100% found this document useful (1 vote)
336 views46 pages

UKOOA

Uploaded by

Mehulkumar Patel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
336 views46 pages

UKOOA

Uploaded by

Mehulkumar Patel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
UK OFFSHORE OPERATORS ASSOCIATION LIMITED (E&D INSTRUMENTATION COMMITTEE) Guidelines for INSTRUMENTATION, POWER AND CONTROL CABLES FOR FIXED & MOBILE PRODUCTION FACILITIES Acknowledgement In publishing these Guidelines UKOOA gratefully ackowledges the support and assistance given to their preparation by the British Rig Owners Association, the International Association of Drilling Contraetors (North Sea Chapter), and the British Cable Makers’ Confederation. Kvaerner Paddington Standards Dept Issue Nor J [ 0 1 JAN 2001 Location: | NN Gs Guidelines for instrumentation, power and control eables for fixed and mobile LKOOA production facilities Fssue No.2, Novembes19%6 REVISION RECORD ISSUE DESCRIPTION OF REVISION 1 First publication 2 Second edition ‘Guidelines for instrumentation, power and control cables for fixed and mobile production facilities Ise No? Novernberi906 DATE Aug 92 Nov 96 cr oe Contents L Introduction 2. Seope 3. References 34 Precedence 3.2 Codes And Standards 3.3 Glossary 4. Service Conditions 4.1 Environment 5. Technical Requirements 5.1 Cable Rating 3.2 Fire Performance 53 Cable Design 54 Cable Cores 5.5 Sheath Marking $6 Cable Drums 5.7 Cable Gland Compliances 6. Documentation, Certification And Traceability 61 Cattification And Traceability 6.2 Supplier Documentation 6.3 Language And Units Of Measurement 7. Inspection And Testing 71 General 7.2 Test Equipment 7.3 Routine Tests 74 — Sample Tests 7.5 Random Tests 7.6 Frequency Of Test Of Compliance With IEC 331 7.7 Test Witnessing 8. Cable Construction & Selection 8.1 General 8.2 Cable Selection 8,3 Fire Performance Selection 8.4 Termination Methods Guidelines for instrumentation, power and control cables for fixed and mobile LYK COCA, production facilities itt Issue No2 November1996, Annexes A UKOOA CABLE TYPE TABLES FOR STANDARDIZED CORE SIZES AND LAY-UP CONFIGURATIONS B —_- UKOOA INSTRUMENTATION, POWER AND CONTROL CABLE CODING C SPECIFICATION SHEETS Cl C2 C3 ca cs Cé C7 C8 C9 C10 cu C2 CAs cl4 CAS Flame retardant instrementation and control cables 150/250V grade with reduced halogen sheathing, UKOOA fire performance code J Fire resistant instrumentation and control cables 150/250V grade with reduced halogen sheathing, UKOOA fire performance cade F Flame retardant power and control cables 600/1000V grade with reduced halogen sheathing, UKOOA fire performance code I, Fire resistant power and control cables 600/1000V grade with reduced halogen sheathing, UKOOA fire performance code X Flame retardant instrumentation and control cables 150/250V grade with low smoke and fume sheathing, UKOOA fire performance code K Fire yesistant instrumentation and control cables 150/250V grade with low smoke and fame sheathing, UKOOA fire performance code G Flame retardant power and control cables 600/1000V grade with low smoke and fame sheathing, UKOOA fire performance code W Fire resistant power and control cables 600/1000V grade with low smoke and fume sheathing, UKOOA fire performance code Y Serial Data Cable (Special) Flame retardant power cables 8.7/15 kV grade with reduced halogen sheathing, UKOOA fire performance code H Flamne retardant power cables 3.8/6.6 kV grade with reduced halogen sheathing, UKOOA fire performance code M Flame retardant power cables 1.9/3.3 kV grade with reduced halogen sheathing, UKOOA fire performance code N ! Flame retardant power cables 6.35/11 kV grade with reduced halogen sheathing, UKOOA fire performance code P Flame retardant unarmoured cables 600/1000V grade with reduced halogen sheathing, UKOOA fire performance code L Flame retardant unarmoured cables 600/1000V grade with low smoke and fume sheathing, UKOOA fire performance code W D ‘CABLE PARAMETERS REQUIRED FOR SUPPLIER DATA SHEETS Guidelines for instrumentation, power aud controt cables for fixed and mol production facilities sue No Novembert996 1, Introduction These Guidelines have been developed in response to the offshore industry's desire to standardize cable types for instrumentation, telecommunications and elecivical power and control. It may be wed as a self-standing document by offshore Operators, rie owners, design contractors and equipment builders. Altematively, it may form the basis of user standards in part or whole. Tn 1987, a cable standardization working group was drawn from representatives of UKOOA, .the British Rig Owners Association (BROA) and the Intemational Association of Drilling Contractors (North Sea Chapter) (ADC). The remit was to define a small, logical series of cables which would mect the needs of modern instrumentation equipment and installation practice, whilst boing efficient to manufacture. Historically, users were found to have in-house standards with little in common, even varying widely from one installation or. projeét to another. Many thousands of different cable gore and make-up combinations resulted, not considering the further complications of gheath materials and colour variants, A further UKOOA working group has agreed standards for high and low voltage power cables which have been incorporated into the enlarged second revision of this Guidance. Strict adherence by users to these Guidelines will enable cable manufacturers and stockists to concentrate on providing acceptable cables ‘off the shelf to service the offshore industry. Cable types have been categorized into four basic combinations according to materials of construction, based on their fire performance. It is recognized that development of improved insulation materials should not be restricted by standards. Although certain materials are suggested, equivalent or superior materials may be agteed between Purchaser and Supplicr. Instrumentation may be installed on vibrating machinery, periodically dismounted for calibration and maintenance, whilst miniaturization increasingly, results in restricted termination space. Consequently, for the smaller cored cables (up to 1.5mm?) the use of flcxible stranded conductors to BS 6360 Class 5 has been selected throughout. This is an important departure from historic practice and has also been recognized in BS 6883:1991. ‘With weight and cost saving a consideration, reductions in core size of instrumentation cables were agreed. Standardized construction arrangements for screens and lay-up of cores were evolved in association with representatives of the British Cable Makers! Confederation, these now being shown in BS 6883:1991 as preferred types, ‘To ease manufacture and further reduce size, quads have replaced to 2-pair cables. Whilst every effort has been taken to ensure the accuracy of these Guidelines, UKOOA cannot accept responsibility for any errors or omissions. Duty holders and designers should ensure that in selecting and using the standards set out in these Guidelines that they are suitable for their intended service. Guidelines for instrumentation, power and control cables for fixed and mobile protic ea UKOOA ed 2. Scope These Guidelines cover the requirements for the design, manufacture, inspection and | testing of elastomeric instrumentation, power and contro! cables “for offshore installations. It is not intended to define how or where cable types should be applied | and itis the responsibility of users to cnsure that cables are fit for purpose. These Guidelines are complomentary to BS 6883:1991 which covers the general and detailed construction of elastomeric cables. A sub-sot of the innumerable option combinations is defined to enable standardization on a coherent family of cables which will satisfy the majority of instrumentation, power, telecommunications and control applications. ‘Although not covered by BS 6883, these Guidelines incorporate information on data cable for use in computer networks and data highways such as Ethernet. Guidelines for instrumentation, power and control cables for fixed and mobi production facitities 7 IssueNo? Novemeri996 3. 3A 32 References Precedence These Guidelines are complementary to the accompanying specification sheets and the specifications, regulations, codes and standards referenced herein. ‘The order of precedence shall be: i Statutory Regulations . Purchasing specification sheets These Guidelines iv Referenced codes and standards Codes and Standards All materials supplied shall conform to the latest editions of the following, as applicable: British Standards 7 BS 1442:1969 Galvanized mild steel wire for armouring cables BS 2873:1969 Specification for copper and copper alloys: Wire BS 4109:1970 Specification for copper for electrical purposes. Wire for general electrical purposes and for insulated cables and flexible cords BS 4727: Glossary of electrotechnical, power, telecommunications, electronics, lighting and colour terms Part 2: Terms particular to power engineering Group 08:1986 Electric cable technology BS 5345: Selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres Parts 1 & 2 BS 6360:1991 Specification for conductors in insulated cables and cords BS 6425: Methods of test for gases evolved during combustion of electric cables Part 1:1990 Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables ‘ BS 6469: Insulating and sheathing materials of electric cables, Part 1: Methods of test for general application Section 1.1:1992 Measurement of thickness and overall dimensions. Tests for determining mechanical propertics Section 1.2:1992 Thermal ageing methods Part 2: Methods of test specific to elastomeric compounds Section 2.1:1992 Ozone resistance test. Hot set test. Mineral oil immersion test Part 99: Test methods used in the United Kingdom but not specified in Parts 1-5 Section 99.1:1992 Non-electrical tests BS 6883:1991 Specification for elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units! In course of revision Guidelines: for ‘umentation, power and control cables for fixed and mobile UKOOA production facilities 3 Issue No.2 Novenber996 13S 7622:1993 Measurement of smoke density of electric cables buming under defined conditions Part 2: ‘Test procedure and requirements BS 7655:1993 Insulating and sheathing materials for cables Patt 2: Elastomeric sheathing compounds Section 2.6:1993 Sheathing compounds for ships wiring and offshore applications BSEN1S0 9001 Quality Systems:Specification for design/development, production, installation and servicing, BS EN 1S0 9002 Quality Systems: Speci ion for production and installation The Institution of Electrical Engineers Recommendations for the electrical and electronic equipment of mobile and fixed offshore installations International Electrotechnical Committee IEC 331 Fire resisting characteristics of electric cables IEC 332 Tests on electrical cables under fire conditions. Part 3: Tests on bunched wires or cables 33 Glossary 3.3.1. The following abbreviations are utilized in these Guidelines: csp i Chlorosulphonated polyethylene EPR Ethylene propylene rubber GSWB Galvanized steel wire braid 1s Intrinsically safe LSF Low smoke and fume MGT Mica glass tape PBWB Phosphor bronze wire braid PETP Polyethylene terephthalate PTFE Poly-tetrafluoroethylene 3.3.2 Detailed definitions of cable construction terms are listed in BS 4727: Part 2: Group 08 and BS 6883:1991 Guidelines for instrumentation, power and control cables for fixed and on production facilities 4 Issue No2 Nivernbec996 se = a a om ln le ll ele ee le ek Ce UE ee Oc 4. Service Conditions 4.1 Environment Cables shall be suitable for operation for a period of at feast 20 years under the following environmental conditions: 4.1.1 Typical Ambient Air Temperature Rang Indoos (enclosed with heating) max 40°C mic ‘Outdoor max 22°C min 41.2 Service Temperatures Design max 85°C min 4.1.3 Humidity 100% max; marine environment, saliferous and conosive 4.1.4 Mineral Oils 7 Hydraulic oil, crude oil, diesel oil. Guidelines for instrumentation, power and control cables for fixed and mobile eecen eeu : UKOOA en! Novemeri990 Technical Requirements The requirements of these Guidelines shall not relieve the Supplier of the responsibility ‘of complying with industrial codes and standards, 5. Cable rating S.L.1 Cable ratings shall fall into six voltage grades, as defined in Annex A, Tables | - 5, according to cable construction: 130/250 V insulation for pairs, triples and quads 6600/1000 V insulation for single and multicores 1.9/3.3 kV insulation for single and multicores 3.8/6.6 KV insulation for single and multicores, 6.35/11 KV insulation for single and multicores 8.7/1 5 KV insulation for single and multicores 5.1.2 Multicore cables (1.5mm? and greater) shall be suitable for the minimum current ratings as listed in IEE Recommendations for the Electrical and Blectronic Equipment of Mobile and Fixed Offshore Installations, Table 12.3 for 60 Hz and 45°C. Bunching factor (more than 6 multicore cables only) 0.85 ; Ambient of 40°C 1.05 5.2 Fire performance 5.2.1 All cables shall be designed for minimal fume emission and toxicity under exposure to flame in a fire condition according to their performance type. 5.2.2 All cables shall have the following minimum performance characteristics: HCI emission: 5% max by weight of gas given off at 800°C 8% max by weight of gas given off at 1000°C Fire Performance: IEC 332 Part 3: Category A test Note:These characteristics, together with enhanced oil resistance, will generally be met by sheathing materials to BS 7655 Section 2.6 Type SW2. 5.2.3 Fire resistant cables (Fire performance Codes F, G, X and Y per Annex B) shall additionally meet the following performance characteristic: Fire Performance: IEC 331 4 5.2.4 Low smoke and fume cables (Fire performance Codes G, K, Wand Y per Annex B) shall additionally meet the following performance characteristics: HCI emission: 0.5% max by weight of gas given off at 800°C Smoke emission: Less than limits for Types SW3 and SW4 compounds. Mininvum transmittance per test method BS 7622 Part 2:1993 shall bc 60% for cable diameters up to 70 mm, 50% for greater diameters. Note:These characteristics, together with enhanced oil resistance, will generally be met by sheathing materials to BS 7655 Section 2.6 Type SW4. pliaa Saat : UKOOA ae ‘November1996 we Ee a a ze. ee Se 53 Cable design 53.1 All materials utilized in the construction of the cables shall be to the latest specifications, now and in current production. Matetial scheduled for modification shail not be used, unless approved by the Purchaser. 5.3.2 Bedding and any fillers shall effectively fill the interstices of the cable and, where practicable, bedding should be the same colour as the sheath. Light blue bedding shall not be used for other than blue sheathed (intrinsically safe) cables. 5.3.3 Braided galvanized steel wire armouring shall be provided in accordance with BS 1442 for all multicore cable types. Single core armoured cables shall employ braided tinned bronze wire type PB102 to BS 2873. 5.3.4 Instrumentation cable screens shall be metallized PETP (usually aluminium or copper coated) tape-with a stranded tinned copper drain wire as defined in BS 6883, with the metallized surface in contact with the drain wire. For Imm* cable conductor size, the ‘drain wire stranding shall be 0.75mm?; for 0.75mm? conductor, the drain ‘wire shall be 0.5mm’, The drain wire shall comprise a minimum of twelve strands, 53.5 The Supplier shall ensure, by ineans of tapes. or other agreed methods, that the cable make-up is designed to afford ease of stripping, termination, removal of outer sheath, wire braid, ete. Supplier shall fully detail cable design by means of across-sectional drawing, see Annex D, 5.3.6 Screens for HV cables shall be of the extruded type in accordance with BS 6883. 4.3.7 Individually screened cables shall retain their inter-screen insulation under: worst. case bending conditions. The design should incorporate any necessary additional plain taping to prevent adjacent drain wires or conductive tapes from shorting. 5.4 Cable cores 5.4.1 Conductor make-up for core sizes up to and including 1.5mm? shall be flexibly stranded using tinned copper to BS 4109, thc maximum wire diameters complying with BS 6360, Class 5 as summarized in Section 5.4.3. 5.4.2 2.5mm conductors and greatet shall be stranded using tinned copper to BS 4109, stranded generally in accordance with BS 6360, Class 2 as summarized in Section 5.4.3. For core sizes 25mm? and greater, the conductors shall be compacted annealed copper. Guidetines for instrumentation, power and contro! cables for fixed and mobile LK OOA Produetion facilities 7 Issue No November 996 3 Circular section core stranding information is summatized in the following table: Nominal eross | Minimum | Nominal eross | Minimum seetional area | numberof | sectionalarea | number of nm) strands (um?) strands 078 4 70 19 10 2 9s 19 1s 30 120 37 28 7 150 7 4 7 185 37 6 7 240 a 10 7 300 a 16 7 400 a 25, 1 300 a 35 1 630 1 50 19 5.4.4 Cores of collectively screened, individually screened and 1.5 mm* multicores shall be identified by indelible, contrasting numerals and words which shall be repeated at intervals as defined in BS 6883 along whole Jength of cable. Core colours shall be as follows: Municore | White Pai Black, White ‘Triples Block, White, Red Quads Black, White, Red, Blue 5.4.5 Power cables (2.5 mm? and greater) shell be numbered on white cores or, if specified by Purchaser, colour coded as follows: Single core _ | White ora otherwise specified Twoeore | 12 Threecore | 1.23 | Red, Yellow, Blue Fourcore | 1,234 _| Red, Yellow, Blue, Black Multicore | White, mimbered Guidelines for instrumentation, power and control cables for fixed and mobile proton tes “ UKOOA Issve No.2 Novernber} 996 55 56 Sheath marking 1 ‘The outer sheath of the cable shall be legibly and permanently marked, by embossing or indelible, solvent-resistant bold printing, 8.52 The following minimum information shall be marked at the intervals specified in BS 6883: (@)_ manufacturer's name (&) UKOOA Cable Code from Annex B {0) voltage grade (@)_ UKOOA Cable Type Code per Annex A and cross sectional area (©) BS 6883 (where compliant) (D. TEC 331 or 12C332 (as appropriate) (g) fire survival.cables may also be marked PS... Example: : sun Bright Spark Wire C°-KOOA JKTOO - 150/250V - 77S x 0.75 - BS 6883 -IEC 332... Cable drums é 5.6.1 The Supplier shall specify its standard cable production lengths and respective drum types and sizes for the quantities of each type of cable required. All drum lengths stated shall be continuous. Cable or conduetor jointing in any form is unacceptable. 5.6.2 Cable drums shall cach be provided with two minimum 150mm x 100mm identification labels made from laminated plastic or similar durable material, securely affixed one per side and at the top and bottom of each drum. 5.6.3. Each drum label shall be engraved or indelibly marked with the following information as a minimum: (a) Purchaser's Drum number see Section 5.6.4 (b) Supplier's name (6) cable cross sectional area (mm?) (a) voltage grade (e) Purchaser's stock number (® Purchase order umber/item number (g) drum length (metre) (B) nett and gross weights (kg) (weight per metre (kg) (date of manufacture 5.6.4 Purchaser's drum number shall be in the following format in minimum 10mm high lettering: UKOOA Cable Type per Annex 4, Tables 1 - 6 oan bae UKOOA Cable Code per Annex B, followed by a Ieeoo! Nees. sequential drum number eg: 150/250V flame retardant EPR/CSP/GSWB/CSP, a o se | Wiss collectively screened, 3 pair, 0.75mm?* cable, drum number 32. Guidelines for nstrumentaan, power and control cables for fed and mobile (yf OOA 9 Novereri906 5.7 Cable gland compatibility $.7.1 ‘The Supplier shall provide fully toleranced dimensional detail of the cable outer diameter and diameter under braiding. 5.7.2 The Supplier shall provide cable gland sclection dotails for all eables on the cable specification sheets based on Ex d type glands. 5.7.3. Cable shall be strictly dimensionally controlled to cnsure complete compatibility between cach cable size and gland size given on the cable specification sheet. Guidelines for trumentation, power and control eables for fixed and mobile produetion facilities 0 OOA Issue No.2 Noweniberi996 . 61 62 63 Documentation, Certification And Traceability Certification and traceability GAA As a minimum, matcrial certification and aceability requirements shall be in accordance with BS 6883. 6.1.2. The cable manufacturer shall operate a quality system in accordance with, und bc accredited to, BS EN ISO 9001 and 9002 6.1.3 Stockists of cables meeting this specification shall operate a quality system in accordance with, and be accredited to, BS EN ISO 9002. Supplier documentation 6.2.1 The Supplier shall provide fully completed Instrumentation and Control Cable Data Sheets for each cable type purchased. Information required and typical format is shown in Annex D. 6.2.2 ‘The Supplier shall provide the following mechanical data: (@) maxiium pulling tension (©) minimum pulling bend radius (©) minimum installed bend radius (@) construction cross sectional drawing showing overall sheath diameter and diameter under armour with tolerances. 6.2.3 The Supplier shall provide documentation in accordance with the Purchasers requirements which shall include, as a minimum, test data defined in Section 7. Language and units of measurement 6.3.1 All drawings and documents shall be expressed in the English Language and ‘units of measurement shail be in accordance with Systéme Intemational (SI). strumentation, power and conttol exbles for fixed and mobile LIK OO A mi u Novembe1996 7. Inspection And Testing 7.1 General 7A. Full documentation detailing the test results shall be provided by the Supplier to the Purchaser. It should be noted that the supplier of cable meeting these Guidelines may be a stockist rather than the manufacturer. 742 The manufacturer shall cary out tests on the cables being supplicd to demonstrate to the Purchaser, or his approved representative, that the requirements of these Guidelines have been fulfilled. The manufacturer shall submit a quality plan which shall include details of ail tests that would be carried out on the materials and during the cable production phase. This document must be submitted and approved before production can proceed. 7.2 Test equipment 7.2.4 The Supplier shail provide all necessary test equipment and personnel to carry out the tests listed below. 7.3 Routine tests 7.3.1 Routine tests shall be performed on all finished cable lengths in accordance with methods lescribed in BS 6883. These tests shall include, as a minimum: @) (b) © @ conductor resistance test voltage test on complete cable insulation tests partial discharge test (HV cables only) 7.3.2 The following shall be carried out as a minimum: @) (b) © @ © © (@) hy @ @ & 74 Sample tests measurcment of conductor and armour resistance high voltage test on complete cable measurement of insulation resistance of compiete cable cable marking shall be examined to ensure correctness bending test Iong time voltage test flame retarding/tesistance tests on sheath (see Section 7.5) oil immersion test on sheath ageing test is smoke emission test (see Section 7.5) fire test (see Section 7.6) 7.41 Manufacturer shall perform tests on one sample taken from cach end of a manufacturing series of the same type and size of cable, Tests required shall include: @ () 1) @ ‘Visual Inspection ’ Measurement of cable dimensions to include insulation, sheath, armour and overall diameter Gland fit verification Tensile strength Guidelines for instrumentation, power and control cables for fixed and mobile production facilities n U OOA ered Noveriberi996 mn ht zz lc Ue Ce Ue 74.2 ‘the Supplier shal advise test methods andl results for the following performance chacacteristies of all cable types specified: (a) Temperature Index (b) Toxicity Index 7S Random tests 7.5.1 Tests are to be performed on samples chosen on a random basis at the Purchaser's discretion to prove fire resistance, flame retardance, hydrochloric acid and smoke emission. 7.6 Frequency of test for compliance with IEC 331 7.6.1 Cable selection: 10% of total numbers of types and sizes shown on order accented towards smaller sections and instrument cables. Selection of cables to be tested to be made by Purchaser. 7.6.2 From cach main prodiiction run of the selected cables, two samples for test shall be taken, one from the'first length and one from the last length. 7.6.3 If the selected cable should fail the test then one re-test shall be carried out to the satisfaction of the Purchaser. If this is not achieved the cable shal! be rejected. In addition one sample shal! also be taken from an entirely new cable the next size up or down to the failed cable, and this will then be subjected to the test. 7.7 Test witnessing 7.7.1 The Purchaser, or his approved representative, reserves the right to attend and witness any such tests at their discretion. Guidelines for instrumentation, power and control cables for fixed and mobile ele i UKOOA & Cable Construction & Selection 81 General B.LL Sample specification sheets are provided in Annex C to assist manufacturers, stockists and users to select cables for various applications. The insulation, bedding and sheathing materials may be substituted by other equivalent compounds which comply with the specifications. The sheets detail only the general construction of cables: manufacturing methods may dictate the addition or omission of proof or PETP tapes, for example. 8.1.2 Four basic fire performance types are subdivided by voltage rating into cable specification sheets for the following typical applications: (a) intrinsically safe (18) instrumentation (b) non-IS instrumentation (6) LV power and control @ HV power (e) other special applications High voltage cables are only listed as standard types in flame retardant, reduced halogen construction. Other variants are not covered by this guidance, being regarded as non-preferred, reflecting the greatest usage pattern. 8.1.3 Apart from the sheath and bedding colour being blue rather than grey, IS cable types ‘are identical to their non-IS counterparts. Some’ users may elect to standardize on grey sheath cables alone. Note that the large core, unscreened multicore (UKOOA Type ©) cables are not normally applicable to 1S circuits and hence no blue sheath variants are recommended. 82 — Cableselection 8.2.1 Cable make-up combinations should be strictly limited to those shown in Avanex A, Tables 1-5. 8.2.2 _It-will be noted that cables such as 2-pair screened ate not inchided as standard types. Reference to Annex A, Table 7 suggests use of 1-quad, this being more compact and easier to manufacture. Where individual screening is essential, 3~ paif cable may be selected. 8.2.3. For general instrumentation applications, overall screened, paired cables (UKOOA Type P) provide adequate noise rejection for use in most switch circuits and analogue loops. i 8.2.4 For high frequency, very small signal and other special applications, individually screened (UKOOA Type PS, TS, QS) cables should be considered. 8.2.5 It is suggested that unscreened multicores (UKOOA ‘Type C) only be applied to instrumentation service where their high current or voltage grade is a requirement. Such applications would typically include switchgear control circuits and high power, non-IS instrumentation. 8.2.6 A range of single core, unarmoured cables is intended for use as carthing cables (UKOOA Type E), battery Ieads and other heavy duty applications not requiring mechanical protection (UKOOA ‘Type B). Core sizes below 6 mm’ are not covered by this guidance and it is recommended that the preferred series of core sizes be adopted for standard use (see tables in Annexes A & B, unshaded items) Guidelines for instrumentation, power and control cables for fixed and mobile proto ite i UKQOA November10046 ——— oO a a a ee %3 Mire performance selection 8.3.1 Users should select fire performance types according to the individual application, Sections 8.3.2 - 8.3.5 offer gencral guidance only. 8.3.2 For most general power and instrumentation applications in ventilated areas, reduced halogen, flame retardant cables (Fire performance codes H, J, L, M, N and P per Annex B) offer adequate performance, 83.3 Where continuity of circuits is essential under fire conditions, reduced halogen, fire, resistant cables (Fire performance code F and X per Annex B) should be conisidered, Typical applications may include: (a) fire pump start circuits (b) deluge and extinguishant release (©) public address and general alam systems (d) essential telecommunications equipment (©) _power-o-opérate shutdown circuits () essential LV power supply feeders 83.4 Where cables may present a smoke or fume hazard under fire conditions, Fire performance codes G, K, W and Y may be specified to replace codes F, J, L and X respectively. Some users may elect to use these types for all applications. Some LSF materials possess lower tear strength than their reduced halogen counterparts, e.g: CSP, It is expected, however, that with developing materials technology, that performance of LSF materials will meet or exceed that of CSP. Cables with sheathing compounds possessing the properties of both BS 7655 Section 2.6 types SW2 and SW4 may be dual marked with both UKOOA Cable Codes with which they comply. Ba Termination methods 8.4.1 Flexibly stranded cores (ie: those less than 2,5mm*) which are to be terminated at clamp type terminations should be crimped using bootlade ferrules matched to the core size. These have the advantage of being secoudarily mechanically compressed by tightening the terminal screw or gate;’ the cores are thus intcinsically secure. The resulting installation is generally more compact. 8.42 Bootlace ferrules with colour-coded insulated wire enties are preferred and provide: (a) improved guidance for the core strands on assembly (b) visual recognition of correct cross-sectional area ferrule to match core size (0) support for the insulation and retention of numbering sleeves (@) additional protection ftom electric shock and shorting 8.4.3 All crimped terminations shall be made off using adequately maintained, manufacturer's recommended tooling, compatible with the size of core. ooeten ete UKOOA pte Aunex A. D CORE SIZES AND LAY-UP UKOOA CABLE TYPE TABLES FOR STANDARD! CONFIGURATIONS: AL UKOOA Cable Types are designated by the number of cores, pairs, triples or quads followed by one or two letters. The letter codes are as follows: C —— Unscreened cored cable P Paircable B Battery cable (single core only) T Triple cable E __Earthing cable (single core only) Q Quad cable S Individual soreening of pair, triple or quad (added as suffix to P, Tor Q) eg: Type 7PS is an individually screened 7 pair, whereas type 7P has a callective screen. Single pair cables are treated as individually screened (Type IPS). Triples and quads are always individually screened and designated TS and QS. A2 Only cable core lay-up and size combinations shown in the following tables shall be used. A3 Shaded areas without Code number entries signify non-available combinations, NOT covered by these Guidelines. Light shaded areas denote non-preferred types. A Codes in Tables.1 - 6 relate to the Cable Coding system defined in Annex B. Permitted combination options of Ist & 2nd characters (chown as ** in the Tables below) are given in Sectibns 4.5 and A.6. A.5 — Istand 2nd character combinations permitted in Cable Codes are: FABLE 5 Nonis [LV Poweronol] Baring] Batiery iy we | (ightbtuey | 2301250v) | (oavta00v) (coariooov) Power Te TAL TEL WA, WB WE, WF ny XC, XI YC, YD z 36, KG KT FL, GL FA, GN aS RT TERE M,GM Fr, GP e HA, HB, MA, MB NA,NB, PA, PB A LY cable types except battery and earthing cables (Type 1B and 1E) may be manufactured in flame retardant (Ist character J’, K, L or W) or fire resistant (Ist character F, G, X or Y) variants, The 2nd character in Cable Codes defines cable internal construction per Annex B. Note that for fire resistant power cables detailed in Table 1b, a reduced range is preferred. A.7— Gland sizes shown in Tables 2 - 5 are proferred but may be varied smaller, subject to agreement between Supplier and Purchaser, according to materials of construction. wronctn 7 UKOOA pes Novemberi996 TRICE URSCRERED COTES PEATE RETARDANT 600/1000 V POWER & CONTROL (C), BATTERY (1B) & EARTHING (IE) CABLES Ta CROOK ECT sss LTTE ee RCL RCL AC Lae Ss Tae eon [3 7 se Tr FE 2s #403 | +4703 2 see , ae wo vo 16 4 #9216 | #316 | *416 2s tas | ae | ss 33 wrasg | 29335 | +435 2 fs » “ten |e | - 2 rs on | ion , 150 185, 930 | *#40C i a bao ne >on oe | soe ‘on “0 : & : BLEW URSCRENED CON FIRE RESISTANT tuna V POWER CONTROL CABLES os UKOOA Cte Ti extent [TOT ep = Naame (mm) 1 2 3 fi 7 2 Tea ar Twa a 08 srs | ora é io te Fs 3s s » 2s 2 18 mes 20 300 ‘on an 630 Guidelines for instrumentation, power and control cables for fixed and mobile production facili 0 sue No? Novembert996 150250V INSTRUMENTATION & CONTROL CABLES: TROGT Wor Tibss Sectional aca Gam) Gina Cable Type pairs OF CM thee size w 3 TiHioe cy RP 7 +1400 23 WP 2 KOU 32 20° 29 100 0 23 27 3400 0 amr 7 seN00 30. “TABLES INDIVIDUALLY SCREENED PAIRS 150/250V INSTRUMENTATION & CONTROL CABLES Wor Crass sectional area Gm) Gant pais ay T CM thread size i POT 2 3 *4H100 0 7 “+100 25 2 o*K00 2 TARGET IOIVIDUALLY SCREENED TRIPLES 150/250V INSTRUMENTATION & CONTROL CABLES. TKOOR Wet “Cross sectional area (rm) Gand Cable Type tviptes OTF 7 OM thread size TIS T WT 31s 3 **S00 5 78 1 +700 2 vrs 2 **U00 40 TABLES INDIVIDUALLY SCREENED QUADS 150250V INSTRUMENTATION & CONTROL CABLES. UROOK Wot ‘Cross SeeATonaT area (me) Cine Cable Type quads Os CM thread size igs 7 ar 2 398 3 **Y00 2s 798 1 700 40 produ sue No Novemberi996 mn facilities 18 Guidelines for instrumentation, power and control cables for fixed and mobile LW OOA, FADLES ~TTANP RETARDANT SINGLE AND THREE CORE HIGH VOLTAGE POWER CABLES Voltage rating THAT Tae Baste SHE TROGH Ea HB335 she HHE370, HOA BBE) HBI0C | pel TABLET SUMMARY BYN* OF CORES Taal TROOA Cable Type of cores Unseiecned | Gallecinvesercca | Tndividual screen T IG TE 2 26(1.54) TPS 1S 3 3c (1.54) is ITs 4 40(1.54) 198 198 6 3P 3P5 7 “7G (15,25 only) 9 37S, 2 2c (1.3,2.5 only) 398! 4 7P 7s; 9 F9C (15 only) a 713 24 iP rps 27 ‘27 (1.5 only) 28 708 36 RTs 37 "BIC (15 only) 40 20? 54 2 ” 37P. Guidelines for instrumentation, power and control cables for fixed and mobile production facilities 9 Ineve Nod y Noverber1996 Annex B UKOOA INSTRUMENTATION, POWER AND CONTROL CABLE CODING All eable types shall be uniquely defined by a five character alpha-numeric vode, constructed as follows 12 Ist character Fire performance/Voltage rating 2nd character Cable construction 3rd character N* of cares; pairs, triples, quadruples Le | ‘th & 3th characters Conduetor cross-sectional area Ist character F Fire resstn, reduced balogen ‘sons0v G —_Fiteresistan, low smoke and me 1307250 HH Flame retardant reduced logon 7ASKV JF Flame retardant, ried halogen 50050 K —Flameretartint fowsmokeand 150250 fume L Flame retarang reduced halogen 600/1000 V 2nd character Basie Construction sm so ee Romo M N P y lome retardant lane rtadane Fir resistant Fire resistant Flame retardant Flame retardant lame retardant Flame retardant Flame veacdant lame retardant Fire resistant ire resistant Fire resistant Fire resistant Flame retardant Sheath Colon Bac (606/1000), Red (HV) Blac (600/1000V), Red °V) Black 600/1000¥) Black (co0"i000vy reen/¥ellow lack Light bie Liphebioe Grey Grey Light blue Light bine Gey Grey Orange M_——Plane renin eduedinogn 3816680 N ane roaren reed tages LASKY F —Rmortrdanyredvcedinogen 6357149 W —Paesenatonsntem conto X —eeressan,eucodinopn 6002000 Y—Preresidso ovstoke ana me o000 ARH |IH| 1] BEPER Annex A Tabs Bon rid See ia cows Skee? 6 ones bid Sie Noe swan SeeNe Nowe None ta Now | None tn GSWB g Collective 2 swe + Indu aas oswn —Caletve 2 8WR Ind aas cswB Callan 2 sw Indvial aas swe Collate a swe Invi 34s sw Coat peramexed —- Guidelines for production facilities Issue No Noveniberh996 strumentation, power and contol cables for fixed and mobile UB C}O A, 20 bra character t le cone Be Wome K pair T Thiple 2 oor © Teor L 2 pair U 12tiple 3 Beare D 37 core M20 pair XL 4 Aone Fl pair N37 paie Y 3quat 1 Teor Spar Ro lupe ZL Tova A Weore ET pair S 3uiple 4th & Sth characters 00 0.75uun? exible (Class §) stranded tinned copper cores 01 LOmm? flexible (Clase $) stranded tinned copper cores 02 1.5mm? flexible (Class 5) stranded tinned copper cores 03 -2S.mm? stranded tinned copper entes: 04 Amm* stand ined copper cores” 05 4mm? single solid tinned copper core (special) 66 Gm stranded tinned copper cores stranded tinned copper cores NOTES: 1 Only cable core/size combinattons shown in Annex A, Table 7 shall be used. 2 Shaded entries signify non-preferred care sizes. 3 3» Hi cables above’ 1.9/3.3 KV rating have timed copper tape and semiconducting insulation screen. Guidelines for instrumentation, power and contro! cables for fixed and mobile ee é UKOOA er 2 3 4 <6 cr cn production facilities 22 Issue No2 Novembert996 Guidelines for instrumentation, power and control cables for Gxed and mobile JK OA Aumex © TS ile with reduced halogen sheathing, SPECIFICATION SHE Flame retardant instrumentation and control eabies 150/250V a1 LIKOGA. five performance code 5 Cablecade! G Colleatively Sereened Cable for IS Circwits ‘Cable code 1 Individually Sereened Cable for 18 Cirents Cable code 3 Collectively Sereened Cable for NonelS Cireuits Cable code IK Individually Screened Cable for Non-1S Circuits Five resistant instrumentation and control cables $50/250V geade with reduced hatogen sheathing, UKOOA fire performance code F C2 Cable code FL Collestively Sereencd Cube for 18 Ciretits c22 Cable code FM Individually Sereened Cable for 18 Cireaits C23 Cable cade EN Cotlestively Screened Cable for Non-IS Circuits C24 Cable code FP Individually Sereened Cable for Non-1S Civvuits Flame retardant power and control eables 600/1000V grade with reduced halogen sheathing, UKOOA fire performance code L cat Cable code LA. Single core Cable x c32 Cable ende LB Multicore Cable ‘ Fire resistant power and control cables 600/I000V grade with reduced halogen sheathing, UKOOA fire perfarmance code X can Cable code XC. Single core Cable ca * Cable code XD Multicore Cable Flaine retardant instrumentation and gonteot cables 1S0/2S0V grade with low smoke and fume sheathing, coral Cable code KG Collectively Sereened Cable for IS Cireuits C32 Coble code KH Individually Sereened Cable for IS Circuits cs3 Cable code K Collectively Seveened Cable for Non-IS Circuits C38 Cable endo KK, Individually Sereened Cable for Non-IS Cit yw smoke and fume sheathing, Fite resistant instrumentation and control cables 150°250V grade nce code G UKOOA fire perfor cet Coble code GL Colloctively Sereancd Cable for IS Circuits co2 Cable code GM Individually Sereened Cable for IS Circuits 63 Cable code GN Collestively Screened Cable for Nor=IS Circuits cea Cable code GP Individually Soreened Cable for Non-18 Circuits Flame retardant power nnd control cables 690/1000V grade with tow smoke and fume sheathing, UKOOA fire performance eode W / crt Cable code WA Single core Cable i C72 CCabie code WB Multicore Cable v Fire resistant power and control cables 600/2000V grade with low smoke and fume sheathing, ‘UKOOA fire performance code ¥ cal Cable code YC Single core Cable ca2 Cable code YD Multicore Cable Serial Data Cable Special) con Cable Code JYI0S Flere retardant $0 $2 cunxialenble for serial dats highway and ‘8themet links. Flame retardant power cables 8.7/15 kV grade with reduced halogen sheathing, WKOOA fire performance code H C104 Cable code HA Single core Cable C102 Cable vote DB ‘Three coro Cable Flame retardant power cables 3.8/6.6 KV grade with reduced halogen sheathing UKOOA fire performance code Mt cut Cable code MA Single core Cable cna Cable code MB “Three core Cable C12 Flame retardant power eables 1.9/3.3 kV geade with rethiced talogen shes UKOOA fire perfornaneo code N 11 Cable code NA Single core Cable can Cable code NB ‘yee core Cable eB t power cables 6.38/11 KV grade with reduced halogen sheathing, UKOOA fire performance code P C131 Cable code PA ‘Single core Cable C32 Cable code PE ‘Thee core Cable €.14 Flame retardant unarmoured cables 600/1000 V grade with reduced halogen sheat UKOOA fire performance code L : clad Cable code LE Single core Farthing Cable ca Cable code LF Single core Batery Cable C.1S Flame retardant unarmoured eabtes 600/1000 V gradte with low smoke and fume sheathing, UKOOA fire performance code W cust Cable code WE Single core Barthing Cable cis2 Cable code WF Single core Battery Cable proarn il UKOOA fase tation and control eables 1S0/250V grade with reduecd tatagen sheathing, UKQOA tite performanee eude J CULL Cable Code sci - Instrument cable pairs, collectively sereened for IS Circuits Design Conductor Conductor Si Insulation Binder Drain Wires Screen Bedding Armour Oversheath Applicable Standards Oversheath Colour Core Colour ‘Typically EPR/CSP/GS WB/CSP Malistranded tinned copper to Section 5.4.1 Refer to Annex A, Table 2 Exiruded EPR 250V grade Tape Tinned copper wires to Section 53.4 Metallized PETP Tape Extruded EPR or compound to BS 7655 Sect Galvanized steel wire beaid to Section 5.3.3 Extruded compound {0 BS 7635 Section 2.6 type SW2 with enhanced oil resistance, BS 6883:1991/IEC 332 part 3/BS 6459/BS 6360/RS 7655 Light Blue Pairs: Black, White 2.6 type SW2 C12 Cable Code JH instrument cable pairs, triples & quads, individually screened for IS circuits Design Conductor Conductor Size Insulation Tape Drain Wires Screen Bindor Bedding Armour Oversheath Applicable Standards Oversheath Colour Core Colours Typically EPRICSP/GSWR/CSP Mulk-sttanded tinnod copper to Section 5.4.1 Refer to Annes A Tables 3, 4 ane 5 xtmaded EPR 250V grade PETP Tinned copper wires to Section 5.3.4 Metallized PETP Tape Tape xtnided EDR or compound to BS 7655 Section 2.6 type SW2 Galvanized sicel wire braid to Section 5.3.3 Exttided compound (0 BS 7655 Scuten 26 type SW2 with enhanced oil resistance BS 6883;1991/IEC 332 part 3/BS 6469/BS 6360/BS 7655 Light Blue Pits: Black, White Triples: Black, White, Red Quads: Black, White, Red, Blac Guidelines fo production facilities Ise Nez November 1996 strumentation, power and control cables for fixed and mobile LK OOA 28 . a a oe oe ee or oe oi a oa ae an a CLS Cable Code ty - instrument cate pairs, callectively sereenedd Design Conductor Conductor size Insulation inder Drain Wires Screen Bedding, Amour Oversheath” Applicable Standards ‘Oversheath Colour Core Colour r mont circuits Typically EPR/CSP/GSWBICSP Mult-stranded tinned copper to Seetion 5.4.) Refer to Annex A, Table 2 Extruded EPR 250V grade Tape ‘Tinned copper wires to Section 5.3.4 Metallized PETP Tape Extruded EPR or compound to BS 7655 Section 2.6 type SW2 Galvanized steel wire braid to Section 5.3.3 Bxiraded compound to BS 7655 Section 2.6 type SW2 with ‘enhanced oil resistance 'BS 6883:1991/IEC 332 part 3/BS 6469/BS 6360/BS 7655 Grey Pairs: Black, White C14 Cable Code JK Instrument cable fairs, triples d quads, individually seveened for nomIS circuits Design Conductor Conduetor Si Insulation Tape Drain Wires Screen Binder Bedding Armour Oversheath “Applicable Standards Oversheath Colour Core Colours Typically EPR/CSP/GSWBICSP Multi-stranded tinned copper to Section 5.4.1 Refer to Annex A, Tables 3, 4and 5 Extruded EPR 250V grade PETP ‘Tinned copper wires to Section 5.3.4 Metallized PETP Tape Tape Extruded EPR or compound to BS 7655 Section 2.6 type SW2 Galvanized steel wire braid to Section 5.3.3, Bxiruded compound t@ BS 7655 Section 2.6 type SW2 with enhanced oif resistance BS 6883:1991/IEC 332 part 3/BS 6469/BS 6360/BS 7655 Grey Pairs: Black, White Triples: Black, White, Red > Quads: Black, White, Red, Blue Guidelines for instrumentation, power and control cables for fixed and mobile production fa ssu No.2 Novernberl996 25 /2SUV grate with reduced halogen sheathing, C2 —_Bire resistant instrumentation and eoutrot cables 15 UKOOA fire performance cade R C22 Cable Code PL ~ hastranene o le pairs, collectively screened for IS eiresits Design Typi Conductor ‘Multi-stranded tinned copper to Section 5.4.1 Conductor Size Roforto Annes A, Table Insulation MGT/Entruded EPR 250 grade Binder ‘Tope Drain Wires ‘Tinned copper wires to Section 53.4 Screen Metallized PETP Tape Bedding Extruded BPR Armour Galvanized stect wire braid to Seovion 5.3.3 Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with enbunced oll resistance Applicable Standards BS 6883:1991/IEC 332/IEC 331/BS 6469/85 6360/ BS 7655 Oversheath Colour Light Blue Core Colour Pairs: Black, White C22 Cable Code FM - Instrument cable pairs, triples & quads, individually screened for IS circuits Design “Typically MGTEPR/EPRIGSWBICSP Conductor Miutti-stranded tinned copper to Section 5.4.1 Conductor Size Refer o Armex A, Tables 3,4 and 5 Insulation MGT Extruded EPR 250V grade Tepe PETP Drain Wires ‘Tinned copper wires to Section 5.3.4 Screen Metaltized PETP Tape Binder Tape Bedding Extruded BPR Armour Galvanized steel wire braid to Section 5.3.2 Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with ‘enhanced oil resistance Applicable Standards BS 6883:1991/IEC 332/IEC 33 1/BS 6469/BS 6360/ BS 7655 Oversheath Colour Light Blue Core Cofours Pairs: Black, White Triples: Black, White, Red Quads: Black, White, Red, Blue conte = UKOOA November196 oo le oa EB FE Se ES G&S k= Ge ct eat mc Oe OU Ck C23 Cable Cade PN = Insiruner cable pairs, collectively serecned for nord D. Conductor Conductor Size Insulation Binder Drain Wi Sciven Bedding Amour Oversheath Applicable Standards Oversheath Colour Core Colour irewits ‘Typically MGT/EPRVEPW/GSWB/CSP ‘Mutti-stranded tinned copper to Seetion 5.4.1 Refer to Annex A. Table 2 MGT/Extruded EPR 250V grade Tape ‘Timed copper wires to Section 5.3.4 ‘Metallized PET? Tape Extruded EPR i Galvanized stecl wire braid 10 Section 5.3.2 Extruded compound to BS 7655 Section 2.6 type SW2 with snhanced oil resistance BS 6883:1991/IEC 332/1EC 331/BS 6469/BS 6360/ BS 7655, Grey Pairs: Black, White 24 Cable Code FP - Instrument cable pairs, triples & quad, individually screened fr nor-IS civenita Design Conductor Conductor Size Insulation Tape Drain Wires Screen Binder Applicable Standards Oversheath Colour Core Colours ‘Typically MOT/EPR/EPR/GSWE/CSP. Multi-stranded tinned copper to Section 5.4.1 Refer to Annex A, Tables 3, 4 and 5 MGT Extruded EPR 250V grade PETP. Tinned copper wires to Section 5.3.4 Metallized PETP ane Tape Extruded EPR Galvanized stecl wire braid to Section 3.3.5 Exinuced compound to BS 7655 Section 2.6 type SW2 with enhanced oil resistance [BS 6883: 1991/IEC 332/MEC 33 1/BS 6459/RS 6360/ RS 7653, Grey : Pairs: Black, White Triples: Biack, White, Red 7 Quads; Black, White, Red, Blue Guided production faci Issue No.2 November 996 for instrumentation, power and control cables for fixed and mobile UKOOA 27 C3 Plame retard UIKCOOA fire per . Design Conductor Conductor Size Insulation Bedding Armour Oversheath Applicable Standards ‘Oversheath Colour lant power and control cables 6O0/(0ODY yvade with reduced halogen sheat wrmanee code L. Cable Cade Li - Single vore cable for nowIS circuits ‘Typically EPR/CSPIPBWBICSP Muistranded tinned copper to Section 3.4.1 and 3.4.2 Refer to Arwex 4, Table Jed and purchase details Extruded EPR 1000V grade Extruded EPR or compound t0 BS 7655 Section 2.6 type SW2 Tinned phosphor bronze wire braid to Section 3.3.3 Extruded compound to BS 7653 Section 2.6 type SW2 with enhanoed ol resistance BS G889:1991MEC 332 part 3/BS 6460/28 6360/95 7655 Black C32 Cable Coxe LB - Multicore cable for non IS circuits Design Conductor Conduetor Size Insulation Binder Bedding Amour Oversheath Applicable Standards ‘Oversheath Colour Core Colour ‘Typically EPRICSPIGSWEYCSP ‘Muli-stranded tinned copper to Section 5.4.1 and 3.4.2 Refer to Annex A, Table Ta/b and purchase details xtmded EPR 1000V grade Tape Extruded EPR or compound to BS 7655 Section 2.6 typo SW2 Galvanized steel wite braid to Section 5.3.3 Extruded compound to BS 7655 Section 2.6 type SW2 with enhanced oil resistance BS 6883:1991/IBC 332 part 3/BS 6469/BS 6360/BS 7655 Black White, numbered or colours per Section 545 production facilities IksueNo2 Novermber1996 Guidelines for instrumentation, power and control eables for fixed and mobile LK OOA 28 cA ‘nm x& zx =x x | 06 —_ im maw km Z a _ o O lUcee let hl cA CAL Caz Fire resistant power and control eables 600/L000V grade with reduced halogen sheathing, UKOOA fire pertormanee coite X Cable Come XC - Single core cables for notelS circrats ‘Typically MGT/EPR/EPR/PRWB/CSP Design Conchictor Multi-stranded tinned coppor to Section $,4,1 and 54.2 Conductor Size Refer ta Annex A, Table ! and purchase details Insulation MGT/Extnuded EPR L000V grade Bedding Extruded EPR Armour Tinned phosphor bronze wire braid to Section 5.3.3 Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with ‘enhanced oil resistance Applicable Standards BS 6883:1991/IEC 332/1EC 331 /BS 6469/88 6360) BS 7655 ‘Oversheath Colour * ‘Black Cable Code XD - Multicore cables'for non-IS circuits Design Typically MGT/EPR/BPR/IGSWBICSP Conductor Multi-stranded tinned copper to Section 4.4.1 ancl 4.4.2 Conductor Size Refer to Annex A, Table } and purchase details Insulation MGT/Extraded EPR 1000V grade Binder Tape Bedding Extruded EPR Annour Galvanized steel wire braid to Section 5.3.3 ‘Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with enhanced oil resistance Applicable Standards BS 6883:1991/IEC 332/1EC 331/BS 6469/BS 6360/ BS 7655 Oversheath Colour Black Core Colour White, numbered or colours per Section 5.4.5 Guidelines for instrumentation, power and control cables for fixed and mobile production facilities We UKOOA Issue Nod November1996 CS Hlame retan sheathin C51 Cable Cove KG Instrument cable pars, collectively sorcened for 18 Design Conductor Conductor Size Insulation Binder Drain Wires Screen Bedding Armour Ovorsheath Applicable Standards ‘Oversheath Colour Core Colour 1 instrumentation and conteot eables 15072S0V grade with low swobe aud fume UIKOOA fire performance cade K Typically EPRILSP/IGSWBMLSF Multi-stranded tinned copper to Section 5.4.7 Refer to Annex A, Table 2 Extnided EPR 2S0V grade Tape “Tinned copper wires to Seciton 3.3.4 Metallized PETP Tape Extruded EPR or LSP to BS 7655 Section 2.6 type SW4 Galvanized steel wire braid to Section 5.33 Extruded LSF to BS 7655 Scetion 2.6 type SW4 with enhanced oil resistance BS 6883:199 IBC 332 part 3/BS 6469/88 6360/85 7655, Light Blue Pairs: Bleck, White C52 Cable Code KH - Instrument cable poirs, triples & quads, individually screened for 15 cireuits Design Conductor Conductor Size Insulation Tape Drain Wires Screen Binder Bedding Amour Overshe Applicable Standards Oversheath Colour Core Colours ‘Typically EPR/LSF/IGSWBVLSF Maltistranded tinned copper to Section 5.4.1 Refer to Annex A, Tables 3, 4 and S Extruded EPR 250V grade PETP ‘Tinned copper wires to Sectton 5.3.4 Metallized PETP Tape Tape Extruded EPR or LSF to BS 7655 Section 2.6 type SW4 Galvanized stee] wire braid to Section 5.3.3 Extruded LSF to BS 7655 Scotion 2.6 type SW4 with enhanced oil resistance, BS 6883:1991/IEC 332 part 3/BS 6469/85 6360/B5 7655 Light Blue Pairs: Black, White Triples: Black, White, Red Quads: Binek, White, Red, Blue Guidelines for production faci Issue Nod Novemberi996 strumentation, power and contro! eables for fixed and mobile LIK COA 30 a —_ C53 Cable Coste K- insirunent cable pairs, callectively sereened for notelS « Design Conductor Conductor Size Insulation Binder Drain Wires Screen Bedding Amour Oversheath Applicable Standards Oversheath Colour Core Colour Typically FPRLSTIGSWaIL.SF Molti-stranded tinned copper to Seetion 5.4.1 Refer to Amex A, Table 2 Extruded EPR 250V grade ‘Tape Tinned copper wires to Section 3.3.4 Metollized PETP Tape Extruded EPR o LSF to BS 7655 Section 2.6 type SW4 Galvanized steel wire braid to Section 5.3.3 Eximided LSF to BS 7655 Section 2.6 type SW4 with enhanced oil resistance ‘BS 6883:1991/IEC 332 part 3/BS 6469/BS 6360/BS 7655 Grey Pairs: Black, White C54 Cable Code KK- Instrument cable pairs, riples & quads, individually sereened for nowlS circuits Design Conductor Conductor Size Insulation Tape Drain Wires Screen Binder Bedding Armour Oversheath Applicable Standards Oversheath Colour Core Colours ‘Typically EPRVLSF/GSWBILSF Malti-stranded tinned copper to Seetion 5.4.1 Refer to Annex A, Tables 3, 4 and S Exinided EPR 250V grado PETP Tinned copper wires to Section 5.3.4 Metallized PETP Tepe ‘Tape Extruded EPR or LSF to BS 7655 Section 2.6 type SWA Galvanized steel wire braid to Section 5.3.3 Extruded LSF to BS 7655 Seotion 2.6 type SW4 with enhanced oil resistance ‘BS 6883:1991/MEC 332 part 3/BS 6469/BS 6360/BS 7655 Grey Pairs: Black, White Triples: Black, White, Red . Quads: Black, White, Red, Blue production facilities Issue No.2 Novemberi9%6 framentation, power and control cables for fed and mobile Ug OO) 31 C6 ive resistant instrumentation and control exbles 1SW/250V grade with low smoke und fare sheathing, UKOOA fire performance code G CG.1 Cable Code GL - Instrument cable pairs, collectively screened fir 18 circuits Design ‘Typically MGT/EPR/EPR/GSWB/LSF Conductor ‘Multkstranded timed copper to Section 54.1 Conductor Size Refer to Anvex A, Table 2 Insulation MGT/Entruded EPR 250V grade Binder Tape Drain Wires Fined copper wires to Section 5.3.4 Screen Metallized PETP Tape Bedding Extruded EPR Armour Galvanized stec! wire braid to Seetton 5.3.3 ‘Oversheath Exwuded LSF to BS 7655 Section 2.6 type SW4 with enanced oil resistance, Applicable Standards BS 6883:1991/IEC 332/1EC 331/BS 6469/35 6360/ BS 7695 Oversheath Colour Light Blue Core Colour Pairs: Black, White C62 Cable Code GY Instrument cable pairs, viples & quads, individually screened for IS circuits Design lly MGT/EPR/EPR/GSWBALSF ‘Conductor ‘Mult-stranded tinned copper to Section 34.7 ‘Conductor Size Refer to drmex A, Tables 3, 4 and S Insulation MGT Exinided EPR 250V grade Tape PETP, Drain Wires ‘Timed copper wires to Section 5.3.4 Sereen Metallized PETP Tape Binder Tape Bedding Extruded EPR Asmour Galvanized ste! wire braid to Section 5.2.3 Oversheath Extnided LSF to BS 7655 Section 2.6 type SW4 with enhanced oil resistance Applicable Standards [BS 6883:1991EC 332/IEC 331/BS 6469/85 6360 BS 7635 ‘Oversheath Colour Light Bine Core Colours Pairs: Black, White ‘Triples: Black, White, Red Quads: Black, White, Red, Blue Guidelines for instrumentation, power and control cables for fixed and mobile Seti fe i UKOOA lesue No2 November1996 Design Conductor Conductor Size Insulation Binder Drain Wires Sereen Bedding Amour Oversheatli Applicable Standards Oversheath Colour Core Colour 6.3 Cable Code GN - Instrument cable pairs, collectively screened for non-IS “rewits ‘Typically MOT/EPR-EPR/GSWBILSF Mult-siranded tinned copper to Section 3.4.1 Refer to Annex A, Table 2 MG'tVextruded EPR 250V grade Tape Tinned copper wires to Section 5.3.4 Motallized PETP Tape Extruded EPR Galvanized steel wire braid to Section 5.3.3 Exinided LSF to BS 7655 Section 2.6 type SW4 with enhanced oil resistance BS 6883:1991/1C 332/IEC 331/BS 6469/88 6360/ BS 7635 Grey Pairs: Black, White C64 Cable Code GP - Instrument cable pairs, wipies & quads, individually screened for norlS cireuits Design Conductor Conductor Size Insulation Tape Drain Wires ‘Screen Binder Bedding Armour Oversheath, Applicable Standards ‘Oversheath Colour Core Colours ‘Typically MGT/EPR/EPR/GSWBVLSF Mult-stranded tinned copper to Section $.4.1 Refer to Armes 4, Tables 3 4 and 5 MGT Extruded BPR 250V grade PETP Tinned copper wires 10 Section 5.3.4 Metallized PETP Tape ‘Tape Extruded BPR Galvanized stect wire braid to Section 5.3.3 Extruded LSF to BS 7655 Seotion 2.6 type SW4 with enhanced oil resistance [BS 6883:1991/IBC 332/IEC 33 1/BS 6469/BS 6360/ BS 7655 Grey Pairs: Black, White Triples: Biack, White, Red . Quads: Black, White, Red, Blue Guidelines for instrumentation, power and control cables for fixed and mobile LYK CCA production faciities Issue No2 Noverberi99% 33 C7 Blame retardant power aud contrul cates 6UO/000V grade with low smoke and fume sheathing, ULOOA fire performance code W Cable Gade WA - Single core cable for norelS circuits xX Design ‘Typically EPR/LSF/PBWBILSF : Conductor Multisttanded tinned copper to Section 5.4.2 and 5.4.2 Conductor Size Refer io Annex A, Table } and purchase details Insulation Extruded EPR 1000V grade Bedding, Extruded EPR or LSF to BS 7655 Scction 2.6 type SW4 Armour “Tinsied phosphor bronze wire braid to Section 5.3.3 Oversheath Extuded LSF to BS 7655 Section 2.6 type SW4 with enhanced oil resistance ‘Applicable Standards BS 6883:1991/IEC 332 part 3/BS 6460/BS 6260/BS 7655 Oversheath Colour Black C22 Cable Code WB- Multicore cable for norlS circuits Design ‘Typically EPR/LSE/GSWB/LSE Conductor Malt-stranded tinned copper to Section $ 4) and 5.4.2 Conductor Size > Refer to Annex A, Table 1 and parehase details Insulation Extruded EPR 1000V grade Binder Tape Bedding Extruded EPR or LSF to BS 7655 Section 2.6 type SW4 Armour Galvanized Stee! wire brad wo Section 5.3.3 Oversheath Extruded LSF to BS 7655 Section 2.6 type SWS with enhanced oil resistance Applicable Standards BS 6883:199/IEC 332 part 3/88 6469/88 6360/BS 7655 Oversheath Colour Black ; Core Colour ‘White, numbered or colours per Section 5.4.5 Guidelines for instrumentation, power and control cables for fixed and mobile ee 7 UKOOA tesucNo2 Novenber199 C.8 Fire resistant power and control cables 600/1000V UKOOA Are performance cote ¥ Design Conduetor Conductor Size Insulation Bedding Armour Oversheath Applicable Standards Oversheath Colour rade with low smoke and fame sheathing, CRE Cable Code YC Single core cable for noweiS circuits ‘Typically MGTEPREPR/PRWBILSF Malti stranded tinned coppor to Section $.4.1 and $4.2 Refer to Annex A, Table J and purchase details MGT/Extruded EPR 1000V grade Extruded EPR Titmed phosphor bronze wire braid to Section 5.2.3 Extruded LSP to BS 7655 Section 2.6 type SW4 with enhanced of resistance BS G883:1991/1EC 332/1EC 331/BS 6469/85 6360/ BS 7633 Black C&2 Cable Code YD Multicore cable for non-IS circuits Design Conductor Conductor Size Insulation Binder Bedding, Armour Oversheath Applicable Standards Oversheath Colour Core Colour “Typically MGT/EPR/EPRIGSWB/LSF “Mult-stranded tired copper to Section 5.4.1 and 5.4.2 Refer to Annex 4, Table 1 and purchase deta MGTT/Extruded EPR 1000V grade ‘Tape Extruded EPR Galvanized Steel wire braid to Section 5.3.3 Extruded LSF to BS 7655 Section 2.6 type SW4 with enhanced oil resistance BS 6883:1991/JEC 332/1BC 331/BS 6469/BS 6360/ BS 7655, Black White, numbered or colours per Section 3.4.5 Guidelines for instrumentation, power and control cables for fixed and mobile EK OCA production facilities Issue No.2 Novembert996 35 Serial Data Cable (Special) Cable Code JY105 - Flame retardant 5010 eexacial eee for serial dats highnsay und Ethernet Finks, Design Construction: Conductor 4mm? (1/2.25mm) solid tinned copper Insulation Cellular PTFE (nataral) 2mien nomial wall thickness Tape Metallized! PETP/aburviniam 0.05mm 1st Sereen Tinned copper braid 34 AWG - 95% minimum coverage Separator Tape Metallized PETP/aivminium 0.05mm 2nd Sereen Tinned copper braid 34 AWG - 95% minimum coverage Inner Facket PTFE Armour Galvanized steel wire braid to Section 5.3.3 Oversheath “Thermoplastic LSF with enhanced oil resistance Applicable Standards BS 6883:1991/1EC 332 Part 3/ BS 6469/08 6360/ BS 7655 (Gee Note 1) Oversheath Colour Orange ‘The following nominal electrical characteristics shall be provided by the cable ane confirmed by test results by Supplier Impedance 502 Cepacitance | * 82pF/m Velocity of propagation 80% Attenuation | 0.54B/30.48m (0.5dB/100R) @ 1OME2 Note 1: Supplier may provide equivalent ASTM test methods on cable make-up to inner jacket stage. instrumentation, power and control eables for fixed and mobile Z i UKOOA a zc zk z= Se SS wee oe ee eo oe ess cn clot C102 B UKOOA fire Flame retardant power enbles 8.7/5 kV grade with reduced halogen sheathi performance code H Cable Code HA + Single core cable Design ‘Typically EPR/CSP/PBWBICSP Conductor Annealed tinned copper to Section 5.4. and 5.42 Conductor Size Refer to Annex A, Table 6 and purchase details Conductor screen Scmiconducting material Inswiation Extruded BPR 15 kV grade Insulation soroen Scmiconducting material and tinned copper tape Bedding, Extruded EPR or compound to BS 7655 Section 2.6 type SW2 ‘Ammour Tinned phosphor bronze wire braid to Section 5.3.3 Oversheath Exirided compound to BS 7635 Section 2.6 type SW2 with ‘enhanced oif resistance Applicable Standards © BS 6883:1991/IEC 332 part 3/BS 6469/BS 6360/BS 7653 Oversheath Colour Red Cable Code HB - Multicore cable Design “Typically EPR/CSP/GSWBICSP Conductor Annealed tinned copper to Section 5.4.1 and $.4.2 Conductor Size Refer to Annex A, Table 6 and purchase details ‘Conductor screen Semniconducting materia Jnsulation Extruded EPR 15 kV grade Insalation screen ‘Semiconducting materia! and tinned copper tape Binder Tape Bedding Extruded EPR or compound to BS 7655 Section 2.6 type SW2 Armour Galvanized steel wire braid to Section 5.3.3 ‘Ovorsheath Extruded compound to BS 7655 Section 2.6 type SW2 with enhanced oil resistance Applicable Standards ‘BS 6883:1991/IEC 332 part 3/BS 6469/8S 6360/BS 7655 Oversheath Colour Red Core Colour White, numbered or colours per Section 3.4.5 ATT Novembert996 ng, UKOOA fire CULL Cable Code MA + Single core cable Design Typically EPR/CSP/PBWBYCSP Conductor Annealed tinned copper to Section 5.4.1 anid 5.4.2 Conductor Size Refer to Avwes A, Table 6 ond purchase details ‘Conductor sereen Sormiconducting material Extruded BPR 6.6 kV grade Semicondueting material and tinned copper tape Extruded EPR or compound to BS 7655 Section 2.6 type SW2 ‘Tinned phosphor bronze wire braid to Section 5.3.3 ‘Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with enhanced oil resistance Applicable Standards BS 6883:199 I/IEC 332 part 3/BS 6469/85 6300/85 1655 Overshesth Colour Red C12 Cable Code MB - Multicore cable Design “Typically EPR/CSP/GSWBYCSP Conductor * Annealed tinned copper to Section 5.4.1 and 5.4.2 Conductor Size Refer to Amex A, Table 6 and purchase details ‘Conductor sereen Semiconducting material Insulation Extruded EPR 6.6 KV grade Insulation screen Semiconducting material and tinned copper tape Binder Tape Bedding Extruded EPR or compound to BS 7655 Section 2.6 type SW2 Armour Gatvanized steel wire braid to Section 5.3.3 Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with enhanced oll resistance Applicable Standards BS 6883:1991/IEC 332 part 3/BS 6469/05 6360/BS 7655 Oversheath Colour Red Core Colour White, numbered or colours per Section 5.4.5 Guidelines for tustrumer n, power and control cables for fixed and mobi proce he 7 UKOOA pose ‘Novernber1 996 _ os OU hUreerlhlUlhlU OSS C12 lame retardant power eables 3.8/6.6 KV grade with reducodl halogen sheathing, UKOOA fire performance code N C121 Cable Cele NA Single core cable Design Conductor Conductor Size Insulation Binder Bedding Armour. Oversheath Applicable Standards Oversheath Cotour : C122 Cable Code NB- Multicore cable * Design Conductor Concuctar Size Insulation Binder Applicable Standards ‘Oversheath Colour Core Colour ‘Typically EPR/CSP/PBWB/CSP Annealed tinned copper to Section 5.4.7 and 5.42 Refer to Anmex A, Table 6 and purchase details Exinaded EPR 3.3 KV grade ‘Tape Extruded EPR or compound to BS 7655 Section 2.6 type SW2 “Tinned phosphor bronze wire braid to Section 5.3.3 Extruded compound to BS 7655 Section 2.6 type SW2 with ‘enhanced oil resistance BS 6883:1991/1EC 332 part 3/BS 6469/15 6360/BS 7655 Red ‘Typically EPR/CSP/GSWBICSP ‘Annealed tinned copper to Section 5.4.1 and 5.4.2 Refer to Annex A, Table 6 and purchase details Extruded EPR 3.3 kV grade Tape Exinuded EPR or compound to BS 7655 Section 2.6 type SW2 Galvanized steel wire braid to Section 5.3.3 Extruded compound t0 BS 7655 Section 2.6 type SW2 with enhanced oil resistance 'BS 6883:1991/IEC 332 part 3/88 6469/BS 6360/BS 7655 Red White, numbered or colours per Section 5.4.5 production facilities Issue No.2 Novembert936 Guidelines for instrumentation, power and control eables for fixed and mobile | IK COA 39 CAS Flame retardant power cables 6.39/11 KY grade with reduced Inlogen sheathing, UKOOA fire performance code P CIBT Cable Code PA + Single cove cable Design Conductor Conductor Size Conductor sereon Jnsutation Insulation screen Bedding, Armour Overshesth Applicable Standards ‘Oversheath Colour C132 Cable Code PB- Miulicore cable Design ‘Conductor “ Conductor Size Conductor sereet Insulation Insulation screen Binder Bedding Amour ‘Overshesth Applicable Standards Oversheath Colour Core Colour ‘Typically EPR/CSPPBWBICSP Annealed tinned copper to Section 5.4] and 34.2 Refer to Annex A, Table 6 and purchase details Somivonducting material Extruded EPR 11 kV grade Semiconducting material and tinned copper tape Extruded EPR or compound to BS 7655 Section 2.6 type SW2 ‘Tinned phosphor bronze wire braid to Section 5.3.3 Extruded compound to BS 7655 Section 2.6 type SW2 enhanced oil resistance BS 6883;1991/MEC 332 part 3/BS 6469/BS 6360/85 7655, Red ‘Typically EPR/CSP/GSWBICSP Annealed tinned copper to Section 5.4.1 and 5.4.2 Refer to Annex A, Table 6 and purchase details Semiconducting material Extruded EPR 11 kV grade Semiconducting matetial and tinned copper tape ‘Tape Extruded EPR or compound to BS 7655 Section 2.6 type SW2 Galvanized steel wire braid to Section 5.3.3 Extruded compound to BS 7655 Section 2.6 type SW2 with ‘enhanced oil resistance BS 6883:1991/IEC 332 part 3/BS 6460/BS 6360/BS 7655 Red White, nurmbered or colours per Section 5.4.5 production facil Issue No2 Novembert996 Guidelines for instrumentation, power and control cables for fixed and mobile TIKOOA 40 = ot lhlUrelUlUrelUreer hCUrk nr x - St hUelhCUmelCOREX { onarmoured cables GUO/LNODY grade with reduced halogen sheathing, UKOOA ce ele T, Flame retard € perf CHAI Cable Code LE- Single core earthing cade Design Typically EPRICSP Conductor Multi-stranded tinted copper to Section $.4.1 and 5.4.2 Conductor Size Refer to Annex A, Table fa.and purchase details Insulation Extruded EPR 1000V grade Oversheath Exinuded compound to BS 7655 Section 2.6 type SW2 with enhanced off resistance Applicable Standards BS 6883:1991/IEC 332 part VBS 6469/BS 6360/BS 7655 ‘Oversheath Colour Green/yellow C142 Cable Code LF - Single core battery cable Design Typically EPR/CSP : Conductor’ : Multisttanded tinned copper to Section 5.4.1 and 5.4.2 Conductor Size Refer to Annex A, Table Jat wd purchase details Insulation Extruded EPR 1000V grade Oversheath Extruded compound to BS 7655 Section 2.6 type SW2 with enhanced oil resistance Applicable Standards BS 6883:1991/IEC 352 part 3/BS 6469/BS 6360/BS 7655 ‘Oversheath Colour Black CAS Flame retardant unarmoured cables 600/1000V grade with low smoke and fume sheathing, UKOOA fire performance code W “15.1 Cable Code WE - Single core earthing cable Design Typically EPR/LSF Conductor! Multi-stranded tismed copper to Section 5.4.1 and 5.4.2 Conductor Size Refer to Annex A, Table 1a and purchase details Insulation Extruded EPR 1000V grade Oversheath Extruded compound to BS 7635 Section 2.6 type SW4 with enhanced oil resistance Applicable Standards BS 6883:199//1EC 332 part 3/BS 6469/DS 6360/08 7655. Oversheath Colour Greenyellow C152 Cable Code IVF Single core battery cable Design ‘Typically EPR/LSF Multi-strunded tinned copper to Section $4.1 and 5.4.2 Conductar Conductor Size Refer to Annex A, Table Ia and purchase details Insulation ‘Exmuded EPR 1000V grade : ‘Oversiteath Extruded compound to BS 7655 Section 2.6 type SW4 with enhanced oit resistance Applicable Standards BS 6883:1991/IEC 332 part 3/BS 6469/BS 6360/BS 7655 Oversheath Colour Black Guidelines for instrumentation, power and control cables for fixed and mobile UKOOA roduetion facilities n Issue No2 Noverburi906 Annex D CABLE PARAMETERS REQUIRED POR SUPPLIER DATA SHEETS “the foltowing minimum information should be provided for each cable type supplied. It may be-convenient to tabulate these parameters for multiple codes of a similar type, together with a generic erase-soctional drawing detailing the construction, NOTE: The data shown in the table below is for illustrative purposes ony and does not form part of these Ee. = Guidelines. Cable code, — B JGHOO JCKOO JS100 S & 2 _— SS ‘Weight ‘kg/km 395 1030" 1500 ‘Currentraling Continuous @ 40°C A 6 € i] aT = ee (Conductor temp = 250°C) De veatanve mas @20T an TET 367 167 —— sa 3s | Voli dropiampercimetre mV/Am 56 36 36 Teactanee oi Clem a wa wa Tapedancs Wonk km wa wa we Core sarcen Teaiseance OPE Sim we wa wa Noverer1996 4 a_PPehwaeEehUhlULrerllUL UL Url hl hl le ltl!

You might also like