Operating
Gas point Normal
handled Air / Water
Gas constant J/kgK 295,4
Mol. weight kg/kmol 28,15
Delivered volume flow
(1.013 bar & 0°C dry) Nm 3 /h 193.000
Weight flow (wet) kg/h 261.762
Cooling water inlet temp. °C 38,0
Approach temp. °C 5,0
Re-cooling temp. °C 43,0
Discharge Conditions at
battery limits:
Pressure bar a 6,20
Temperature °C 87,9
Performance:
Guaranteed Power at
coupling with 1,5% tolerance kW 16169
acc VDI 2045
Power Guarantee - Yes
Flow Guarantee Yes
Driver rating kW see driver datasheet
Bull gear speed rpm 1.500