Professional Documents
Culture Documents
SITE DETAILS
Site ID : IMP066
TECH. ID: NEGT10117 OVER ALL SITE PHOTOGRAPH
Type of Site: GBT
Cluster: Imphal
SAM & SAM Name & contact no: N/A
Tower Core Cutting Agency : VAS
Tower height (M) N/A
NO of core 2
Tower configuration: --
Wind Speed: 170 Kmph
Type of Foundation PILE
Engineer Name Mr.Lalchand
Sample ID-
IMP066 Correction Equivalent Cube
Height
Sample Dia (mm) Factor of Compressive Average
(mm)
Name leg height/Dia Strength(N/mm2)
N0-1
L1-C1 68.75 121.14 0.97 21.56
19.25
L2-C1 69.02 87.50 0.92 16.94
c/c=6200 c/c=
Triangular Rectangular
1. Type Of foundation
A. Isolated footing
B. Raft Foundation Rectangular Triangular
C.Pile Foundation
2. Column Size
3. Column Condition
4. Raft Size
6. Reinforcement Condition
G.L G.L
1850
xxx xxx
300
xxx
C/C = 6200 mm
CORE TEST RESULTS (SITE ID-IMP066)
TEST UNIT OF
S. NO. PARAMETER RESULTS
METHOD RESULTS
IS:516 pt-
1.PHYSICAL TEST L1-C1
4:2018
IS:516 pt-
1) Idenfication Mark
4:2018
IS:516 pt-
2) Date of Casting
4:2018
IS:516 pt-
3) Date of Testing 13-05-2020
4:2018
IS:516 pt-
4) Age of Specimen Days
4:2018
IS:516 pt-
5) Average Dimension of specimen
4:2018
IS:516 pt-
a Height 121.14 mm
4:2018
IS:516 pt-
b Diameter 68.8 mm
4:2018
IS:516 pt-
6) Height/Diameter Ration 1.76
4:2018
IS:516 pt-
7) Height/Diameter Ration correction factor 0.97
4:2018
IS:516 pt-
8) Correction factor for core diameter (Core having diameter less then 100mm) 1.06
4:2018
IS:516 pt-
9) Cross-Section area 3710 mm^2
4:2018
IS:516 pt-
10) Maximum load 62 KN
4:2018
IS:516 pt-
11) Measured Compressive Strength 16.71 N/mm^2
4:2018
IS:516 pt-
12) Corrected Compressive strength 17.71 N/mm^2
4:2018
IS:516 pt-
13) Corrected Cylinder Strength 17.25 N/mm^2
4:2018
IS:516 pt-
14) Equivalent Cube Strength 21.56 N/mm^2
4:2018
CORE TEST RESULTS (SITE ID-BHGGT01)
TEST UNIT OF
S. NO. PARAMETER RESULTS
METHOD RESULTS
IS:516
1.PHYSICAL TEST L2-C1
pt-4:2018
IS:516
1) Idenfication Mark
pt-4:2018
IS:516
2) Date of Casting
pt-4:2018
IS:516
3) Date of Testing 13-05-2020
pt-4:2018
IS:516
4) Age of Specimen Days
pt-4:2018
IS:516
5) Average Dimension of specimen
pt-4:2018
IS:516
a Height 87.50 mm
pt-4:2018
IS:516
b Diameter 69.02 mm
pt-4:2018
IS:516
6) Height/Diameter Ration 1.27
pt-4:2018
IS:516
7) Height/Diameter Ration correction factor 0.92
pt-4:2018
IS:516
8) Correction factor for core diameter (Core having diameter less then 100mm) 1.06
pt-4:2018
IS:516
9) Cross-Section area 3739 mm^2
pt-4:2018
IS:516
10) Maximum load 52 KN
pt-4:2018
IS:516
11) Measured Compressive Strength 13.91 N/mm^2
pt-4:2018
IS:516
12) Corrected Compressive strength 14.74 N/mm^2
pt-4:2018
IS:516
13) Corrected Cylinder Strength 13.55 N/mm^2
pt-4:2018
IS:516
14) Equivalent Cube Strength 16.94 N/mm^2
pt-4:2018