusting nut. PB
Pipe (stanchion) mounting kit for (1-1/2 to 2” pipe). PK
Tag, fiber. Attached with plastic wire to housing. Stamped with customer-specified tagging information. PP
Powder coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) PY
Tag, stainless steel. Attached with stainless steel wire to housing. Stamped with customer-specified tagging information. (2 lines, 18
RR
characters and spaces per line.)
Stainless steel body and adjusting nut for corrosive environments. SB
Stainless steel piston and cylinder disc for corrosion resistance. SP
Explosion proof weatherproof electrical junction box with screw terminals. Aluminum 3/4” NPT(F) top or right conduit connections as
required. UL Listed and CSA Certified Class I, Groups A, B, C & D; Class II, Groups E, F & G; Divisions 1 & 2. (Available on L, LC, S, TB**
SC and TA housing.) Includes cover o-ring for weatherproof applications.
Taiwan Safety Mark. Requires IECEx approval. See Agency Listings on page 18 for details. TS
Oversize stainless steel nameplate or separate stainless steel tag. Permanently attached to housing. Stamped with customer-specified
TT
tagging information.
Fungicidal varnish. Covers exterior and interior except working parts. VV
UL Listed pressure vacuum switch. Available with B3 and B6 housings. See Agency Listings on page 17 & 18 for details. WV
“X” is used as a suffix to the model number for special requirements not keyed elsewhere in the model number by an “X”. Each “X”
must be completely identified in the text of the order or inquiry. When more than one “X” is required, use “X” followed by the number of X
such items. For example, “X3” means three separate otherwise unidentifiable requirements.
Epoxy coating. Exterior only. Polyimide epoxy with 316SS pigment. (200 hours-salt spray) YY
Chained cover with captive screws to conform to former JIC specification. ZZ
Note: See pages 17 & 18 for Agency Approved, Certified or Listed Accessories Options.
* Consult the factory for materials other than 316/316L.
** Agency ratings for SOR product sold with junction boxes will be limited to either the rating of the instrument housing or junction box, whichever is lower.

16/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Test Certificates
Certificates C1 C2 C3 C4 C5 C6 C8 B1 B4 B5 B6 B7 A1 A2 A3 A4 A5 A6 A7 A8
Calibration ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
Hydrostatic
Pressure Test
¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿

Inspection Report ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
Compliance /
Conformance
¿ ¿ ¿ ¿ ¿ ¿ ¿

Dielectric Test ¿ ¿ ¿ ¿
Insulation Resistance ¿ ¿ ¿ ¿ ¿ ¿ ¿
Typical Material
of Wetted Parts
¿ ¿ ¿ ¿ ¿ ¿

Agency Listings
UL For Hazardous Locations Class I, Groups B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2
Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
WV or ML
A, AA, AF, AG, B, BB, Required
C, E, EE, EF, EG, G,
ALL B3, B6 GG, H, J, JF, JG, JJ, K, ALL ALL ALL All except CG,
KA, KK, L, LL, N, P, S, T, GC, GG, HB,
W, Y, YY HT, KK, LL, ME,
TB, TS, ZZ

CSA For Hazardous Locations Class I, Groups B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2
Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
CS or ML
A, AA, AF, AG, B, BB, Required
C, E, EE, EF, EG, G,
ALL B3, B6 GG, H, J, JF, JG, JJ, K, ALL ALL ALL All except CG,
KA, KK, L, LL, N, P, S, T, GC, GG, HB,
W, Y, YY HT, KK, LL, ME,
TB, TS, ZZ
General Purpose and Weathertight (CSA Enclosure Type 4)
Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
PP
(General A, AA, B, BB, C, E, EE, CS Required
Purpose) G, GG, GA, H, J, JJ, JL,
K, KK, KA, L, LL, N, S, T,
NN W, Y, YY
(Type 4)
A, AA, AF, AG, B, BB,
ALL ALL ALL ALL
C, E, EE, EF, EG, G,
RN, RT All except
GG, GA, J, JJ, JL, JF, JG,
(Type 4) GC, LL, TS
K, KK, KA, L, LL, N, S, T,
W, Y, YY
RB D, DA, M
(Type 4) (Manual Reset only)

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 17/32
Pressure and Vacuum
Switches Agency Listings

TIIS For Hazardous Locations Rating: Explosion Proof Class IIBT4


Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
A, AA, B, BB, C, E,
BB, MM, NN,
1, 4, 5, 6, EE, G, GG, GA, H,
PB, PC, PK,
9, 12, 52, J4 J, JJ, JL, K, KK, KL, L, ALL ALL ALL
PP, RR, SB,
54, 56 LL, N, S, T, W, WW,
TT, W, YY, X
Y, YY
FM Pressure Supervisory Switches for Fuel Gas/Fuel Oil, and Ventilating or Combustion Air
Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
PP M2, M4, M5, KK (PP
ALL
(NEMA 1) N1, N3, N4, Housing only)
1, 4, 5, 6, 2, 3, 4, 5, N5, N6, P1, ALL
CA BB, MM, GG,
9, 12 NN, N3, N4 45, 614 R1, S1 U9,
W2, W4, W5, PP, RR, SS,
(NEMA 4) Thread Type: A, B
W6, Y1 TT, VV, YY, ZZ

Airflow Interlocking Switches for Ventilating or Combustion Air


Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
66 (N
N (12 Piston only) PP, RR, SS
PF switch)
4, 12 P1 B1A, B2A (SS same as
(NEMA 1) C, EE, G, K, L, S, 2, 4, 5, TT)
T, W 45, 614
ATEX/IECEx Ex db IIC T5/T6 Gb
or INMETRO
Pressure Port
Switching Diaphragm
Piston Housing Spring Material & Accessories
Element & O-Ring
Connection Size
CL (for all
Hsgs) or ML
(for B3/B6
Hsgs) required
A, AA, AF, AG, B, BB, for ATEX/IECEx
C, E, EE, EF, EG, G,
B3, B4,
ALL GG, H, J, JF, JG, JJ, K, ALL ALL ALL NM required
B5, B6
KA, KK, L, LL, N, P, S, for INMETRO
T, W, Y, YY
All except CG,
GC, GG, HB,
HT, KK, LL,
ME, TB, ZZ
Ex ia IIC T6...T4 Gb
RN, RM, CL required for
ALL J, JJ, JF, JG ALL ALL ALL
RT, RS ATEX/IECEx
Rostechnadzor (RTN)
Certificate
Permit for instruments used and operated in hazardous industrial facilities in Russia. Standard on most
models. Certificate available on request.

18/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Manual Reset
Manual Reset Button

SOR Pressure Switches in this catalog may be specified with


manual reset electrical switching elements D or M. D actuates
automatically on increasing pressure. M actuates automatically
on decreasing pressure. Depress the button to manually reset.
Housings must be RB (weatherproof) or S (explosion proof)
because of the requirement of a hub for the manual reset
assembly. Refer to page 3 for How to Order instructions.
RB - Weatherproof S - Explosion Proof

Weights
Actual shipping weights may vary from the
Weight
Housing (kgs) charted values because of product material,
(lbs)
configuration and packaging requirements.
H3 1.5 0.75
NN, N3, N4, PF, PP, P3 2 1 Note
RB, RM, RN 2.5 1.25 PK Pipe Kit adds approximately 1.5 lbs.
N6 3 1.5 (0.7 kgs). TB Junction box adds
LC, SC 4 2
approximately 5 lbs (2.25 kgs).
L, S 5 2.5
TA 6 3
B3, B4, J4, RT, RS 8 4
B5, B6 10 5

Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.
Notes 1. Dimensions in this catalog are expressed as millimeters over inches (Linear = mm/in.).
2. Dimensions marked with an asterisk (*) on housing dimension drawings (pages 20 through 31)
vary with respect to process connection size. The chart below lists these dimension variances.
3. Electrical Connection Size: 3/4” NPT(F) standard. 1/2” NPT(F), 1/2” NPT(M), M20 x 1.5,
PG 13.5, PF 3/4” optional. Consult the factory for compatibility with selected housing or
agency listing.
Piston Number
Process Connection Size
12, 52 4, 54 6, 5, 9, 1, 56
1/4” NPT(F) Shown Shown Shown
Add 13.2
1/2” NPT(F) Shown Shown
0.52
Add 23.1
3/4” NPT(M) - -
0.91
Add 5.6
1” NPT(F) - -
0.22
Add 46.0
1” NPT(M) - -
1.81
Add 25.4
2” NPT(F) - -
1.00
Add 29.7 Add 29.7 Add 29.7
Length “A” 1/4” NPT(M)
1.17 1.17 1.17
Add 38.9 Add 38.9 Add 38.9
Length “A” 1/2” NPT(M)
1.52 1.52 1.52

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 19/32
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Drawing 0091354
Wide Pressure Port: C6A
See description on page 15.

SALES PAGE
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

HOLES FOR 5/16


MOUNTING HARDWARE.
SWITCH MOUNTING FURNISHED WITH
HOLES (TYP 4) U-BOLTS FOR MOUNTING
TO 1-1/2" TO 2" PIPE.

71.4 95.3
2.81 3.75

PARALLEL
PERPENDICULAR
MOUNTING
MOUNTING
SCALE 0.375
SCALE 0.375

SWITCH
71.4 31.0 11.9 MOUNTING
2.81 1.22 0.47 HOLES

PRESSURE 40.5 7.1


133.4 1.59 0.28
PORT SIDE
5.25

14685 W 105TH ST LENEXA, KS 66215 USA


913-888-2630
50.8 ISO-9001
SORINC.COM
2.00 DRAWN BY

J REHM
PRODUCT CERTIFICATION DRAWING CHECKED BY
ALL DIMENSIONS ARE 1/16 IN
M SMITH
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = S BOAL
IN
DATE

4/27/16
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
63.5 REF MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.

2.50 TITLE

DIM DWG
PIPE MOUNTING KIT
DRAWING NUMBER REV
EO NUMBER: 4935
0090300 4
PERPENDICULAR MOUNTING PARALLEL MOUNTING SCALE: 0.75 DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B
Model Name: 0090300.ASSEM//+

Drawing 0090300 Drawing 0091353


Pipe Mounting Kit: PK Junction Box with Terminal
Block: TB
20/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Weatherproof - NEMA 4, 4X, IP66


MODEL # SALES PAGE 1
SALES ORDER # LINE ITEM # PURCHASE ORDER #
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
108.1
108.1 4.25
4.25
52.4 **56.5
52.4 19.3 **56.5 18.7 2.06 2.22
2.06 0.76 2.22 0.73
69.9 28.6
69.9 28.6 2.75 1.13
PROCESS
2.75 1.13 LENGTH A
CONNECTION SIZE 33.3 26.1 PROCESS
33.3 26.1 1/4 NPTM 29.7 CONNECTION SIZE
1.31 1.03
1.31 1.03 SHOWN 1.17 1/4 NPTM
38.9 SHOWN
1/2 NPTM
1.53
1/2 NPTM
ELECTRICAL HOUSING GROUP ** DIMENSION DETAIL 1 NPTM
CONNECTION PROCESS CONNECTION HOUSING GROUP *
3/4 NPTF STD NN & N3 SHOWN SCALE 0.3
1/2 NPTF OPT
M20 X 1.5 F OPT 4.6 NN & N3
(BOTH SIDES ON N4 ADD
0.18 ELECTRICAL
N3 & P3 HSGS) 1.5 CONNECTION N4
PP & P3 SUBTRACT 3/4 NPTF STD
40.5 0.06
*149.5 1.59 1/2 NPTF OPT PP & P3
PROCESS
5.89 * LENGTH M20 X 1.5 F OPT
CONNECTION SIZE
(BOTH SIDES ON PROCESS
N3 & P3 HSGS) 40.5 CONNECTION SIZE
1/4 NPTF SHOWN 1.59
*150.9
6.4 5.94 1/4 NPTF
CLEARANCE SLOTS FOR 1/2 NPTF SHOWN
0.25
*57.4 63.5 5.6 1/2 NPTF
HARDWARE WITH MIN 1 NPTF ADD
2.26 2.5 0.22
76.2 1 NPTM
TO MAX MOUNTING HOLES 2 NPTF 25.4
3.00 ADD SEE DETAIL
SEE DETAIL 1.00
6.4 14685 W 105TH ST LEN
14685 W 105TH ST LENEXA, KS 66215 USA CLEARANCE SLOTS FOR
913-888-2630
0.25 913-888-
PROCESS 63.5 ISO-9001 SORINC.C
A ISO-9001 *58.7 SORINC.COM HARDWARE WITH MIN
CONNECTION 2.5
2.31 DRAWN BY

K MITCHELL 76.2
PRODUCT CERTIFICATION DRAWING TO MAX MOUNTING HOLES PRODUCT CERTIFICATION DRAWIN
CHECKED BY 3.00 ALL DIMENSIONS ARE ±1/16 IN
ALL DIMENSIONS ARE ±1/16 IN
J REHM UNLESS OTHERWISE SPECIFIED
1/4 OR 1/2 NPTM UNLESS OTHERWISE SPECIFIED
MM
ENGINEER APPROVAL MM
PROCESS CONNECTION 7.1 LINEAR = S BOAL
LINEAR =
IN
IN
OPTIONAL 0.28 DATE

10 OCT 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. THIS DRAWING IS THE EXCLUSIVE PRO
NO USE WHATSOEVER OF THE INFORMATION CONTAINED NO USE WHATSOEVER OF THE INFORMA
HEREON, NOR REPRODUCTION IN WHOL
A
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. MADE WITHOUT THE EXPRESS WRITTEN P

TITLE TITLE
1/4 NPTF DIMENSION DRAWING 12/52 DIMENSION DRAWING 4/54
FLUSHING NN/N3/N4/PP/P3 NN, N3, N4, PP & P3
PORT DETAIL 2 NPTF EO NUMBER: 5123 DRAWING NUMBER REV 1/4 OR 1/2 NPTM EO NUMBER: 5123 DRAWING NUMBE

0090100 15 PROCESS CONNECTION PROCESS 7.1 009


PROCESS CONNECTION CONNECTION 0.28
SCALE 0.38
SCALE: 0.75 DWG SIZE OPTIONAL SCALE: 1.00
SHEET 1 OF 1 SHEET
DO NOT SCALE PRINT B DO NOT SCALE PRINT

Model Name: 0090100.ASSEM/15/0+ Model Name: 0090110.ASSEM/12/1+

Drawing 0090100 Drawing 0090110


Reset Form

Designators: NN, N3, N4, PP, PF, P3 Designators: NN, N3, N4, PP, PF, P3
Piston Numbers 12, 52 Piston Numbers 4, 54
Housings PP, P3 and PF are General Purpose. Housings PP, P3 and PF are General Purpose.
(Cover gasket is not installed.) MODEL # SALES ORDER #
(Cover gasket is not installed.)LINE ITEM # PURCHASE ORDER #
SALES PAGE 1

108.1
4.25
52.4
2.06 **56.5
2.22 PROCESS
69.9 LENGTH A
28.6 CONNECTION SIZE
2.75
1.13 1/4 NPTM 29.7
33.3 SHOWN 1.17
1.31 26.1
1.03 38.9
1/2 NPTM
1.53
HOUSING
** DIMENSION
GROUP
NN & N3 SHOWN
ELECTRICAL
CONNECTION 4.6
N4 ADD
3/4 NPTF STD 0.18
1/2 NPTF OPT 1.5
PP & P3 SUBTRACT
M20 X 1.5 F OPT 0.06
(BOTH SIDES ON PROCESS * LENGTH * LENGTH
N3 & P3 HSGS) CONN SIZE 1, 5, 6, 9, 56 2, 3
14.0
1/4 NPTF SHOWN ADD
0.55
*146.8 40.5
1.59 13.2 24.1
5.78 1/2 NPTF ADD ADD
0.52 0.95
14.0
9/16 SAE N/A ADD
0.55
23.1
3/4 NPTM ADD N/A
0.91
13.5 7.1 14685 W 105TH ST LENEXA, KS 66215 USA
2X X 913-888-2630
0.53 0.28
MOUNTING SLOTS 7.1 ISO-9001
SORINC.COM
*54.7 0.28 DRAWN BY
2.15 K MITCHELL
PRODUCT CERTIFICATION DRAWING CHECKED BY
ALL DIMENSIONS ARE ±1/16 IN
J REHM
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = S BOAL
IN
DATE

21 JAN 2013
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
A HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE

DIMENSION DRAWING 1/2/3/5/6/9/56

Drawing 0090120
1/4 OR 1/2 NPTM NN/N3/N4/PP/P3
DRAWING NUMBER REV
PROCESS CONNECTION EO NUMBER: 5195
OPTIONAL PROCESS 0090120 22
CONNECTION SCALE: 1.00 DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B

Designators: NN, N3, N4, PP, PF, P3


Model Name: 0090120.ASSEM/22/0+
Reset Form

Piston Numbers 5, 6, 1, 9, 56
Housing PP, P3 and PF are General Purpose.
(Cover gasket is not installed.)
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
**Contact the factory for certified drawings.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 21/32
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.
SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

107.3
Weatherproof - NEMA 4, 4X, IP66 SALE
4.22 MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

52.0 107.3 ELECTRICAL


2.05 10.1 65.6 18.7 HOUSING
4.22 65.6
52.0 CONNECTION 2.58
0.40 2.58 0.74 2.05
69.9 28.6
2.75 28.6 69.9 3/4 NPTF STD
1.12
1.12 RL
2.75 1/2 NPTF OPT
33.3 33.3 LH & RH 26.2 HOUSING
ELECTR
1.31 26.2 1.31 1.03 CONNE
1.03 M20 X 1.5 F
RM 3/4 NPT
RH ONLY RL 1/2 NPT
LH &
3/4 NPTF STD
RN 1/2 NPTF OPT RM
M20 X
RH ONLY ELECTRICAL DETAIL 1 NPTM RH O
ELECTRICAL CONNECTION PROCESS CONNECTION
CONNECTION M20 X 1.5 F SEE CHART SCALE 0.3 3/4 NPT
SEE CHART 1/4 NPTF RS RN 1/2 NPT
RH ONLY RH O
FLUSHING 50.8
PORT 3/4 NPTF STD 2.00
M20 X
RT 1/2 NPTF OPT RS
DETAIL 2 NPTF RH O
*175.9
PROCESS CONNECTION RH ONLY
3/4 NPT
6.92
SCALE 0.5 40.5
*174.5 3/4 NPTF STD 1.59 28.6 RT 1/2 NPT
6.87 RU 1/2 NPTF OPT 1.13 RH O
LH & RH 95.3
40.5 3.75 3/4 NPT
1.59 71.4 RU 1/2 NPT
M20 X 1.5 F CLEARANCE SLOTS 2.81 LH &
RW
CLEARANCE SLOTS LH & RH 6.4
*58.7 FOR HARDWARE M20 X
6.4 0.25 RW
FOR HARDWARE 2.31 M20 X 1.5 F 63.5 LH &
0.25 RY
LH & RH WITH 2.5 MIN
63.5 M20 X
WITH MIN 76.2 RY
2.50 PROCESS 14685 W 105TH ST LENEXA, KS 66215TOUSA
3.00
MAX LH &
* LENGTH 7.1
*57.4 76.2 CONN SIZE 913-888-2630 MOUNTING HOLES
TO MAX SORINC.COM 0.28 14685 W 105TH ST LENEXA,
2.26 3.00 ISO-9001 PIPE KIT 913-888-2630
MOUNTING CENTERS 1/4 NPTF A SHOWN DRAWN BY
PROCESS
OPTIONAL ISO-9001 SORINC.COM
1/4 OR 1/2 NPTM
K MITCHELL
PRODUCT CERTIFICATION DRAWING CHECKED BY PROCESS CONNECTION CONNECTION
ALL DIMENSIONS ARE ±1/16 IN PRODUCT CERTIFICATION DRAWING
1/2 NPTF SHOWN OPTIONAL
M SMITH ALL DIMENSIONS ARE ±1/16 IN
UNLESS OTHERWISE SPECIFIED
37.2 PROCESS
MM
ENGINEER APPROVAL * LENGTH UNLESS OTHERWISE SPECIFIED
5.6 1.47
LINEAR = S BOAL
CONN SIZE MM
1 NPTF ADD IN LINEAR =
IN
A 0.22 71.4 DATE
1/4 NPTF
03 JUN 2011 SHOWN
2 NPTF 25.4 2.81 1/2 NPTF
ADD THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. THIS DRAWING IS THE EXCLUSIVE PROPERTY
SEE DETAIL 1.00 133.4 OF THE INFORMATION CONTAINED
NO USE WHATSOEVER 46.0 NO USE WHATSOEVER OF THE INFORMATION
HEREON, NOR5.25
REPRODUCTION IN WHOLE OR PART MAY BE 1 NPTM ADD HEREON, NOR REPRODUCTION IN WHOLE OR P
1/4 OR 1/2 NPTM PROCESS MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
1.81 MADE WITHOUT THE EXPRESS WRITTEN PERMIS
PROCESS CONNECTION CONNECTION 7.1 PROCESS TITLE
0.28 LENGTH A CLEARANCEDIM
TITLE LENGTH A
OPTIONAL FOR
9.7
DWG #12/52 CONN SIZE DIMENSION DRAWING 4/54
0.31 1/4 NPTM 29.7
R - SERIES W/PIPE KIT OPTION
R-SERIES
1/4 NPTM 29.7
MOUNTING HARDWARE DRAWING NUMBER REV SHOWN 1.17 EO NUMBER: 5123 DRAWING NUMBER

SHOWN 1.17 EO NUMBER: 5090 0090246


0090247 6 38.9 SCALE: 0.69

Electrical 1/2 NPTM


38.9 SCALE: 0.75 DWG SIZE
Electrical 1/2 NPTM
1.53 DO NOT SCALE PRINT
SHEET 1 O

Housing
SHEET 1 OF 1

Housing
1.53
Model Name: 0090246.ASSEM/9/0 DO NOT SCALE PRINT B

Connection Connection
Model Name: 0090247.ASSEM/4/2+
Reset Form

RN, RT, 3/4” NPT(F) RN, RT, 3/4” NPT(F)


Drawing 0090247 RM, RS M20 x 1.5 Drawing 0090246 RM, RS M20 x 1.5

Designators: RM, RN, RS, RT Designators: RM, RN, RS, RT


Piston Numbers 12, 52 Piston Numbers 4, 54
SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

107.3 NOTES:
4.22
52.0 65.6 50.8 1 1. DIMENSION APPROXIMATE AND BASED
2.05 2.58 2.00 ON A FIVE THREAD ENGAGEMENT
69.9 28.6
2.75 1.12 ELECTRICAL
HOUSING
CONNECTION
33.3 26.2
1.31 1.03 3/4 NPTF STD
RL 1/2 NPTF OPT
LH & RH
M20 X 1.5 F
RM
RH ONLY
ELECTRICAL
CONNECTION 3/4 NPTF STD
SEE CHART RN 1/2 NPTF OPT
PIPE KIT
RH ONLY
MOUNTING BRACKET
OPTIONAL M20 X 1.5 F
RS
RH ONLY
3/4 NPTF STD
RT 1/2 NPTF OPT
*171.8 RH ONLY
6.76
40.5 3/4 NPTF STD
1.59 RU 1/2 NPTF OPT
95.3 71.4 LH & RH
3.75 2.81
M20 X 1.5 F
RW
28.6 LH & RH
1.13 M20 X 1.5 F
*54.7 RY
LH & RH
2.15 7.1
0.28 PROCESS * LENGTH * LENGTH 14685 W 105TH ST LENEXA, KS 66215 USA
CONN SIZE 1, 5, 6, 9, 56 2, 3 913-888-2630
ISO-9001 SORINC.COM
14.0
1/4 NPTF SHOWN ADD DRAWN BY
0.55 K MITCHELL
PRODUCT CERTIFICATION DRAWING
PROCESS 13.2 24.1 ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY
A1 1/2 NPTF ADD ADD M SMITH
CONNECTION 0.52 0.95 UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
14.0 LINEAR = S BOAL
9/16 SAE N/A ADD IN
0.55 DATE

06 JUN 2011
37.3 1/4 OR 1/2 NPTM 23.1
1.47 PROCESS 3/4 NPTM ADD N/A THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
0.91 NO USE WHATSOEVER OF THE INFORMATION CONTAINED
71.4 CONNECTION HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
2.81 OPTIONAL
PROCESS TITLE
6.4 1 LENGTH A
133.4 CLEARANCE SLOTS FOR CONN SIZE DIM DWG 1, 2, 3, 5, 6, 9 & 56
0.25
Electrical
5.25 R - SERIES W/PIPE KIT OPTION
63.5 1/4 NPTM 29.7

Drawing 0090245
9.7
Housing
CLEARANCE FOR HARDWARE WITH MIN SHOWN 1.17 EO NUMBER: 5090 DRAWING NUMBER REV

0.31 2.5 0090245 8


MOUNTING HARDWARE TO
76.2
3.00
MAX MOUNTING HOLES 1/2 NPTM
38.9
1.53 Connection
SCALE: 0.75
DO NOT SCALE PRINT
SHEET 1 OF 1
DWG SIZE

B
Model Name: 0090245.ASSEM/6/5+
Reset Form

Designators: RM, RN, RS, RT RN, RT, 3/4” NPT(F)


Piston Numbers 5, 6, 1, 9, 56 RM, RS M20 x 1.5

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

22/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Open Bracket

Drawing 0090007 Drawing 0090017


Designators: H3 Designators: H3
Piston Numbers 12, 52 Piston Numbers 4, 54

Drawing 0090027
Designators: H3
Piston Numbers 5, 6, 9, 1, 56

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 23/32
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Weatherproof - NEMA 4, 4X, IP66

Drawing 0090009 Drawing 0090010


Designators: N6 Designators: N6
Piston Numbers 12, 52 Piston Numbers 4, 54

Drawing 0090020
Designators: N6
Piston Numbers 5, 6, 9, 1, 56

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

24/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Conventional Explosion Proof

MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

SALES PAGE 1 86.1


MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
3.39
137.3 20.6
5.41 0.81
105.9 71.1 ELECTRICAL 6.4
4.17 2.80 CONNECTION 0.25
137.3
5.41 20.6 26.6 3/4 NPTF STD
0.81 1.05 1/2 NPTF OPT
71.1
2.80 ELECTRICAL 6.4
CONNECTION 0.25
3/4 NPTF STD
1/2 NPTF OPT
227.2
8.94

161.1
6.34
80.8 120.7
3.18 4.75
TYP
80.8 40.4
3.18 1.59
40.4 TYP *181.5 TYP
1.59 7.15
*181.5 TYP
7.15
DETA
1/4 NPTF 6.7 1 NPT
FLUSHING 0.26 PROCESS CON
*115.3 PORT *115.3 DETAIL 2 NPTF SCALE
4.54PROCESS CONNECTION CLEARANCE
4.54 CLEARANCE SCALE 0.5 6.4
6.4 FOR MOUNTING 14685 W 105TH
*74.9 FOR *74.9 0.25
0.25 HARDWARE
91
2.95 MOUNTING 2.95 ISO-9001 SO
HARDWARE
14685 W 105TH ST LENEXA, KS 66215 USA PRODUCT CERTIFICATION DR
913-888-2630 ALL DIMENSIONS ARE ±1
PROCESS
ISO-9001 SORINC.COM * LENGTH UNLESS OTHERWISE SPEC
CONN SIZE MM
PROCESS DRAWN BY LINEAR =
* LENGTH K MITCHELL 1/4 NPTF
IN
CONN SIZE PRODUCT CERTIFICATION DRAWING SHOWN
A ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY
1/2 NPTF
1/4 NPTF J REHM
1/2 NPTF
SHOWN AUNLESS OTHERWISEMMSPECIFIED ENGINEER APPROVAL
46.0
THIS DRAWING IS THE EXCLU
NO USE WHATSOEVER OF THE I
LINEAR = S ROOS PROCESS 1 NPTM ADD HEREON, NOR REPRODUCTION I
IN
CONNECTION 1.81 MADE WITHOUT THE EXPRESS W
1/4 OR 1/2 NPT PROCESS 5.6 DATE

MALE PROCESS CONNECTION 1 NPTM ADD 16 MAY 2012 TITLE


0.22 LENGTH A
CONNECTION THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
2 NPTF 25.4 NO USE WHATSOEVER OF THE INFORMATION CONTAINED DIM DWG 4/54 L
OPTIONAL ADD HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE 1/4 NPTM OR 1/2 NPTM 1/4 NPTM 29.7
SEE DETAIL 1.00 EO NUMBER: 5123 DRAWI
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
PROCESS CONNECTION SHOWN 1.17
LENGTH A
TITLE
OPTIONAL 38.9 SCALE: 0.88
DIMENSION DRAWING 1/2 NPTM S
12/52 L 1.53 DO NOT SCALE PRINT
1/4 NPTM 29.7

Drawing 0090146 Drawing 0090145


Model Name: 0090145.ASSEM/6/0+ DRAWING NUMBER REV
SHOWN 1.17 EO NUMBER: 5123
0090146 8
38.9 SCALE: 0.75 DWG SIZE
1/2 NPTM SHEET 1 OF 1
1.53 DO NOT SCALE PRINT B
Model Name: 0090146.ASSEM/6/3+
Reset Form

Designators: L Designators: L
Piston Numbers 12, 52 Piston Numbers 4, 54
SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
PROCESS * LENGTH * LENGTH
CONN SIZE 1, 5, 6, 9, 56 2, 3
14.0
137.3 79.4 50.8 1/4 NPTF SHOWN ADD
0.55
5.41 3.12 2.00
13.2 24.1
133.4 20.7 1/2 NPTF ADD ADD
0.52 0.95
5.25 0.81 14.0
9/16 SAE N/A ADD
71.1 ELECTRICAL 6.4 0.55
2.80 CONNECTION 0.25 23.1
3/4 NPTF STD 3/4 NPTM ADD N/A
0.91
1/2 NPTF OPT
PROCESS
LENGTH A
CONN SIZE
1/4 NPTM 29.7
PIPE KIT SHOWN 1.17
MOUNTING 38.9
BRACKET 1/2 NPTM
1.53
OPTIONAL

80.8
3.18
40.4 TYP
1.59
*178.8 TYP 95.3
7.04 3.75
71.4
2.81
*112.6 28.6
4.43 CLEARANCE
6.4 1.13
FOR
0.25
MOUNTING 14685 W 105TH ST LENEXA, KS 66215 USA
*72.2 HARDWARE 913-888-2630
2.84 SORINC.COM
ISO-9001
DRAWN BY
71.4 CLEARANCE 11.9 K MITCHELL
2.81 7.9 0.47 PRODUCT CERTIFICATION DRAWING
FOR ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY

0.31 J REHM
UNLESS OTHERWISE SPECIFIED
MOUNTING MM
ENGINEER APPROVAL

HARDWARE LINEAR = S BOAL


IN
DATE

A 12 OCT 2012
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
1/4 OR 1/2 NPTM PROCESS
PROCESS CONNECTION CONNECTION TITLE

Drawing 0090144 OPTIONAL DIMENSION DRAWING


1/2/3/5/6/9/56 L HOUSING W/PIPE KIT OPTION
EO NUMBER: 5166 DRAWING NUMBER REV

0090144 10
SCALE: 0.80

Designators: L
DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B
Model Name: 0090144.ASSEM/10/0+
Reset Form
Piston Numbers 5, 6, 9, 1, 56

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 25/32
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Conventional Explosion Proof

SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

142.3 20.6
5.60 0.81
71.1
2.80 ELECT CONN 6.4
3/4 NPTF(STD) 0.25
1/2 NPTF(OPT)
OR PLUGGED(OPT)
(TYP 3)

80.8
3.18
(TYP)

*186.5
40.4
7.34
1.59
(TYP)

*115.3 1/4 NPTF


4.54 26.6 FLUSHING DETAIL
1.05 PORT 2"NPTF
PROCESS CONNECTION
CLEARANCE SCALE 0.5
*74.9 6.4
2.95 FOR MOUNTING
0.25
HARDWARE

14685 W 105TH ST LENEXA, KS 66215 USA


913-888-2630
ISO-9001
SORINC.COM

A PROCESS DRAWN BY

CONNECTION J FIXSEN
PRODUCT CERTIFICATION DRAWING CHECKED BY
1/4 OR 1/2 NPT ALL DIMENSIONS ARE ± 1/16 IN
M SMITH
MALE PROCESS CONNECTION UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
(OPTIONAL) MM
LINEAR = S BOAL
IN
106.0 DATE

4.17 05-05-04
PROCESS
LENGTH A * LENGTH THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
CONN SIZE NO USE WHATSOEVER OF THE INFORMATION CONTAINED
29.7 HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
1/4 NPT(M) = (SHOWN) 1/4 NPT(F)
1.17 SHOWN
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.

38.9 1/2 NPT(F) TITLE


1/2 NPT(M) = DIM DWG #12/52
1.53 5.6
1 NPT(F) ADD S
0.22 DRAWING NUMBER REV
EO NUMBER: 4596

Drawing 0090149
2 NPT(F) 25.4

Drawing 0090148
0090149 6
ADD
SEE DETAIL 1.00 SCALE: 0.75 DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B
Model Name: 0090149.ASSEM/5/3+
Reset Form

Designators: S Designators: S
Piston Numbers 12, 52 MODEL #
Piston Numbers 4, 54
SALES ORDER # LINE ITEM # PURCHASE ORDER #
PROCESS * LENGTH
CONN SIZE 1, 5, 6, 9, 5
1/4 NPTF SHOWN
79.4 50.8
3.12 2.00 13.2
142.3 1/2 NPTF ADD
0.52
5.60 20.6
0.81 9/16 SAE SHOWN
71.1
2.80 6.4 23.1
CLEARANCE 0.25 3/4 NPTM ADD
0.91
6.4
FOR MOUNTING PROCESS
0.25 ELECT CONN LE
HARDWARE 3/4 NPTF(STD) CONN SIZE
1/2 NPTF(OPT) 1/4 NPTM
OR PLUGGED(OPT) SHOWN
(TYP 3)
1/2 NPTM
80.8
3.18
(TYP)
40.4 40.4
*183.8 1.59 1.59
7.23 (TYP)
71.4 95.3
2.81 3.75
28.6
*112.6 1.13
4.43
*72.2
2.84

PIPE KIT 14685 W 105TH ST LE


MOUNTING 913-88
SORINC
BRACKET ISO-9001
A OPTIONAL
PROCESS PRODUCT CERTIFICATION DRAWIN
CONNECTION ALL DIMENSIONS ARE ±1/16 IN
1/4 OR 1/2 NPTM UNLESS OTHERWISE SPECIFIED
PROCESS CONNECTION MM
35.0 LINEAR =
IN
1.38 (OPTIONAL)
Drawing 0090147 71.4
2.81
THIS DRAWING IS THE EXCLUSIVE PR
NO USE WHATSOEVER OF THE INFORM
HEREON, NOR REPRODUCTION IN WHO

Designators: S 133.4
5.25
TITLE
MADE WITHOUT THE EXPRESS WRITTEN P

Piston Numbers 5, 6, 9, 1, 56
DIMENSION DRAWING 1/2/3/5/6/9/56
W/PK
DRAWING NUMB
EO NUMBER: 5195
009
*Refer to Dimensions table on page 19 for changes in length due to process connection size, SCALE: 0.63
DO NOT SCALE PRINT
SHEET

including A dimension. Model Name: 0090147.ASSEM/7/0+

26/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Conventional Explosion Proof


SALES PAGE 1 SALES PAGE
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

PROCESS PROCESS
LENGTH A * LEN
CONNECTION SIZE CONN SIZE
149.5 MIN 106.2 50.8 149.5 MIN 106.2 50.8
5.88 4.18 2.00 1/4 NPTM 29.7 5.88 4.18 2.00 1/4 NPTF
SHOWN 1.17 SHO
133.4 ELECTRICAL 34.0 133.4 ELECTRICAL 34.0 1/2 NPTF
5.25 CONNECTION 1.34 38.9 5.25 CONNECTION 1.34
1/2 NPTM
3/4 NPTF STD 1.53 3/4 NPTF STD 1 NPTM ADD
71.4 MIN 8.7 71.4 MIN 8.7
2.81 1/2 NPTF OPT 0.34 PROCESS * LENGTH * LENGTH 1/2 NPTF OPT
2.81 0.34 PROCESS
CONN SIZE BRASS & ALUM ALL OTHER LENG
CONN SIZE
1/4 NPTF SHOWN SHOWN 1/4 NPTM 29
SHOWN 1.
1/2 NPTF SHOWN SHOWN
38
1/2 NPTM
19.8 5.6 1.
1 NPTF ADD ADD
0.78 0.22
54.0 PIPE KIT
25.4 25.4 54.0
2.13 MOUNTING 2 NPTF ADD ADD
1.00 1.00
TYP BRACKET 2.13
OPTIONAL TYP PIPE KIT
OPTIONAL
108.0
4.25 108.0
TYP 4.25
*202.9 *202.9 TYP
7.99 95.3 7.99
3.75
95.3
71.4 3.75
2.81
*121.7 71.4
4.79 *121.7 2.81
CLEARANCE 28.6 SCALE 0.25 DETAIL 1 NPTM
4.79
6.4 1.13 SCALE 0.25
FOR 28.6
0.25 14685 W 105TH ST LENEXA, KS 66215 USA CLEARANCE
MOUNTING 1.13
*67.7 913-888-2630 6.4
2.67 HARDWARE SORINC.COM FOR 14685 W 105TH ST LENEXA, KS 662
ISO-9001 *67.7 0.25
913-888-2630
2.67
DRAWN BY MOUNTING SORINC.COM
K MITCHELL HARDWARE ISO-9001
PRODUCT CERTIFICATION DRAWING
CLEARANCE ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY DRAWN BY
M SMITH K MITC
7.9 UNLESS OTHERWISE SPECIFIED PRODUCT CERTIFICATION DRAWING
FOR MM
ENGINEER APPROVAL CHECKED BY
0.31 LINEAR = S ROOS CLEARANCE ALL DIMENSIONS ARE ±1/16 IN
IN M SMIT
MOUNTING DATE
7.9 UNLESS OTHERWISE SPECIFIED ENGINEER A
A PROCESS HARDWARE 19 NOV 2012 FOR MM
0.31 LINEAR =
IN S ROOS
CONNECTION THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED MOUNTING DATE

A
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE PROCESS HARDWARE 19 NO
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. CONNECTION THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR
TITLE NO USE WHATSOEVER OF THE INFORMATION CONTAIN
1/4 OR 1/2 NPTM DIMENSION DRAWING 12/52 LC
HEREON, NOR REPRODUCTION IN WHOLE OR PART MA
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF
PROCESS CONNECTION 94.5 W/ HEX NIPPLE & PIPE KIT OPTIONS
OPTIONAL 3.72 TITLE
EO NUMBER: 5195 DRAWING NUMBER REV
1/4 OR 1/2 NPTM DIMENSION DRAWING 4/54 LC
119.4 0090399 5 PROCESS CONNECTION W/HEX NIPPLE & PIPE KIT OPTIONS
SCALE: 0.75
4.70 SHEET 1 OF 1
DWG SIZE
OPTIONAL DRAWING NUMBER
DO NOT SCALE PRINT B EO NUMBER: 5195
Model Name: 0090399.ASSEM/4/0+ SCALE 0.25 0090456
Reset Form SCALE: 0.25
SHEET 1 OF 1
DO NOT SCALE PRINT

Model Name: 0090456_1NPTM.ASSEM/4/0+


Res

Drawing 0090399 Drawing 0090456


Designators: lC SC Designators: LC SC
Piston Numbers 12, 52 Piston Numbers 4, 54
SC shown. LC identical except right-hand SC shown. LC identical except right-hand
electrical connection only. electrical connection only. SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
PROCESS
LENGTH A
CONNECTION SIZE
1/4 NPTM 29.7
106.2 SHOWN 1.17
4.18
38.9
149.5 MIN 34.0 1/2 NPTM
1.53
5.88 1.34
PROCESS * LENGTH * LENGTH
71.4 MIN 8.7 CONN SIZE 1, 5, 6, 9, 56 2, 3
2.81 0.34
14.0
1/4 NPTF SHOWN ADD
0.55
13.2 24.1
1/2 NPTF ADD ADD
0.52 0.95
23.1
1/2 NPTM ADD N/A
0.91
14.0
9/16 SAE SHOWN ADD
54.0 0.55
2.13 23.1
3/4 NPTM ADD N/A
TYP 0.91

108.0
4.25
TYP ELECTRICAL
*200.2 CONNECTION
7.88 3/4 NPTF STD
1/2 NPTF OPT

*119.0 SCALE 0.25


4.68
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
CLEARANCE SORINC.COM
ISO-9001
*65.0 6.4
FOR
2.56 0.25 DRAWN BY

K MITCHELL
MOUNTING PRODUCT CERTIFICATION DRAWING CHECKED BY
HARDWARE ALL DIMENSIONS ARE ±1/16 IN
M SMITH
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = S ROOS
IN
DATE

19 NOV 2012
A THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE

1/4 OR 1/2 NPTM PROCESS DIMENSION DRAWING 1/2/3/5/6/9/56


PROCESS CONNECTION CONNECTION LC W/HEX NIPPLE OPTION
OPTIONAL
Drawing 0090408
DRAWING NUMBER REV
EO NUMBER: 5195
0090408 10
SCALE: 0.75 DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B

Designators: LC SC
Model Name: 0090408.ASSEM/***/***
Reset Form

Piston Numbers 5, 6, 9, 1, 56
SC shown. LC identical except right-hand electrical connection only.
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 27/32
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Conventional Explosion Proof


SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
SALES PA
MODEL # PROCESS SALES ORDER # LINE ITEM # PURCHASE ORDER #
* LENGTH
CONN SIZE
PROCESS
* LE
1/4 NPTF SHOWN CONN SIZE

141.3 1/4 NPTF SH


5.56 1/2 NPTF SHOWN 141.3
5.56
70.6 5.6 1/2 NPTF SH
2.78 88.9 25.0 1 NPTF ADD 70.6 CLEARANCE
0.22 88.9 1 NPTM
3.50 0.98 2.78 6.4 ADD
2X 78.5 2 NPTF 25.4 FOR 3.50 SEE DETAIL
ADD 2X 78.5 0.25
3.09 CLEARANCE 22.2 SEE DETAIL 1.00 MOUNTING
6.4 0.88 3.09 22.2
39.1 FOR HARDWARE 0.88
0.25 39.1 LENGTH A
1.54 MOUNTING LENGTH A 1.54
HARDWARE 1/4 NPTM 2
1/4 NPTM 29.7 SHOWN 1
SHOWN 1.17 3
3X ELECTRICAL 1/2 NPTM
38.9 1
CONNECTION 1/2 NPTM 3X ELECTRICAL
1.53
3/4 NPTF STD 9.8 CONNECTION 9.8
1/2 NPTF OPT 0.39 3/4 NPTF STD 0.39
OR PLUGGED OPT 1/2 NPTF OPT
OR PLUGGED OPT

*184.9 *183.6
7.28 1/4 NPTF7.23 DETAIL 2 NPTF
FLUSHING PROCESS CONNECTION DETAIL 1 NP
PORT SCALE 0.25 PROCESS CONNE
SCALE 0.2
*116.7 14685 W 105TH ST LENEXA, KS 66215 USA
*115.3
913-888-2630 5.2 14685 W 105TH ST LENEXA, KS 66
4.59 4.54 SORINC.COM 0.20 913-888-2630
ISO-9001
DRAWN BY ISO-9001 SORINC.COM
*77.3 *76.0 K MITCHELL DRAWN
3.04 2.99 DRAWING
PRODUCT CERTIFICATION CHECKED BY K MIT
ALL DIMENSIONS ARE ±1/16 IN PRODUCT CERTIFICATION DRAWING
M SMITH CHECKED
UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS ARE ±1/16 IN
ENGINEER APPROVAL M SM
MM UNLESS OTHERWISE SPECIFIED
LINEAR = S BOAL MM
ENGINEE
IN LINEAR =
DATE
IN S BOA
07 JUN 2011 DATE

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.


07 J
NO USE WHATSOEVER OF THE INFORMATION CONTAINED THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SO
A A NOR REPRODUCTION IN WHOLE OR PART MAY BE
HEREON, NO USE WHATSOEVER OF THE INFORMATION CONTA
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. HEREON, NOR REPRODUCTION IN WHOLE OR PART M
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION O
TITLE
TITLE
DIM DWG 12 & 52 1/4 OR 1/2 NPTM PROCESS
1/4 OR 1/2 NPTM PROCESS TA DIM DWG - 4 & 54
PROCESS CONNECTION CONNECTION PROCESS CONNECTION CONNECTION TA
OPTIONAL EO NUMBER: 5090 DRAWING NUMBER REV
OPTIONAL DRAWING NUMBER
0090155 7 EO NUMBER: 5090
SCALE: 0.75 DWG SIZE
0090154
SHEET 1 OF 1 SCALE: 0.75
DO NOT SCALE PRINT B SHEET 1 OF 1
DO NOT SCALE PRINT
Model Name: 0090155.ASSEM/6/3+
Model Name: 0090154.ASSEM/6/3+
Reset Form
Re

Drawing 0090155 Drawing 0090154


Designators: TA Designators: TA
Piston Numbers 12, 52 Piston Numbers 4, 54
SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

88.9
141.3 3.50 22.2
5.56 0.88
70.6
2.78 9.8
(TYP) 2X 7.9 HOLES 0.39
0.31 (TYP)
FOR MOUNTING
HARDWARE

*185.7
7.31
ELECTRICAL
CONNECTION
*115.0 3/4 NPTF(STD)
4.53 1/2 NPTF(OPT)
OR PLUGGED(OPT)
*75.6 (TYP 3)
2.98

14685 W 105TH ST LENEXA, KS 66215 USA


913-888-2630
ISO-9001
SORINC.COM
A PROCESS DRAWN BY

CONNECTION L BROWN
PRODUCT CERTIFICATION DRAWING CHECKED BY
1/4 OR 1/2 NPT ALL DIMENSIONS ARE 1/16 IN
M SMITH
MALE PROCESS CONNECTION UNLESS OTHERWISE SPECIFIED
39.1 MM
ENGINEER APPROVAL

(OPTIONAL) LINEAR = S BOAL


1.54 IN
78.5 PROCESS * LENGTH * LENGTH DATE

04-11-2017
3.09 CONN SIZE 1, 5, 6, 9, 56 2, 3
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
(TYP) 14.0 NO USE WHATSOEVER OF THE INFORMATION CONTAINED

Drawing 0090153 LENGTH A


29.7
1/4 NPT(F) SHOWN
13.2
ADD
0.55
24.1 TITLE
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.

1/4 NPT(M) = (SHOWN) 1/2 NPT(F) ADD ADD


1.17 0.52 0.95 DIM DWG 1,2,3,5,6,9 & 56 TA

Designators: TA 1/2 NPT(M) = 38.9


1.53 9/16 SAE SHOWN ADD
14.0
0.55 EO NUMBER: 5356 DRAWING NUMBER

0090153
REV

Piston Numbers 5, 6, 9, 1, 56 3/4 NPT(M) ADD


23.1
0.91
N/A
SCALE: 0.75
DO NOT SCALE PRINT
SHEET 1 OF 1
DWG SIZE

B
Model Name: 0090153.ASSEM\8.2\2017-APR-11 10:16
Reset Form

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

28/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Explosion Proof

SALES PAGE
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
SALES PAGE 1 DIMENSION APPROXIMATE AND BAS
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER # 150.1 1 ON A FIVE THREAD ENGAGEMENT
DIMENSION APPROXIMATE AND BASED 5.91
1 ELECTRICAL
150.1 ON A FIVE THREAD ENGAGEMENT HOUSING
75.1 CONNECTION
5.91 110.3 50.8
ELECTRICAL 2.95 3/4 NPTF STD
75.1 110.3 11.9 HOUSING 4.34 2.00
CONNECTION B3 & B6 1/2 NPTF OPT
2.95 4.34 0.47 80.0 35.3
3/4 NPTF STD LH & RH
80.0 35.3 3.15 1.39
B3 & B6 1/2 NPTF OPT M20 X 1.5 F
3.15 1.39 LH & RH B4 & B5
40.0 9.5 LH & RH
40.0 9.5 M20 X 1.5 F 1.58 0.38 3/4 PFF
1.58 0.38 B4 & B5 J4
LH & RH RH ONLY
3/4 PFF
J4 PROCESS
RH ONLY LENGTH
CONNECTION SIZE
PROCESS PIPE KIT
LENGTH A 1/4 NPTM 29.7
CONNECTION SIZE MOUNTING
EXTERNAL SHOWN 1.17
GROUND ELECTRICAL 1/4 NPTM 29.7 BRACKET
SHOWN 1.17
EXTERNAL OPTIONAL 38.9
LUG CONNECTION 1/2 NPTM
SEE CHART
GROUND LUG 1.53
38.9
1/2 NPTM
1.53 PROCESS
* LENG
CONNECTION SIZE
PROCESS 41.2
41.2 1.62 * LENGTH
CONNECTION SIZE 2X 9.1
1.62 1/4 NPTF, BSPF, PTF SHOW
2X 9.1 0.36 71.4
1/4 NPTF, BSPF, PTF SHOWN MOUNTING 2.81
0.36
MOUNTING HOLES 1/2 NPTF, BSPF, PTF SHOW
*227.7 28.6
*227.7 HOLES 1/2 NPTF, 8.96
BSPF, PTF SHOWN 1.13
8.96 33.4 ELECTRICAL
1.32 CONNECTION
1/4 NPTF 5.6
1 NPTF, BSPF, PTF ADD SEE CHART
VENT 0.22
CONNECTION 2 NPTF 25.4 33.4
LH & RH ADD 1.32
SEE DETAIL 1.00 4X 9.5 14685 W 105TH ST LENEXA, KS 6621
*122.5 0.38 913-888-2630
*122.5 14685 W 105TH ST LENEXA, KS 66215 USA
26.6 4.82
913-888-2630 MOUNTING HOLES 26.6 ISO-9001
SORINC.COM
4.82 1.05 SORINC.COM 1.05 DRAWN BY
ISO-9001
35.7 K MITCH
DRAWN BY
1.41 1/4 NPTF PRODUCT CERTIFICATION DRAWING CHECKED BY
K MITCHELL ALL DIMENSIONS ARE 1/16 IN
PRODUCT CERTIFICATION DRAWING VENT CONNECTION M SMITH
ALL DIMENSIONS ARE 1/16 IN
CHECKED BY
71.4 UNLESS OTHERWISE SPECIFIED
M SMITH LH & RH MM
ENGINEER APP
UNLESS OTHERWISE SPECIFIED 2.81 LINEAR = S BOAL
MM
ENGINEER APPROVAL IN
LINEAR = S BOAL DATE
IN 01 JUN
DATE

01 JUN 2015 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.


NO USE WHATSOEVER OF THE INFORMATION CONTAINED
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY B
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
A 1 A1
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SO
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE

TITLE DIMENSION DRAWING 4/45/46/54 B/J HOUSING WI


DIMENSION DRAWING 12/52/124/125/126 B/J HOUSING PIPE KIT OPTION
PROCESS 1/4 NPTF 1/4 OR 1/2 NPTM PROCESS DRAWING NUMBER
CONNECTION FLUSHING PORT EO NUMBER: 5248
94.5 1/4 OR 1/2 NPTM EO NUMBER: 5248 DRAWING NUMBER REV PROCECSS CONNECTION CONNECTION 0090284
DETAIL 2 NPTF 0090297 11 OPTIONAL SCALE: 0.69
3.72 PROCESS CONNECTION
PROCESS CONNECTION SCALE: 0.69 SHEET 1 OF 1
OPTIONAL SHEET 1 OF 1
DWG SIZE
DO NOT SCALE PRINT
SCALE 0.25 DO NOT SCALE PRINT
Model Name: 0090284.ASSEM/11.3 B
Model Name: 0090297.ASSEM/10.3 Rese
Reset Form

Drawing 0090297 Drawing 0090284


Designators: B3, B4, B5, B6, J4 Designators: B3, B4, B5, B6, J4
Piston Numbers 12, 52 Piston Numbers 4, 54
SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
DIMENSION APPROXIMATE AND BASED PROCESS
1 LENGTH A
ON A FIVE THREAD ENGAGEMENT CONNECTION SIZE
150.1 1/4 NPTM 29.7
5.91 SHOWN 1.17
75.1 38.9
1/2 NPTM
2.95 1.53
80.0 110.3 50.8 PROCESS * LENGTH * LENGTH
3.15 4.34 2.00 CONN SIZE 1, 5, 6, 9, 56 2, 3
40.0 35.3 1/4 NPTF
14.0
1.58 1.39 1/4 BSPF SHOWN ADD
0.55
1/4 PTF
1/2 NPTF
13.2 24.1
PIPE KIT 1/2 BSPF ADD ADD
0.52 0.95
MOUNTING 1/2 PTF
BRACKET 14.0
7/16 - 20 SAE SHOWN ADD
OPTIONAL 0.55
14.0
EXTERNAL 9/16 SAE SHOWN ADD
0.55
GROUND
3/4 NPTM
LUG 23.1
3/4 BSPM ADD N/A
0.91
3/4 PTM
41.2 95.3 ELECTRICAL
1.62 2X 9.1 3.75 HOUSING
0.36 71.4 CONNECTION
MOUNTING 2.81 3/4 NPTF STD
*225.0 HOLES B3 & B6 1/2 NPTF OPT
8.86 28.6 LH & RH
1.13
M20 X 1.5 F
ELECTRICAL B4 & B5
LH & RH
CONNECTION 3/4 PFF
SEE CHART 33.4 J4
4X 9.5 RH ONLY
0.38 1.32 14685 W 105TH ST LENEXA, KS 66215 USA
*119.9 913-888-2630
4.72 35.7 MOUNTING
HOLES 9.5 ISO-9001
SORINC.COM
1.41 0.38 DRAWN BY

1/4 NPTF K MITCHELL


71.4 PRODUCT CERTIFICATION DRAWING CHECKED BY
VENT CONNECTION 26.6 ALL DIMENSIONS ARE 1/16 IN
2.81 LH & RH UNLESS OTHERWISE SPECIFIED
M SMITH
1.05 MM
ENGINEER APPROVAL
LINEAR = S BOAL
IN
DATE

05 JUN 2015
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
A1 NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE

1/4 OR 1/2 NPTM PROCESS DIMENSION DRAWING 1/2/3/5/6/9/56 B/J HOUSING


W/PIPE KIT OPTION
PROCESS CONNECTION CONNECTION

Drawing 0090882
DRAWING NUMBER REV
OPTIONAL EO NUMBER: 5248
0090882 6
SCALE: 0.65 DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B

Designators: B3, B4, B5, B6, J4


Model Name: 0090882.ASSEM/5.2
Reset Form

Piston Numbers 5, 6, 9, 1, 56

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 29/32
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Weatherproof - NEMA 4, 4X, IP66

Drawing 0090269 Drawing 0090270


Designators: RB Manual Reset Designators: RB Manual Reset
Piston Numbers 12, 52 Piston Numbers 4, 54

Drawing 0090271
Designators: RB Manual Reset
Piston Numbers 5, 6, 1, 9, 56

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

30/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.
Pressure and Vacuum
Switches Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for
certified drawings for a particular model number.

Conventional Explosion Proof

Drawing 0090167 Drawing 0090168


Designators: S Manual Reset Designators: S Manual Reset
Piston Numbers 12, 52 Piston Numbers 4, 54 SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
PROCESS
LENGTH A
CONNECTION SIZE
142.3 79.4
5.60 3.13 1/4 NPT(M) 29.7
71.1 20.7 SHOWN 1.17
2.80 2X ELECTRICAL 0.81 38.9
1/2 NPT(M)
CONNECTION 1.53
MANUAL 3/4 NPT(F) STD PROCESS * LENGTH * LENGTH
RESET 1/2 NPT(F) OPT CONN SIZE 1, 5, 6, 9, 56 2, 3
OR PLUGGED OPT 14.0
1/4 NPT(F) SHOWN ADD
0.55
13.2 24.1
1/2 NPT(F) ADD ADD
0.52 0.95
6.4 14.0
9/16 SAE SHOWN ADD
0.25 0.55
23.1
3/4 NPT(M) ADD N/A
0.91

80.8
3.18
TYP
*209.5
8.25 40.4
1.59
TYP

*112.6 4X 7.94 LENEXA, KS 66215 USA


4.43 0.313 913-888-2630
MOUNTING ISO-9001 SORINC.COM
HOLE DRAWN BY
*72.2 K MITCHELL
2.84 PRODUCT CERTIFICATION DRAWING CHECKED BY
ALL DIMENSIONS ARE 1/16 IN
M SMITH
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = S BOAL
IN
DATE

21 NOV 2017
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR, INC.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON,
NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR, INC.
A
Drawing 0090169
TITLE

DIMENSION DRAWING 1/2/3/5/6/9/56 S HOUSING WITH


1/4 OR 1/2 NPT(M) PROCESS MANUAL RESET
PROCESS CONNECTION CONNECTION DRAWING NUMBER REV
EO NUMBER: 5387
OPTIONAL 0090169 7

Designators: S Manual Reset SCALE: 0.88


DO NOT SCALE PRINT
SHEET 1 OF 1
DWG SIZE

Piston Numbers 5, 6, 1, 9, 56
Model Name: 0090169.ASSEM\6.1\2017-NOV-21 17:31
Reset Form

*Refer to Dimensions table on page 19 for changes in length due to process connection size,
including A dimension.

Form 216 (01.19) ©SOR Inc. SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 31/32
SOR Inc. | Lenexa, KS USA | 913-888-2630 | Fax 913-888-0767 | SORInc.com

REGIONAL OFFICES
China Middle East
SOR China | Beijing, China | china@SORInc.com SOR Measurement & Control Equipment Trading DMCC | Dubai, UAE
+86 10 5820 8767 | Fax +86 10 58 20 8770 middleeast@SORInc.com | +971 4 278 9632 | Fax +913 312 3596

32/32 Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com Form 216 (01.19) ©SOR Inc.