You are on page 1of 5

V.A.S.

DESIGN & INFRA STRUCTURE


CONSULTANTS PVT. LTD.
Report No-VAS/NDTCT/IMP066
BIL ASSAM CORE CUTTING REPORT
TOWER TYPE: GBT
CIRCLE: ASSAM

SITE DETAILS
Site ID : IMP066
TECH. ID: NEGT10117 OVER ALL SITE PHOTOGRAPH
Type of Site: GBT
Cluster: Imphal
SAM & SAM Name & contact no: N/A
Tower Core Cutting Agency : VAS
Tower height (M) N/A
NO of core 2
Tower configuration: --
Wind Speed: 170 Kmph
Type of Foundation PILE
Engineer Name Mr.Lalchand

Observation regarding footing & column

Sample ID-
IMP066 Correction Equivalent Cube
Height
Sample Dia (mm) Factor of Compressive Average
(mm)
Name leg height/Dia Strength(N/mm2)
N0-1
L1-C1 68.75 121.14 0.97 21.56
19.25
L2-C1 69.02 87.50 0.92 16.94

Average Compressive strength of Column= 19.25 N/mm2 >17

Hence strengthening of Foundation is not required


Site ID: IMP066

Site Name: NEGT10117

c/c=6200 c/c=
Triangular Rectangular
1. Type Of foundation

A. Isolated footing
B. Raft Foundation Rectangular Triangular
C.Pile Foundation

2. Column Size

Size at bottom …….800…….. x …….800…….. mm


Size at Top …….800…….. x …….800…….. mm
Column Height …….2600…….. mm
Height of Column Exposed Ground Level …….750…….. mm
Center to center distance …….6200…….. mm

3. Column Condition

Crack found on column…………… YES NO PHOTO


Column surface Rought…………… YES NO PHOTO
Column Found TIlted………………. YES NO PHOTO
(how much tilt…………………………… ………………0.0……………..)
Honycombing Found Column……… YES NO PHOTO
Column is found ecentric with raft……… YES NO PHOTO
Measure face of column to edge of raft (…………………0.0…………….)
Base plate is found center of column….. YES NO PHOTO
(If ecentric measure center of column to center of base plate)
Crack or honycombing found at the bolt grouting portion YES NO PHOTO
Foundation lock nut & bolt missing YES NO PHOTO
Rebar visible in column YES NO PHOTO
Rusting in column rebar YES NO PHOTO
Proper cement quantity found in column YES NO PHOTO

4. Raft Size

Width of raft/footing/Pile Cap…………………………………2600 to 2600 mm


Depth of raft / footing/Pile cap…………………… 300 to xxx mm
Size of raft step length……………………………… xxx Width xxx Depth xxx
PCC work found…………………………………………………………….. YES NO PHOTO
Sand Filling …………………………………………………………………… YES NO PHOTO
Crack found in raft ………………………………………………………… YES NO PHOTO
Rebar visible in raft ………………………………………………………… YES NO PHOTO
Rusting in raft re-bar ……………………………………………………… YES NO PHOTO
Higher aggregate quantity found concrete ……………………… YES NO PHOTO
Right cement quantity found in concrete ……………………….. YES NO PHOTO
Surface of raft is found rough ………………..……………………….. YES NO PHOTO
Back filling Required …………...………………..……………………….. YES NO PHOTO
5. Soil Condition

Soil strata found at site ………………..…………………… Hard Medium Soft


Type of soil …………………………………..…………………… Sandy Sandy clay Silty Clay
Water contant in soil……………………..………………….. High Average Low

6. Reinforcement Condition

Rebar in columns…….Not Visible……No's………….Not Visible…………Dia (mm)


Rebar Cover in columns…….Not Visible……………………………..…………Dia (mm)
Rebar in raft…………….Not Visible……No's………….Not Visible…………Dia (mm)
Rebar Cover in raft……...…….Not Visible……………………………..…………Dia (mm)
Grade of re-bar……...…….Not Visible……………………………..…………………………..

DRAW FOUNDATION ELEVATION


800 750

G.L G.L
1850

900 800 900

xxx xxx
300
xxx

C/C = 6200 mm
CORE TEST RESULTS (SITE ID-IMP066)
TEST UNIT OF
S. NO. PARAMETER RESULTS
METHOD RESULTS
IS:516 pt-
1.PHYSICAL TEST L1-C1
4:2018
IS:516 pt-
1) Idenfication Mark
4:2018
IS:516 pt-
2) Date of Casting
4:2018
IS:516 pt-
3) Date of Testing 13-05-2020
4:2018
IS:516 pt-
4) Age of Specimen Days
4:2018
IS:516 pt-
5) Average Dimension of specimen
4:2018
IS:516 pt-
a Height 121.14 mm
4:2018
IS:516 pt-
b Diameter 68.8 mm
4:2018
IS:516 pt-
6) Height/Diameter Ration 1.76
4:2018
IS:516 pt-
7) Height/Diameter Ration correction factor 0.97
4:2018
IS:516 pt-
8) Correction factor for core diameter (Core having diameter less then 100mm) 1.06
4:2018
IS:516 pt-
9) Cross-Section area 3710 mm^2
4:2018
IS:516 pt-
10) Maximum load 62 KN
4:2018
IS:516 pt-
11) Measured Compressive Strength 16.71 N/mm^2
4:2018
IS:516 pt-
12) Corrected Compressive strength 17.71 N/mm^2
4:2018
IS:516 pt-
13) Corrected Cylinder Strength 17.25 N/mm^2
4:2018
IS:516 pt-
14) Equivalent Cube Strength 21.56 N/mm^2
4:2018
CORE TEST RESULTS (SITE ID-BHGGT01)
TEST UNIT OF
S. NO. PARAMETER RESULTS
METHOD RESULTS
IS:516
1.PHYSICAL TEST L2-C1
pt-4:2018
IS:516
1) Idenfication Mark
pt-4:2018

IS:516
2) Date of Casting
pt-4:2018

IS:516
3) Date of Testing 13-05-2020
pt-4:2018

IS:516
4) Age of Specimen Days
pt-4:2018

IS:516
5) Average Dimension of specimen
pt-4:2018

IS:516
a Height 87.50 mm
pt-4:2018

IS:516
b Diameter 69.02 mm
pt-4:2018
IS:516
6) Height/Diameter Ration 1.27
pt-4:2018
IS:516
7) Height/Diameter Ration correction factor 0.92
pt-4:2018
IS:516
8) Correction factor for core diameter (Core having diameter less then 100mm) 1.06
pt-4:2018
IS:516
9) Cross-Section area 3739 mm^2
pt-4:2018
IS:516
10) Maximum load 52 KN
pt-4:2018
IS:516
11) Measured Compressive Strength 13.91 N/mm^2
pt-4:2018
IS:516
12) Corrected Compressive strength 14.74 N/mm^2
pt-4:2018
IS:516
13) Corrected Cylinder Strength 13.55 N/mm^2
pt-4:2018

IS:516
14) Equivalent Cube Strength 16.94 N/mm^2
pt-4:2018